8Installation BAT-F
Release
06
02/2014
Housing
Only technicians authorized by the manufacturer are permitted to open
the housing.
Install the device in the vertical position, with the antenna connections
pointing upwards..
At ambient temperatures > 140 °F (60 °C):
The surfaces of the device housing may become hot. Avoid touching
the device while it is operating.
Installation site requirements
If all the following requirements are fulfilled, you have the option of
installing the device in the indoor operator access area (characteristic
value A for mounting).
See “Device name and product code” on page 17.
You supply 24 V DC to 48 V DC SELV voltage to the device.
You install the device inside a building.
The surrounding air temperature is ≤140 °F (60 °C).
Applies exclusively for Finland, Norway, and Sweden:
You supply Power over Ethernet (PoE) to the device, with the PoE
data cable laid inside a building exclusively.
In any case, install this device in a switch cabinet or in an operating
site with restricted access, to which maintenance staff have exclusive
access if 1of the following requirements is fulfilled:
You supply 60 V DC to 250 V DC or 110 V AC to 230 V AC to the
device.
You install the device outside a building.
The surrounding air temperature is > 140 °F (60 °C).
Applies exclusively for Finland, Norway, and Sweden:
You supply Power over Ethernet (PoE) to the device, with the PoE
data cable laid outside a building or between buildings.
Applies to device variants with the characteristic value B and D for
mounting (indoor service access area, and outdoors):
See “Device name and product code” on page 17.
Install this device solely in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Lightning protection
See the information in the “WLAN Outdoor Guide”, chapter “Lightening
and Surge Voltage Protection”.
Install over voltage protector devices on every outdoor Ethernet cable.