Hitachi H8S/2212 Series User manual

I
IMPORTANT INFORMATION
READ FIRST
• READ this user's manual before using this user system interface cable.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface cable until you fully understand its
mechanism.
User System Interface Cable:
Throughout this document, the term "user system interface cable" shall be defined as the
following product produced only by Hitachi, Ltd. excluding all subsidiary products.
• User system interface cable (HS2212ECH61H)
The user system or a host computer is not included in this definition.
Purpose of the User System Interface Cable:
This user system interface cable is for connecting the emulator station and user system. This
user system interface cable must only be used for the above purpose.
Improvement Policy:
Hitachi, Ltd. (including its subsidiaries, hereafter collectively referred to as Hitachi) pursues a
policy of continuing improvement in design, performance, functions, and safety of the user system
interface cable. Hitachi reserves the right to change, wholly or partially, the specifications, design,
user's manual, and other documentation at any time without notice.
Target User of the User System Interface Cable:
This user system interface cable should only be used by those who have carefully read and
thoroughly understood the information and restrictions contained in the user's manual. Do not
attempt to use the user system interface cable until you fully understand its mechanism.
It is highly recommended that first-time users be instructed by users that are well versed in the
operation of the user system interface cable.

II
LIMITED WARRANTY
Hitachi warrants its user system interface cables to be manufactured
in accordance with published specifications and free from defects in
material and/or workmanship. Hitachi will repair or replace any
user system interface cables determined to be defective in material
and/or workmanship. User system interface cables are wearing parts
which Hitachi will not repair or replace if damaged and/or worn
through use. The foregoing shall constitute the sole remedy for any
breach of Hitachi's warranty. This warranty extends only to you, the
original Purchaser. It is not transferable to anyone who subsequently
purchases the user system interface cable from you. Hitachi is not liable
for any claim made by a third party or made by you for a third party.
DISCLAIMER
HITACHI MAKES NO WARRANTIES, EITHER EXPRESS OR
IMPLIED, ORAL OR WRITTEN, EXCEPT AS PROVIDED
HEREIN, INCLUDING WITHOUT LIMITATION THEREOF,
WARRANTIES AS TO MARKETABILITY, MERCHANTABILITY,
FITNESS FOR ANY PARTICULAR PURPOSE OR USE, OR
AGAINST INFRINGEMENT OF ANY PATENT. IN NO EVENT
SHALL HITACHI BE LIABLE FOR ANY DIRECT, INCIDENTAL
OR CONSEQUENTIAL DAMAGES OF ANY NATURE, OR
LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE
USER SYSTEM INTERFACE CABLE, THE USE OF ANY USER
SYSTEM INTERFACE CABLE, OR ITS DOCUMENTATION,
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
EXCEPT AS EXPRESSLY STATED OTHERWISE IN THIS
WARRANTY, THIS USER SYSTEM INTERFACE CABLE IS SOLD
"AS IS ", AND YOU MUST ASSUME ALL RISK FOR THE USE
AND RESULTS OBTAINED FROM THE USER SYSTEM
INTERFACE CABLE.

III
State Law:
Some states do not allow the exclusion or limitation of implied warranties or liability for
incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which may vary from
state to state.
The Warranty is Void in the Following Cases:
Hitachi shall have no liability or legal responsibility for any problems caused by misuse, abuse,
misapplication, neglect, improper handling, installation, repair or modifications of the user system
interface cable without Hitachi's prior written consent or any problems caused by the user system.
All Rights Reserved:
This user's manual and user system interface cable are copyrighted and all rights are reserved
by Hitachi. No part of this user's manual, all or part, may be reproduced or duplicated in any form,
in hard-copy or machine-readable form, by any means available without Hitachi's prior written
consent.
Other Important Things to Keep in Mind:
1. Circuitry and other examples described herein are meant merely to indicate the characteristics
and performance of Hitachi's semiconductor products. Hitachi assumes no responsibility for
any intellectual property claims or other problems that may result from applications based on
the examples described herein.
2. No license is granted by implication or otherwise under any patents or other rights of any third
party or Hitachi.
Figures:
Some figures in this user's manual may show items different from your actual system.
Limited Anticipation of Danger:
Hitachi cannot anticipate every possible circumstance that might involve a potential hazard.
The warnings in this user's manual and on the user system interface cable are therefore not all
inclusive. Therefore, you must use the user system interface cable safely at your own risk.

SAFETY PAGE
READ FIRST
• READ this user's manual before using this user system interface cable.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface cable until you fully understand its
mechanism.
DEFINITION OF SIGNAL WORDS
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
DANGER
DANGER indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING
WARNING indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
CAUTION
CAUTION used without the safety alert symbol indicates a
potentially hazardous situation which, if not avoided, may result
in property damage.
NOTE emphasizes essential information.
IV

WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Do not repair or remodel the emulator product by
yourself for electric shock prevention and quality
assurance.
2. Always switch OFF the E6000 emulator and user system
before connecting or disconnecting any CABLES or
PARTS.
3. Always before connecting any CABLES, make sure that
pin 1 on both sides are correctly aligned.
V

H8S/2212 Series
FP-64E
User System Interface Cable
(HS2212ECH61H)
for E6000 Emulator
User’s Manual
ADE-xxx-xxx
Rev. 1.0
2/4/03
Hitachi, Ltd. HS2212ECH61HE

Cautions
1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent,
copyright, trademark, or other intellectual property rights for information contained in this
document. Hitachi bears no responsibility for problems that may arise with third party’s rights,
including intellectual property rights, in connection with use of the information contained in this
document.
2. Products and product specifications may be subject to change without notice. Confirm that you
have received the latest product standards or specifications before final design, purchase or use.
3. Hitachi makes every attempt to ensure that its products are of high quality and reliability.
However, contact Hitachi’s sales office before using the product in an application that demands
especially high quality and reliability or where its failure or malfunction may directly threaten
human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power,
combustion control, transportation, traffic, safety equipment or medical equipment for life
support.
4. Design your application so that the product is used within the ranges guaranteed by Hitachi
particularly for maximum rating, operating supply voltage range, heat radiation characteristics,
installation conditions and other characteristics. Hitachi bears no responsibility for failure or
damage when used beyond the guaranteed ranges. Even within the guaranteed ranges, consider
normally foreseeable failure rates or failure modes in semiconductor devices and employ
systemic measures such as fail-safes, so that the equipment incorporating Hitachi product does
not cause bodily injury, fire or other consequential damage due to operation of the Hitachi
product.
5. This product is not designed to be radiation resistant.
6. No one is permitted to reproduce or duplicate, in any form, the whole or part of this document
without written approval from Hitachi.
7. Contact Hitachi’s sales office for any questions regarding this document or Hitachi
semiconductor products.

i
Preface
Thank you for purchasing this user system interface cable (HS2212ECH61H) for the Hitachi’s
original microcomputer H8S/2212 Series.
The HS2212ECH61H is a user system interface cable that connects an H8S/2214 series E6000
emulator (HS2214EPI62H; hereinafter referred to as the emulator) to the IC socket for a FP-64E
package for the H8S/2212 series MCU on the user system.
The user system interface cable should be used with H8S/2214 series E6000 emulator
(HS2214EPI62H: hereinafter referred to as the emulator).

ii
Contents
Section 1 Configuration....................................................................................1
Section 2 Connection Procedures......................................................................3
2.1 Connecting User System Interface Cable to Emulator Station .........................................3
2.2 Connecting User System Interface Cable to User System................................................5
2.2.1 Installing IC Socket .............................................................................................5
2.2.2 Soldering IC Socket.............................................................................................5
2.2.3 Inserting Cable Head ...........................................................................................6
2.2.4 Fastening Cable Head..........................................................................................6
2.2.5 Fastening Cable Body..........................................................................................8
2.3 Recommended Dimensions for User System Mount Pad.................................................9
2.4 Dimensions for User System Interface Cable Head..........................................................10
2.5 Resulting Dimensions after Connecting User System Interface Cable.............................11
Section 3 Installing the MCU to the User System.............................................12
Section 4 User Interface Circuit ........................................................................14
Section 5 Verifying Operation...........................................................................15
Section 6 Notice ................................................................................................16

Section 1 Configuration
CAUTION
Use an IC149-064-175-B51 socket (manufactured by
YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64E package
IC socket on the user system.
Figure 1 shows the configuration of the HS2212ECH61H user system interface cable for the
FP-64E package.
To emulator station
Cable body
EIO board
Screws (M3 x 6 mm)
for fixing the cable body
User system
IC socket
Cable head
Screws (M2 x 12 mm)
with flat washers
Screws (M2 x 6 mm)
with flat washers
Socket cover
(for fastening cable head)
Figure 1 HS2212ECH61H User System Interface Cable
1

2
Table 1 lists the HS2212ECH61H components. Please make sure you have all of these components
when unpacking.
Table 1 HS2212ECH61H Components
No. Component Quantity Remarks
1 Cable body 1 Includes coaxial cable
2 Cable head 1 Consisting of two printed circuit boards
3 IC socket 1 For the FP-64E package
4 Socket cover 1 For installing a FP-64E packaged MCU
5 Screws (M2 x 12 mm) 4 For fastening cable head (with four flat washers)
6 Screws (M2 x 6 mm) 4 For installing a FP-64E packaged MCU (with four flat
washers)
7 CTS screws (M3 x 6 mm) 2 For fixing the cable body
8 Documentation 1 User’s manual for HS2212ECH61H (this manual)

Section 2 Connection Procedures
2.1 Connecting User System Interface Cable to Emulator Station
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are
correctly aligned.
2. The user system interface cable dedicated to the
emulator must be used.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
CAUTION
When connecting or removing the user system interface
cable, apply force only in the direction suitable for
connection or removal, while making sure not to bend or
twist the cable or connectors. Otherwise, the connectors will
be damaged.
2. After making sure the direction of the cable body connector is correct, firmly insert the cable
body connector into the emulator station socket (figure 2).
3. If the emulator has holes for fastening screws, fasten the cable body to the emulator station by
using the attached screws for fixing the cable body.
3

Emulator station
Cable body connector
Screws for fixing
the cable body
User system interface cable
E6000
Figure 2 Connecting User System Interface Cable to Emulator Station
4

2.2 Connecting User System Interface Cable to User System
WARNING
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are correctly
aligned. Failure to do so will result in a FIRE HAZARD and
will damage the user system and the emulator product or
will result in PERSONAL INJURY. The USER PROGRAM will
be LOST.
To connect the cable head to the user system, follow the instructions below.
2.2.1 Installing IC Socket
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of
the IC socket for a FP-64E package, and fasten it to the user system before soldering.
2.2.2 Soldering IC Socket
After fastening, solder the IC socket for a FP-64E package to the user system. Be sure to completely
solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly
more solder than the MCU.)
5

6
2.2.3 Inserting Cable Head
CAUTION
Check the location of pin 1 before inserting.
Align pin 1 on the IC socket for a FP-64E package on the user system with pin 1 on the user system
interface cable head, and insert the user system interface cable head into the IC socket on the user
system, as shown in figure 3.
2.2.4 Fastening Cable Head
CAUTION
1. Use a screwdriver whose head matches the screw head.
2. The tightening torque must be 0.13 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
3. If the emulator does not operate correctly, cracks might
have occurred in the solder. Check conduction with
a tester and re-solder the IC socket if necessary.
Fasten the user system interface cable head to the IC socket for a FP-64E package on the user system
with the four screws (M2 x12 mm; with four flat washers) provided. Each screw should be
tightened a little at a time, alternating between screws on opposing corners. Take special care, such
as manually securing the IC socket soldered area, to prevent the soldered IC socket from being
damaged by overtightening the screws or twisting the components.

Pin 1
Cable head
IC socket
(IC149-064-175-B51
manufactured by
YAMAICHI ELECTRONICS Co., Ltd.)
Screws (M2 x 12 mm)
with flat washers
User system
Figure 3 Connecting User System Interface Cable to User System
7

2.2.5 Fastening Cable Body
Connect the cable body to the cable head.
8
Cable body
Cable head
Remove jig
Push the remove jig
User system
Removing
Figure 4 Fastening Cable Body

2.3 Recommended Dimensions for User System Mount Pad
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with
an IC socket for a FP-64E package (IC149-064-175-B51: manufactured by YAMAICHI
ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those
of the actual chip's mount pad.
9
Unit: mm
0.50 ×15 = 7.50 ± 0.05
0.50 ± 0.05
0.50 ×15 = 7.50 ± 0.05
10.10 max
13.50 min
0.30 ± 0.05
13.50 min
10.10 max
Figure 5 Recommended Dimensions for Mount Pad

2.4 Dimensions for User System Interface Cable Head
The dimensions for the user system interface cable head are shown in figure 6.
Unit: mm
Tolerance: ±0.5 mm
63.5
63.5
19.3
19.3
25.0
25.0
Figure 6 Dimensions for User System Interface Cable Head
10

2.5 Resulting Dimensions after Connecting User System Interface Cable
The resulting dimensions, after connecting the user system interface cable head to the user system,
are shown in figure 7.
11
Cable head
User system
Unit: mm
Tolerance: ±0.5 mm
14.0 35.1
IC socket
(IC149-064-175-B51
manufactured by
YAMAICHI ELECTRONICS Co., Ltd.)
Figure 7 Resulting Dimensions after Connecting User System Interface Cable
This manual suits for next models
1
Table of contents
Other Hitachi Cables And Connectors manuals
Popular Cables And Connectors manuals by other brands

Foxun
Foxun SX-SP142E-HD4K2K operating instructions

Extron electronics
Extron electronics Cable Cubby 100 installation guide

Manhattan
Manhattan 150712 instructions

AV TOOL
AV TOOL AVT-8120 instruction manual

ARX
ARX MSX 4 owner's manual

PCB Piezotronics
PCB Piezotronics 034T10 Installation and operating manual

ReelCraft
ReelCraft BA34000 M Series operating instructions

PTN
PTN SUH25E KIT user manual

Manhattan
Manhattan 150248 instructions

Crestron
Crestron SmartPresenter SPC-550 datasheet

Splitvolt
Splitvolt EGB 11-016 Quick start user guide

Hubbell
Hubbell Gleason Reel SZ-18 Installation and maintenance instructions