Storage Temperature -30°C (-22°F) ~ 70°C (158°F)
4.2"W X 4.7"H X 1.4"D
Approximately 3.0 ounces
Color and mode - selected and programmed by Control Panel's software
(pulsing, steady, etc.)
bi-color LED - Green and Red
Up to 90% RH non-condensing
HOCHIKI AMERICA CORPORATION
7051 VILLAGE DRIVE, SUITE 100
BUENA PARK, CA 90621-2268
Dimensions
Environment
Visual Indicator
(status LED)
Max relative humidity
Weight
(FRCME-4 only)
Indoor use only
(PG 1 OF 3 12/03)
DWG. # HA-06-102
PART# 1700-09959
Alarm and response: 30mA (in 20 ms.)
U.L.listed EOL device Part No. 0400-01046 (10K OHM 1/4W)
Surge current: 30mA (in 5 ms.)
No Alarm and no response: 660 A
0°C (32°F) ~ 49°C (120°F)
CAUTION !!!
If this module will be installed in an
existing operational system, inform the
operator and local authority that the system
will be temporarily out of service.
Disconnect power to the control panel
before installing the module.
Note:
Radio Frequency Interference and Electro-Magnetic Interference are sources
of noise that can adversely affect the fire alarm systems installation.
When installing fire alarm system devices, avoid placing devices or
wiring close to potential noise sources such as:
• Transmitters or antennas;
•Ballast lighting;
•Electrical motors;
•Large power transformers;
•Large machines.
Avoid running SLC circuit in the same conduit as power lines. Utilize twisted
pair and shielded wire in environments where excessive noise is expected.
INSTALLATION INSTRUCTIONS FOR DCP-FRCME-EEPROM FAST RESPOND CONTACT
MONITORING MODULE
The information contained in this installation instruction is a quick reference guide. For detailed system
information refer to the panel manufacturers installation manual. This instruction is generic and will not address
specific programming procedures.
This instruction applies to the DCP EEPROM Fast Response Contact
Monitoring Module (FRCME) which is to be connected to a DCP
Signaling Line Circuit (SLC). Typical applications are manual pull
stations, water flow devices or any dry contact alarm device, either
FRCME-P is shown in Fig. 2, the FRCME-4 is shown in Fig. 3. All
3) The address must be set on the FRCME-4 before the cover plate is
Absolute Maximum
Average Current
Maximum Current
Supply Voltage Nominal
Applied Voltage
Consumption
Consumption
End of Line Device for Input
Operating Temperature Range
CAUTION !!!
TO ENSURE PROPER
OPERATION CONNECT THIS
MODULE TO A COMPATIBLE
FIRE CONTROL PANEL ONLY.
REFER TO PANEL
INSTRUCTIONS FOR PROPER
CONNECTION AND
COMPATIBILITY.
attached (see Fig. 1).
S, SC: 41 VDC
550 A (Typical)
S, SC: 33 VDC
GENERAL DESCRIPTION:
N/O or N/C contacts can be monitored.
MOUNTING REQUIREMENTS:
The DCP FRCME Module has two mounting options. The
the modules will follow Fig. 2A & 3A for wiring connections.
NOTE: All wiring must conform to local codes, ordinances and
1) Install module wiring in accordance with the job drawings and
appropriate wiring diagram (see Fig. 2A & 3A).
2) Secure the module to a U.L. listed electrical box (supplied by
installer) as shown in Fig. 2, 3.
WIRING:
regulations.
FRCME-P PROGRAMMING CONNECTIONS
To program the FRCME-P,
connect the red alligator clip to
the S(In) wire and the black
alligator clip to the SC(In) wire
(see figure 1A). For proper
address setting, polarity must
be observed.
SER. NO. XXXXXXXXX
S5694
DCP-FRCME-P
ISSUE NO. AH-9765
SIGNALING DEVICE
FIGURE 1A.
IN-B
WHT
IN-A
SC (IN)
S (OUT)
SC (OUT)
BLK
S (IN)
RED
(BLACK)
TO PROGRAMMER
(RED)
CONNECTION AND INDICATOR
STATUS LED
FIGURE 1.
FRCME-4 PROGRAMMING CONNECTIONS
FRCME-4 MODULE ADDRESS PROGRAMMING
PROGRAMMING PLUG
(NON-POLARIZED) TO PROGRAMMER
0400-01046
PART NUMBER
E.O.L. DEVICE
U.L. LISTED
E.O.L. DEVICE
PART NUMBER
0400-01046
Maximum Distance Between
Module and EOL Device
14 AWG 1500 Ft.
16 AWG 900 Ft.
18 AWG 550 Ft.
PLACE THE FRCME-P
TYPICAL WIRING FOR N/C CONTACTS ONLY
TO A COMPATIBLE LISTED CONTROL PANEL
TYPICAL WIRING DIAGRAM EXAMPLE, CONNECTED
FIGURE 2A
DO NOT CONNECT MORE THAN ONE N/C CONTACT TO AN INPUT.
CAUTION!
0400-01046
PART NUMBER
E.O.L. DEVICE
U.L. LISTED
E.O.L. DEVICE
PART NUMBER
0400-01046
HA-06-102
(PG 2 OF 3 12/03)
PART# 1700-09959
DWG. #
EXPLODED VIEW OF MOUNTING
OPTION USING FRCME-P
(SINGLE GANG SHOWN)
MODULE INTO ANY BACK BOX
INITIATING DEVICE CIRCUIT (IDC) - NFPA STYLE B (FOR WIRING LENGTH REFER TO TABLE 1)
OUT TO
NEXT
MODULE
MODULE
NEXT
OUT TO
AND INHERENTLY POWER LIMITED.
ALL WIRING SHOWN IS SUPERVISED
ALL WIRING SHOWN IS SUPERVISED
AND INHERENTLY POWER LIMITED.
IN-A
SC (IN)
IN-B
S (OUT)
WHT
SC (OUT)
BLK
S (IN)
RED
SER. NO. XXXXXXXXX
S5694
DCP-FRCME-P
ISSUE NO. AH-9765
SIGNALING DEVICE
S
RED
S (IN)
BLK
SC (OUT)
WHT
S (OUT)
IN-B
SC (IN)
IN-A
SIGNALING DEVICE
ISSUE NO. AH-9765
DCP-FRCME-P
S5694
SER. NO. XXXXXXXXX
STYPICAL WIRING FOR N/O CONTACTS ONLY
INITIATING OR SUPERVISORY ON THE SAME MODULE
DEVICES MAY BE USED . DO NOT MIX FIRE ALARM
ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE
COMPATIBLE
U.L. LISTED
SC PANEL
CONTROL
SC
S
U.L. LISTED
COMPATIBLE
CONTROL
PANEL
S
SC
SC
FIGURE 2
TABLE 1: WIRING LIMITATIONS
HA's Sales department for proper procedure for claims and return of merchandise. This warranty is in lieu of all other warranties
specifications in any way. HA will not be responsible for any dismantling, reassembling or re-installation charges. Please contact
abused, improperly installed, altered or otherwise misused or damaged or exposed to conditions outside the products
delivery. All warranties are void and HA is not obligated to repair or replace equipment which has been repaired by others,
and to be free from defects in materials and workmanship under normal use and service for a period of one (1) year from date of
Hochiki America (HA) warrants its digital communication modules to be in conformance with it's own plans and specifications
ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE
DEVICES MAY BE USED . DO NOT MIX FIRE ALARM
INITIATING OR SUPERVISORY ON THE SAME MODULE
TYPICAL WIRING FOR N/O CONTACTS ONLY
U.L. LISTED
E.O.L. DEVICE
PART NUMBER
0400-01046
DO NOT CONNECT MORE THAN ONE N/C CONTACT TO AN INPUT.
One Year Limited Warranty
expressed or implied.
ALL WIRING SHOWN IS SUPERVISED
AND INHERENTLY POWER LIMITED.
TO A COMPATIBLE LISTED CONTROL PANEL
TYPICAL WIRING DIAGRAM EXAMPLE, CONNECTED
STYLE B (FOR WIRING LENGTH REFER
AND INHERENTLY POWER LIMITED.
ALL WIRING SHOWN IS SUPERVISED
INITIATING DEVICE CIRCUIT (IDC) - NFPA
SER. NO. XXXXXXXXX
SC-
DCP-FRCME-4
ISSUE NO. AH-9755
SIGNALING DEVICE
FIGURE 3A
SIGNALING DEVICE
S5694
ISSUE NO. AH-9755
DCP-FRCME-4
S+
IN-B
SC-
IN-A
SER. NO. XXXXXXXXX
S5694
IN-A
IN-B
TO TABLE 1)
S+
PANEL
CAUTION!
TYPICAL WIRING FOR N/C CONTACTS ONLY
COMPATIBLE
CONTROL
PANEL
OUT TO
NEXT
MODULE
U.L. LISTED
PART NUMBER
E.O.L. DEVICE
0400-01046
FIGURE 3
EXPLODED VIEW OF THE
FRCME-4 MOUNTING OPTION
COMPATIBLE
MODULE
NEXT
OUT TO
CONTROL
U.L. LISTED
ELECTRICAL BOX
STANDARD 4" SQ
PART# 1700-09959
(PG 3 OF 3 12/03)
HA-06-102
DWG. #
0400-01046
PART NUMBER
E.O.L. DEVICE
U.L. LISTED
E.O.L. DEVICE
PART NUMBER
0400-01046

Other Hochiki Control Unit manuals

Hochiki FireNET L@titude S723 Technical manual

Hochiki

Hochiki FireNET L@titude S723 Technical manual

Hochiki FireNET Plus User manual

Hochiki

Hochiki FireNET Plus User manual

Hochiki S772 Technical manual

Hochiki

Hochiki S772 Technical manual

Hochiki DCP-CLIM-2 User manual

Hochiki

Hochiki DCP-CLIM-2 User manual

Hochiki DCP-CZM User manual

Hochiki

Hochiki DCP-CZM User manual

Popular Control Unit manuals by other brands

KLINGER SCHÖNEBERG INTEC K220 Assembly and Repair Instructions

KLINGER SCHÖNEBERG

KLINGER SCHÖNEBERG INTEC K220 Assembly and Repair Instructions

ADTRAN NetVanta SHDSL quick start guide

ADTRAN

ADTRAN NetVanta SHDSL quick start guide

VAT 11136 E01/08 Series Installation, operating,  & maintenance instructions

VAT

VAT 11136 E01/08 Series Installation, operating, & maintenance instructions

Texas Instruments DRV10974 EVM user guide

Texas Instruments

Texas Instruments DRV10974 EVM user guide

ZURN WILKINS 950LF Installation, Testing, Maintenance Instructions

ZURN

ZURN WILKINS 950LF Installation, Testing, Maintenance Instructions

Lutron Electronics LQR-WPM-6D Installation and operation guide

Lutron Electronics

Lutron Electronics LQR-WPM-6D Installation and operation guide

Pulsar MSRD 1024 manual

Pulsar

Pulsar MSRD 1024 manual

Voith WSR-D16214 instruction manual

Voith

Voith WSR-D16214 instruction manual

Texas Instruments DLP DLPC4420AEVM user guide

Texas Instruments

Texas Instruments DLP DLPC4420AEVM user guide

Cypress CAPSENSE CY3280-BSM quick start guide

Cypress

Cypress CAPSENSE CY3280-BSM quick start guide

ELPRO ECOLOG-PRO 2PTR Operation manual

ELPRO

ELPRO ECOLOG-PRO 2PTR Operation manual

SMA MD.485-US-40 Quick reference guide

SMA

SMA MD.485-US-40 Quick reference guide

Emerson Vanessa 30000 Series Installation, operation and maintenance manual

Emerson

Emerson Vanessa 30000 Series Installation, operation and maintenance manual

Flowserve Valtek MaxFlo 3 Installation operation & maintenance

Flowserve

Flowserve Valtek MaxFlo 3 Installation operation & maintenance

Feig Electronic ID ISC.MRMU102-A installation manual

Feig Electronic

Feig Electronic ID ISC.MRMU102-A installation manual

KORDT TRANSICORD 10480 V2 Manual and Technical Documentation

KORDT

KORDT TRANSICORD 10480 V2 Manual and Technical Documentation

GEM CleanStar C60 HPW Installation, Operating and Maintenance Instruction

GEM

GEM CleanStar C60 HPW Installation, Operating and Maintenance Instruction

Honeywell DCCC6500 quick start guide

Honeywell

Honeywell DCCC6500 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.