INTRODUCTION
Your EVIE Sensor communicates to the WX8 to automatically disable your
watering schedules after 5mm of rain, reducing your water usage in the process.
The sensor uses two electrodes (A) connected
to a Radio Frequency (RF) Transmitter.
When water begins to fill the sensor, the circuit between the two electrodes
completes, and the RF Transmitter can wirelessly communicate to the WX8
to stop watering. After the water in the sensor evaporates, the circuit is once
again disconnected, and the RF Transmitter tells the WX8 it can continue with
your watering schedules. The sensor holds a maximum of 25mm of rainfall.
Your EVIE Sensor regulates how quickly watering will resume
after rain. This comes from the amount of rainfall collected,
and how quickly it evaporates in heat or wind.
®When water fills above the internal electrodes (A), the
EVIESensor will detect the moisture and any automatic
watering starts will be disabled in Holman Home
®As the water evaporates and the water level drops below the centre weir(B),
the sensor will report back to your WX8 as dry, and any automatic watering
starts will be reinstated in Holman Home
PAIRING TO THE WX8 IRRIGATION CONTROLLER
®Your EVIE Sensor should
already be paired with your
WX8Irrigation Controller
1. Check the DEVICE INFORMATION(C)
page in Holman Home to ensure
your EVIESensor is paired
to the WX8 correctly and the
battery is in good condition
2. If your EVIE Sensor does not appear
to be paired to your WX8, please see
our pairing instructions overleaf
WX8RS and WXE001 EVIE Rain Sensor
User Guide
Please visit the following for additional support:
https://www.holmanindustries.com.au/product/wx8-wifi-irrigation-controller-with-evie-sensor/
https://www.holmanindustries.com.au/product/evie-evaporative-intelligent-eco-rain-sensor/
INSTALLATION
®To communicate to the WX8IrrigationController, the
EVIE Sensor needs to be installed no more than 50 metres
from the controller with a clear line of sight
®The EVIE Sensor needs to be mounted horizontally on a gutter
and attached with the wing nut screw (D) provided
®Choose a gutter location where the EVIE Sensor will not be
knocked by surrounding trees or by potentially strong wind
®Use the elbow screw (E) to level the EVIE Sensor on your gutter
CHECKING YOUR EVIE SENSOR
To check if your EVIE Sensor is working, please follow these steps:
1. Fill the sensor with water
2. Stand at ground level, holding the
sensor under your gutter near the
intended installation point
3. You will need to wait up to a minute
for HolmanHome to detect moisture
through the EVIE Sensor
4. HolmanHome should currently
report (F) that the EVIE Sensor
is detecting and that automatic
watering starts have been disabled
5. Once HolmanHome has confirmed it is
working correctly, empty the water and
install the sensor in the desired location
A
B
A
C
D
E
F
SCAN FOR SUPPORT
WXEV001
WARNING!
KEEP NEW OR USED BUTTON/COIN
BATTERIES OUT OF REACH OF CHILDREN
Swallowing or placing inside any part of the body can lead to
chemical burns, perforation of soft tissue, and death. Severe
burns can occur within 2 hours of ingestion. Seek medical
attention immediately if ingested or placed inside the body.
Contact the Australian Poisons Information Centre
for 24/7 fast, expert advice:  13 11 26
Refer to your local government guidelines
on how to correctly dispose of button/coin batteries.
WX8RS and WXE001 EVIE Rain Sensor
User Guide
Please visit the following for additional support:
https://www.holmanindustries.com.au/product/wx8-wifi-irrigation-controller-with-evie-sensor/
https://www.holmanindustries.com.au/product/evie-evaporative-intelligent-eco-rain-sensor/
TROUBLESHOOTING
If for some reason the EVIE Sensor has been disconnected from your WX8,
Holman Home will show this in the DEVICE INFORMATION screen (F).
The following instructions highlight how to re-pair your EVIE Sensor to the WX8:
1. Bring your EVIE Sensor to your WX8 irrigation controller so
that you can operate both devices simultaneously
2. On the EVIE Sensor, remove the rubber plug (G) on the underside
and check there are two CR2032 batteries (H) installed
3. On your WX8, turn the dial to OFF
4. Press and hold START for 5 seconds until the LEDs of ZONE 1 and 2
both flash, alternating between red and blue (for 20 seconds only)
®The next step must be completed in the first 20
seconds while the LEDs are still flashing
®If you run out of time it is possible to attempt the process again
5. On the EVIE Sensor, press and hold the internal button(I)
until the WX8 LEDs of ZONE 3 and 4are alight
®If the pairing succeeds, these LEDs will be blue
®If the pairing fails, these LEDs will be red
6. After pairing is successful, on the WX8, turn the
dial to RUN to exit the pairing mode
7. Wait at least one minute for the Holman Home to show EVIE Sensor
is connected to the WX8 in the DEVICE INFORMATION screen (J)
8. Replace the rubber plug back into EVIE Sensor (G)
9. Follow the instructions for CHECKING YOUR EVIE SENSOR as listed overleaf
10. Re-install your EVIE Sensor as per the INSTALL ATION instructions overleaf
®For additional pairing help, please visit
https://www.holmanindustries.com.au/ to access additional
support pages or contact our Customer Service team
F
F
G
J
I
H
H
SCAN FOR SUPPORT
WXEV001

This manual suits for next models

2

Other Holman Accessories manuals

Holman QCS3-950HB User manual

Holman

Holman QCS3-950HB User manual

Holman EVIE WX8RS User manual

Holman

Holman EVIE WX8RS User manual

Holman WXMS User manual

Holman

Holman WXMS User manual

Popular Accessories manuals by other brands

Counteck Virtual Trainer Multisport user manual

Counteck

Counteck Virtual Trainer Multisport user manual

Niceboy ION user manual

Niceboy

Niceboy ION user manual

Omron FQ-CR10 Series instruction sheet

Omron

Omron FQ-CR10 Series instruction sheet

Heidemann HX Clock Operation and installation instruction

Heidemann

Heidemann HX Clock Operation and installation instruction

Siemens Milltronics MD-36 instruction manual

Siemens

Siemens Milltronics MD-36 instruction manual

STONEX SC200 user manual

STONEX

STONEX SC200 user manual

Manitowoc 1480279 installation instructions

Manitowoc

Manitowoc 1480279 installation instructions

AIRVERSA AN1 user manual

AIRVERSA

AIRVERSA AN1 user manual

Apogee Instruments S2-431 owner's manual

Apogee Instruments

Apogee Instruments S2-431 owner's manual

tau FOTEC Series Instructions and warnings

tau

tau FOTEC Series Instructions and warnings

Vega VEGASON 61 operating instructions

Vega

Vega VEGASON 61 operating instructions

Goji G6PBT2615 instruction manual

Goji

Goji G6PBT2615 instruction manual

SkyBound ANCHOR KIT Assembly and installation manual

SkyBound

SkyBound ANCHOR KIT Assembly and installation manual

Gemini 7709 Installation and use manual

Gemini

Gemini 7709 Installation and use manual

COOLFORT CF-0233 Manual instruction

COOLFORT

COOLFORT CF-0233 Manual instruction

Monzana 109603 instructions

Monzana

Monzana 109603 instructions

Schweitzer Engineering Laboratories SEL-734W Field reference guide

Schweitzer Engineering Laboratories

Schweitzer Engineering Laboratories SEL-734W Field reference guide

Lafferty 976260-24V Installation & operation instructions

Lafferty

Lafferty 976260-24V Installation & operation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.