Portable Ultrasonic Water Depth Meter---HLU-SF
1. Profiles:
Holykell HLU-SF ultrasonic water depth meter is used in reservoirs, lakes, rivers or shallow sea water
etc. The main principal is to place ultrasonic transducer above water or in water and use ultrasonic spreading
in the water to get calculated water depth by instrument. This instrument adopts the international advanced
technology, equipped also with water depth measurement functions, control functions, data transfer functions
and man-machine communication capabilities. This instrument is a water depth measurement instrument of
ultrasonic receive and dispatch sensor, servo circuit, temperature compensation, salinity compensation and
compensation circuit unit, monitor, and control signal output and serial data or analog output unit (optional).
Its main advantages are high reliability, long life, easy access, simple operation, accurate measurement of
features and less-maintenance, it has already been widely used in the hydrographic survey, hydropower
plant, reservoir area, shallow seas, lakes, rivers, surveying, environmental waters monitoring etc.
■ the water depth meter has different compensation of water quality and water sound temperature for sea
water, river water, and cost performance are surpassed import type.
■Standard configuration of instrument: 1. Sensor; 2. handheld instrument, high-capacity lithium-ion battery
(built-in), 3.Dedicated charger. Can be selected a variety of portable protective box when you ordering.

MANUAL
HOLYKELL TECHNOLOGY COMPANY LIMITED
Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: [email protected] Website: Http://www.holykell.com
Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of China
2. Instrument composition and port definition
Charge Port
Signal Output and wiring
Display
Keyboard
◆Front
Wall-hung
Charge Port
Nameplate
Signal Output
Sensor Port
◆Back
Sensor Lead
Connect thread
d
Sensor
Specialcable
10m
Sensor.connection
vvttvvvtvvvfffffffffco
nne
con
nec
tion
con
nect
ion

MANUAL
HOLYKELL TECHNOLOGY COMPANY LIMITED
Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: [email protected] Website: Http://www.holykell.com
Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of China
3. Specifications:
Maximum Range: 100m, 200m, 300m (default 100m, can be customizable )
Detection accuracy: ±0.5% FS (based on 20 °C water standard plane)
Blind Zone Detection: ≤ 500 to 800mm (at F0 ~ FS, according to the sensor range)
Draft depth: ≥ 500mm
Detection methods: of 0.1 ~~ 100Hz / s (without special requirements, 1Hz / s is default)
Beam angle: 18 °±2 °
Operating frequency: 50kHz~200kHz (based on matching sensor dependent)
Output signal: 4 ~20 mA, RS485 (can be customizable)
Instrument operating parameters:
Dispaly: LCD multi-information screen+ backlight , water depths four-digit +15 field data display
Display resolution: d = 1mm/1cm (user settings)
Keyboard: five touch of a button
Operating Temperature: 0 ℃~ 50 ℃; Storage temperature: - 20 ℃~ 70 ℃
Operating Humidity: ≤ 80% RH non-condensing (instrument)
Storage humidity: ≤ 70% RH non-condensing (instrument)
Dimensions: 235 ×115 ×70mm
Operating voltage: built-in rechargeable lithium battery, standby time of approximately 6 hours intermittent
Sensor operating parameters:
Application medium: fresh water, sea water (determined when you ordering)
Operating temperature: 0 ℃~ 40 ℃temperature compensation automatic
Sensor lead: 10meters, lead is done acoustic matching before delivery.
Weight: Net.weight≤ 2.5Kg, Gross Weight ≤ 3.5Kg with suitcase packing
Package Size: 90 ×16 ×24cm (containing the suitcase)
Installation: handheld portable; 1 inch threaded mounting of sensor
Dedicated charger: Input voltage: 110 to 240VAC 50/60Hz
Output voltage: 12.6VDC 350mA
◆◆Special Caution!
The device contains LI-CELL, only applicable with the allocated charger and storage between 0 ~ 40 ℃;
Please keep away from fire, heat, collision, water and short pass, otherwise explosion might happen! The
battery and charger are consumables, without of warranty; when the green indicator light, that means the
battery is fully charged, please unplug the charger timely.
The range based on the area of beam projection corresponding distance and steel smooth plane target
perpendicular to the sensor axis, otherwise may reduce range or can’t be measured without good reflect
target.

MANUAL
HOLYKELL TECHNOLOGY COMPANY LIMITED
Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: [email protected] Website: Http://www.holykell.com
Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of China
4. Instrument display and keyboard definition:
■Instrument display:
■Keyboard definition:
Addend key: press this key and add "1" of blink digit number then determine the
decimal point in setting status, when you need negative numbers operation, Press
to tune out or remove the negative sign; Press the key for 5 seconds in working
status you can turn off the display and access a power saving mode.
Flip over key: when press this key in working status will display P1, then press shift
key to enter P1 menu to set or read parameters, each time you press the page key
will display the next menu, total item is eleven.
Shift key: press this key to shift, when each digit has been set then press the key
till each digit all flashing is mean setting parameters stored in the operation; when
under show off power-saving mode, press the key can open the display; while
press this key for 5 seconds can turn on the backlight in working condition, press
the key for five seconds again will close the backlight.
Boot key: Press to boot, power indicator will light.
Power-off key: Press this key, POWER is off.
Show Value(m)
Netaddress indicate
Serial port communication
Output display of analog or temp
Analog output indicate
Baud rate indicate
Switching value output
示
Fault report and type indicate

MANUAL
HOLYKELL TECHNOLOGY COMPANY LIMITED
Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: [email protected] Website: Http://www.holykell.com
Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of China
5. Menu operation:
Menu
Access
Press flip over key in working status will display P1, press the shift key again, will enter
P1 menu, the menu is as follows:
L1 ××××
The first limit alarm output: no use.
L2 ××××
The second limit alarm output: ditto.
L3 ××××
The third limit alarm output: ditto.
L4 ××××
The fourth limit alarm output: ditto.
E××××
Draft depth Settings, set one half of the negative distance between the surface to depth
sensor emission face into the menu, it will automatically count the draft depth when the
instrument display depth of water.
Parameter setting method: press shift key to shift, press addend key to flicker a addend,
input necessary numerical, press the shift key when flicker in the bottom, when all the
four parameters setting don’t flicker any more, press flip over key to save the setting
parameters and enter the next menu.
N××××
Salinity value Settings, when salinity value is 0 for fresh water depth; While used in sea
water, output corresponding value according to the current salinity of water. Such as
when salinity is 3.6%, N should be 0.036 output.
Parameter setting method: ditto.
d×
The machine address number Settings, the function is special for multiple machines on
line with upper computer communication, virtual value is 1 ~ 99.
Parameter setting method: press the addend key plus one once, press the shift key
minus 1 once, the default value is 0.
bo ×××
Communication Baud rate setting, Baud rate is as follows: 0.3, 0.6, 1.2, 2.4, 4.8, 9.6,
19.2 Kbps.
Parameter setting method: press the addend key to increase, press the shift key to
reduce.
P×
Emission power Settings, effective value is 0 ~ 15, set according to the working
conditions (taking stable and accurate for moderate, generally according to the factory
set point).
Parameter setting method: ditto.
C××××
Temperature of current measured water. This menu is only for observation, can't be
modified.
CA××××
The output analog value of current measured depth.
This menu is only for observation, can't be modified.
Exit menu
When parameters has been set up completely, press flip over key for 3 seconds, then
will exit P1 menu and enter the normal working state.

MANUAL
HOLYKELL TECHNOLOGY COMPANY LIMITED
Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: [email protected] Website: Http://www.holykell.com
Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of China
6. Installation dimension of sensor:
【The following picture is the schematic diagram of sensor body, the final size and appearance is subject to
the real goods】
◆Installation suggestion: sensor installation should consider the protection requirements of the cable, we
suggest to make cable through the pipe, then connect pipe to sensor connector, other external fittings can
connect the pipe directly. In order to avoid cable fracture to cause permanent damage of sensor, cable
should be avoid under the stress of the installation of fittings.
7. Application Notice:
1. Ultrasonic water depth sensor is precision instrument, it must be power on more than 5 minutes before
using.
2. Ultrasonic water depth sensor can only work in the water. It can't work in the air.
3. It needs input N value( salinity value) in the P1 menu when it works in the sea water.
4. Ultrasonic water depth sensor has been matched with instrument circuit, can’t be interchangeable. In order
to improve the service life of instrument, please build awnings above the water depth sensor when it works
outdoor, don't put the ultrasonic water depth sensor in the environment of long-term sunny or raining.
5. Transmitting power can’t be set too large or too small, otherwise it won’t be able to work normally
6. Ultrasonic water depth sensor has blind zone, the data display is random within the blind zone.
7. The sensitivity is very high of instrument, so there can't have too strong noise and electromagnetic
interference nearby when use it. It will affect the stability of the instrument and even shorten the service life
of the instrument if flow momentum is big, temperature and humidity isn’t within the regulation range,
temperature change too fast and instrument surface is with moisture condensation etc.
8. Strictly prohibit putting LCD products into high or low temperature environment.

MANUAL
HOLYKELL TECHNOLOGY COMPANY LIMITED
Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: [email protected] Website: Http://www.holykell.com
Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of China
8. Communication protocol of Serial port:
【Standard Baud rate】
Half duplex asynchronous mode, Baud rate can be set freely from 600 to 19200 BPS.
MC version communication format (standard Baud rate).
1: Host machine: After sending address (1 ~ 64)of binary code then inquire receiving data.
2: Slave: to response by interrupt mode, each frame sending 21 byte.
Sending data Sequence of Slave:
First 5 bytes is water depth value (5 bytes ASC code, the unit is meter)
The sixth to twentieth bytes is production testing code (no business of the user); the twenty-first byte is
"accumulation sum" verify word!
★For example: some time the superior machine receive a frame level data which sent by HLU-SF as follows,
30 2E 35 30 31 31 31 33 2E 37 36 31 41 5C 2D 86 3F 00 4D B5 E6
- - - - - depth value = 0.501m(30 2 E 35 30 31);
- - - - - 6-20 bytes is production testing code;
- - - - - E6 is accumulating sum
To enable users to enjoy better quality and frontier science technology achievement, HLU-SF products will
continue to upgrade, -- -- -- -- - if there is a technical subject to change without prior notice)
9. Frequently questions and treatment methods:
Difficult questions
Possible reason of difficult questions
Treatment methods
No display after press
Bootkey or measurement
is not normal, sensor
without sound…
1.Built-in lithium battery power is not
enough
2.Built-in lithium battery is failure
1. To charge instrument in time.
2.Need to replace built-in lithium
battery, please contact the supplier
of ultrasonic water depth instrument.
(be sure not to power on and
operation by yourself)
Sensor has sound,
but without display...
1.Instrument into close display energy
saving mode
2.Display chip or screen has been
damaged
1.Deep press the shift key to open
display
2. Contact supplier of ultrasonic
water depth instrument.
With display, but digital
can‘t change according
to distance surface, and
the sensor without
1. Input working voltage is too low, the
sensor of ultrasonic water depth gauge
does not work;
2.Sensor of ultrasonic water depth
1.Power supply according to the
required voltage.
2. Contact manufacturer of ultrasonic
water depth instrument.

MANUAL
HOLYKELL TECHNOLOGY COMPANY LIMITED
Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: [email protected] Website: Http://www.holykell.com
Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of China
sound...
gauge or power driver has been
damaged.
Has display and sound,
but the measuring
numerical value
disorderly jump, or
numerical value is not
change according to the
distance change...
1. The depth of water meter installed too
inclined, reflection is not good;
2. The power setting too big, and then
caused remaining vibration or diffraction
is big;
3. Don't properly used in air
environment;
4. There are two or more than two sets
of water depth meter are working in
close, causing echo interference;
5. The water has too big electromagnetic
interference; 6. Gain parameters has
been modified artificially.
1. Adjust the sensor’s axis and make
it perpendicular to the water surface
2.Generally, under 20 m range,
power P is about 10, above 30 m
range, power P is about 10 ~ 15
(also have special);
3.Put the sensor into water to
measure;
4. Move another instrument to the
distant measurement area;
5.Shielding interference; 6.Contact
the manufacturer of ultrasonic water
depth meter
Sensor has sound and
display horizontal line
"----"
1.Depth of water meter’s range is small,
but the working range is too big;
2.The application range is not wrong, the
application of the water environment
turbidity is too large or bed no reflection
conditions, and can't get the echo;
3. Setting of Power P is too small or too
large.
1. Adjust the working range of water
depth meter to actual range;
2. Adjust application environment to
appropriate water with reflection
plane;
3.Access to user menu the depth of
water meter user menu and change
transmitted power, increase or
decrease P until display is
stable.
The sensor has sound
and the error of water
depth value error is more
than ten centimeters...
1.There is a large obstacles in water
under sensor, which cause reflection
wave;
2.The installation is too nearby the
shore side, wave distinguishes is reflex
midway;
3.Check whether it is correct of "N
value" setting;
4.Check whether it is normal of
temperature "C" value.
1.2. Change installation places.
3.Setting correct N value (please
refer to the instruction);
4. If the temperature difference is
more than ten degrees, it means the
sensor is damaged, please contact
supplier timely.
1.The range migration parameters FX
1.Contact supplier;

MANUAL
HOLYKELL TECHNOLOGY COMPANY LIMITED
Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: [email protected] Website: Http://www.holykell.com
Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of China
4~20mA output is
abnormal: it is too high or
too low, display 10 mv ...
has been illegally modified;
2.The output fine adjustment
parameter AX has been illegally
modified;
3. Low battery.
2. Contact the distributor or the
manufacturer to set correct
parameter;
3. Charging in time.
The water depth meter of
serial output and the
upper host or PC cannot
be online...
1. The setting of extension baud rate is
not consistent with the setting of host
machine;
2.Extension address is 0 or excess
range;
3.Twisted-pair cable is too thin,
capacitance is too big of wires;
4. 232-485 converter is abnormal of PC.
1.Check the host and extension set,
adjust Baud rate to be consistent;
2.Check host’s Ar value, make the
extension address does not
overflow;
3. Using ≥Φ2 mm twisted-pair
cable;
4. Consulting the manufacturer of
serial converter or replace the serial
converter.
Table of contents
Other HOLYKELL Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Halma
Halma Ocean Optics LASER-785-IP-LAB Installation and operation manual

itaia
itaia FM-6 operating manual

ASA Electronics
ASA Electronics AP-2 Product Introductions

THORLABS
THORLABS Redstone OSA305 user guide

Ahlborn
Ahlborn ALMEMO 2590-2A operating instructions

Vortran
Vortran Stradus VersaLase user manual