manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HoMedics
  6. •
  7. Personal Care Product
  8. •
  9. HoMedics Duo Pro User manual

HoMedics Duo Pro User manual

IPL-HH160-GB
INSTRUCTION MANUAL
PERMANENT HAIR REDUCTION 
FACIAL SKIN REJUVENATION
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 1
3
2
3
1
4
7
6
3
5
quick s ar guide
Hair removal
choose your desired treatment – skin rejuvenaion or hair removal.
Hair removal: atach hair removal cartridge.
make sure the skin in the area you wish to treat is shaved, clean and dry
connect the power lead to duo and plug into the mains – the blue/white skin level
indicator lights will lash on and turn of and the green status light will illuminate to
indicate the power is connected
press the qbuton to switch on the duo.
press the qbuton to select an appropriate level for your skin tone. It is
recommended to carry out a skin test before irst use on each area you wish to treat
(see page 5 for details).
hold the device against the treatment area, making sure the yellow treatment
window is in full contact with the skin. The green status indicator will stop lashing
when good skin contact is made and the duo is ready to lash.
for levels 1 - 3 (AFT FREEGLIDE™), hold the green trigger buton down and glide the
duo across your skin. for levels 4 & 5 (IPL single shot) press the green trigger buton,
hold the duo against the skin and wait for the lash - then move to the next
treatment area.
Please carefully read the full instrucions and safety warnings before using Duo.
2
1
3
4
5
6
7
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 2
W AT ARE IPL AND AFT?
Duo is a home-use device for the permanent reduction of hair growth based on Intense Pulsed Light (IPL) and
Advanced Fluorescence technology (AFT) that is found in salons across the globe. It works below the skin's
surface and does not involve any cutting or pulling, reducing hair growth with minimal pain.
Duo gives you the power to fight unwanted hair growth delivering long term results for perfectly smooth
skin. The combination of both Intense Pulse Light (IPL) and Advanced Fluorescence Technology (AFT) in a
single device provide highly flexible treatments that can be tailored perfectly to different parts of the body
and to different skin tones. Choose between Freeglide AFT which delivers up to 1 pulse per second for fast
and easy treatments that are comfortable even on sensitive skin or single shot IPL treatments with the benefit
of additional control when using higher power.
Please read all instructions and safety precautions carefully prior to use.
• Duo should ideally be used on the legs, underarms, bikini line, chest, stomach, arms and on the face below
the cheek bones (not for use on the face by men).
• Do not use the device over mucous membranes i.e nose and ears.
• Do not use the device over piercing or any metal items such as earrings or jewellery.
• Do not use the device on tanned skin during 4 weeks after sun exposure (more than 15 minutes in direct
sunlight without protection) as this can cause serious burns or skin injury.
• Avoid more than 15 minutes of direct sun exposure for at least 2 weeks post treatment. If recently treated
skin is exposed to sunlight in this period of time, make sure to apply SPF 30 or higher sunscreens.
• Do a spot test on a small patch of skin in the intended treatment area, 48 hours prior to first use of the IPL
(see spot test page 5).
• Do not use the device on naturally dark skin (see guide on box and inside back cover).
• Keep out of children's reach.
• The device is to be used for hair reduction purposes only. Do not use it for any other purpose.
• Use Duo only according to the instructions for use.
WARNINGS AND SAFETY PRECAUTIONS
When shouldn’t Duo be used?
• Pregnant or nursing women must avoid the use of the device.
• Do not use the device if you have skin cancer or on areas at risk of malignancy.
• Do not use the device if you suffer from epilepsy.
• Do not use the device if you are/were under radiation therapy or chemotherapy within the past 3 months.
• Do not use the device if you have an active implant such as a pacemaker, insulin pumps, or similar devices.
• Do not use on damaged or broken skin or if you have a history of erpes or Psoriasis outbreak in the
treatment area.
• Do not use if you suffer from kelodial scar formation.
• Do not use if you have taken Tetracycline antibiotics within the last two weeks.
• Do not use if you have been taking medication with the following active ingredients within the last two
weeks: Retinoids, Accutane and Retin-A.
• Do not use the device if you are photosensitive or have other diseases related to light sensitivity.
• Do not use if you suffer from metabolic conditions, such as diabetes.
• Do not use if you have had a skin peel or other skin resurfacing procedure within the last 6 – 8 weeks.
• Do not use the device if you were exposed to strong sunlight or an artificial tanning machine during the
past 30 days.
• Do not use the device if you have dark spots such as large freckles, moles or blisters on the treatment area.
• NEVER use flammable liquids such as alcohol or acetone to clean the skin before using the device.
• Do not use the device on the face above the cheek line; around the eyes, eyebrows or eyelashes as this
could cause serious eye damage.
• Do not use the device over mucous membranes as in the nose and ears
3
GB
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 3
4
GB
• The device should not be used on tattoos, permanent make up and intimate body parts such as nipples,
genitalia or around the anus.
• If you see extreme redness of the skin, blistering, or burns STOP USE IMMEDIATELY!
• Do not look directly at the light coming from the applicator and the lamp cartridge.
• Do not use the device for any purpose other than hair reduction.
• Use of the device may cause temporary skin colour changes.
• Do not apply continuous pulses (one after the other) with the applicator on any one spot on your skin during
treatment. Doing so causes extensive heat to build-up and may result in possible skin damage or scarring.
• Do not return to a previously treated spot until 10 seconds have passed. Doing so causes extensive heat to
build-up and may result in possible skin damage or scarring.
• Do not open or repair the device as it contains dangerous electrical components which may cause physical
damage.
• Do not use the device with any additional accessories that are not part of its intended use.
• Always disconnect the power cord from the wall electrical outlet after use.
Note: complete power shutdown is achieved only when the power cord is unplugged.
• Do not use the device where it can come into contact with liquids (wet environment). This can cause
electric shock.
• If the device is dropped into liquid, unplug it immediately. Do not remove the device from the liquid until
unplugged – wait at least 2 minutes to remove. Do not use the device again, contact the customer service
centre.
• Do not use the device if any parts show signs of damage. This may result in injury.
• Always keep the device away from the hair of your head to avoid accidental burns.
• Always keep the device away from objects other than the skin while treating (e.g. clothes, brushes, wires,
cords, laces, etc) to avoid accidents.
• Do Not rinse any components of the device with any kind of liquid to avoid damaging the device.
CAUTION:
• This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities
unless they have been instructed by a person responsible for their safety, according to the instructions for
use.
• This appliance can be used by children aged from 14 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user maintenance shall not be made by children without
supervision. The effects of use on under 18s has not been tested and is unknown.
•KEEP OUT OF CHI DREN'S REACH.
WARNING!
Do not use this appliance near bathtubs, showers, basins or other vessels containing water.
WEEE explanation
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from uncontrolled
waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the retailer where the product was
purchased. They can take this product for environmental safe recycling.
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 4
5
GB
PRIOR TO USE
Duo set-up
1. Remove all components from the box (applicator and power adaptor).
2. The replaceable lamp cartridge comes assembled to the product. Ensure it is correctly fitted.
3. Plug the power cord to the applicator handset.
4. Only after connecting the power cord to the applicator handset, insert the plug into the electrical outlet.
5. On connecting the power, the blue/white skin level indicator lights will flash on and turn off, the green
status light will then begin flashing.
SPOT TEST – HAIR REMOVA
The spot test is intended to determine your skins reaction to the AFT/IPL treatment and help you select the
optimal energy level for each treatment area.
Do a spot test on each area you intend to treat 48 hours prior to the full treatment.
Note: If using the facial hair removal cartridge (available for purchase separately) the test should be done in a
hair-free area such as below the ear or the side of the neck.
1. Prior to use, make sure your skin is shaved, clean and dry (free of any residue such as powders, creams,
make-up, anti-perspirants or deodorants).
Warning! NEVER use flammable liquids such as alcohol or acetone to clean the skin before using the IPL
device.
2. Set up the device following the instructions above.
3. Place the applicator treatment window on the required test area with full contact to the skin.
PARTS IDENTIFICATION
Power Button
Power adaptor socket
Pulse button
Level Indicator lights –
illuminated blue for AFT
(level 1-3) / illuminated
white for IPL (level 4 & 5)
Treatment Window
Status Indicator LED –
illuminates green
Skin Rejuvenation cartridge
(select models only)
Facial Hair Removal cartridge
(available separately)
Replaceable Lamp Cartridge
Hair Removal cartridge
(select models only)
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 5
Body Area Comfortable Energy Level
4. The device sets itself on the lowest energy level. Deliver the first pulse, on energy level 1, by pressing the
pulse button. You will see a bright flash, hear a popping noise and you may feel a mild stinging or/and heat
sensation.
5. Remove the applicator from the skin and place it on the next spot of the test area.
6. Use the power button to increase the energy level by 1. The energy level lights will light up blue (or white
for levels 4 and 5) according to the selected energy level. Deliver the second pulse, on energy level 2, by
pressing the trigger button.
7. Only if you feel comfortable repeat steps 5 to 6 until you have reached the maximum energy Level of 5.
Stop the test once you do not feel comfortable, increasing the energy level increases the risk of adverse
effects. If you see adverse effects such as severe redness or blistering stop the test immediately.
8. Wait 48 hours and examine the tested area. If the skin in the test area seems normal (no response or mild
redness) you can proceed with a full treatment in the highest comfortable energy level you tested.
If you see extreme redness, swelling or blistering, even in the low energy level settings do not do the full
treatment in that area.
Note: Do not treat full areas in energy levels you have not tested before.
Do not treat the tested area for at least 1 week after the spot test is done. Use the table below to make a note
of the energy level that suits you for different areas you wish to treat.
6
GB
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 6
7
GB
INSTRUCTIONS FOR USE  AIR REMOVAL
N.B. It is recommended to carry out the Spot test (page 5) at least 48hrs prior to treatment to choose a
safe treatment level for your skin.
1. Prior to use, make sure your skin is shaved, clean and dry (free of any residue such as powders, creams,
makeup, antiperspirants or deodorants).
Warning! NEVER use flammable liquids such as alcohol or acetone to clean the skin before using Duo.
2. aving followed Duo set-up steps above, press the power button qto turn on the device. The LED
indicator for level 1 will illuminate.
3. The device sets itself on the lowest energy level. Use the power button to increase the energy level to reach
the level determined in the spot test and according to your convenience. The energy level lights will light
up blue (AFT)/white (IPL) according to the selected level.
4. Place the applicator treatment window on the required treatment area with full contact to the skin (the
applicator will not trigger a pulse if there is not full skin contact and the green ‘ready’ indicator light will
stop flashing but remain illuminated when the device is in good contact with the skin).
5. Dependent on the energy level selected the device can be used in two ways:
Freeglide method (AFT): This is the method used on energy levels 1-3. old the pulse button down
continuously and slowly move the device over the skin maintaining constant contact. In this mode it is
necessary to repeatedly pass the device over the same area up to 5 times to ensure maximum coverage
N.B. The higher the level the slower you will need to glide the device. This is because the more energy
released, the slower the pulse rate.
Single shot method (IP ): This is the recommended method to use for high energy levels 4-5. With the
treatment window in contact with the skin, press the trigger button and wait for the flash. Only shoot once
before moving the device to the next treatment area ensuring there are no gaps or overlaps in the treated
area. Wait for the status indicator LED to stop flashing (up to 3.5 seconds) before pressing the pulse button
again.
During both treatment methods you will see a bright flash, hear a popping noise and may feel a mild
stinging and/or heat sensation.
6. Repeat steps 4 and 5 until all the chosen area has been treated. The product should not be used for more
than 30 minutes at one time. After 30 minutes are up, switch the device off and unplug from the wall.
NB: If the device is left on but not used for approximately 3 minutes it will automatically switch itself off. If
this has happened, press the power button to turn the device back on.
Facial treatment
Only use the facial adaptor to treat the face (*available for purchase separately)
The facial skin is a sensitive area that requires special care and caution. Make sure you follow all instructions
and safety precautions carefully in order to avoid adverse effects. To maximise safety, both AFT and IPL power
levels will function in single shot mode for greater control when treating the face. The facial adaptor includes
a pressure sensor, the treatment window must be in good contact with the skin otherwise the device will not
flash. Start the treatment on level 1 and increase only if the treatment is comfortable.
The facial cartridge is available to buy separately, it is recommended that you use this when performing facial
treatment as it is specially designed to fit smaller areas such as the top lip.
Fitting the facial adaptor (*sold separately)
The facial adaptor attaches to the product in the same way as the standard cartridge. See page 10 for
instructions.
Warning!
1) Do not use the device on the face above the cheek line, around the eyes, eyebrows or eyelashes as this
could cause serious eye damage.
2) Protective goggles are included with the facial cartridge (sold separately). These should be worn to
decrease discomfort when treating near the eyes.
3) Do not use the device to treat hair growth in the nose and ears (see page 3).
4) Make sure you do a Spot Test 48 hours prior to treatment. The Spot test should be done in a hair-free area
such as below the ear or the side of the neck to determine the energy level.
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 7
8
GB
Warning!
5) Do not treat the tested area for at least 1 week after the spot test is done
6) Use a mirror to help you place the applicator correctly on the treatment area.
7) Follow the instructions for use (see page 6) with additional care to the following specific area instructions.
Note: Facial air may be hormonal and as such, it can take more sessions to achieve a permanent hair
reduction.
Upper ip Treatment
Place the Applicator treatment area as indicated in the picture.
Repeat up to 5 times on each area.
Avoid the nostrils and lip, as these areas are more sensitive. If
necessary mask the lips with a sheet of paper.
You can “fold” your lip inward or press the lips together to achieve a
better spread treatment area.
Cheek and Jaw treatment
Place the Applicator treatment area as indicated in the picture.
Treat each area up to 5 times, moving from one side of the jaw/cheek to the other.
Neck and chin treatments
Place the Applicator treatment area as indicated in the picture. Treat each area up to 5 times, moving from
one side of the neck/chin to the other.
Note: The skin on lower third of the neck is more sensitive.
For Male users
It is not recommend to use the product for facial treatment as this may change the facial characteristics and
result in a feminine look.
Note: Premature ageing characteristics can emerge due to complete loss of facial hair of men.
Post treatment care for facial treatment
Apply a calming lotion such as Aloe Vera.
Avoid using peeling and bleaching creams or products for at least 24 hours as this irritates the treated skin.
Avoid more than 15 minutes of direct sun exposure for at least 2 weeks post treatment. If recently treated
skin is exposed to sunlight in this time period, make sure to apply SPF 30 or higher sunscreen.
Do not wax or pluck hairs from treated areas.
Remember! It may take up to 2 weeks for the hair to grow and fall out.
Skin/Hair Type Suitability
ong Term Hair Reduction – Hair Growth Cycle
Two factors play an important role in optimal long-term hair reduction:
• air growth cycle (Anagen, Catagen and Telogen). Anagen is the growth phase while Catagen and Telogen
are the resting phases. Permanent hair reduction can only occur during the Anagen phase.
• Skin type (according to Fitzpatrick scale). Darker skin contains more melanin, which competes with the
targeted hair for energy light absorption. When more light energy is absorbed in the skin there is more risk
of adverse effects and the epidermis may get damaged.
See inside back cover for skin type and hair colour table
Treatment is very effective in skin types 1 to 4. For skin type 5, more treatment will be required to achieve the
desired results. This is because greater part of the energy delivered by the unit, will be absorbed by the skin. It
is not recommended to treat skin type 6 because most of the energy would be absorbed by the skin causing
irritation and other adverse effects. Different parts of the body will respond differently to treatment, areas
with high density of hair follicles will generally require more treatments before hair reduction is noticeable e.g
Underarms will need more treatments than the legs
As a guide:
- Darker hair will respond better to treatment
- Thick hair will see results more quickly
- The greater the contrast between the skin and hair colour (e.g pale skin, dark hair) the faster and better
the response.
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 8
Recommended treatment protocol:
With repeated treatments over time you can expect to see cumulative hair reduction. It is important to
maintain the treatment schedule over the first 8-12 weeks followed by subsequent treatments as and when
required. Previously dormant hair follicles may become active at any time (it is only possible to treat follicles in
the growth phase). It is important to remember that results will vary with each individual and are not
immediate, evaluate results after the 8-12 week treatment program is complete.
Duo gives you the power to fight unwanted hair growth delivering long term results for perfectly smooth
skin.
For body treatment
Treatment protocol depends on Skin-type/Level selection. aving determined the appropriate level
according to the above chart and/or spot test, follow these recommendations.
Freeglide AFT - evels 1, 2 and 3
Due to the lower energy levels treatments can be repeated up to twice a week on an on-going basis as
required. Freeglide AFT mode provides a comfortable treatment even in the most sensitive areas and with
darker skin tones. More regular treatment is required to achieve similar results to Single Shot mode
Single Shot IP - evels 4 and 5
Using higher levels of energy the sessions should be separated by a minimum of 2 weeks. Initially, it is
recommended to treat every two weeks for 6 treatments and then complete top-up treatments as required
with at least a two week interval. Single Shot IPL is a higher energy treatment, but can cause some discomfort
as it exposes the skin to higher temperatures during treatment. It is not recommended to use single shot
mode if you have skin type 5 – see skin tone chart on inside back cover.
The effect of the treatments will depend on skin type and hair colour, the results are cumulative. As you
continue to perform more treatments you should notice less hair regrowth.
• Due to hormonal or other physiological changes dormant hair follicles may become active and new hairs
can appear – maintenance hair reduction sessions may be required from time to time.
What to expect when using Duo
• A flash of light – it will not harm the eyes when the applicator is applied with full contact to the skin, on the
recommended treatment areas, but avoid looking directly at the flash.
• Fan noise – Lower than that of a hair dryer.
• A pop noise with each pulse – whenever a pulse is activated.
• A sensation of warmth – from the light energy after each pulse.
• A mild stinging sensation - similar to that of being snapped with a rubber band.
For facial treatment (with facial attachments *available separately)
Treatment protocol depends on Skin-type/Level selection. aving determined the appropriate level
according to the above chart and/or spot test, adhere to following recommendations. Follow the same
procedure as detailed above; take care not to treat moles or the lips. Use white eyeliner or a piece of paper to
protect delicate areas as necessary.
9
GB
Hair Colour Skin Type
123456
Black Level 4/5 Level 4/5 3/4/5 3/4 1/2/3 Not suitable
Dark Brown Level 4/5 Level 4/5 3/4/5 3/4 1/2/3 Not suitable
Brown Level 4/5 Level 4/5 3/4/5 3/4 1/2/3 Not suitable
Dark Blonde Level 4/5 Level 4/5 3/4/5 3/4 1/2/3 Not suitable
White Blonde Not suitable Not suitable Not suitable Not suitable Not suitable Not suitable
Red Not suitable Not suitable Not suitable Not suitable Not suitable Not suitable
White Not suitable Not suitable Not suitable Not suitable Not suitable Not suitable
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 9
10
GB
INSTRUCTIONS FOR USE  SKIN REJUVENATION
N.B. It is recommended to carry out the Spot test (see above) at least 48hrs prior to treatment to
choose a safe treatment level for your skin.
1. Prior to use, make sure your skin is cleaned (free of any residue such as powders, creams, makeup,
antiperspirants or deodorants)
Warning! NEVER use flammable liquids such as alcohol or acetone to clean the skin before using Duo.
2. Make sure the skin rejuvenation cartridge is installed (see instructions on page 12 on how to change the
cartridge)
3. aving followed Duo set-up steps above, press the power button to turn on the device. The LED indicator
for level 1 will illuminate.
4. The device sets itself on the lowest energy level. Use the power button to increase the energy level to
reach the level determined in the spot test and according to your convenience. The energy level lights will
light up blue (AFT)/white (IPL) according to the selected level.
5. When using the skin rejuvenation cartridge on your face, be sure to wear the goggles provided.
6. Place the applicator treatment window on the required treatment area with full contact to the skin (the
applicator will not trigger a pulse if there is not full skin contact and the green ‘ready’ indicator light will
stop flashing but remain illuminated when the device is in good contact with the skin).
7. Dependent on the energy level selected the device can be used in two ways:
Freeglide method (AFT): This is the method used on energy levels 1-3. old the pulse button down
continuously and slowly move the device over the skin maintaining constant contact. In this mode it is
necessary to repeatedly pass the device over the same area up to 5 times to ensure maximum coverage
N.B. The higher the level the slower you will need to glide the device. This is because the more energy
released, the slower the pulse rate.
Single shot method (IP ): This is the recommended method to use for high energy levels 4-5. With the
treatment window in contact with the skin, press the trigger button and wait for the flash. Only shoot once
before moving the device to the next treatment area ensuring there are no gaps or overlaps in the treated
area. Wait for the status indicator LED to stop flashing (up to 3.5 seconds) before pressing the pulse button
again. During both treatment methods you will see a bright flash, hear a popping noise and may feel a
mild stinging and/or heat sensation. In this mode, it is only necessary to do two passes over the same
treatment area.
The product should not be used for more than 30 minutes at one time. After 30 minutes are up,
switch the device off and unplug from the wall.
NB: If the device is left on but not used for approximately 3 minutes it will automatically switch itself off. If
this has happened, press the power button to turn the device back on.
Post treatment care for facial treatment
Apply a calming lotion such as Aloe Vera.
Avoid using peeling and bleaching creams or products for at least 24 hours as this irritates the treated skin.
Avoid more than 15 minutes of direct sun exposure for at least 2 weeks post treatment. If recently treated skin
is exposed to sunlight in this time period, make sure to apply SPF 30 or higher sunscreen.
Skin Type Suitability
See below for skin type table
Treatment is very effective in skin types 1 to 3. For skin types 4 and 5, more treatment will be required to
achieve the desired results. This is because a greater part of the energy delivered by the unit, will be absorbed
by the skin. It is not recommended to treat skin type 6 because most of the energy would be absorbed by the
skin causing irritation and other adverse effects. Different parts of the body will respond differently to
treatment, areas with more skin (i.e. cheeks and eyes) will react faster than areas with less (forehead)
Skin Type
123456
Level 4/5 Level 4/5 3/4/5 3/4 1/2/3 Not suitable
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 10
11
GB
Recommended treatment protocol:
With repeated treatments, over time you can expect to see cumulative wrinkle reduction. It is important to
maintain the treatment schedule over the first 1-2 weeks followed by subsequent treatments as and when
required. It is important to remember that results will vary with each individual and are not immediate.
Treatment protocol depends on Skin-type/Level selection. aving determined the appropriate level
according to the above chart and/or spot test, follow these recommendations.
Skin Types 1-3
It is recommended to treat every day for the first week to see the most effective results. After the initial week,
continue with a daily treatment or top-up as and when needed.
When using energy levels 1-3, cover the same treatment areas by passing over the same area 5 times. Due to
the darker skin tone, energy levels 1-3 may be more comfortable on the skin, however it requires repeated
passes over the same area.
When using energy levels 4 and 5, cover the same area twice. Due to the higher energy level delivered, it is
not necessary to repeat more than twice.
Note: It is recommended to use the higher energy settings to see optimal results within the first week. If
lower energy is used, additional time may be required.
Skin Types 4 and 5
It is recommended to treat every 3 days for the first 3 weeks to see the most effective results. After the initial 3
weeks, continue with top-up treatments 2-3 times per week as and when needed.
When using energy levels 1-3, cover the same treatment areas by passing over the same area 5 times. Due to
the darker skin tone, energy levels 1-3 may be more comfortable on the skin, however it requires repeated
passes over the same area.
When using energy levels 4 and 5, cover the same area twice. Due to the higher energy level delivered, it is
not necessary to repeat more than twice.
What to expect when using Duo
•Aflash of light – it will not harm the eyes when the applicator is applied with full contact to the skin, on the
recommended treatment areas, but avoid looking directly at the flash.
• Fan noise – Lower than that of a hair dryer.
• A pop noise with each pulse – whenever a pulse is activated.
• A sensation of warmth – from the light energy after each pulse.
• A mild stinging sensation - similar to that of being snapped with a rubber band.
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 11
12
GB
POSSIBLE SIDE EFFECTS
When using Duo according to the instructions for use, side effects are rare. Please ensure you treat using an
appropriate energy level (see page 6) to decrease the likelihood of experiencing side effects. owever, every
cosmetic procedure including the usage of home use devices may cause some degree of side effects:
CLEANING AND MAINTENANCE
Make sure to turn off and unplug unit before cleaning.
It is recommended that the applicator head cover be cleaned after every session by using a dry, clean cloth to
gently wipe the device.
Keep the device dry, Never submerge the device or any of its parts in water.
The Replaceable Cartridge
The cartridge supplied with the product will last up to 50,000 pulses
When the cartridge has expired the status indicator and skin level indicator lights will
flash repeatedly. This indicates that the cartridge needs replacing. Replacement
cartridges are available from www.homedics.co.uk.
The Facial Cartridge (sold separately)
The cartridge will last up to 10,000 pulses. When the cartridge has expired the status
indicator and skin level indicator lights will flash repeatedly. This indicates that the
cartridge needs replacing. Replacement cartridges are available from
www.homedics.co.uk.
To to change or replace the cartridge:
1. Turn off the device and then unplug from the Power outlet.
2. Firmly grasp the used cartridge on both sides and pull out in an even and smooth
motion. Do not pull out with force. Discard the expired cartridge (see page 3).
3. Remove all packaging from the new cartridge and insert it into place.
Warning! Do not pull out the used cartridge before turning off and then unplugging
the device!
Minor Side- Effects
• Irritation/redness – if it does not fade within 24 hours seek medical advice
• Sun Sensitivity – Avoid more than 15 minutes direct sun exposure for at
least 2 weeks post treatment.
Rare Side-Effects
Seek medical advice should
any of these occurs
• Burns
• Scarring
• Pigment Changes
• Excessive Redness
• Swelling
Extremely Rare Side-Effects
Seek medical advice should
any of these occurs
• Infection
• Bruising
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 12
13
GB
TROUBLES OOTING
Note: If you experience any problems with the device, please refer to below information to try to resolve it.
If the device does not trigger a pulse
• Make sure that the power cord is plugged properly into the handset and the electrical outlet.
• Verify there is full contact with the skin. The pulse button will activate a flash pulse only when the
applicator is in full contact with the skin.
• In case the cartridge is not properly connected the indicator and level lights will flash simultaneously.
• If the indicator and level lights are flashing simultaneously and the cartridge is properly connected to the
unit, this indicates that the cartridge needs replacing.
FAQ’s
Does AFT/IP actually work?
Yes, these technologies are proven to achieve long-term hair reduction results. The use of light energy has
been well documented for over 17 years in professional journals and by well-respected institutions.
Which body areas can the device be used on?
The device is designed to remove hair everywhere below the cheek line with the most commonly treated
areas being the legs, underarms, arms and bikini line. Men should not use the device for facial treatment.
Is the device safe for use?
The device has been tested and approved by dermatologists and physicians to meet the European safety
standards for a home use device. This electronic device must be used according to the instructions for use
and user precautions.
What effect does the device have on different coloured hair?
Duo works best on dark hair or hair that contains more melanin. Brown and light brown hair will respond but
typically will require more treatment sessions. Red hair may show some response. White, grey or blond hair
show limited response. Nevertheless, some users have noted hair reduction after multiple treatment sessions.
Does it hurt to use the device?
Some users may experience discomfort (when dealing with thicker and darker hair) but this discomfort
diminishes once the session is completed. When correctly used most users feel a slight mild
stinging or/and heat sensation at the time of the pulse light similar to that of snapping an elastic band.
When are results from the device achieved?
Results are not immediate, typically after two weeks many of the hairs in the treated area will simply fall out.
As the hair grows in three different stages and only hairs in the active growth phase will be affected, multiple
sessions are required to achieve the desired result. Results are cumulative; as you continue your treatment
programme you will notice less and less hair regrowth.
Will my hair grow back after a treatment?
It is not possible to successfully treat all hair follicles successfully in a single treatment. The results are
cumulative and you will notice an improvement in the results the more treatments you complete.
Successfully disabling hair follicles is dependent on the growth phase at the time of treatment, so a number
of treatments over a period of time yield the most effective cumulative results. Follow the initial course of
treatments until the end and top-up as often as necessary.
How long after sun exposure can the device be used?
It is recommended to wait four weeks after unprotected sun exposure. Tanned skin contains more Melanin
that can increase the risk for adverse effects.
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 13
Should I pull the hair out as part of or after the treatment sessions?
No. within 3 weeks the hair will naturally and gradually fall out. Not all the hairs are affected by one treatment
because of the hair growth cycle and multiple treatments are required to reach the desired result.
Is long term use of the device dangerous for my skin?
The use of light and laser energy has been well documented for over 17 years. No side-effects or damage
from long term use has been reported during that time.
Can the device be used to remove facial hair such as chin hair?
Yes, the device may be used below the cheek line, on the upper lip, cheek, jaw, chin and neck. Do not use the
device near your eyes! Men should not use the device for facial treatment.
Can men use the device?
Yes, IPL/AFT is suitable for men; however men should not use the device for facial treatment. Male body hair,
especially on the chest will generally require more hair reduction sessions.
When are results from the device achieved (skin rejuvenation)?
After the initial couple of treatments users will start to see an improvement in the appearance of wrinkles.
Results are cumulative, as you continue your treatment you will see better results
How do I get more cartridges?
To order more cartridges visit your local stockist or www.homedics.co.uk.
SPECIFICATIONS
Hair removal Facial cartridge
Emitted Light Spectrum: 480nm~1200nm Max. 560nm~1100nm Max.
Emitted Energy Flux: 5 [Joules/cm²] 3.3 [Joules/cm²]
Selectable Energy Levels: 5 levels 5 levels
Treatment Area (regular window): 3 [cm²] 2 [cm²]
Max pulses in lamp: up to 50,000 up to 30,000
Power Supply: 100-240 VAC, 50-60 z 100-240 VAC, 50-60 z
Technology: ome use IPL and AFT ome use IPL and AF
Storage and Transport Conditions
Temperature
Humidity
Pressure
-15 degree ~ 55 degree
10~90%rH
50~105KPa
Operating Conditions
Temperature
Humidity
Pressure
10 degree~35 degree
35~75%rH
70~105KPa
14
GB
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:31 Page 14
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:33 Page 15
IB-IPLHH160GB-0315-01
IB-IPLHH160GB-0315-01_Layout 1 28/04/2015 09:33 Page 16

This manual suits for next models

1

Other HoMedics Personal Care Product manuals

HoMedics FB-55PB-EU User manual

HoMedics

HoMedics FB-55PB-EU User manual

HoMedics spaREFLECTIVES M-8090 Instruction Manual

HoMedics

HoMedics spaREFLECTIVES M-8090 Instruction Manual

HoMedics BDY-300 Instruction Manual

HoMedics

HoMedics BDY-300 Instruction Manual

HoMedics WMH-200H User manual

HoMedics

HoMedics WMH-200H User manual

HoMedics MIR-150 Instruction Manual

HoMedics

HoMedics MIR-150 Instruction Manual

HoMedics FAC-2B-CA Instruction Manual

HoMedics

HoMedics FAC-2B-CA Instruction Manual

HoMedics SOUND SPASS-2000-2GB User manual

HoMedics

HoMedics SOUND SPASS-2000-2GB User manual

HoMedics illumi User manual

HoMedics

HoMedics illumi User manual

HoMedics PowerDent HD-IRR User manual

HoMedics

HoMedics PowerDent HD-IRR User manual

HoMedics FacialSauna FAC-1 User manual

HoMedics

HoMedics FacialSauna FAC-1 User manual

HoMedics FAC-500-EU User manual

HoMedics

HoMedics FAC-500-EU User manual

HoMedics EYE REVIVE LUXE User manual

HoMedics

HoMedics EYE REVIVE LUXE User manual

HoMedics MIR-8150-EU User manual

HoMedics

HoMedics MIR-8150-EU User manual

HoMedics ELM-FS100-GB User manual

HoMedics

HoMedics ELM-FS100-GB User manual

HoMedics LUXURY FM-90-EU User manual

HoMedics

HoMedics LUXURY FM-90-EU User manual

HoMedics MIR-100-EU User manual

HoMedics

HoMedics MIR-100-EU User manual

HoMedics PED-600-EU User manual

HoMedics

HoMedics PED-600-EU User manual

HoMedics Foot Salon Pro FB-600 User manual

HoMedics

HoMedics Foot Salon Pro FB-600 User manual

HoMedics MDA-100RGA-EU User manual

HoMedics

HoMedics MDA-100RGA-EU User manual

HoMedics FB-300-CA User manual

HoMedics

HoMedics FB-300-CA User manual

HoMedics FAC-300 Instruction Manual

HoMedics

HoMedics FAC-300 Instruction Manual

HoMedics ELM-FS100-GB User manual

HoMedics

HoMedics ELM-FS100-GB User manual

HoMedics Refresh User manual

HoMedics

HoMedics Refresh User manual

HoMedics PED-1200 Instruction Manual

HoMedics

HoMedics PED-1200 Instruction Manual

Popular Personal Care Product manuals by other brands

LIFEPLUS The Dona Care Starter Guide

LIFEPLUS

LIFEPLUS The Dona Care Starter Guide

Rotel FIGARO 830CH1 Instructions for use

Rotel

Rotel FIGARO 830CH1 Instructions for use

mychway MS-54D1S user manual

mychway

mychway MS-54D1S user manual

Gio Pelle GP-PL-70 Installation, operation & maintenance manual

Gio Pelle

Gio Pelle GP-PL-70 Installation, operation & maintenance manual

TytoCare Point of Care user guide

TytoCare

TytoCare Point of Care user guide

Orliman OSL1308 Use and maintenance instructions

Orliman

Orliman OSL1308 Use and maintenance instructions

RUSTA 90701136 manual

RUSTA

RUSTA 90701136 manual

DermaSweep MicroResurfacing Mini manual

DermaSweep

DermaSweep MicroResurfacing Mini manual

Medisana LSB 45200 manual

Medisana

Medisana LSB 45200 manual

Imetec PB10 Instructions for use

Imetec

Imetec PB10 Instructions for use

Philips DreamStation 2 quick start guide

Philips

Philips DreamStation 2 quick start guide

VOWNER JY-1222 user manual

VOWNER

VOWNER JY-1222 user manual

Anjou AJ-PCA023 user guide

Anjou

Anjou AJ-PCA023 user guide

Champion M2 Series Operation, Cleaning, and Maintenance Guide

Champion

Champion M2 Series Operation, Cleaning, and Maintenance Guide

Orliman BE-160 Use and maintenance instructions

Orliman

Orliman BE-160 Use and maintenance instructions

DURAVIT LM 7833 Mounting instructions

DURAVIT

DURAVIT LM 7833 Mounting instructions

Deta-Elis Deta-Cosmo user manual

Deta-Elis

Deta-Elis Deta-Cosmo user manual

Pebble Grey 500.20.10 quick start guide

Pebble Grey

Pebble Grey 500.20.10 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.