Hon Turing HT-S-3000 User manual

2.
Connect the cables to the power input
terminals on the rear panel of power inverter.
The red terminal is positive (+) and black
terminal is negative (-).
Connect the cables into the terminals and
tighten the wing nut to clamp the wires
securely.
3.
Connect the cable from the negative terminal
of the inverter to the negative terminal of
the power source. Make a secure connection.
Loosely tightened connectors result in
excessive drop and may cause overheated
wires and melted insulation.
4.
Before proceed further, carefully check that
cable you have just connected connects
from the negative terminal of inverter to the
negative output terminal of the power source.
Reverse polarity connection will blow
a fuse in inverter and may permanently
damage the inverter. Damage caused
by reverse polarity connection is not
covered by our warranty.
5.
Connect the cable from the positive terminal
of inverter to the positive terminal of the
power source. Make secure connection.
You may observe a spark when you make
this connection since current may flow to
charge capacitors in the power inverter.
Do not make this connection in the presence
of flammable fumes, explosions or fire
may result.
6. Set the power switch to the ON position.
Check the meters and indicators on the
front panel of the inverter.
DC to AC Power inverter manual
If does not, check your power source and
the connections to inverter. The other
indicators should be off.
7.
Set power inverter switch to the OFF
position, the indicator lights may blink.
Plug the test load into the AC receptacle
on the front panel of the inverter. Please
keep switch in off position.
8.
Set power inverter switch to the ON
Firstly, thank you for purchase our product.Please read this manual carefully before installing
or using this product.
This model is used in a wide range of
application including remote homes, RVs,
sailboats and powerboats.
It will operate most televisions and VCR,
personal computers, small appliances
and tools such as drills, sanders, grinders,
mixers and blenders.To get the most out
of the power inverter, it must be installed
and used properly.
Introduction
If you would like to quick hook-up the power
inverter and check its performance before
going ahead with your installation, please
follow these guidelines:
1.
Unpack and inspect the power inverter,
check to see that the power switch is in the
OFF position.
Quick hook – up and testing
◎
Pure sine wave output (<2% THD).
◎
Input & Output fully isolation design.
◎
High surge in motor start capacity.
◎
Thermal control fan.
◎
Frequency 50/60HZ switchable.
◎
Auto restart.
◎
Power saving function ( <10W load )
SPECIFICATIONS
Please read the instructions in this manual before
installing and using
this model.
Rear view
With Bypass FunctionNo Bypass Function
Connect to battery or other
power source.
"+" is positive (Red),
"-" is negative(Black),
Reverse polarity connection
will blow internal
fuse and
may damage inverter
permanently.
Battery terminals
DC Input
DC INPUT
(Red)
(Black)
Do not obstruct, allow at
least one inch for airflow.
Ventilation window
Warning:
Don`t reverse input and
output wiring.or internal
damage.
AC OUTPUT AC IUTPUT
BREAKER
press to restart if
open circuit.)
ON/OFF
Fult
AC Waring
AC Output
AC Output
Remote
control-LED
Remote
control-LED
DIP Switch
Function DIP Switch
Function
Breaker
HT-S-3000
HT-S-3000-12 HT-S-3000-24 HT-S-3000-48
Model No.
AC Voltage
Continuous Power
Surge Power
Waveform
Frequency
AC Regulation
Receptacles
DC Current
DC noload current under normal mode.
DC Voltage
Voltage Range
Efficiency (Typ.)
DC Connector
Fuse
DC noload current under power saving mode.
Battery low alarm
Battery low shut down
Over voltage
Over Temperature
Short Circuit Protection
Battery polarity
Over Load
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP.COEFFICIENT
EMI Conduction & Radiation
EMS Immunity
LVD
UL
Dimension (L*W*H)
NET. Weight
Gross Weight (With Cable)
100VAC/120VAC/230VAC
3000W
6000W
Pure Sine Wave
PURE SINE WAVE
50/60HZ±3%
±5%
YES, 1pc
Cable*1pc
12V/24V/48V
10-16VDC(12V) / 20-32VDC(24V) / 40-61V(48V)
15pcs
1.0A(12V) / 0.5A(24V) / 0.25A(48V)
0.12A(12V) / 0.06A(24V) / 0.03A(48V)
300A(12V) / 150A(24V) / 75A(48V)
10.5±0.5V(12V) / 21±1V(24V) / 42±2v(48v)
10±0.5V(12V) / 20±1V(24V) / 40±2V(48V)
16±0.5V(12V) / 32±1V(24V) / 61±2V(48V)
55°C±5°C
Shut-off
Fuse Burn out
re-start 1 time, shut down if failed
-15°C~+45°C
20%~90% RH non-condensing
-30°C~+70°C/-22°F~+158°F, 10~95% RH
±0.05%°C(0~55°C)
Compliance to EN55022 class B, 72/245/CEE, 95/54/CE
Compliance to EN61000-4-2, 3
Compliance to EN60950
UL458
570*274*105mm
9.8kgs
10.8kgs
OUTPUT
INTPUT
PROTEC-
TION
ENVIRON-
MENT
SAFETY
OTHERS
EXTRA
FUNTION
Connector
INPUT
Input AC terminal
Byass function
Output AC Terminal
Receptacles
DC noload current under normal mode.
DC noload current under power saving mode.
Low AC input volt transfer to inverter mode.
Low AC input volt recovery to AC mode.
High AC input volt transfer to inverter mode.
High AC input volt recovery to AC mode.
Yes
No
Yes, hard wiring.
Yes, hard wiring.
1.0A(12V) / 0.5A(24V) / 0.25A(48V)
0.4A(12V) / 0.2A(24V) / 0.1A(48V)
90Vac+/-5% or 180Vac+/-5%
95Vac+/-5% or 190Vac+/-5%
132Vac+/-5% or 265Vac+/-5%
125Vac+/-5% or 250Vac+/-5%
Optional

3.Input voltage
The power inverter will operate from input
voltage range 10V-16V (12V spec.) or 20V-32V
(2
4V spec.) or 40V-61V (48V spec.).
3. Grounding
The power inverter has a lug on the rear
panel chassis ground. This is to connect
the chassis of the power inverter to the
ground. The ground terminals in the AC
outlets on the front panel of the inverter
are also connected to the ground lug.The
chassis ground lug must be connected
to a grounding point, which will vary
depending on where the power inverter is
installed. In a vehicle, connect the chassis
Troubleshooting
Television interference :
Operation of the power inverter can interfere
with television reception on some channels.
If this situation occurs, the following steps
may help to alleviate the problem.
-Make sure that the chassis ground lug
on the back of the power inverter is solidly
connected to the ground system of your
vehicle, boat or home.
-Do not operate high power loads with
the power inverter while watching
television.
-Make sure that the antenna feeding
your television provides an adequate
(snow free) signal and that you are using
good quality cable between the antenna
and the television.
-Move the television as far away from
the power inverter as possible.
-Keep the cables between the battery
and the power inverter as short as possible
and twist them together with about 2 to 3
twists per foot. This minimizes radiated
interference from the cables.
Maintenance
You should clean the exterior of the unit
periodically with a dry cloth to prevent
accumulation of dust and dirt.
At the same time, tighten the screws on
the DC input terminals.
have to deliver the starting currents for all
the loads at once.
Controls and indicators
The ON/OFF switch turns the control
circuit in the power inverter on and off. It
does not disconnect power from the power
inverter.
Operating limits
1.Overload / Auto re-start
The inverter would operate most AC loads
within its power rating. If the load is over
the specification, HT-S-3000 will auto re-
start first, if not success, the inverter
will shut down automatically.
2.Overtemp
The buzz will be noisy if the temperature is
too high, then the inverter will be shut down
automatically. Please re-set it after the
inverter got cooling.
Approx. Amps
Req'd Wire Guage
Max Watts Out
15A #16150W
30A #12300W
60A600W
100A #4
#4
#4
6 X #4
2 X #4
2 X #4
1000W
120A1200W
150A
#6 or 2×#10
1500W
1800W
2500W
3000W
180A
250A
300A
1. Where to install
The power inverter should be installed in a
location that meets the following requirements:
a.
Dry - Do not allow water to drip or splash
on the inverter.
b.
Cool - Ambient air temperature should
be between -15°C and +45°C, the cooler
the
better.
c. V
entilated - Allow at least one inch of
clearance around the inverter for airflow.
Ensure the ventilation openings on the
rear and bottom of the unit are not
obstructed.
d.
Safe - Do not install the inverter in the
same compartment as batteries or in any
compartment capable of storing flammable
liquids such as gasoline.
2. Cables
DC to AC inverters require high amperage/low
voltage DC power to low amperage/high
voltage AC power. To operate properly
connect inverter DC input terminals direct
to battery with heaviest wire available see
chart below:
Installation
position, the inverter should supply
power to the load.
fault LED Indicator
Remote control-LCD
ON/OFF switch
Fault
ON / OFF
Waveform
Power saving
function
Battery volt
Load watts
Battery capacity
High battery
volt protection. Low battery
volt protection. Overload
Over temperature
ground to the chassis of the vehicle.
In a boat, connect to the boat’s grounding
systems. In a fixed location, connect the
chassis ground lug to earth.
Warning!
Do not operate the power inverter
without connecting it to ground.
Electrical shock hazard may result.
Operation
To operate the power inverter, turn it on
using the ON/OFF switch on the front
panel. The power inverter is now ready to
deliver AC power to your loads. If you are
operating several loads from the power
inverter, turn them on separately after the
inverter has been turned on. This will
ensure that the power inverter does not
If the voltage drops too low(※1) or raise too
high(※2), the inverter will shut down automatically.
Before shut down, buzz noise will warn you.
※1:
<10.0V (12V spec.) or <20V (24V spec.)
or <40V (48V spec.)
※2:
>16V (12V spec.) or >32V (24V spec)
or >61V (48V spec.)

Troubleshooting guide
Problem possible cause solution
High input
voltage alarm,
protection
(shutdown)
Battery voltage too high Reduce input volts
Low input voltage
alarm, protection
(shutdown)
Battery voltage too low
Change battery or
recharge
battery
Overload protection
(shutdown)
AC load watts is too high
Reduce load on the
inverter./ Solve short
circuit
situation.
Overtemp
alarm, protection
(shutdown)
Inverter temperature
is too high
Allow the inverter to cool.
Roduce the load if
continuous operation is
reguired.
0 OFF
DIP Switch Function
ON ON
ON OFF
OFF ON
OFF OFF
S2 S3
Power sav. count down time 30sec.
Power sav. count down time 10sec.
Bypass OFF Power sav. OFF
Bypass ON Power sav. OFF
60HZ
50HZ
S1 S2 S3
PWR. SAV.
&
Bypass
Freq.
1 2 3
ON
Table of contents
Other Hon Turing Inverter manuals
Popular Inverter manuals by other brands

YASKAWA
YASKAWA VS MINI J7 series instruction manual

IO-Power Technology
IO-Power Technology IOP-USSS-12V3556-OA Series user manual

SOLINTEG
SOLINTEG INTEG M MHS Series Quick installation guide

K2
K2 CrossRail 44-X Assembly instructions

Omron
Omron 3G3MX2-AB001-E instruction manual

Goodwe
Goodwe MT series Quick installation guide