manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Security Sensor
  8. •
  9. Honeywell DT7235T User manual

Honeywell DT7235T User manual

Other manuals for DT7235T

1

This manual suits for next models

2

Other Honeywell Security Sensor manuals

Honeywell OMV-VX Series User manual

Honeywell

Honeywell OMV-VX Series User manual

Honeywell C554A User manual

Honeywell

Honeywell C554A User manual

Honeywell FlexGuard FG-1625F User manual

Honeywell

Honeywell FlexGuard FG-1625F User manual

Honeywell FS24X User manual

Honeywell

Honeywell FS24X User manual

Honeywell IS312B User manual

Honeywell

Honeywell IS312B User manual

Honeywell Miller AirCore Oil & Gas Harness User manual

Honeywell

Honeywell Miller AirCore Oil & Gas Harness User manual

Honeywell ESSER 784763 User manual

Honeywell

Honeywell ESSER 784763 User manual

Honeywell MDA Scientific MIDAS User manual

Honeywell

Honeywell MDA Scientific MIDAS User manual

Honeywell Ex-Or Digital Gold Series Installation and operation manual

Honeywell

Honeywell Ex-Or Digital Gold Series Installation and operation manual

Honeywell AreaRAE Plus User manual

Honeywell

Honeywell AreaRAE Plus User manual

Honeywell EC-P2 Manual

Honeywell

Honeywell EC-P2 Manual

Honeywell Purple Peeper C7012A User manual

Honeywell

Honeywell Purple Peeper C7012A User manual

Honeywell FS20X Series User manual

Honeywell

Honeywell FS20X Series User manual

Honeywell C7076F User manual

Honeywell

Honeywell C7076F User manual

Honeywell Miller 8172 Operator's manual

Honeywell

Honeywell Miller 8172 Operator's manual

Honeywell FlexGuard 5853 User manual

Honeywell

Honeywell FlexGuard 5853 User manual

Honeywell 5800PIR User manual

Honeywell

Honeywell 5800PIR User manual

Honeywell C7961E Operation manual

Honeywell

Honeywell C7961E Operation manual

Honeywell NOTIFIER IRX-751CTEM User manual

Honeywell

Honeywell NOTIFIER IRX-751CTEM User manual

Honeywell ADEMCO 5821 User manual

Honeywell

Honeywell ADEMCO 5821 User manual

Honeywell MILLER 1032363 User manual

Honeywell

Honeywell MILLER 1032363 User manual

Honeywell HAQSPA-R User manual

Honeywell

Honeywell HAQSPA-R User manual

Honeywell HAQSPA-R User manual

Honeywell

Honeywell HAQSPA-R User manual

Honeywell Searchline Excel Cross-Duct Release Note

Honeywell

Honeywell Searchline Excel Cross-Duct Release Note

Popular Security Sensor manuals by other brands

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

urmet domus 1083 manual

urmet domus

urmet domus 1083 manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

DMP Electronics 1122INT installation guide

DMP Electronics

DMP Electronics 1122INT installation guide

Rielta Ladoga MK-RK installation guide

Rielta

Rielta Ladoga MK-RK installation guide

Mirion Technologies ACCURAD PRD user manual

Mirion Technologies

Mirion Technologies ACCURAD PRD user manual

Bosch DS835 installation instructions

Bosch

Bosch DS835 installation instructions

Lamptime ST05C instructions

Lamptime

Lamptime ST05C instructions

Ubiquiti MFI-MSC quick start guide

Ubiquiti

Ubiquiti MFI-MSC quick start guide

Subsite 910R Support

Subsite

Subsite 910R Support

Satel OPAL Pro manual

Satel

Satel OPAL Pro manual

Aleph XC-1XTEU manual

Aleph

Aleph XC-1XTEU manual

Pima LARIS QUAD installation instructions

Pima

Pima LARIS QUAD installation instructions

Solinst 301 user guide

Solinst

Solinst 301 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DT-7235/DT-7235T DUAL TEC®Motion Sensor Installation Instructions
TT
Step 1
Separate the sensor housings and remove
Printed Circuit Board (PCB).
Use a small screwdriver to unfasten the hous-
ing latch and separate the sensor housings.
Push outward on the PCB latch to lift the PCB
out of the housing.
Step 3
Wire the sensor.
Observing the proper polarity, wire the unit as
shown in the illustration below, use 1.02 to 0.64 mm
(18 to 22 AWG) wire.
Step 2
Mount the sensor.
Break out the mounting/wiring knockouts and
mount the sensor in an appropriate location.
An ideal location meets the following objectives:
• Allows a clear line-of-sight to all areas to
protect.
• Does not directly face windows.
• Avoids close proximity to moving machinery,
fluorescent lights, and heating/cooling
sources.
•See Special Instructions for installations
containing pets.
NOTE: maximum range is obtained at a
mounting height of 2.3 m (7’6”).
Knockout
Housing
latch
PCB latch
FRONT HOUSING
REAR HOUSING AND PCB
Terminal Block (TB1)
PCB
LED
(DS1)
LED Enable
(Cut or remove
LED enable jumper
J1* to disable LED)
Alarm
500 mA
30 VDC
Power
25 mA
7.5-16 VDC
(UL: 8.9-14.5 VDC)
Step 4
Walk-test the sensor.
After returning the PCB to the rear hous-
ing, reassemble the sensor housing. Ap-
ply power to the sensor and begin walk-
test when the red LED is off.
Walk across the detection area at the
ranges to be covered. The red LED should
indicate an alarm condition after 2 to 4 nor-
mal steps. When there is no motion in the
detection area the LED should be off.
DT-7235
TB1
TB2
DT-7235T
Alarm
500 mA
30 VDC
Power
25 mA
7.5-16 VDC
(UL: 8.9-14.5 VDC)
TB1
DT-7235T Tamper
50 mA
24 VDC
TB2
Remove look-down
mask for non-pet
applications.
* J1 may be located in either location
indicated in the above illustration.
DT-7235/DT-7235T DUAL TEC®Motion Sensor Installation Instructions
MICROWAVE SUPERVISION
If the microwave technology stops sending or receiving signals,
the sensor locks into an alarm condition. The LED at the sensor,
however, does not light.
If the microwave regains its signal, the sensor (and LED) returns
to normal operation.
NOTE: The DT-7235/7235T sensors should be tested at least
once each year to ensure proper operation.
DETECTION PATTERNS
DT-7235 / DT-7235T
Pet Immune Lens
11 m (35’)
PRODUCT SPECIFICATIONS
Range:
35’ x 40’ (11 m x 12 m)
UL Limits: 35’ x 35’ (11 m x 11 m)
Alarm relay:
Energized Form A
500 mA, 30 VDC
Tamper (DT-7235T):
(NC) 50 mA, 24 VDC
Power requirements:
7.5 - 16 VDC (UL: 8.9-14.5VDC), 25 mA, 0.4W
AC Ripple: 3 V peak-to-peak at nominal 12 VDC
Frequencies:
24.125 GHz
PIR white light immunity:
6,500 Lux typical
RFI immunity:
30 V/m,10 MHz - 1000 MHz
Operating temperature:
+14o to +131o F (-10o to +55oC)
5 - 95% relative humidity (non-condensing)
(Indoor use environment)
PIR fields of view:
44 long range edges
36 intermediate edges
18 lower edges
4 down edges
Dimensions:
11.9 cm H x 7.1 cm W x 4.2 cm D
(4.685" H x 2.795" W x 1.654" D)
Sensitivity:
2 - 4 steps within field of view
Accessories:
Optional Lens Kits --
Pet Alley Lens Kit (P/N DT7000-PALK)
Long Range Lens Kit (P/N DT7000-LRLK)
High Security Lens Kit (P/N DT7000-HSLK)
Note: The function of these optional lenses with this
sensor has not been evaluated by Underwriters
Laboratories Inc.
Mounting Brackets --
SMB-10 Swivel Mount Bracket (P/N 0-000-110-01)
SMB-10C Swivel Mount Ceiling Bracket
(P/N 0-000-111-01)
SMB-10T Swivel Mount Bracket w/Tamper
(P/N 0-000-155-01)
Approvals / listings:
FCC
IC
cULus
DT-7235/DT-7235T DUAL TEC®Motion Sensor Supplemental Information
* Look-down fingers are enabled only when look-
down mask is removed, see Step 1.
SPECIAL INSTRUCTIONS FOR INSTALLATIONS CONTAINING PETS
To take full advantage of the pet immunity the following guidelines should
be followed:
• Mount the center of the detector 7’6” (2.3 m) high.
• Ensure that the look-down mask is in place (see Step 1).
• Mount where animals cannot come within six feet of the detector by
climbing on furniture, boxes or other objects.
• Do not aim the detector at stairways that can be climbed by animals.
Notes:
This sensor will provide immunity to false alarms for an individual animal
or a group of animals whose total weight is equal to or less than 45.36 kg
(100 lbs).
The pet immunity function of this sensor has not been evaluated by UL.
© 2004 Honeywell International Inc. - Honeywell, IntelliSense and DUAL TEC are registered trademarks of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved. Made in China
5-051-563-00 Rev J
FCC Notice: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by Honeywell may void the user’s
authority to operate this equipment.
IC Notice: This apparatus complies with Canadian Standards ICES-003 B and RSS-210.
Canada: Wiring methods shall be in accordance with CSA C22.1, Canadian Electrical Code, Part 1, Safety
Standard for Electrical Installations.