manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Security Sensor
  8. •
  9. Honeywell LightSpot LS1000R User manual

Honeywell LightSpot LS1000R User manual

Other Honeywell Security Sensor manuals

Honeywell Viewguard DUAL AM FAI Instruction manual

Honeywell

Honeywell Viewguard DUAL AM FAI Instruction manual

Honeywell 997 User manual

Honeywell

Honeywell 997 User manual

Honeywell 5800PIR User manual

Honeywell

Honeywell 5800PIR User manual

Honeywell Filtrex TC844A1007 User manual

Honeywell

Honeywell Filtrex TC844A1007 User manual

Honeywell FireLite BG-12LSP User manual

Honeywell

Honeywell FireLite BG-12LSP User manual

Honeywell BW Ultra User manual

Honeywell

Honeywell BW Ultra User manual

Honeywell FIRE-LITE ALARMS W-SD355 User manual

Honeywell

Honeywell FIRE-LITE ALARMS W-SD355 User manual

Honeywell 5897-35 User manual

Honeywell

Honeywell 5897-35 User manual

Honeywell Purple Peeper C7012A User manual

Honeywell

Honeywell Purple Peeper C7012A User manual

Honeywell Ex-Or MLS Installation and operation manual

Honeywell

Honeywell Ex-Or MLS Installation and operation manual

Honeywell C7962B Operation manual

Honeywell

Honeywell C7962B Operation manual

Honeywell Searchline Excel Cross-Duct Release Note

Honeywell

Honeywell Searchline Excel Cross-Duct Release Note

Honeywell IQ Force Installation manual

Honeywell

Honeywell IQ Force Installation manual

Honeywell HS3PIR1X User manual

Honeywell

Honeywell HS3PIR1X User manual

Honeywell SIXCO User manual

Honeywell

Honeywell SIXCO User manual

Honeywell Lyric YCHW4000W4004 Installation guide

Honeywell

Honeywell Lyric YCHW4000W4004 Installation guide

Honeywell Minipeeper C7027A Operation manual

Honeywell

Honeywell Minipeeper C7027A Operation manual

Honeywell Miller Revolution User manual

Honeywell

Honeywell Miller Revolution User manual

Honeywell SiX Series User manual

Honeywell

Honeywell SiX Series User manual

Honeywell MultiPro User manual

Honeywell

Honeywell MultiPro User manual

Honeywell Notifier FST-851 Series User manual

Honeywell

Honeywell Notifier FST-851 Series User manual

Honeywell SPM Flex User manual

Honeywell

Honeywell SPM Flex User manual

Honeywell C7061A1020 User manual

Honeywell

Honeywell C7061A1020 User manual

Honeywell Fire-Lite Alarms D365PL User manual

Honeywell

Honeywell Fire-Lite Alarms D365PL User manual

Popular Security Sensor manuals by other brands

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

urmet domus 1083 manual

urmet domus

urmet domus 1083 manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

DMP Electronics 1122INT installation guide

DMP Electronics

DMP Electronics 1122INT installation guide

Rielta Ladoga MK-RK installation guide

Rielta

Rielta Ladoga MK-RK installation guide

Mirion Technologies ACCURAD PRD user manual

Mirion Technologies

Mirion Technologies ACCURAD PRD user manual

Bosch DS835 installation instructions

Bosch

Bosch DS835 installation instructions

Lamptime ST05C instructions

Lamptime

Lamptime ST05C instructions

Ubiquiti MFI-MSC quick start guide

Ubiquiti

Ubiquiti MFI-MSC quick start guide

Subsite 910R Support

Subsite

Subsite 910R Support

Satel OPAL Pro manual

Satel

Satel OPAL Pro manual

Aleph XC-1XTEU manual

Aleph

Aleph XC-1XTEU manual

Pima LARIS QUAD installation instructions

Pima

Pima LARIS QUAD installation instructions

Solinst 301 user guide

Solinst

Solinst 301 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PACK CONTENTS
REQUIRED (Warning: Use only VDE Certified Tools)
MOUNTING/ INSTALLATION STEPS
Surface Mount
1
4
2
5
3
6
7
9
0FF
φ
5mm
50.8mm or 60mm
60mm
50.8mm
CAUTION:
OR
OR
‘CLICK’ ‘CLICK’
‘CLICK’
The device needs
20-50 seconds to
warm up.
1 x 2.5mm²
Cable entry
capability at
terminal block
2 x 1.0mm²
2 x 1.5mm²
Cut out
here
x1x1 x1 x1
M4 x 14mm
x2
(For Euro conduit box
installation)
M3 x 20mm
(For ceiling mout
installation)
M3 x 15mm
(For cable clamps
installation)
x2 x4 x2 x2
x1 x1 x1 x1 x1
Hole saw size:
x1
Ф75mm - 80mm
Ф5mm
4mm
No 2
Phillips
3mm
LS htSpot 360100 Lig0R ° Dual Mount PIR installation and operating instructions
Only suitably qualified personnel should install this equipment
!!
8
 Remark: R terminals are Volt-Free output
(when link is removed)
Option1 (live out) Option2 (volt-free)
LLive
N
Brown
RSwitched Live Brown
Neutral Blue
Earth Green / Yellow
LLive
N
Brown
RVolt-Free
RRelay contact Brown
Neutral Blue
Earth Green / Yellow
N
N L
µ
R R
L
N
N L R R
L
R
R
µ
•To prevent electrocution, do not work on any appliance live. Turn off mains before commencing work, lock-out tag-out must be followed.
•The current editions of the IEE Wiring Regulations (BS7671) and Buildings Regulations must be followed for installation.
•Ensure all terminal screws are fully tightened and product is securely fixed to its mounting box prior to turning on the mains supply.
Load
Note: Remove the external link
RRLN
WALK TESTING
1 3
MANUAL OVERRIDE OPERATION
Activate Manual Override Operation
SWITCHABLE LOAD
TECHNICAL SPECIFICATIONS
Detection Range:
Detection Angle:
Power Supply:
Maximum Switchable Load:
Time On Adjustment:
Dusk Level Adjustment:
Operating temperature:
Environment Protection:
Up to 6 metres diameter (3m Radius)
at mounting height of 2.5m
360°
230Vac 50Hz
Max load current 10A
Incandescent / Halogen Max 2000W
Fluorescent lamp (magnetic) Max 500W
Fluorescent lamp (electronic ballast) Max 400W
Low energy (CFL) Max 120W
LED lamp Max W400
Fan Max 75W
5 seconds - 15 minutes
Day & night or night only operation
0 to 40 degrees
For ceiling mount - IP44
For flush mount - IP44 (at sensor portion only)
- IP20 (ceiling board onwards)
Max 400W
Max 500W
Max 2000W @230V Max 120W
Max 400W
Max 75W
2
MIN. SUN.
warm up
20-50 SEC
Around
10 second
Lamp turn on
when reach Lux
setting level.
ON
OFF
ON
2 times within 2 seconds
DUSK
DAWN
Hrs
2 SEC
5
SEC
1
Deactivate Manual Override Operation
Manual deactivation before dawn
2Auto deactivation when
dusk to dawn
ON
Lamp turn off when
dusk to dawn.
OFF
ON
1 time within 1 second
1 SEC
5
SEC
OR
Auto Mode
Auto Mode
ON
At the end of their useful life the
packaging and product should
be disposed of via a suitable
recycling centre.
Do not dispose of with normal
GUARANTEE
The company undertake to replace or repair, at its discretion should it become defective within a period
household waste. Do not burn.
of 1 year after delivery, solely as a result of faulty materials and/or workmanship. Understandably, if
the product has not been installed, maintained or used appropriately, or if an attempt has been made to
rectify, dismantle or alter the product in any way, the guarantee will be invalidated.This guarantee states
the company's entire liability. It does not extend to cover consequential loss or damage or installation
cost arising from the defective product.This guarantee does not restrict or infringe the normal statuary
rights of the customer.
COMPLIANCE WITH E.U. DIRECTIVES
Apart from meeting the appropriate British standards, products are
manufactured in accordance with BS EN ISO 9002 and comply
with the LV (72/23/EEC) Directive.
C
M
Y
CM
MY
CY
CMY
K
EU contact for regulatory questions:
PEHA Elektro GmbH & Co.
KG Gartenstraße 49,
58511 Lüdenscheid Germany
Web: www.peha.de
Honeywell
St Marks Court, North Street
Horsham, West Sussex RH12 1BW
Tel: +44 (0)1942 719229
Web:www.buildings.honeywell.com/gb/e
n/brands/our-brands/ex-or
W6039 REVD 12/2/2023
MOUNTING/ INSTALLATION STEPS
Flush Mount
REMOVING
Surface Mount
REMOVING
Flush Mount
‘CLICK’
6 7 8
4 Opening hole
75mm~80mm diameter
Ceiling board
thickness
5mm-20mm
Power wire
9
‘CLICK’
Ceiling board The device need
20-50 seconds to
warm up.
5
1 2 3
0FF
230V
1 x 2.5mm²
Cable entry
capability at
terminal block
2 x 1.0mm²
2 x 1.5mm²
 Remark: R terminals are Volt-Free output
(when link is removed)
Option1 (live out) Option2 (volt-free)
LLive
N
Brown
RSwitched Live Brown
Neutral Blue
Earth Green / Yellow
LLive
N
Brown
RVolt-Free
RRelay contact Brown
Neutral Blue
Earth Green / Yellow
N
N L
µ
R R
L
N
N L R R
L
R
R
µ
Load
Note: Remove the external link
RRLN
TOP VIEW
MOTION SENSOR DETECTION
When mounting
at 2.5m height
Dia. 6 METRE
SIDE VIEW
2.5 M
1 M
3 METRE 3 METRE
10
20
30
40
°C
40
LENS MASK
Lens mask
sticker
Restrict
short
detection
Restrict
long
detection
Restrict
detection
directly
under
sensor
Adjustment
30 MIN
SEC
-Can be adjusted by flat head screwdriver.
5 SEC
ON-TIME LUX
TESTING & OPERATION
10
20
30
40
°C
40
10
20
30
40
°C
40
C
M
Y
CM
MY
CY
CMY
K
3 METRE
3 METRE 3 METRE
3 METRE
3 METRE
3 METRE
3 METRE
3 METRE