GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2009 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0584 Rev. C page 1 of 2
1415
Description
The System Sensor 1451 ionization type smoke detectors
are specifically designed to meet the performance require-
ments of fire detection and fire alarm systems. The 1451
ionization detector uses a state-of-the-art, dual unipolar
sensing chamber. The detector is designed to provide
open area detection and when installed in a two-wire base
is compatible with Gamewell-FCI fire alarm control panels.
The detectors operation and sensitivity can be tested in
place.
The 1451 detector is built of plug-in construction and plugs
into the same base as the 2451 Series photoelectronic
smoke detectors, making both models interchangeable.
The bases are available for two-wire, four-wire, and 120
VAC four wire operation.
Two visible LEDs on each detector flash approximately
every ten seconds indicating that power is being applied to
the detector. The LEDs light steadily when the detector is
in alarm. A remote LED annunciator is available as an
optional accessory.
The 1451 detector is Listed for use inside ducts up to a
velocity of 1,200 FPM.
Sensitivity testing is performed by placing a test magnet
against the cover. The LED on the detector should light
within 5 seconds.
Field metering of detector sensitivity may be performed
with the aid of a voltmeter and Test Kit, MOD 400R.
Specifications
Nominal Sensitivity: 1.5 %/ft
Operating Voltage: 8.5 - 35 VDC (24 VDC nominal)
Operating
Temperature: 32° to 120° F (0° to 49° C)
Operating Humidity: 10 % - 93 % relative humidity
Air Velocity: 1,200 FPM
Altitude: 10,000 ft.
Construction: Off-white flame retardant plastic
Diameter: 6.2 inches (15.7 cm)
Height: 3.2 inches (8.1 cm)
Weight: 0.5 lb (277 g)
Features
• Uses a unique dual unipolar sensor that provides
exceptional stability
• Offers an easy plug-in of the head to base
• Provides the following built-in features:
- Tamper-resistant
- Test switch
- Visual alarm indicators
• Displays a 360° view angle of alarm LEDs
• Compatible with the Gamewell-FCI fire alarm control
panels
• Performs field adjustable sensitivity and field metering
of detector sensitivity
• Furnishes insect-resistant screening (.020"/.508 mm
openings)
• Includes a removable insect screen and cover for field
cleaning
• Sealed against dirt, insects, and back pressure
System Sensor
Ionization Smoke Detector
1415
SIGNALING
FM MEA
ApprovedAPPROVED USLISTED
UL
CR
An ISO 9000-2000 Company
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
9020-0584 Rev. C page 2 of 2 www.gamewell-fci.com
Figure 1
Mounting
• On a 4 inch square box with or without plaster ring or
supplied adapter. Minimum depth 1.5 inches
• On a 3.5 or 4 inch octagonal box. Minimum depth 1.5
inches
• On a single gang box. Min. depth 1.5 inches
Installation
Place the detector into the detector base. Turn the detec-
tor clockwise until the detector locks into place.
To use the tamper-proof feature, break the smaller tab on
the scribed line in the tamper proof tab located on the
detector mounting bracket. Install the detector. To remove
the detector from the base when using the tamper-proof
feature, insert the blade of a small screwdriver into the
hole on the side of the base and push the plastic lever
away from the detector head. This will allow the detector to
be rotated counterclockwise for removal.
Note: The decorative ring must be removed in order to
remove the head when using the tamper-proof feature.
The tamper-proof feature may be defeated permanently by
breaking the plastic lever off the base
Note: The number of two-wire smoke detectors which can
be accommodated per zone varies with different control
panels. Consult the control panel instruction manual to
determine the capacity.
Refer to NFPA 72, Chapter 5-3, “Smoke Sensing Fire
Detectors” for spacing, location of detectors and other
guidelines.
Testing
Detectors may be tested in the following ways:
• Place a test magnet against the cover opposite the test
module socket. (See illustration). The detector should
go into alarm within 5 seconds.
• Field metering of detector sensitivity may be performed
with the aid of a voltmeter and Test Kit MOD 400R. For
the complete procedure, refer to the Installation and
Maintenance Instructions furnished with each detector.
Maintenance
Cleaning programs should be adapted to the individual
environment. We recommend at least, an annual cleaning
of the unit. The detector screen and cover assembly can
be removed, revealing the sensing chamber. A vacuum
cleaner can be used to remove dust from the screen,
cover and sensing chamber. For the complete procedure,
refer to the Installation and Maintenance Instructions fur-
nished with each detector.
WARNING: To prevent detector contamination during con-
struction, smoke detectors must be protected from dust
and contamination until the area is clean and dust free. see
NFPA 72 -5-3.7.1.3.
Ordering Information
Part Number Description
1451 Ionization Detector
Alarm Current ‡
B401B Base, two-wire
Supervisory
Current 00012 A
Alarm Current ‡
B402B Base, four-wire, 24 VDC operation
Supervisory .00012 A
Current .036 A
Contacts Form A, C*
B404B Base, four-wire, 120 VAC operation
Contacts Form A, C* & Supvervisory
RA-400 Remote alarm indicator
Alarm Current .007 A
PAM-1 End-of-line relay, 24 VDC
Alarm Current .015 A
Contacts Form B Test kit
*Resistive load
(Contact
Ratings): Form A - 2.0 A @ 30 VAC/DC
Form C - 2.0 A @ 30 VAC/DC, 1.0 A
@ 120 VAC
‡Note: Alarm current of detector is limited by control panel
initiating device circuit.
LOCK PRONG
REMOVABLE
SCREEN
REMOVABLE
COVER FOR
CLEANING
Views Show Position of Test Magnet
RECESSED
TEST SWITCH
TAMPER
SLOT
LED TEST MODULE
SOCKET PUSH RECESSED
SWITCH WITH A 0.1"
MAX. DIAMETER
TOOL

Other Honeywell Smoke Alarm manuals

Honeywell SS4-A HART User manual

Honeywell

Honeywell SS4-A HART User manual

Honeywell FireLite BEAM355 User manual

Honeywell

Honeywell FireLite BEAM355 User manual

Honeywell C8600A User manual

Honeywell

Honeywell C8600A User manual

Honeywell DFS8MS User manual

Honeywell

Honeywell DFS8MS User manual

Honeywell GENT Venturi-Air Duct Kit User manual

Honeywell

Honeywell GENT Venturi-Air Duct Kit User manual

Honeywell Fire-Lite Alarms SD365 User manual

Honeywell

Honeywell Fire-Lite Alarms SD365 User manual

Honeywell Fire-Lite Alarms D350RPL User manual

Honeywell

Honeywell Fire-Lite Alarms D350RPL User manual

Honeywell Gamewell 7100 Series Installation instructions

Honeywell

Honeywell Gamewell 7100 Series Installation instructions

Honeywell SK-Beam User manual

Honeywell

Honeywell SK-Beam User manual

Honeywell 5806W3 Assembly instructions

Honeywell

Honeywell 5806W3 Assembly instructions

Honeywell X Series User manual

Honeywell

Honeywell X Series User manual

Honeywell FCI 2151 User manual

Honeywell

Honeywell FCI 2151 User manual

Honeywell ADEMCO 5806 User manual

Honeywell

Honeywell ADEMCO 5806 User manual

Honeywell ALL-SPEC User manual

Honeywell

Honeywell ALL-SPEC User manual

Honeywell Notifier FSP-851 User manual

Honeywell

Honeywell Notifier FSP-851 User manual

Honeywell SiXSMOKE-CN User manual

Honeywell

Honeywell SiXSMOKE-CN User manual

Honeywell NOTIFIER FSP-951-SELFT User manual

Honeywell

Honeywell NOTIFIER FSP-951-SELFT User manual

Honeywell Fire-Lite Alarms OSI-RI-FL User manual

Honeywell

Honeywell Fire-Lite Alarms OSI-RI-FL User manual

Honeywell DFS8M User manual

Honeywell

Honeywell DFS8M User manual

Honeywell 5193SD User manual

Honeywell

Honeywell 5193SD User manual

Honeywell DFO800M User manual

Honeywell

Honeywell DFO800M User manual

Honeywell Silent Knight SD505 User manual

Honeywell

Honeywell Silent Knight SD505 User manual

Honeywell HI-SPEC User manual

Honeywell

Honeywell HI-SPEC User manual

Honeywell XLS-278 User manual

Honeywell

Honeywell XLS-278 User manual

Popular Smoke Alarm manuals by other brands

Mircom MIX-2251AP Installation and maintenance instructions

Mircom

Mircom MIX-2251AP Installation and maintenance instructions

Electronics Line EL-4703 installation instructions

Electronics Line

Electronics Line EL-4703 installation instructions

AMC 900 Series Programming guide

AMC

AMC 900 Series Programming guide

Lexing LX928-N Instruction

Lexing

Lexing LX928-N Instruction

Firephant SA800 user manual

Firephant

Firephant SA800 user manual

ring Smoke & CO Listener Z-Wave Technical manual

ring

ring Smoke & CO Listener Z-Wave Technical manual

Bosch ISW-EN1242 installation guide

Bosch

Bosch ISW-EN1242 installation guide

Edwards Signaling & Security Systems 517TB Series installation instructions

Edwards Signaling & Security Systems

Edwards Signaling & Security Systems 517TB Series installation instructions

Bosch Titanus Pro?Sens TP-1 A installation instructions

Bosch

Bosch Titanus Pro?Sens TP-1 A installation instructions

Voltex SAS115BW user manual

Voltex

Voltex SAS115BW user manual

Comelit 48BFC000 manual

Comelit

Comelit 48BFC000 manual

Kidde 900-0122 user manual

Kidde

Kidde 900-0122 user manual

HST HD103B Installation and maintenance instructions

HST

HST HD103B Installation and maintenance instructions

System Sensor 2112TL Installation and maintenance instructions

System Sensor

System Sensor 2112TL Installation and maintenance instructions

Kidde I9070 user manual

Kidde

Kidde I9070 user manual

Hark HK0528 Cooking guide

Hark

Hark HK0528 Cooking guide

Tanda TXC3100 Installation and operation manual

Tanda

Tanda TXC3100 Installation and operation manual

Emerald Planet EP-RFBASE Installation instruction

Emerald Planet

Emerald Planet EP-RFBASE Installation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.