Food Service > Water Filtration
BROCOF 0809
Installation
Please read instructions carefully prior to installation
1The lter system is installed between the water supply point and the ice
machine. The lter should be mounted on a rm vertical surface close to
the ice machine and for easy access.
2A plastic ball valve is supplied to be installed on the inlet of the lter
head so the water supply can be isolated for lter cartridge changeout. If
water pressure is above 900 kPa a 600 kPa pressure limiting valve should be
installed between the isolating valve and the lter system.
3Suitable food grade hose or pipework should be used to connect the lter
sytem. The lter system has a ½”bspm threaded inlet which is connected to
the inlet of the plastic ball valve. The plastic ball valve outlet is connected
to the inlet of the lter head. A ¾”bspm threaded outlet is supplied which
allows connection to hoses used.
4The mounting bracket is connected to the lter head with the 4 screws
provided. The mounting bracket and head should be installed in a suitable
location – ensure 100mm is allowed below bottom of the installed lter
cartridge to provide room for cartridge change out
5The lter cartridge is installed into the lter head by aligning the guide
arrows, pushing the cartridge upwards into the head, quarter turn right to
lock in the cartridge.
6First Flush – A rst ush is recommended to clear air from the new
system. Turn the inlet water supply valve on slowly whilst holding the
outlet hose into the bucket or drain. Air will be ushed through the lter in
a few litres. Once the water clears the inlet valve can be turned o and the
lter outlet hose can be connected to the inlet of the ice machine. The inlet
water supply can be slowly turned on. Check for and x any leaks.
The lter cartridge should be changed when any of the following occurs –
1The ltered water ow reduces substantially
2Taste/Odour occurs in the ltered water
3The maximum service period expires
Filter changeout instructions
1Turn o water supply at the ball valve prior to the lter system. Hold and
turn the lter cartridge a quarter turn to the left, pull down and remove the
cartridge. Be careful as residual water pressure may be present.
2Take the new replacement cartridge. Line up the guide arrows on the
cartridge and head and push the cartridge into the lter head and then do
a quarter turn to the right which locks in the lter cartridge.
3First Flush – A rst ush is recommended to clear air from the new
cartridge. Turn the inlet water supply ball valve on slowly whilst holding the
outlet hose into the bucket or drain. Air will be ushed through the lter in
a few litres. Once the water clears the inlet ball valve can be turned o and
the lter outlet hose can be connected to the inlet of the ice machine. The
inlet water supply can be slowly turned on. Check for and x any leaks.
Installation and lter change instructions
Recommended Installation
Pressure
Limiting
Valve - optional,
if pressure
is > 900 kPa
Water Flow
Ball Valve
supplied
Stop Cock
Mounting bracket
To remove cartridge
turn in this direction
Filter System HLF 10 Filter System HLF 20
Water Flow
Filter System HLF 20
Filter Housing Head
To install cartridge
turn in this direction
Ice Machine
To Install
To remove cartridge
turn in this direction
Cartridge pushes into
head to install
Cartridge pulls out
of head to remove
To install cartridge
turn in this direction
Filter Life Indicator
3
6
1
Each Hoshizaki lter cartridge comes with a
lter life indicator label for recommended
ecient and hygienic use of the lter.
Simply adhere the label to the lter or in a
convenient location, press the START button
when the lter cartridge is installed and the
label will measure elapsed time till the
6 months recommended use period is
reached.
S
E
R
V
I
C
E
F
I
L
T
E
R
6
M
O
N
T
H
S
SOUTH AUSTRALIA
ADELAIDE (HEAD OFFICE)
PO Box 331
Welland SA 5007
5Toogood Avenue
Beverley SA 5009
Tel: +61 8 8268 1388
Fax: +61 8 8268 1978
VICTORIA - MELBOURNE
and TASMANIA
30Vernon Avenue
Heidelberg Heights
VIC 3081
Australia
Tel: +61 3 9458 3488
Fax: +61 3 9458 2855
NEW SOUTH WALES -SYDNEY
Unit 8, 2 Holker Street
Newington NSW 2127
Australia
Tel: +61 2 9648 6840
Fax: +61 2 9648 6850
QUEENSLAND - BRISBANE
Unit 27, 256-258 Musgrave
Road
Coopers Plains QLD 4108
Australia
Tel: +61 7 3274 5700
Fax: +61 7 3875 1805
WESTERN AUSTRALIA - PERTH
24 Ernest Clark Road
CanningValeWA 6155
Australia
Tel: +61 8 9455 2722
Fax: +61 8 9455 2455
System supplied by Hoshizaki and Water Filter Services Pty Ltd.