~afety—IMPORTANT...PleaseReadcarefui~y.
+Forpe~%oaalsafety9
thk appliancemmtbe
plwperlygrounded.
Electricalreqairemenb
H5-voltmodelsrequirea115/120-
volta.c., 60hzgroundedoutlet
protectedwitha15amptimedelay
fuseor circuitbreaker.
Thepowercordonthesemodelshas
athree-prong(grounding)plugthat
mateswithastandardthree-prong
(grounding)walloutlet(Fig.1)to
minimizethepossibilityofelectric
shockhazardfromtheseappliances.
r
PREFERRED
METHOD
A
—-
—
Fig. 1
iNSUREPROPER
GROUNDEXISTS
BEFORE
USE
1I
?Vhereastandardtwo-prongwall
outletisencountered,itisyour
personalresponsibilityandobligation
tohaveitreplacedwithaproperly
groundedthree-prongwalloutlet.
DONa, um~~Am
CRCWSTANCES,CUT
ORmMomTmTHIRD
(GRom)PRONGmoM
TmPOWERCorn.
230/208-vQlt~odels
requiretheir
ownsinglebranchcircuitsupplying
230/208-volta,c., protectedwitha
timedelayfuseor circuitbreaker.
Thisisrecommendedforbest
performanceandtoprevent
overloadinghousewiringcircuits,
v;hichcouldcauseapossiblefire
hazardfromoverheatingwires.
-.>
<~~>epowercordonthesemodels
~..s‘=~~z.23[}~208-voltperpendicular,
s~LILJ
.‘:~;~~den~or largetandemtypeplug
.,) “
;:-,,>f?,,~~,..-~Coec~jveIywitha
:;:<J6Lma>.ti.)&&..?i
230/208-voltperpendicular,
tandemor largetandemtypewall
outlet.Thesetypesofoutletsare
availableat mosthardwarestores.
Q@
2301208-VOLT MATCHING
PERPENDICULARTYPE WALLOUTLET
LINECORDPLUG
REQUIRES20 AMP TIME DELAYFUSE
ORCIRCUITBREAKERPROTECTION
@@
2~o/208.voLT MATCHING
TANDEMTYPE WALLOUTLET
LINECORDPLUG
REQUIRES15AMP TIME DELAYFUSE
ORCIRCUITBREAKERPROTECTION
@Q
Q
—
@
mm
(’
\
—.
230/208-VOLT MATCHING
LARGETANDEMTYPE WALLOUTLET
LINE CORDPLUG
REQUIRES30 AMP TIME DELAYFUSE
OR CIRCUITBREAKERPROTECTION
Whether yourairconditionerisa
U5-voltora230/208-voltunit, it
isimportanttohavethewall
outletandcircuitcheckedbya
qualifiedelectricianif thereis
anydoubtastowhetheraproper
groundexists.
useOfadapterpIug
(f15-voItmodekonly)
Becauseofpotentialsafetyhazards
undercertainconditions,we
stronglyrecommendagainstuse
ofanadapterp~ugaHowever,
ifyoustillelecttousean adapter,
wherelocalcodespermit,a
TEMPORARY-CONNE~ION
maybemadetoaproperlygrounded
two-prongwalloutletbyuseofa
ULlistedadapter(Fig.2)available
atmostlocalhardwarestores.
TEMPORARYMETI{OO
(ADAPTERPLUGSNOT
PERMITTEDINCANADA) -
P
,,
!
ON
Fig. 2BEFOREUSE
Thelargerslotintheadaptermustbe
alignedwiththelargerslotinthewall
outlettoprovideproperpolarityin
theconnectionofthepowercord.
CAUTION:Attachingtheadapter
groundterminaltowailoutletcover
screwdoesnotgroundtie appliance
urdesscoverscrewismetal,andnot
insulated,andwalloutletisgrounded
throughhousewiring.Youshould
havethecircuitcheckedbyaqualified
electriciantomakesuretheoutlet
isproperlygrounded.
men *onnmting the~wer cord
fromtheadapter,alwaysholdthe
adapterwithonehand.If thisisnot ‘
done,theadaptergroundterrnindis
verylikelytobreakwithrepeateduse.
Shouldtheadapterground
terminalbreak,DON~ USEthe
applianceuntilaproperground
hasagainbeenestablished.
Becauseofpotentialsafety
hazardsundercertainconditions,
westronglyrecomend agtit the
useofanetiensioncord.However,
ifyoustillelecttouseanextension
cord, itisabsolutelynecessarythat
itbeaULlisted3-wiregrounding
typeapplianceextensioncordand
thatthecurrentcarryingratingof
thecordinamperesbeequaltoor
greaterthanthebranchcircuitsize
shownontheratingnameplateof
theappliance.Suchextensioncords
areobtainablethroughyourlocal
serviceorganization.
3