449-5000684 Rev. 1
ŶPOWER
3UHVVWKH32:(5EXWWRQWRWXUQWKHXQLWRQRURII:KHQ
the unit is on,the power indicator light will be green.
:KHQWKHXQLWLVRIIWKHOLJKWZLOOJRRXW
ŶMODE
3XVKWKLVEXWWRQWRF\FOHWKURXJKWKHPRGHVIURP&22/
+($7)$1'5<7KHLQGLFDWRUOLJKWEHVLGHWKH³02'(´
option will illuminate, identifying the mode selected.
• COOL: The range of set temperature is 62°F~86°F.
Cooling begins automatically when the room
temperature is above the set point,and stops when the
URRPWHPSHUDWXUHLV)EHORZWKHVHWSRLQW%XWWKH
FRPSUHVVRUZLOOUXQDPLQLPXPRIPLQXWHVLQ&22/
mode before stopping. The fan is set up from the factory
to run in continuous mode when in cooling.
• HEAT: The range of set temperature is 62°F~84°F.
For heat pump models the unit can alternate running
between reverse cycle heat mode and electric heater
mode according to the difference between the set
temperature and the room temperature. The fan motor
cycles on and off with the compressor and electric
heater.
The indoor fan motors starts before the compressor
and stops after the compressor cycles off.
NOTE: Reverse cycle heating and the electric heater
no not run at the same time. In the following cases, it
is normal that the compressor does not operate.
:KHQWKHRXWGRRUWHPSHUDWXUHLVORZHUWKDQ)RU
the room temperature falls to 8°F below the set point
temperature.
7RSUHYHQWVKRUWF\FOLQJWKHUHLVDPLQXWH
PLQLPXPFRPSUHVVRU2))WLPHEHWZHHQF\FOHV
:KHQIURVWEXLOGVXSWKHFRLOWKHFRPSUHVVRUZLOO
cycle off while the ID fan continues to run to defrost
the coil.
• FAN: Fan operation only without heating and cooling.
NOTE: The set temperature ranges can be changed.
6HH³',36:,7&+(6&21),*85$7,216RQSDJH 6
for details.
• DRY:6HWVXQLWWR&RROPRGHDQGORZIDQVSHHGWRKHOS
with dehumidification.
ŶUP/DOWN BUTTONS ( + / - )
3XVKWKH83RU'2:1EXWWRQWRLQFUHDVHRUGHFUHDVH
the set temperature of the unit in cooling or heating
PRGH7KHWHPSHUDWXUHFDQEHVHWE\LQFUHPHQWVRI)
The set temperature appears in the display.
NOTE: 3UHVVDQGKROGWKH+and - EXWWRQVWRJHWKHUIRU
seconds to change the temperature display between °C
& °F scale.
ŶFAN (FAN SPEED)
(YHU\WLPH\RXSXVKWKLVEXWWRQWKHIDQVSHHGF\FOHV
WKURXJKWKHVHWWLQJVDVIROORZV$872+,*+/2:
Ŷ&2167$17)$1
3URYLGHVFKRLFHRIRSHUDWLQJWKHLQGRRUIDQFRQWLQXRXVO\
RUF\FOLQJLWRQRIIZLWKWKHFRPSUHVVRU$IDQLFRQ
appears near the display when the fan is in constant
PRGH:KHQLQF\FOHPRGHWKHIDQZLOORSHUDWHIRU
several seconds after the compressor cycles off. This
VZLWFKLVQRWDFWLYHLQWKH+HDWPRGH
ŶDISPLAYS:
:KLOHLQ)DQRQO\PRGHLWVKRZVWKHURRPWHPSHUDWXUH
Control and Error code (on some models):
LC 3XVKEXWWRQVRQWKHFRQWUROSDQHODUHQRWDYDLODEOH
The unit can only be operated by using wall thermostat.
FC 3XVKEXWWRQVRQWKHFRQWUROSDQHODQGZDOO
thermostat are not available. The unit can only be
RSHUDWHGE\XVLQJ)5217'(6.&21752/
Error codes:
AS5RRPWHPSHUDWXUHVHQVRUHUURU
ES(YDSRUDWRUWHPSHUDWXUHVHQVRUHUURU
CS&RQGHQVHUWHPSHUDWXUHVHQVRUHUURU
OS2XWVLGHWHPSHUDWXUHVHQVRUHUURU
HS([KDXVWWHPSHUDWXUHVHQVRUHUURU
LE:LUHFRQWUROOHUHUURU
NOTE: :KHQHUURURFFXUVXQSOXJWKHXQLWDQGSOXJLW
back in.If error repeats, call for service.
2WKHUFRGHV
LO5RRPWHPSHUDWXUHLVORZHUWKDQ)
HI5RRPWHPSHUDWXUHLVKLJKHUWKDQ)
FP/RZWHPSHUDWXUHSURWHFWLRQ
NOTE:$OOWKHLOOXVWUDWLRQVLQWKLVPDQXDODUHIRU
H[SODQDWLRQSXUSRVHVRQO\<RXUDLUFRQGLWLRQHUPD\EH
slightly different.
NOTE: This air conditioner is designed to be operated
under the conditions listed above.
NOTE:3HUIRUPDQFHPD\EHUHGXFHGLIRXWVLGHWKHVH
operating temperatures.
USING THE AIR CONDITIONER
Controls
Air Conditioner Controls
&RROLQJ2SHUDWLRQ 2XWGRRU7HPS °F
,QGRRU7HPS °F
+HDWLQJ2SHUDWLRQ 2XWGRRU7HPS °F
,QGRRU7HPS °F