Hours JOG DIAL User manual

-1-
JOG DIAL
User’s Manual
JD-100
㻌
㻌
For Your Safety䠖3
䊠䠊Before You Begin
1-1䠊Overview䠖5㻌
1-2䠊Connecting Method䠖5 㻌
䊡䠊Notes on Use
2-1䠊Parts of the JD-100䠖6
2-2䠊Operating method䠖7 㻌
䊢䠊Specifications
㻌3-1䠊Specifications䠖8
3-2䠊Exterior Dimensions䠖8
CONTENTS

-2-
Notes regarding these materials
࣭These materials are intended as a reference to assist our customers in the use of
the SIGMAKOKI CO., LTD. Product best suited to the customer’s application; they
do not convey any license under any intellectual property rights, or any other rights,
belonging to SIGMAKOKI CO., LTD. or a third party.
࣭SIGMAKOKI CO., LTD. assumes no responsibility for any damage, or infringement
of any third-party’s rights, originating in the use of any product data, diagram, charts,
programs, or algorithms contained in these materials.
࣭All information contained in these materials, including product data, diagrams,
charts, programs and algorithms represents information on products at the time of
publication of these materials, and are subject to change by SIGMAKOKI CO.,LTD.
without notice due to product improvements or other reasons.
࣭When using any or all of the information contained in these materials, including
product data, diagrams, charts, programs, and algorithm, please be sure to evaluate
all information and products. SIGMAKOKI CO., LTD. assumes no responsibility for
any damage, liability or other loss resulting from the information contained herein.
࣭SIGMAKOKI CO., LTD. products are not designed or manufactured for use in
equipment or system that is used under circumstances in which human life is
potentially at stake. SIGMAKOKI CO., LTD. products cannot be used for any
specific purposes, such as apparatus or systems for transportation, vehicular,
medical, aerospace, nuclear, or undersea repeater use.
࣭The prior written approval of SIGMAKOKI CO., LTD. is necessary to reprint or
reproduce in whole or in part these materials.
࣭If these products or technologies are subject to the Japanese export control
restrictions, they must be exported under a license Japanese government and
cannot be imported into a country other than the approved destination.
Any diversion or reexport contrary to the export control laws and regulations of
Japan and/ or the country of destination is prohibited.
㻌
㻌㻌
㻌
㻌
㻌㻌
㻌

-3-
For Your Safety
Before using this product, read this manual and all warnings or cautions in the documentation
provided.
Only Factory Authorized Personnel should be changes and/or adjust the parts of controller.
The Symbols Used in This Manual
!WARNING !CAUTION
This symbol marks warnings that should be read
and used to prevent serious injury or death.
This symbol indicates where caution should be
used to avoid possible injury to yourself or others,
or damage to property.
The above indications are used together with the following symbols to indicate the exact nature of the
warning or caution.
Examples of Symbols Accompanying Warnings and Cautions
ڹSymbols enclosed in a triangle indicate warnings and cautions. The
exact nature of the warning or caution is indicated by the symbol
inside (the symbol at left indicates risk of electrocution).
ۑSymbols enclosed in a circle mark indicate prohibitions(actions that
must not be performed).The exact nature of the prohibition is
indicates by the symbol inside or next to the circle mark (the symbol
at left indicates that the product must not be disassembled).
ەSymbols inside a black circle mark actions that must be performed
to ensure safety. The exact nature of the action that must be
performed is indicated by the symbol inside (the symbol at left is used
in cases in which the AC adapter must be unplugged to ensure safety).
Symbols on the product
The symbol mark on the product calls your attention. Please refer to the manual, in the
case that you operate the part of the symbol mark on the product.
This symbol labeled on the portion calls your attention.
!

-4-
Disclaimer of Liability
ձ SIGMAKOKI CO., LTD. does not accept liability for damages resulting from the use of this
product or the inability to use this product.
ղ SIGMAKOKI CO., LTD. does not accept liability for damages resulting from the use of this
product that deviates from that described in the manual.
ճ SIGMAKOKI CO., LTD. does not accept liability for damages resulting from the use of this
product in extraordinary conditions, including fire, earthquakes, and other acts of God, action by
any third party, other accidents, and deliberate or accidental misuse.
մ If the equipment is used in a manner not specified by the SIGMAKOKI CO., LTD., the protection
provided by the equipment may be impaired.
WARNING
ەDo not use this product in the presence of flammable gas, explosives, or corrosive substances, in
areas exposed to high levels of moisture or humidity, in poorly ventilated areas, or near flammable
materials.
ەDo not connect or check the product while the power is on.
ەInstallation and connection should be performed only by a qualified technician.
ەDo not bend, pull, damage, or modify the power or connecting cables.
ەDo not touch the products internal parts.
ەConnect the earth terminal to ground.
ەShould the product overheat, or should you notice an unusual smell, heat, or unusual noises coming
from the product, turn off the power immediately.
ەDo not turn on the power in the event that it has received a strong physical shock as the result of a
fall or other accident.
ەDo not touch the stage while operation.
ەUse dry clothes only for cleaning the equipment.
!

-5-
Chapter 1: Before You Begin
㻌
㻌㻌
㻌
㻌
1-1. Overview
The JD-100 is a JOG-Dial controller.
It can be connected to our stage controller, SHOT-30* series and SHOT-702 and PGC-04.
The JOG-Dial, connected to the controller via a cable, provides remote operation. This
means that the JOG-Dial allows you to work near the motorized stage while checking its
behavior even if the controller and the motorized stage are away from each other.
1-2. Connecting method
The JOG-Dial (JD-100) is connected to the controller with MDR14-CA cable.
ձ Connect a standard cable (MDR14-CA-*) to the connector on the rear panel of the
JD-100.
ղ Connect the cable from the JD-100 to the “JOYSTICK” connector on the front panel of
the SHOT-30X series and SHOT-702 and PGC-04 controller. (In the case of SHOT-702,
it becomes the rear panel part.)
ճ Turn power switch of the controller on.
Among the LED of “AXIS”, the LED of “1” will light green.
Be sure the controller is off when you connect the JOG-Dial. You may not able
to use the buttons on JOG-Dial if you connect or disconnect either device while
the controller is on.

-6-
Chapter 2: Notes on Use
2-1. Parts of the JD-100
ձղ
ճմ
յն
շ
ո

-7-
2-2. Operating method
ձMODE button
Change an operation mode of the controller.
HOSTЍMANUAL࣭࣭࣭
Refer to a User’s Manual of SHOT-302GS/SHOT-304GS for various modes.
NOTE) IN SHOT-702/ PGC-04, the MODE change is invalid.
ղRATE button
Switch the amount of movement of the stage for the dial operation.
The LED indicator lights up : 5pulse/ 1click for JOG-dial. (High-RATE)
The LED indicator lights down: 1pulse/ 1click for JOG-dial. (Normal-RATE)
ճAXIS-SEL button
Selects the axis operated by JOG-Dial.
Change the number of lightning of LED indicator by the AXIS-SEL button every time
pushing the button. (1Ѝ2Ѝ3Ѝ4Ѝ1࣭࣭࣭)
մSPEED button
Cycle through “SPEED 1/2/3/4” settings stored in controller’s memory switches (1Ѝ2Ѝ3Ѝ
4Ѝ1࣭࣭࣭).
յ,նJOG-/ JOG+ button
Enables operation of selects-axis. Pressing of this button continuously moves the stage
continuously. Releasing this button stops the stage.
շAXIS LED
Change the number of lightning of LED indicator by the AXIS-SEL button every time
pushing the button. (1Ѝ2Ѝ3Ѝ4Ѝ1࣭࣭࣭)
ոJOG-dial
The JOG-dial for operating the stage.
Left rotation : 㸫direction
Right rotation : + direction

-8-
Chapter 3: Specifications
㻌
㻌㻌
㻌
3-1. Specifications
Power source DC5V s10% ( from controller)
Operating temperature 5㹼40Υ
Storage temperature -20㹼60Υ
Ambient humidity 20㹼80%RH(no condensation)
External dimensions 130W145D36H(excluding projections)
Weight 560g
Indoor use only
Altitude Up to 2000m
Installation category ϩ
Pollution degree 2
3-2. Exterior Dimensions
This manual suits for next models
1
Table of contents
Popular Control Unit manuals by other brands

DOMIQ
DOMIQ Base Installation leaflet

Siemens
Siemens MXG461B Series Technical instructions

HYDAC FILTER SYSTEMS
HYDAC FILTER SYSTEMS CTM-EB 1000 Series Operating and maintenance instructions

Stern Engineering
Stern Engineering Jupiter 2040 Installation and maintenance guide

Siemens
Siemens FDCI723 manual

Mitsubishi Electric
Mitsubishi Electric MELSEC iQ-R RD78G4 user manual