34E Series – Endless Design
Double Duty – Deli
• PRODUCT SPECIFICATIONS SHEETS
• Specification subject to change without notice
• Cases are designed to operate at 75 degrees Fahrenheit and 55% relative humidity
Self-Contained SC-CDS34E-4 SC-CDS34E-6 SC-CDS34E-8 SC-CDS34E-10 SC-CDS34E-12
Remote R-CDS34E-4 R-CDS34E-6 R-CDS34E-8 R-CDS34E-10 R-CDS34E-12
Length with (2) ends 52-1/2" 76-1/2" 100-1/2" 124-1/2" 148-1/2"
Length without ends 48" 72" 96" 120" 144"
Height with ends 53-1/2" 53-1/2" 53-1/2" 53-1/2" 53-1/2"
Height without ends 53" 53" 53" 53" 53"
Depth with ends 34-1/2" 34-1/2" 34-1/2" 34-1/2" 34-1/2"
Depth without ends 34" 34" 34" 34" 34"
Depth with bottom door 37-1/2" N/A N/A N/A N/A
Endless Design YES YES YES YES YES
(Dimensions are +/-1/4")
34E Series – Endless Design
Double Duty – Deli
Standard Specifications and Optional Features
OPTIONAL FEATURES
A Division of HMC Enterprises LLC • 2501 Grant Avenue • Philadelphia, PA 19114 USA
(215) 464-6800 • 1-800-344-8222 • Fax (215) 969-4890 • E-Mail: sales@howardmccray.com • www.howardmccray.com
UL Classified to ANSI/NSF 7
Foamed in place CFC free foam
Triple pane insulated front glass-28"H
Heavy gauge steel super structure
Bottom storage
Endless design allows for continuous line up
Drain is included for cleaning
Satin finish extrusion on doors and door tracks
Designer white exterior front and ends
Stainless steel mirror trim
Stainless steel heavy gauge top – 19-1/2" W
Designer white exterior rear
CONSTRUCTION FINISHES
INTERIOR REFRIGERATION
EXTERIOR LIGHTING
ELECTRICAL REQUIREMENTS
Designer white interior ends
Stainless steel heavy gauge mezzanine shelf
Anodized aluminum floor (bottom storage area)
Air insulated baffle (prevents moisture from drip-
ping into display area)
Copevap system (eliminates need for condensate pan)
R134a expansion valve system
Gravity coil located at inside top of unit and bot-
tom storage area
Self contained system
Automatic defrost controlled by time clock-(self
contained units only)
Pressure control maintains constant temperatures
Remotes available
Double pane rear removable doors
Newly designed rear compression door jamb
Removable front grille allows for cleaning
Removable rear grille for easy servicing
2-1/4" removable end panels
2 Rows of T12 lighting at top of unit
115V/60Hz/1Ph
Unit must be hard wired
UL/CUL listed
115V-12AMP general purpose receptacle (wired
separately)
Scale Stand
Paper cutter
Painted, laminate or stainless steel
Mirrored doors
Extra stainless steel mezzanine shelf
Drop work shelf
Front bumpers 1" or 3"
Door lock
Digital thermometer
Pass thru front doors
Sandwich racks
Salad pan settings
Important Note: All refrigerated cases are
designed to operate in an environment of
75 degrees and 55% relative humidity.
Important Note: Product must be cooled
before being displayed within the case.
A Division of HMC Enterprises LLC • 2501 Grant Avenue • Philadelphia, PA 19114 USA
(215) 464-6800 • 1-800-344-8222 • Fax (215) 969-4890 • E-Mail: sales@howardmccray.com • www.howardmccray.com
34E Series – Endless Design
Double Duty – Deli
Technical Data
SHIPPING INFORMATION
Model Self contained SC-CDS34E-4 SC-CDS34E-6 SC-CDS34E-8 SC-CDS34E-10 SC-CDS34E-12
Remote R-CDS34E-4 R-CDS34E-6 R-CDS34E-8 R-CDS34E-10 R-CDS34-E-12
52-1/2"
48"
53-1/2"
53"
34-1/2"
34"
YES
76-1/2"
72"
53-1/2"
53"
34-1/2"
34"
YES
100-1/2"
96"
53-1/2"
53"
34-1/2"
34"
YES
124-1/2"
120"
53-1/2"
53"
34-1/2"
34"
YES
148-1/2"
144"
53-1/2"
53"
34-1/2"
34"
YES
Length with (2) ends
Length without ends
Height with ends
Height without ends
Depth with ends
Depth without ends
Endless design
(Dimensions are +/- 1/4")
White
Stainless
White
Anodized
2
20-1/2"X23-1/2"
2
Yes
28"X46-11/16"
2
24"x28-5/8"
30
Standard
White
Stainless
White
Anodized
2
31"X23-1/2"
2
Yes
28"X70-11/16"
3
24"x28-5/8"
45
Standard
White
Stainless
White
Anodized
4
20-1/2"X23-1/2"
2
Yes
28"X94-11/16"
4
24"x28-5/8"
60
Standard
White
Stainless
White
Anodized
4
25-3/4"X23-1/2"
2
Yes
28"X118-11/16"
5
24"x28-5/8"
75
Standard
White
Stainless
White
Anodized
4
31"X23-1/2"
2
Yes
28"X142-11/16"
6
24"x28-5/8"
90
Standard
Exterior color
Interior color
Inside end panels
Floors
# of top doors
Door size
# of coils
Bottom storage
Front glass
# of main deck shelves
Main deck size
Cubic capacity (ft3)
Mezzanine- Shelf
36°F to 40°F
R134a
1/4
30
12
1 per day
1400
115V
6.0A
0.8A
No
36°F to 40°F
R134a
1/3
30
12
1 per day
2100
115V
8.7A
1.3A
No
36°F to 40°F
R134a
1/2
30
12
1 per day
2800
115V
11.2A
1.6A
No
36°F to 40°F
R134a
1/2
30
12
1 per day
3500
115v
13.8A
2.4A
No
36°F to 40°F
R134a
3/4
30
12
1 per day
4200
115V
17.4A
2.4A
No
Operating temperature
Refrigerant (expansion valve)
Compressor size HP
Pressure control settings
@ 75°F, 55%RH
Defrost per day (24 hours)
BTU’s at +20°F Evap. Temp.
Voltage
Amperage
Amperage, lights only
Cord and plug
Self contained
Self contained
CUT IN
CUT OUT
Air Defrost
Remote
Self contained
Remote
58"
44"
61"
530#
497#
89ft3
58"
44"
87"
741#
693#
128ft3
58"
44"
109"
897#
832#
164ft3
58"
44"
135"
1150#
1089#
199ft3
58"
44"
157"
1414#
1359#
231ft3
Height
Depth
Length
Gross weight
Cubic feet
Self contained
Remote
• Cases are designed to operate at 75 degrees Fahrenheit and 55% relative humidity
• Cases are equipped with drains; check your local building codes for connection requirements.
• Specification subject to change without notice

This manual suits for next models

12

Other Howard McCray Merchandiser manuals

Howard McCray R-CDS32E-4 User manual

Howard McCray

Howard McCray R-CDS32E-4 User manual

Howard McCray R-CMS32E-4 User manual

Howard McCray

Howard McCray R-CMS32E-4 User manual

Howard McCray R-CDS40E-4C User manual

Howard McCray

Howard McCray R-CDS40E-4C User manual

Howard McCray R-S32E-3 User manual

Howard McCray

Howard McCray R-S32E-3 User manual

Howard McCray R-CMS35-10 User manual

Howard McCray

Howard McCray R-CMS35-10 User manual

Howard McCray R-CBS40E-4C User manual

Howard McCray

Howard McCray R-CBS40E-4C User manual

Howard McCray R-D32E-3-LS User manual

Howard McCray

Howard McCray R-D32E-3-LS User manual

Howard McCray R-OD30E-3L-LS User manual

Howard McCray

Howard McCray R-OD30E-3L-LS User manual

Howard McCray CHS35-4 User manual

Howard McCray

Howard McCray CHS35-4 User manual

Howard McCray HAP46-2 User manual

Howard McCray

Howard McCray HAP46-2 User manual

Howard McCray R-CFS40E-4C User manual

Howard McCray

Howard McCray R-CFS40E-4C User manual

Howard McCray R-OP30E-3L-LS User manual

Howard McCray

Howard McCray R-OP30E-3L-LS User manual

Howard McCray R-CMS34E-10 User manual

Howard McCray

Howard McCray R-CMS34E-10 User manual

Howard McCray R-CMS40E-4C User manual

Howard McCray

Howard McCray R-CMS40E-4C User manual

Howard McCray R-CFS32E-4 User manual

Howard McCray

Howard McCray R-CFS32E-4 User manual

Howard McCray R-CDS32E-4 User manual

Howard McCray

Howard McCray R-CDS32E-4 User manual

Howard McCray R-CFS40E-12 User manual

Howard McCray

Howard McCray R-CFS40E-12 User manual

Howard McCray R-M32E-3-LS User manual

Howard McCray

Howard McCray R-M32E-3-LS User manual

Howard McCray R-CDS32E-4 User manual

Howard McCray

Howard McCray R-CDS32E-4 User manual

Howard McCray R-ODA32E-6 User manual

Howard McCray

Howard McCray R-ODA32E-6 User manual

Howard McCray R-CFS32E-4 User manual

Howard McCray

Howard McCray R-CFS32E-4 User manual

Howard McCray R-OM30E-3L-LS User manual

Howard McCray

Howard McCray R-OM30E-3L-LS User manual

Howard McCray R-CFS32E-4 User manual

Howard McCray

Howard McCray R-CFS32E-4 User manual

Howard McCray R-OS30E-3 User manual

Howard McCray

Howard McCray R-OS30E-3 User manual

Popular Merchandiser manuals by other brands

Hussmann MD Series Installation & operation manual

Hussmann

Hussmann MD Series Installation & operation manual

Arctic Air Commercial Glass-Top Merchandiser ST05G brochure

Arctic Air

Arctic Air Commercial Glass-Top Merchandiser ST05G brochure

Hussmann FWE Technical data sheet

Hussmann

Hussmann FWE Technical data sheet

Hussmann IMPACT Elite ES1S Technical data sheet

Hussmann

Hussmann IMPACT Elite ES1S Technical data sheet

Hussmann LGH Technical data sheet

Hussmann

Hussmann LGH Technical data sheet

Hussmann RI2N Technical data sheet

Hussmann

Hussmann RI2N Technical data sheet

Tyler Advantage Series Installation & service manual

Tyler

Tyler Advantage Series Installation & service manual

Hussmann IMPACT EDS1 Technical data sheet

Hussmann

Hussmann IMPACT EDS1 Technical data sheet

Global Solutions GS1400-16 user manual

Global Solutions

Global Solutions GS1400-16 user manual

Hussmann M62 install guide

Hussmann

Hussmann M62 install guide

Viessmann TECTODECK MD1 SPIRIT PLUS user guide

Viessmann

Viessmann TECTODECK MD1 SPIRIT PLUS user guide

Hussmann MAXI- owner's manual

Hussmann

Hussmann MAXI- owner's manual

Hussmann GWIC install guide

Hussmann

Hussmann GWIC install guide

Randell 4137DT Specifications

Randell

Randell 4137DT Specifications

True GEM-72 Specifications

True

True GEM-72 Specifications

EPTA iarp SMART N.3 I-P M ES Use and maintenance

EPTA

EPTA iarp SMART N.3 I-P M ES Use and maintenance

Hussmann D5-EP datasheet

Hussmann

Hussmann D5-EP datasheet

Mainstreet Equipment 829GMC12B user manual

Mainstreet Equipment

Mainstreet Equipment 829GMC12B user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.