The Hozelock Cyprio Cascade 700 pump is
designed for submersible use only. The pump
does not use oil or grease for lubrication and
can be used safely in ponds containing fish or
plants. The motor consists of a sealed stator
and water-cooled permanent magnet rotor.
All electrical components are isolated from
the water.
IMPORTANT
1. WARNING: ALWAYS UNPLUG OR
DISCONNECT ALL APPLIANCES IN THE
POND FROM THE ELECTRICITY SUPPLY
BEFORE PUTTING YOUR HANDS IN THE
WATER WHILST EQUIPMENT IS BEING
INSTALLED, REPAIRED, MAINTAINED OR
HANDLED.
2. Do not use the supply cable to lift the
pump, as this may cause damage. We
recommend fitting a lifting cord to the
handle eye on the top of the strainer cage
when the pump is installed in deep water.
See fig 1.
3. Do not operate or leave the pump in
freezing conditions.
4. Do not allow the pump to run dry.
5. Check that the voltage marked on the
pump corresponds to the mains supply.
6. A 10MA OR 30 MA RESIDUAL CURRENT
DEVICE MUST BE FITTED TO THE MAINS
SUPPLY.
7. DO NOT OPERATE THIS PUMP WITHOUT
THE STRAINER CAGE ATTACHED. USING
THE PUMP WITHOUT A STRAINER MAY
INVALIDATE YOUR WARRANTY.
WARNING: SAFETY AND
ELECTRICAL CONNECTIONS
1. The pump is supplied with 10m of 3 core
electric cable which is permanently
connected and sealed to the motor.
The supply cable cannot be replaced. If the
cable is damaged, the pump should be
discarded.
This product is designed to be
permanently wired to the mains supply in
a dry weatherproof enclosure through a
Double-Pole Switched Fused Spur -
(Disconnector) to BS 3676, with a
minimum contact separation of 3mm in
each Pole - Fitted with a 3 or 5 Amp fuse.
The installation must conform to the
national and local wiring regulations
which could include the use of plastic or
metal conduit to protect the cable.
2. A 10MA OR 30MA RESIDUAL CURRENT
DEVICE (RCD) MUST BE FITTED TO THE
MAINS SUPPLY.
3. WARNING: THIS APPLIANCE MUST BE
EARTHED AND IT IS ESSENTIAL THAT THE
CONNECTIONS ARE MADE USING THE
FOLLOWING CODE;
Brown - Live
Blue - Neutral
Green/Yellow - Earth
The BROWN lead should be connected to
the LIVE terminal which may be marked
with an ‘L’ or coloured brown or red.
The BLUE lead should be connected to the
NEUTRAL terminal which may be marked
with an ‘N’ or coloured blue or black.
The GREEN/YELLOW lead should be
connected to the EARTH terminal which
may be marked with an ‘E’ or coloured
green or green/yellow.
4. If an extension cable is required, this
should be connected to the end of the
pump cable using a weatherproof cable
connector. The joint must be positioned in
a suitable weatherproof housing. The
extension cable should be of 3 core
0.75mm2Polychloroprene rubber insulated
cable (ref: HO5 RN-F) and permanently
wired to the mains supply with a 3 or 5
Amp fuse.
5. The pump cable (and extension cable)
should be positioned and adequately
protected against damage especially
where contact with gardening equipment
(lawn mowers, forks etc..) children and
domestic animals may occur.
6. CONSULT A QUALIFIED ELECTRICIAN OR
LOCAL AUTHORITY IF IN ANY DOUBT
ABOUT WIRING TO THE MAINS SUPPLY.
ACCESSORY ASSEMBLY
Telescopic Stem Assembly.
Take the outer telescopic stem ‘A’ and slide
the inner stem ‘B’ into it, as shown. See Fig 2.
Bell Fountain
1. Locate the Bell Support (D) to the Bell
Main Body (E) and push fully home.
2. Position the Bell (F) to the Body Assembly
and press into the central location.
See fig 3.
PUMP INSTALLATION
Position
Construct a solid and level platform on which
to place the pump. Which using spray
fountains, the top of the platform should be
240-330mm (10-13”) below the water surface.
When using the bell fountain, the top of the
platform should be 100mm (4”) below the
water level.
A typical installation is shown for guidance in
fig 4.
Flow Control
The flow from the pump can be regulated to
meet your needs by rotating the flow
controller wheel (G) near the outlet of the
pump. See Fig 5.
Fountain Only
1. Place the pump next to the pond and route
the cable back to the mains supply.
2. Select the desired fountain accessory. The
2 and 3 tier fountainheads simply snap
onto the fountain stem (See Fig 6). The
fountain stem pushes onto the narrower
tube section of the telescopic fountain
stem (See Fig 6). Then place the pump in
the desired position. Note: Check that the
inner stem of the telescopic tube has not
been pushed inside the outer tube.
3. a). 3 tier fountain – Creates a wide and
attractive fountain spray.
b). 2 tier fountain – Creates a higher and
narrower display.
c). Bell fountain – Creates a decorative
water bell. Adjust the telescopic stem to
the required height and regulate the bell
by rotating the flow controller by the
outlet of pump.and by sliding the inner
bell in and out of the bell assembly.
4. The ball joint - See Fig 5 (H), fits onto the
pump outlet and the telescopic stem
pushes onto the top. This can then be used
to adjust the fountain angle so that it is
vertical.
Waterfall Only
1. Fit a suitable length of hose 12.5mm bore
hose on to the hose adaptor. See Fig 5 (I).
2. Route the hose back to the waterfall.
MAINTENANCE
The Hozelock Cyprio range of Cascade pumps
has been designed to allow fast and easy
maintenance. As with all pumps of its kind,
occasionally it will become necessary to clean
the Strainer Cage and Fountain Spray head
ring.
ALWAYS UNPLUG OR DISCONNECT ALL
APPLIANCES IN THE POND FROM THE
ELECTRICITY SUPPLY BEFORE PUTTING YOUR
HANDS IN THE WATER OR STARTING
MAINTENANCE.
Fountain Head
1. Place a coin or similar in the slot and
gently lever off the fountain head.
2. Rinse in clean water and reassemble.
Strainer.
Cascade 700
INSTALLATION AND OPERATING INSTRUCTIONS. READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
GB
3352
ATTENTION
AUTOMATIC CUT-OUT. To help ensure
your pump’s long life and to prevent
damage, it is fitted with automatic
thermal overload protection. This
switches off the pump if it overheats. If
this occurs, switch off the power at the
mains supply to the pump. Check for the
cause. Usually it will be debris blocking
the inlets of the pump or obstructing
the impeller. Remove the obstruction
and wait 15 minutes for the pump to
cool down and automatically reset. Then
switch on the pump again.
NOTE: YOU MUST SWITCH OFF THE
MAINS SUPPLY BEFORE THE PUMP WILL
RESET.
From 1st January 2005 installing this
product in the garden is classed as
'notifiable' in the revised Building
Regulations for England and Wales. The
Regulations now require you to tell
your local authority building control
department that you intend to install
this product before installation. Your
local authority will let you know how
you can get your installation approved.
1. Remove the accessories from the pump
outlet.
2. Holding the pump in one hand, press the
release button (J) on the top of the pump
and open Strainer Cage. See Fig 5.
3. Slide the pump out of its location and
wash/rinse the Strainer Cage with clean
water. The hinges on the Strainer Cage
should also be washed clean at this time.
4. Reassemble the pump.
Rotor Assembly
1. Remove the Strainer Cage as described
above.
2. Release the Pump Chamber, Fig 7 (K), by
rotating it until the two retaining tongues
are clear of the lugs on the Motor Body.
3. Gently pull the Pump Chamber squarely
away from the Motor Body.
4. Pull the Rotor Assembly out of the Motor
Body. See Fig 7 (L).
5. Wash out all of the components in clean
water. Do not use detergents or other
chemical cleaners.
6. Replace the Rotor Assembly into the
Motor Body and refit the Pump Chamber
and Strainer Cage.
ALL YEAR PUMP CARE
A quick daily check should be carried out to
ensure that the pump is performing
satisfactorily.
Once a week- Remove and clean the Strainer
Cage and Fountain Head in accordance with
the general maintenance notes. Depending
on pond water conditions, cleaning may be
required more frequently.
Once a year- Completely disassemble the
pump including the Rotor Assembly as
described in the general maintenance notes
and wash all components in clean, fresh
water. Replace worn or broken parts.
SPARE PARTS
Contact the Consumer Services Helpline on
01844 292002
HOZELOCK CYPRIO 3 YEAR
GUARANTEE
If this pump, excluding the Rotor Assembly,
becomes unserviceable within 3 years of the
date of purchase it will be repaired or
replaced at our option free of charge, unless
in our opinion it has been damaged or
misused.
Liability is not accepted for damage due to
accident, improper installation or use.
Liability is limited to replacement of a faulty
pump. This guarantee is not transferable. It
does not affect your statutory rights.
To obtain the benefits of the guarantee,
firstly contact Hozelock Cyprio Consumer
Services who may request that the pump is
sent along with proof of purchase directly to
the address below.
DAMAGE CAUSED BY RUNNING THE PUMP
DRY OR BY FROST INVALIDATES THE
GUARANTEE.
FAULT FINDING
WARNING: ALWAYS UNPLUG OR
DISCONNECT ALL APPLIANCES IN THE
POND FROM THE ELECTRICITY SUPPLY
BEFORE PUTTING YOUR HANDS IN THE
WATER WHILST EQUIPMENT IS BEING
INSTALLED, REPAIRED, MAINTAINED OR
HANDLED.
IMPORTANT - PLEASE KEEP THIS
SECTION FOR REFERENCE
LOW FLOW FROM PUMP
1. Ensure the Strainer Cage is clean.
2. A small diameter outlet pipe will
restrict outlet flow.
3. Clear any blockages and adjust the flow
controls.
NO FLOW FROM PUMP
1. Check power supply is on.
2. Check fuse and wiring.
3. Check the Rotor Assembly is not
jammed, damaged or showing signs of
excessive wear.
4. Ensure the Strainer Cage is clean.
POOR FOUNTAIN DISPLAY.
1. Clean the Fountain Head. (see
maintenance).
Hozelock Cyprio
Haddenham, Aylesbury, Bucks. HP17 8JD.
England.
Tel: +44 (0)1844 292002 Fax: +44 (0)1844 291820
www.hozelock.com
The Aquatics Division of Hozelock Group
33439-000
JG
I
Fig. 1
F
D
E
Fig. 6
Fig. 4
Fig. 7
L
K
Fig. 5 Fig. 3
Fig. 2
A
B
H
Item Numbers
1. Pump Chamber and Seal. Z13248
2. Rotor Assembly. 3419
3. Strainer Cage. Z13225
4. Fountain Kit. 3426

Other manuals for Cascade 700

2

This manual suits for next models

1

Other Hozelock Cyprio Pond Pump manuals

Hozelock Cyprio Aquaforce Series User manual

Hozelock Cyprio

Hozelock Cyprio Aquaforce Series User manual

Hozelock Cyprio Cascade 5500 User manual

Hozelock Cyprio

Hozelock Cyprio Cascade 5500 User manual

Hozelock Cyprio EasyClear 3000 1760 User manual

Hozelock Cyprio

Hozelock Cyprio EasyClear 3000 1760 User manual

Hozelock Cyprio EasyClear 6000 User manual

Hozelock Cyprio

Hozelock Cyprio EasyClear 6000 User manual

Hozelock Cyprio Aquaforce Series User manual

Hozelock Cyprio

Hozelock Cyprio Aquaforce Series User manual

Hozelock Cyprio Cascade 1500 User manual

Hozelock Cyprio

Hozelock Cyprio Cascade 1500 User manual

Hozelock Cyprio Aquaforce Series User manual

Hozelock Cyprio

Hozelock Cyprio Aquaforce Series User manual

Hozelock Cyprio EASYCLEAR 3000LV User manual

Hozelock Cyprio

Hozelock Cyprio EASYCLEAR 3000LV User manual

Hozelock Cyprio Cascade 4000 User manual

Hozelock Cyprio

Hozelock Cyprio Cascade 4000 User manual

Hozelock Cyprio Cascade 3000 User manual

Hozelock Cyprio

Hozelock Cyprio Cascade 3000 User manual

Hozelock Cyprio EASYCLEAR 3000 User manual

Hozelock Cyprio

Hozelock Cyprio EASYCLEAR 3000 User manual

Popular Pond Pump manuals by other brands

fish mate 9000 instructions

fish mate

fish mate 9000 instructions

Profi-pumpe Rügen operating instructions

Profi-pumpe

Profi-pumpe Rügen operating instructions

Oase Profimax 20.000 operating instructions

Oase

Oase Profimax 20.000 operating instructions

Oase AquaMax Eco Expert 26000 operating instructions

Oase

Oase AquaMax Eco Expert 26000 operating instructions

Tsurumi Pump PL Series Instructions & maintenance

Tsurumi Pump

Tsurumi Pump PL Series Instructions & maintenance

Oase FP 2500 operating instructions

Oase

Oase FP 2500 operating instructions

Oase Water Trio operating instructions

Oase

Oase Water Trio operating instructions

EasyPro TH Series Instructions for Operation, Safety, Warranty

EasyPro

EasyPro TH Series Instructions for Operation, Safety, Warranty

Oase 525 operating instructions

Oase

Oase 525 operating instructions

Pontec PondoTronic UVC 18 operating instructions

Pontec

Pontec PondoTronic UVC 18 operating instructions

T.I.P. WP 500-10 R operating instructions

T.I.P.

T.I.P. WP 500-10 R operating instructions

ubbink AcquaArte Nova Scotia quick start guide

ubbink

ubbink AcquaArte Nova Scotia quick start guide

Homewell HMW-ARP2000 instruction manual

Homewell

Homewell HMW-ARP2000 instruction manual

Pontec PondoMax Eco 2500 operating instructions

Pontec

Pontec PondoMax Eco 2500 operating instructions

ubbink Cascademax Directions for use

ubbink

ubbink Cascademax Directions for use

Oase 57384 operating instructions

Oase

Oase 57384 operating instructions

Oase Varionaut 150 24V/DMX/02 operating instructions

Oase

Oase Varionaut 150 24V/DMX/02 operating instructions

Oase AquaOxy 450 operating instructions

Oase

Oase AquaOxy 450 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.