HP E2416B User manual

User’s Guide
Publication Number E2416-97002
June 1998
For Safety Information, Warranties, and Regulatory Information, see the
pages at the end of this manual.
Copyright Hewlett-Packard Company 1993 - 1998
All Rights Reserved.
HP E2416B Analysis Probe for
Intel 80196

The HP E2416B Analysis Probe — At a Glance
The HP E2416B Analysis Probe provides a complete interface for
state or timing analysis between any compatible 80196 PLCC target
system and HP logic analyzers. The supported logic analyzers are
listed in chapters 1. A microprocessor is defined as compatible if it
conforms to the 80196 architecture, uses the 80196 instruction set,
and uses the 68-pin PLCC pinout. This includes 8096, 8097, AH
versions, -90 versions, BH versions, and 80C196KA/KB/KC/KD.
The analysis probe provides the physical connection between the
target microprocessor and the logic analyzer. The configuration
software on the enclosed disks set up the logic analyzer for
compatibility with the analysis probe. The inverse assemblers on the
disks let you obtain displays of the 80196 data in 80196 assembly
language mnemonics.
If you are using the analysis probe with the HP 16600 or HP 16700
series logic analysis systems, you only need this manual as a
reference. The HP 16600 and 16700 series contain a Setup Assistant,
which guides you through the connection and configuration process
using on screen dialog windows. For an overview of Setup Assistant,
refer to Chapter 1, "Setup Assistant."
For more information on the logic analyzers or microprocessor, refer
to the appropriate reference manuals for those products.
ii HP E2416B 80196 Analysis Probe

Analyzing a Target System with the HP E2416B Analysis Probe
The HP E2416B AnalysisProbe — Ata Glance
HP E2416B 80196 Analysis Probe iii

In This Book
This book is the User’s Guide for the HP E2416B Analysis Probes. It assumes
that you have a working knowledge of the logic analyzer used and the
microprocessor being analyzed.
This user’s guide is organized into the following chapters:
Chapter 1 contains overview information, including a list of required
equipment.
Chapter 2 explains how to connect the logic analyzer to your target
system through the analysis probe, and how to configure the analysis
probe and logic analyzer to interpret target system activity. The last
section in this chapter shows you how to hook up optional equipment
to obtain additional functionality.
HP 16600 and HP 16700 Series Logic Analysis Systems
If you are using the analysisprobe with HP16600or HP 16700 serieslogic
analysissystems, youonly need this manual as areference for obtaining and
interpretingdata. The HP 16600 and HP 16700 contain a Setup Assistant, which
guides youthroughthe connection and configuration processusing on screen
dialog windows. For an overview of Setup Assistant, refer to chapter 1, "Setup
Assistant."
Chapter 3 provides information on analyzing the supported
microprocessors.
Chapter 4 contains reference information on the analysis probe.
Chapter 5 contains troubleshooting information.
Configuring
Connecting &
Configuring
Your System
Chapter 2
Connecting
the Analysis
Probe to the
Target System
Analyzing the
Target System
Chapter 3
Connecting
Optional
Equipment
Overview
Chapter 1
Reference
Chapter 4
If You Have
a Problem
Chapter 5
Connecting
the Analysis
Probe to the
Logic Analyzer
iv HP E2416B 80196 Analysis Probe

Contents
The HP E2416B Analysis Probe — At a Glance ii
1 Overview
Setup Assistant 1–3
Logic Analyzers Supported 1–4
Logic analyzer software version requirements 1–5
Equipment Used with the Analysis Probe 1–6
Equipment supplied 1–6
Minimum equipment required 1–8
Additional equipment supported 1–8
2 Connecting and Configuring Your System
Power-on/Power-off Sequence 2–4
To power on HP 16600 and HP 16700 series logic analysis systems 2–4
To power on all other logic analyzers 2–4
To power off 2–4
Connecting the Analysis Probe to the Target System 2–5
To connect to a PLCC target system 2–6
Connecting the Analysis Probe to the Logic Analyzer 2–8
Analysis probe pod locations 2–9
To connect to the HP 16600A logic analysis system 2–10
To connect to the HP 16601A logic analysis system 2–11
To connect to the HP 16602A logic analysis system 2–12
To connect to the HP 16603A logic analysis system 2–13
To connect to the HP 16550A logic analyzer 2–14
To connect to the HP 16554/55/56 logic analyzers 2–15
To connect to the HP 1660A/AS/C/CS/CP logic analyzers 2–16
To connect to the HP 1661A/AS/C/CS/CP logic analyzers 2–17
Contents-1

To connect to the HP 1662A/AS/C/CS/CP logic analyzers 2–18
To connect to the HP 1670A/D logic analyzer 2–19
To connect to the HP 1671A/D logic analyzer 2–20
To connect to the HP 1672A/D logic analyzer 2–21
Configuring 2–22
Configuring the Analysis Probe 2–23
Configuring the Logic Analysis System 2–24
To load configuration and inverse assembler files — HP 16600/700 logic analy-
sis systems 2–25
To load configuration and inverse assembler files — other logic analyzers 2–
26
Connecting Optional Equipment 2–28
3 Analyzing the Target System
Analyzing the Target System 3–2
Modes of Operation 3–3
State-per-transfer mode 3–3
State-per-clock mode 3–3
Timing mode 3–3
Logic Analyzer Configuration 3–4
Trigger specification 3–4
Format specification display 3–4
Logic Analyzer Symbols 3–6
Modifying the trigger menu 3–8
Contents
Contents-2

Using the Inverse Assemblers 3–9
To display captured state data 3–10
To align the inverse assembler 3–11
Inverse assembler output format 3–12
Inverse assembler error messages 3–12
4 Reference
Operating characteristics of the analysis probe 4–3
Theory of operation and clocking 4–5
State-per-transfer mode 4–5
State-per-clock mode 4–5
Timing mode 4–6
Signal-to-connector mapping 4–8
Circuit board dimensions 4–13
Replaceable parts 4–14
5 If You Have a Problem
Analyzer Problems 5–3
Intermittent data errors 5–3
Unwanted triggers 5–3
No activity on activity indicators 5–4
No trace list display 5–4
Analyzer won’t power up 5–4
Analysis Probe Problems 5–5
Target system will not boot up 5–5
Erratic trace measurements 5–6
Capacitive loading 5–6
Inverse Assembler Problems 5–7
No inverse assembly or incorrect inverse assembly 5–7
Inverse assembler will not load or run 5–8
Intermodule Measurement Problems 5–9
Contents
Contents-3

An event wasn’t captured by one of the modules 5–9
Analyzer Messages 5–10
“. . . Enhanced Inverse Assembler Not Found” 5–10
“. . . Inverse Assembler Not Found” 5–10
“. . . Does Not Appear to be an Inverse Assembler File” 5–10
“Measurement Initialization Error” 5–11
“No Configuration File Loaded” 5–14
“Selected File is Incompatible” 5–14
“Slow or Missing Clock” 5–14
“Time from Arm Greater Than 41.93 ms” 5–15
“Waiting for Trigger” 5–15
Cleaning the Instrument 5–16
Glossary
Index
Contents
Contents-4

1
Overview

Overview
This chapter describes:
•Setup Assistant
•Logic analyzers supported
•Logic analyzer software version requirements
•Equipment used with the analysis probe
•Equipment supplied
•Minimum equipment required
•Additional equipment supported
Configuring
Connecting &
Configuring
Your System
Chapter 2
Connecting
the Analysis
Probe to the
Target System
Analyzing the
Target System
Chapter 3
Connecting
Optional
Equipment
Overview
Chapter 1
Reference
Chapter 4
If You Have
a Problem
Chapter 5
Connecting
the Analysis
Probe to the
Logic Analyzer
1-2 HP E2416B 80196 Analysis Probe

Setup Assistant
Setup Assistant is an online tool for connecting and configuring your
logic analysis system for microprocessor and bus analysis. Setup
Assistant is available on the HP 16600 and HP 16700 series logic
analysis systems. You can use Setup Assistant in place of the
connection and configuration procedures provided in chapter 2.
This menu-driven tool will guide you through the connection
procedures for connecting the logic analyzer to an analysis probe, an
emulation module, or other supported equipment. It will also guide
you through connecting an analysis probe to the target system.
Access Setup Assistant by clicking its icon in the Logic Analysis
System window. The on-screen dialog prompts you to choose the
type of measurements you want to make, the type of target system,
and the associated products that you want to set up.
If you ordered this product with your HP 16600/700 logic analysis
system, the logic analysis system has the latest software installed,
including support for this product. If you received this product after
you received your logic analysis system, this product might not be
listed under supported products. In that case, you need to install the
I80196Kx Processor Support Package. Use the procedure on the
CD-ROM jacket to install the I80196Kx Processor Support Package.
HP E2416B 80196 Analysis Probe 1-3

Logic Analyzers Supported
The table below lists the logic analyzers supported by the HP E2416B
analysis probe. Logic analyzer software version requirements are
shown on the following page.
The HP E2416B requires four logic analyzer pods (68 channels) for
inverse assembly. The analysis probe contains one additional pod
that you can monitor.
Logic AnalyzersSupported
Logic Analyzer Channel
Count State
Speed Timing
Speed Memory
Depth
16600A 204 100 MHz 125 MHz 64 k states
16601A 136 100 MHz 125 MHz 64 k states
16602A 102 100 MHz 125 MHz 64 k states
16603A 68 100 MHz 125 MHz 64 k states
16550A (1 card) 102/card 100 MHz 250 MHz 4 k states
16554A (1 or 2 cards) 68/card 70 MHz 125 MHz 512 k states
16555A (1 or 2 cards) 68/card 110 MHz 250 MHz 1 M states
16555D (1 or 2 cards) 68/card 110 MHz 250 MHz 2 M states
16556A (1 or 2 cards) 68/card 100 MHz 200 MHz 1 M states
16556D (1 or 2 cards) 68/card 100 MHz 200 MHz 2 M states
1660A/AS/C/CS/CP 136 100MHz 250 MHz 4kstates
1661A/AS/C/CS/CP 102 100MHz 250 MHz 4kstates
1662A/AS/C/CS/CP 68 100 MHz 250 MHz 4 k states
1670A 136 70 MHz 125 MHz 64 k or .5 M states
1670D 136 100 MHz 125 MHz 64 k or 1 M states
1671A 102 70 MHz 125 MHz 64 k or.5 M
1671D 102 100 MHz 125 MHz 64 k or 1 M
1672A 68 70 MHz 125 MHz 64 k or.5 M
1672D 68 100 MHz 125 MHz 64 k or1 M
1-4 HP E2416B 80196 Analysis Probe

Logic analyzer software version requirements
The logic analyzers must have software with a version number greater than
or equal to those listed below to make a measurement with the HP E2416B.
You can obtain the latest software at the following web site:
www.hp.com/go/logicanalyzer
If your software version is older than those below, load new system software
with the listed version numbers or higher before loading the HP E2416B
software.
Logic Analyzer Software Version Requirements
Logic Analyzer Minimum Logic Analyzer Software Version for use with
HP E2416B
HP 16600 Series The latest HP 16600 logic analyzer software versionis on the
CD ROM shipped with this product.
HP 1660A/AS Series A.03.01
HP 1660C/CS/CP Series A.02.01
HP 1670A/D Series A.02.01
Mainframes*
HP 16700 Series The latest HP 16700 logic analyzer software versionis on the
CD ROM shipped with this product.
HP 16500C Mainframe A.01.05
HP 16500B Mainframe A.03.14
* The mainframesare usedwith the HP 16550 and HP 16554/55/56logicanalyzer modules.
Logic Analyzers Supported
Logic analyzer software version requirements
HP E2416B 80196 Analysis Probe 1-5

Equipment Used with the Analysis Probe
This section lists equipment used with the analysis probe. This
information is organized under the following titles: equipment
supplied, minimum equipment required, and additional equipment
supported
Equipment supplied
The equipment supplied with the analysis probe is shown in the illustration
on the next page. It is listed below:
•The analysis probe, which includes the analysis probe circuit card and
cables.
•One PGA-to-PLCC Adapter, HP part number 1200-1929.
•One PLCC-to-PGA Socket, HP part number 1200-1274.
•Two PGA extender sockets, HP part number 1200-1458.
•Logic analyzer configuration files and inverse assembler software on a
3.5-inch disk.
•Logic analyzer configuration files and inverse assembler software on a
CD ROM.
•This User’s Guide.
1-6 HP E2416B 80196 Analysis Probe

Equipment Supplied with the HP E2416B
Equipment Usedwith the Analysis Probe
Equipmentsupplied
HP E2416B 80196 Analysis Probe 1-7

Minimum equipment required
For state and timing analysis of an 80196 target system, you need all of the
following items.
•The HP E2416B Analysis Probe.
•The PGA-to-PLCC Adapter.
•The PLCC-to-PGA Socket.
•One of the logic analyzers listed on page 1-4. The logic analyzer software
version requirements are listed on page 1-5.
Additional equipment supported
The HP E2416B does not support any additional equipment.
EquipmentUsed with the Analysis Probe
Minimum equipment required
1-8 HP E2416B 80196 Analysis Probe

2
Connecting and Configuring
Your System

Connecting and Configuring Your System
This chapter shows you how to connect the logic analyzer to the
target system through the analysis probe.
If you are connecting to an HP 16600 or HP 16700 series logic
analysis system, follow the instructions given on screen in the Setup
Assistant for connecting and configuring your system. Use this
manual for additional information, if desired. Refer to chapter 1 for a
description of Setup Assistant.
If you are not using the Setup Assistant, follow the instructions given
in this chapter. This chapter is divided into the following sections;
the order shown here is the recommended order for performing these
tasks:
•Read the power on/power off sequence
•Connect the analysis probe to the target system
•Connect the analysis probe to the logic analyzer
•Configure the analysis probe
•Configure the logic analyzer
•Connect optional equipment
Configuring
Connecting &
Configuring
Your System
Chapter 2
Connecting
the Analysis
Probe to the
Target System
Analyzing the
Target System
Chapter 3
Connecting
Optional
Equipment
Overview
Chapter 1
Reference
Chapter 4
If You Have
a Problem
Chapter 5
Connecting
the Analysis
Probe to the
Logic Analyzer
2–2 HP E2416B 80196 Analysis Probe

Connection Sequence
HP E2416B 80196 Analysis Probe 2–3

Power-on/Power-off Sequence
Listed below are the sequences for powering on and off a fully
connected system. Simply stated, your target system is always the
last to be powered on, and the first to be powered off.
To power on HP 16600 and HP 16700 series logic
analysis systems
Ensure the target system is powered off.
1Turn on the logic analyzer. The Setup Assistant will guide you
through the process of connecting and configuring the analysis probe.
2When the analysis probe is connected to the target system and logic
analyzer, and everything is configured, turn on your target system.
To power on all other logic analyzers
With all components connected, power on your system in the following order:
1Logic analysis system.
2Your target system.
To power off
Turn off power to your system in the following order:
1Turn off your target system.
2Turn off your logic analysis system.
2–4 HP E2416B 80196 Analysis Probe
Table of contents
Other HP Computer Hardware manuals

HP
HP Xw4600 - Workstation - 2 GB RAM User manual

HP
HP E5000 User manual

HP
HP 81200 User manual

HP
HP 64793 Series User manual

HP
HP 10512 Installation instructions

HP
HP Nx9420 - Compaq Business Notebook Manual

HP
HP NC364T User manual

HP
HP 64782 User manual

HP
HP HP-UX 10.20 User manual

HP
HP MicroServe User manual

HP
HP P Class 450/500/550/600/650/700/750 Manual

HP
HP GbE2c - Blc Layer 2/3 Fiber SFP Option How to use

HP
HP UNDP-1H User manual

HP
HP Notebook Series User manual

HP
HP OmniBook 3100 User manual

HP
HP 381513-B21 - Smart Array P800 Controller... User manual

HP
HP 64746 User manual

HP
HP Nc6400 - Compaq Business Notebook User manual

HP
HP StorageWorks XP128 User manual

HP
HP A1250 Series Assembly instructions