HP ProCurve Switch 5400zl/3500yl Series
6
Operating temperature 32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F
(40°C) when used with any X2 10-GbE
32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F
(40°C) when used with any X2 10-GbE
32ºF to 131ºF (0ºC to 55ºC); 0°C to 40°C with
J8705A, J8706A, or J8707A modules installed
Operating relative humidity 15% to 95% @ 104ºF (40ºC), non-condensing 15% to 95% @ 104ºF (40ºC), non-condensing 15% to 95% @ 131ºF (55ºC), non-condensing
Non-operating/Storage temperature -40ºF to 158ºF (-40ºC to 70ºC) -40ºF to 158ºF (-40ºC to 70ºC) -40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/Storage relative humidity 15% to 90% @ 149ºF (65ºC), non-condensing 15% to 95% @ 149ºF (65ºC), non-condensing 15% to 95% @ 149ºF (65ºC), non-condensing
Altitude up to 15000 ft. (4.6 km) up to 15000 ft. (4.6 km) up to 10000 ft. (3 km)
Acoustic Power: 52.7 dB, Pressure: 44.8 dB ISO 7779,
ISO 9296
Power: 55.1 dB, Pressure: 45.3 dB ISO 7779,
ISO 9296
Power: 57 dB, Pressure: 40.2 dB ISO 7779,
ISO 9296
Electrical characteristics
Description The switch automatically adjusts to any
voltage between 100-127 and 200-240 volts
and either 50 or 60 Hz
The switch automatically adjusts to any
voltage between 100-127 and 200-240 volts
with either 50 or 60 Hz
Chassis ships without power supplies. Two
power-supply slots available; two different
power supplies available. See power-supply
products for additional specifications.
Maximum heat dissipation 670 BTU/hr (706 kJ/hr), (max non-PoE); 940
BTU/hr (991 kJ/hr) (max using PoE)
810 BTU/hr (854 kJ/hr), (max non-PoE);
1,090 BTU/hr (1149 kJ/hr) (max using PoE)
2450 BTU/hr (2584 kJ/hr), (max non-PoE);
3700 BTU/hr (3903 kJ/hr) (max using PoE)
Voltage 100-127 / 200-240 VAC 100-127 / 200-240 VAC 100-127 / 200-240 VAC
Current 10.0 / 5.0 A 10.0 / 5.0 A
Power consumption 723 W 759 W
Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Notes Maximum power rating is the worst-case
theoretical maximum power number with fully
loaded PoE, 100% traffic, all ports plugged in,
and all modules populated.
Maximum power draw if not using any PoE
power is 200 W (1.8 A @ 110 V, 0.9 A @ 220
V). Full load switch only heat spec listed
above subtracts heat dissipated in external
PoE powered devices. Heat dissipation does
not include heat dissipated by the PoE
powered devices themselves.
Maximum power rating is the worst-case
theoretical maximum power number with fully
loaded PoE, 100% traffic, all ports plugged in,
and all modules populated.
Maximum power draw if not using any PoE
power is 200 W (1.8 A @ 110 V, 0.9 A @ 220
V). Heat dissipation does not include heat
dissipated by the PoE powered devices
themselves.
Power supplies must be ordered separately.
One J8712A or J8713A can power the
J8697A chassis. Heat dissipation does not
include heat dissipated by the PoE powered
devices themselves.
Safety
CSA 22.2 No. 60950; UL 60950; IEC 60950;
EN 60950
CSA 22.2 No. 60950; UL 60950; IEC 60950;
EN 60950
CSA 22.2 No. 60950; UL 60950; IEC 60950;
EN 60950
Emissions
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
Immunity
EN EN 55024, CISPR 24 EN 55024, CISPR 24 EN 55024, CISPR 24
ESD IEC 61000-4-2; 4 kV CD, 8 kV AD IEC 61000-4-2; 4 kV CD, 8 kV AD IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated IEC 61000-4-3; 3 V/m IEC 61000-4-3; 3 V/m IEC 61000-4-3; 3 V/m
EFT/Burst IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
(signal line)
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
(signal line)
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
(signal line)
Surge IEC 61000-4-5; 1 kV/2 kV AC IEC 61000-4-5; 1 kV/2 kV AC IEC 61000-4-5; 1 kV/2 kV AC
Conducted IEC 61000-4-6; 3 V IEC 61000-4-6; 3 V IEC 61000-4-6; 3 V
Power frequency magnetic field IEC 61000-4-8; 1 A/m, 50 or 60 Hz IEC 61000-4-8; 1 A/m, 50 or 60 Hz IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions IEC 61000-4-11; >95% reduction, 0.5 period;
30% reduction, 25 periods
IEC 61000-4-11; >95% reduction, 0.5 period;
30% reduction, 25 periods
IEC 61000-4-11; >95% reduction, 0.5 period;
30% reduction, 25 periods
Harmonics EN 61000-3-2, IEC 61000-3-2 EN 61000-3-2, IEC 61000-3-2 EN 61000-3-2, IEC 61000-3-2