1Rating
Supply voltage: 230-240Vac
Frequency: 50Hz
Max Power Consumption: 375W
(May be connected to a light or power circuit if loading permits.)
2Please read carefully
Read through these instructions completely before commencing installation.
The HPM Single Lamp Instant Heat is designed for installation in the
ceilings of toilets and bathrooms where heat is required. The appliance
is fitted with a plug and lead for ease of installation. Two or more Instant
Heats may be required for larger bathrooms.
The infrared lamps heat by direct radiation rather than by heating the air in
the room, so the Instant Heat should be located directly over the drying area.
Instant Heat must not be installed where there is a possibility of water
splashing on to the lamps. Locate in accordance with the requirements of
the Australian/New Zealand Wiring Rules AS/NZS 3000 relating to damp
situations. This means that no part may be located directly above any part
of the bath or shower recess or enclosure. For unenclosed showers refer to
Wiring Rules conditions.
A minimum volume of 1m3is required around each Instant Heat to prevent
build-up of heat. Additional Instant Heats may be placed side-by-side if at
least 1m clearance between them is observed.
All wiring must be carried out by a licensed electrician.
3Location
The Instant Heat is for ceiling mounting
only, with the lowest point to be at least 2.2
metres above floor level. It is not intended to
be installed in wardrobes or within 300mm
of sides of walls, as per Figure 1. There is a
danger of combustion if placed too close to
curtains or other flammable materials.
4Ceiling preparation and installation
The clearances between Instant Heat and adjacent building members
shown in Figure 2 shall be observed. Thermal insulation or similar material
shall not be placed on top of the unit, and adjacent material to the side
shall be kept clear to a minimum distance of 150mm (Fig 3).
Joists, beams and rafters shall not be cut or notched to install Instant Heat.
After determining the location of Instant Heat use the template to mark out
and cut the aperture (Fig 4).
5Fixing to ceiling
Remove all packaging before installation.
Remove fascia and lamp. Check that
power to the circuit has been isolated
before connecting plug to mains supply.
Push the Instant Heat body into the
opening, ensuring the retractable clips do
not catch on the hole cutout. Once fully
recessed, push in the 3 clips and use a
screwdriver to tighten.
6Final assembly
Refasten the fascia cover which is designed to snap onto the housing flange
sitting flush against the ceiling. Insert the lamp into the socket, tightening
well to ensure good electrical contact and long life. Wipe the fascia and the
bulbs clean. Reconnect the power from the mains and test.
7Wiring
The Instant Heat may be dimmed for variable heat output. The recommended
dimmer is Excel Life Cat EM700TR.
Wall switches/controls should be located in a position that is not within reach
of a person in the bath or shower.
Instruction Sheet
Single Lamp Instant Heat
Cat. BH1WE / BH1MS
Joist
Joist
>150mm >150mm
Thermal
insulation
Thermal
insulation Thermal
insulation
Thermal
insulation
Fig 3
>100mm
clearance
2.2M Min.
Joist
>30mm
clearance
Fig 2
Fig 4
Instant
Heat
body
Fig 5
>300mm
Wall
>300mm
Fig 1

8Maintenance
Cleaning:
1. Isolate the Instant Heat from the 240V supply. Ensure the lamp is cool to
touch before handling.
2. Wipe lamps and fascia with care using a soft cloth soaked with a
neutral detergent.
Lamp Replacement:
1. Isolate the Instant Heat from the 240V supply. Ensure the lamp is cool to
touch before handling.
2. Replace heat lamp with HPM Cat No: L275HLES (275W) or
L375HLES (375W)
9Specifications
Supply voltage 230-240V ac 50Hz
Max power rating 375W
Ceiling cut-out: 175mm
Projection into ceiling: 200mm
Required ceiling depth >300mm
Fascia
Size: 210 x 210mm
Protrusion (excl. lamp): 20mm
Thermal overload protection: 100ºC
Cord length: 1500mm
Weight: (excl. packaging) 950g
10 Parts supplied
Instant Heat 1 piece
Infra-red heat lamp (275W) 1 piece
Ceiling cut-out template 1 piece
11 Warning
1. Use the Instant Heat only as described in this instruction. Other use not
recommended by HPM Legrand may cause fire or electric shock.
2. This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not
play with the appliance.
3. This product contains no serviceable parts and no attempt should
be made to repair this product. If the product is faulty it should be
discarded.
4. If the supply cord is damaged it must be replaced by HPM Legrand, it’s
service agent or a similarly qualified person in order to avoid a hazard.
5. This product must be cleaned periodically from dust and other
contaminants with a damp cloth. Cleaning agents and solvents should
never be used.
6. This product should not be enclosed in thermal insulation as it may
cause the unit to overheat.
7. This product is not suitable for installation in hazardous and/or
corrosive areas.
8. This product has been designed for domestic or similar uses and is not
suitable for a commercial installation.
9. This product utilises intellectual property in the form of registered
designs, trademarks, and/or patents. Such intellectual property
remains the property of HPM Legrand in all cases.
10. HPM Legrand reserves the right to modify the specification of this
product at any time.
12 Troubleshooting
This heater is fitted with a thermal cut-out to provide over-temperature
protection. If the lamp begins to switch ON/OFF intermittently during
operation this indicates that there may be a problem with the installation.
To rectify please check that distances from themal insulation and building
elements are being maintained. It may be necessary to replace the 375W
lamp with a 275W lamp (if not already fitted).
Warranty
HPM Legrand warrants the following on the Instant Heat from the date of purchase:
• 5-year warranty on materials and workmanship (excluding heat lamp).
• 2-year warranty on heat lamp.
These goods come with guarantees that cannot be excluded under the Australian and New
Zealand Consumer Laws. You are entitled to a replacement or a refund for a major failure
and for compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
See the Warranty card enclosed with this product for further details.
Customer Service
For all Customer Service and Technical Support
please call Monday to Friday during business hours.
HPM Legrand Australia
1300 369 777
www.hpm.com.au
HPM Legrand New Zealand
0800 476 00
www.hpm.co.nz
ABN: 31 000 102 661
LE06397AJB 08_2014
This manual suits for next models
1
Other HPM Heater manuals
Popular Heater manuals by other brands

Zibro
Zibro SRE 250 operating manual

CTC Union
CTC Union CLATRONIC HL 3800 instruction manual

flowair
flowair EliS A Technical documentation operation manual

Navien
Navien Comfort-Mate EQM301-SSUS quick start guide

Frico
Frico PA3210CA Original instructions

Dimplex
Dimplex DX 410EP Installation and operating instructions

Rowenta
Rowenta SPRINTO SO4010 Instructions for use

Mitsubishi Electric
Mitsubishi Electric CITY-MULTI PAC-PH01EHY-E installation manual

Bimar
Bimar BIS501 user manual

AEG
AEG WSP 2010 Operating and installation instructions

Sentiotec
Sentiotec Onni Mini user manual

Mytee
Mytee Hot Turbo 240-120 quick start guide