2
Product Information
• This product can only be used at PN 1MPa (10g/cm², 10 Bar, 145 PSI). It should only be filled with water/Glycol,
and at a temperature below 100 °C (212°F). See table below for installation requirements.
• If the temperature exceeds 48 ºC (or 120 ºF), please show a warning sign near the product to avoid
burning and scolding accidents.
•This Product is only suitable for use on indirect or sealed central heating systems including combination boilers.
To ensure that our products provide you with the service that we expect, it is important that they are installed to your local
code of practice for Central Heating for Domestic Premises
To ensure you can enjoy your radiator for as long as possible, it is essential you first FLUSH YOUR HEATING SYSTEM WITH
A CENTRAL HEATING CLEANSER, this will clear any waste from the system. Following the cleansing of the system you must
PROTECT THE SYSTEM WITH A CENTRAL HEATING INHIBITOR. These two simple steps will greatly increase the efficiency
and lifespan of your central heating system. Failure to complete these steps increases the chance of pinhole leaks, and will
also invalidate the guarantee on your radiator.
For further information on installing your radiator valves/electric element, please consult the instructions provided with them.
General Information
Do not throw away packaging until you have located and confirmed that you have all included parts. This
radiator must be installed by a qualified plumber or other fully competent person.
For your own protection we recommend that you wear safety boots and gloves.
Inspect the nish on the product for signs of damage before installation.
The provided xings are for solid brick walls only, if installing on any other surface please check that it will
safely support the product and purchase suitable xings.
Please read carefully...