Hussmann Chino Entyce TY3 Original operating instructions

/CHINO
TY3, TY4 (ENTYCE)
ISLAND CASE REV. 0221
Installation
& Operation
Manual
TY3, TY4
(ENTYCE)
ISLAND CASE
INSTALLATION & OPERATION GUIDE

2
Table of Contents
Warning 4
General Informaon 5
Cut and Plan Views 6
Installaon 8
Plumbing 10
Refrigeraon Piping 11
Sump Pump Conguraon 12
Specicaons 14
Electrical 22
Wiring Diagrams Index 22
Wiring Diagrams 23
User Informaon 39
Troubleshoong 40
Appendix 42

3
1. Do Not Push, Pull, Adjust, or Manipulate the TY case by any glass component.
• Doing so will result in severe damage to such components
• Glass breakage may result in serious injury
2. Never stand on the TY Top, Deck, or any Shelves for any reason.
• Misusing these surfaces as steps will result in damage to the case
• Misusing these surfaces as steps may result in serious injury to the user
•These surfaces are intended for the storage and merchandising of food products only
• Use a ladder or designed structure to work above the case (Do not lean on case)
3. DO NOT remove shelves. WARNING! will adversely impact case performance
when merchandising.
Not
Merchandising
Area

4
Minimum Clearances for TY cases are to be followed as instructed for proper placement inside store locations.
- A minimum clearance of 15’ from door opening must be maintained in order for case to remain in optimal performance.
- Side clearances are to be a minimum of 8’ when placed next to a solid wall.
- Height clearance measured from oor follows as a minimum of 10’ vertically.
- Minimum of 36” clearance if near an open aisle is required for optimal Air Curtain cycling.
(Assumed 8’ clearance from solid wall)
8’ CLEARANCE
8’ CLEARANCE
The folowing gure demonstrates
proper clearances for
Entyce cases assuming the
surrounding walls are solid to ensure
optimal performance of the cases Air
Curtain.
Warning

5
General Informaon
Case Descripon:
This Booklet specically covers the
following models:
Entyce - TY3
- TY4
Descripon: Entyce A mul deck air curtain Self-Service case designed to display pre-packaged Deli, Bakery,
Meat, Seafood, and/or Beverage products.
Shipping Damage: All equipment should be thoroughly examined for shipping damage before and during
unloading. This equipment has been carefully inspected at our factory and the carrier has assumed
responsibility for safe arrival. If damaged, either apparent or concealed, claim must be made to the carrier.
Apparent Loss or Damage: If there is an obvious loss or damage, it must be noted on the freight bill or express
receipt and signed by the carrier’s agent; otherwise, carrier may refuse claim. The carrier will supply necessary
claim forms.
Concealed Loss or Damage: When loss or damage is not apparent unl aer all equipment is uncrated, a claim
for concealed damage is made. Make request in wring to carrier for inspecon within 15 days, and retain all
packaging. The carrier will supply inspecon report and required claim forms.
Locaon/Store Condions: The refrigerated merchandisers have been designed for use only in air condioned
stores where temperature and humidity are maintained at 80°F and 55% relave humidity or 75°F and 55%
relave humidity. DO NOT allow air condioning, electric fans, ovens, open doors or windows (etc.) to create
air currents around the merchandiser, as this will impair its correct operaon.
Shortages: Check your shipment for any possible shortages of material. If a shortage should exist and is found
to be the responsibility of Hussmann Chino, nofy Hussmann Chino. If such a shortage involves the carrier,
nofy the carrier immediately, and request an inspecon. Hussmann Chino will acknowledge shortages within
ten days from receipt of equipment.
Hussmann Chino Product Control: The serial number and shipping date of all equipment has been recorded
in Hussmann’s les for warranty and replacement part purposes. All correspondence pertaining to warranty
or parts ordering must include the serial number of each piece of equipment involved, in order to provide the
customer with the correct parts.
Keep this booklet with the case at all mes for future reference.
This equipment is to be installed
to comply with the applicable
NEC, Federal, State , and Local
Plumbing and Construction
Code having jurisdiction.
AT TENTION
INSTALLER
/CHINO
A publication of HUSSMANN®Chino
13770 Ramona Avenue • Chino, California 91710
(909) 628-8942 FAX
(909) 590-4910
(800) 395-9229
Keep this booklet with the case at all times for future reference.

6
Cut and Plan Views
16 1/8(410)
221/2
(572)
10(254)
8(203)
403/8
(1026)
493/8
(1254)
5
(127)
TY3-4
TY3-4S
Self Contained
Option
243/8
(619)
20
(508)
233/8
(594)
571/2
(1461)
267/8
(683)
35
(889)
TY3-4
4' wide Merchandiser
22
1/2
(572)
471/2
(1206)
715/8
(1819)
121/8
(308)
243/8
(619)
12(305)
8(203)
571/
2
(1461)
27(686)
TY3-6 25
(635)
267/8
(683)
35
(889)
30
(762)
403/8
(1026)
493/8
(1254)
5
(127)
221/2
(572)
12(305)
8(203)
TY4-4
16 1/8(410)
10(254)
343/8
(873)
25
(635)
10
(254)
571/2
(1461)
167/8
(429)
20
(508)
TY4-4
4' wide Merchandiser
TY3-6
TY3-6
6' wide Merchandiser
221/2
(572)
471/2
(1206)
595/8
(1514)
121/8
(308)
243/8
(619)
8(203) 8(203)
571/2
(1461)
21(533) 21(533)
25
(635)
267/8
(683)
35
(889)
30
(762)
TY3-5 Entyce 3 level 5' wide island
12(305) 12(305)
22
1/2
(572)
471/2
(1206)
715/8
(1819)
121/8
(308)
343/8
(873)
12(305)
16(406)
8(203)
15
(381)
571/
2
(1461)
167/8
(429)
27(686)
20
(508)
TY4-6
221/2
(572)
471/2
(1206)
715/8
(1514)
61/8
(156)
343/8
(873)
12(305) 12(305)
16(406) 16(406)
8
(203)
8
(203)
15
(381)
571/2
(1461)
16 7/8
(429)
21(533) 21(533)
20
(508)
TY4-6
TY4-6
Entyce 4 level 6' wide island
TY4-6
TY4-6
6' wide Merchandiser

7
Refrig
Elec
Drain
Drain
11/2 (38)
12
3/8 (314)
12
3/8 (314)
11/2 (38) “A”
“B”
“A”
965/8
(2454) 21/8
(54)
485/8
(1235)
751/2
(1921)
835/8
(2124)
255/8
(651)
595/8
(1514)
493/8
(1254)
base panels
base rails
“B” 803/4
(2051)
231/2
(1867)
563/4
(1441)
TY-4
4' wide Flat End Merchandiser
C
L
“B”
“A”
End
Panels
Refrig
Elec
Drain
Drain
C
L
21/8
(54)
21/8 (54)
123/8
(314)
123/8
(314)
“A”
1211/2
(3086)
1451/2
(3696)
731/2
(1867)
971/2
(2477)
445/8
(1133)
consult
factory
consult
factory
255/8
(651)
351/2
(902)
“B”
“A”
“B”
491/2
(1257)
base panels
base rails
C
L
“A”
411/2
(1054)
231/2
(648)
325/8
(827)
“B”
TY-4
TY-4
4' wide Island Merchandiser
Junc
tion
C
ompartment
Elec
Drain
Drain
Refrig
C
L
C
L
155/8
(397)
715/
8
(1819)
73
(1854)
361/4
(921)
217/8
(556)
4
1/2 (114)
41/2 (114)
91/8
(234)
155/8
(397)
20
5/8
(524)
205/8
(524)
41/2
(114)
9
1/8
(234)
4
1/2
(114)
3
(76)
drains centered
to straight side
TY3-6X(case length) E - Flat End Merchandiser
Optional
End
Panel
11/8
(29)
84
(2164)
108
(2743)
60
(1524)
961/4 (2445) 1201/4 (3054) 1441/4 (3664)
Elec
Elec
Drain
Drain
Refrig
Refrig
C
L
C
L
155/8
(397)
715/8
(1819)
217/8
(556)
361/4
(921)
Drains centered
to straight side
361/4
(921)
217/8
(556)
4
1/2
(114) 91/8
(234)
41/2
(114)
155/8
(397)
205/8
(524)
205/8
(524)
4
1/2
(114)
91/8
(234)
41/2
(114)
24(610) 48(1219) 72(1829)
96(2438) 120(3048) 144(3658)
961/2(2452) 120 1/2(3061) 1441/2(3670) 1681/2(4280) 1921/2(4890) 2161/2(5499)
Junction
Compartment
TY3-6X
(case length)
I - Island Merchandiser

8
TY Lifting and Transport Instructions
1. The Entyce can be lifted by a forklift at typical
lifting points.
Lift Zones
Jack Points
J-Bar
Zones
Inser
t Forks
Underneath
Deck
WARNING
Improper placement of forks may damage
drainage piping. Use a spotter when placing
forks. Make sure that piping will not be dam-
aged. Use J-Bars or Jacks if forks cannot be
used safely
2. Ensure lower body panels are removed be-
fore lifting with a forklift. Serious damage will
occur if the body panels are not removed.
3. Make sure that fork spacing and width will not
damage drain or come in contact with piping,
or electrical lines
4. Be sure that the forks are long enough to
support beyond the center of the case but not
damage near components. Check for proper
balance before moving. A minimum fork
length of 36” is recommended for 68” wide
cases
Installation
5. The TY merchandiser can be raised at one
end underneath the deck with a forklift to al-
low the placement of rollers or dollies.
6. Evenly support the entire base structure on
rollers or dollies before attempting to move.
Each Base Leg must have its own dollie to
properly support the case.
Lifting Points are typical and dependent upon
size of case and refrigeration application, drain-
age congurations will call for altercations in
Lifting Zones.
Below are the following drainage congurations
and lifting should be altered to the expected
model.
Full Side Drain
Drain
Center Drain
Drain
Drain
Center Staggered Drain
Drain
Drain

9
Leveling
A LEVEL CASE IS NECESSARY TO INSURE PROPER
OPERATION AND WATER DRAINAGE. Note: A. To avoid
removing concrete ooring, begin lineup leveling from the highest
point of the store oor.
Installaon
Location
The refrigerated merchandisers have been designed for
use only in air conditioned stores where temperature and
humidity are maintained at or 75°F and 55% relative humidity
or below 80°F and 55% relative humidity. DO NOT allow air
conditioning, electric fans, ovens, open doors or windows
(etc.) to create air currents around the merchandiser, as this
will impair its correct operation.
Uncrating the Stand
Place the fixture as close to its permanent position as
possible. Detach the walls from each other and remove from
the skid. Unstrap the case from the skid. The xture can now
be lifted o the crate skid. Lift only at base of stand!
Exterior Loading
These models have not been structurally designed to support
excessive external loading. Do not walk on their tops;
This could cause serious personal injury and damage to
the xture.
It is the contractor’s responsibility to install
case(s) according to local construction and
health codes.

10
Plumbing
Waste Outlet and P-TRAP
The waste outlet is located in front and center of the case
on both sides which allows for suitable access to each drain
allowing drip piping to be run lengthwise under the xture. A
1-1/2” P-TRAP and threaded adapter are supplied with each
xture. The P-TRAP must be installed to prevent air leakage
and insect entrance into the xture.
NOTE: PVC-DWV solvent cement is recommended. Follow
Hussmann’s instrucons.
Installing Condensate Drain
Poorly or improperly installed condensate drains can
seriously restrict the operation of this refrigerator, and result
in costly maintenance and product losses. Please follow the
recommendations listed below when installing condensate
drains to insure a proper installation:
1. Never use pipe for condensate drains smaller than the
nominal diameter of the pipe or P-TRAP supplied with
the case.
2. When connecting condensate drains, the P-TRAP
must be used as part of the condensate drain to
prevent air leakage or insect entrance. Store
plumbing system oor drains should be at least 14” o
the center of the case to allow use of the P-TRAP pipe
section. Never use two water seals in series in any one
line. Double P-TRAPS in series will cause a lock and
prevent draining.
3. Always provide as much down hill slope (“fall”) as pos-
sible; 1/8” per foot is the preferred minimum. PVC pipe,
when used, must be supported to maintain the 1/8”
pitch and to prevent warping.
4. Avoid long runs of condensate drains. Long runs make
it impossible to provide the “fall” necessary for good
drainage.
5. Provide a suitable air break between the ood rim of
the oor drain and outlet of condensate drain. 1” is
ideal.
6. Prevent condensate drains from freezing:
a. Do not install condensate drains in contact with
non-insulated suction lines. Suction lines should
be insulated with a nonabsorbent insulation mate-
rial such as Armstrong’s Armaex.
b. Where condensate drains are located in dead air
spaces (between refrigerators or between a refrig-
erator and a wall), provide means to prevent freez-
ing. The water seal should be insulated to prevent
condensation.
Drain
Drain
Drain
Drain
Drain
One Sided Drain
Staggered Center Drain
Center Drain
Note: Cases are typical, length of cases
vary

11
Refrigeraon Piping
The standard refrigerant will be R-404 unless otherwise
specied on the customer order. Check the serial plate on
the case for information. Refrigeration outlet access and
the refrigeration components for the Entyce are situated on
the left hand side near the centerline of the case to deliver
optimal access which provides for easy installation and
maintenance purposes without the probability of damaging
any components.
Refrigeration Lines
Liquid Suction
3/8” O.D. 5/8” O.D.
Refrigerant lines should be sized as shown on the refrigeration
legend furnished by the store. Install P-TRAPS (oil traps) at
the base of all suction line vertical risers.
Pressure drop can
rob the system of capacity. To keep the pressure drop to a
minimum, keep refrigerant line run as short as possible, using
the minimum number of elbows. Where elbows are required,
use long radius elbows only. All refrigeration components are
located underneath the left hand side case deck pans.

12
Flex conduit from
elec. box to top
stub location.
This line will carry
-Main power and ground wires
-Sensor Wires
from the electrical box
to the top stub location.
Conduit inside the
refrigerated zone
must be liquid tight.
TY Top Mech
Housing Pipe
1H79952
Sump Pan
Drain spigots will
empty into the
sump pan
1H79925
Tub Brace
Sump Pump Outlet Piping
Connect to 3/8” drain linein housing
1H22638
(Diversitech CP-22)
Flex conduit from outlet
box to electrical box
This line will carry
power and ground
from the outlet box
the the electrical box.
Flex conduit line from
inside case to electrical box
T
his line will carry wiring from
-shelves/Canopy Harnesses
-Main Fan Harnesses
-Anti-Sweat Heaters
-Sensors
to the terminal block and
power supply in the elec. box.
1H79961
Electrical Box
Check Valve
CTQ
Sump Pump Conguraon
Connecng Sump Lines
For Entyce cases with a Sump Pump Conguration connect liquid line, suction line, electrical, and drain line to top case
stub-ups (outlets).
Note: Isolate Drain line from Suction line either by seperating the lines or insulating the suction line.
Liquid Line 1/2” 85 fpm
Suction Line 7/8” 1234 fpm

13
Installers:Afterrunning electrical you
MUST sealtop (shown here)and bottom
of this pipe to eliminateany air
penetration!
Failuretodosowillcause condensation
inside of pipe andwater will drip on
floor!
Silicone is an acceptablematerialto
sealpipe.
Sealed refrigeration lines inside of
pipe.
This is an EXAMPLEofhow to
properly seal electrical lines(using
silicone)onceelectricallines are
pulledusing provided wire-chase.
Sealing Sump Lines
For Entyce cases with a Sump Pump Conguration connect liquid line, suction line, electrical, and drain line to top case
stub-ups (outlets).
Note: Example below demonstrates the proper method of sealing refrigeration and electrical access points. En
sure tight seal to eliminate any air penetration.

14
Specicaons
SELF-SERVICE DELI REVISION DATE 02/06/17
HUSSMANN - TY1-6 I-ISLAND (CHINO)
REFRIGERATION DATA:
8'-I 1.1 3.4 4.6
8'-I 9600 9600 24 24 12'-I 1.8 5.0 4.4
12'-I 14400 14400 24 24
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) BTUS DO NOT INCLUDE LIGHTS.
2) ADD 10 BTU'S PER FOOT OF LED SHELF LIGHTS PER LIGHT MATRIX BELOW.
3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY.
4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH.
REFRIGERATION DATA CONTINUED:
1 1.125
DELI 32 29 OFF TIME 16 48 TBD
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
8'-I 68 10 1.8 48 0.12 14 N/A N/A 0.12 14 0.43 50 1115 15
12'-I 10 8 10 3 80 0.30 35 N/A N/A 0.30 35 0.78 90 1 115 15
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CASE ENERGY USAGE DATA:
AMPS WATTS AMPS WATTS AMPS WATTS
8'-I N/A N/A N/A N/A N/A N/A
12'-I N/A N/A N/A N/A N/A N/A
6
14
LIGHT
MATRIX
FT OF
LEDS
CASE LENGTHS CASE USAGE
CAPACITY ***
(BTU/HR) TOTAL TEMPERATURE (ºF) VELOCITY
(FT/MIN)
GLYCOL (20°F
INLET, 6° RISE)
RATING CONDITION EVAPORATOR
DISCHARGE
AIR ** (°F)
GPM PSI
NSF 7
EST.
REFG.
CHRG.
404A
(LBS)
DELI
30~32
150~200
DELI
30~32
150~200
AHRI
1200
NSF 7
CASE
LENGTHS
AHRI
1200
NSF 7 NSF 7
END PANEL WIDTH KEY
# OF END
PNLS
END PNL
WIDTH
(IN.)
TOTAL ADDED
LENGTH (IN.)
1.125
DRIP
TIME
DEFROST
WATER
(LBS/DAY/FT)
USAGE CUT IN
(ºF)
CUT
OUT
(ºF)
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
DEFROST
TYPE
TIME
(MIN)
DEFROST
FREQUENCY
(#/DAY)
TERM.
TEMP
(°F) COIL
ONLY
12
9.5
AMPS WATTS AMPS WATTS
EVAPORATOR FANS CANOPY LIGHTS
LED
OPTIONAL LED
SHELF LIGHTS
# OF
EVAP
FANS
BLADE
DIA.
(IN.)
BLADE
PITCH (°) AMPS WATTS
MAX. LED LOAD
(W/ ALL OPTIONS)
AMPS
CASE LENGTH
CANOPY
LIGHTS
H.O. LED
OPTIONAL SHELF MAX. H.O. LED
LOAD
CASE LENGTH TDA/V (ft2/ft) ACTUAL CDEC
(KWh/day/ft)
CASE LENGTH
MAX ALLOWABLE
CDEC (KWh/Day/ft)
WATTS AMPS WATTS #
OUTLETS VOLTS
CONVENIENCE
OUTLETS (OPTIONAL)
ANTI-SWEAT
HEATERS (ON
FAN CIRCUIT)
AMPS
8'-I
0
0.53
0.27
12'-I
0
0.00
3.18

15
SELF SERVICE MULTI-DECK HOT CASE
HUSSMANN - TY3-4X
ELECTRICAL DATA:
208 3 60 2 5128 14.4 14.4 13.9 5
208 3 60 2 4563 13.7 13.7 10.6 5
208 3 60 2 5764 17.5 17.5 13.0 5
N/A -
TBD -
SBO -
1 2.125 2.125
2 1.125 2.25
240 3 60 2 6069 15.8 15.8 12.2 5
240 3 60 2 7809 20.2 20.2 15.0 5
* INCLUDES INCANDESCENT LAMPS
OPTIONS/NOTES:
1) NOTE: CASE WIDTH INCLUDES END PANELS WITH OPTIONAL INTERIOR END PANELS
2) NOTE: CASES MUST BE GROUNDED
3) NOTE: LED LIGHTS ARE NOT AVAILABLE ON HOT CASES AT THIS TIME.
WIRES
**
WIRES
**
208 VOLT
MODELS
240 VOLT
MODELS
AMPS
L3
*** TOTAL HEATED LEVELS = # ROWS OF SHELVES + BOTTOM WARMING SURFACE
AMPS
L3
VOLTS
AMPS
L1
AMPS
L2
VOLTS PH HZ
TOTAL
HOT
LEVELS
***
WATTS *
PH HZ
TY3-4X4C-H
TY3-4X4E-H
AMPS
L2
TOTAL
HOT
LEVELS
***
AMPS
L1
TY3-4X5E-H
** INCLUDES GROUND WIRE
WATTS *
NOT AVAILABLE
TO BE DETERMINED
SUPPLIED BY OTHERS
# OF END
PNLS
END
PNL
WIDTH
(IN.)
LEGEND
EXTERNAL END PANEL WIDTH KEY
TOTAL
ADDED
LENGTH
(IN.)
TY3-4X4E-H
TY3-4X5E-H
SELF-SERVICE HOT CASE 122614

16
SELF-SERVICE DELI REVISION DATE 02/06/17
HUSSMANN - TY3-4 I-ISLAND, E-END, REMOTE (CHINO)
REFRIGERATION DATA:
6I 1.1 2.8 3.6
6I 9150 7800 26 28 8I 1.1 3.7 5.0
8I 12200 10400 26 28 10I 1.3 4.5 3.5
10I 15250 13000 26 28 12I 1.8 5.4 4.7
12I 18300 15600 26 28 4E 0.8 3.5 4.2
4E 6100 5200 26 28 6E 1.1 4.3 6.2
6E 9200 7800 26 28 8E 1.3 5.1 4.2
8E 12300 10400 26 28
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) BTUS DO NOT INCLUDE LIGHTS.
2) ADD 10 BTU'S PER FOOT OF LED SHELF LIGHTS PER LIGHT MATRIX BELOW.
3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY.
4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH.
REFRIGERATION DATA CONTINUED:
DELI 33 30 OFF TIME 16 48 N/A 1 1.125
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
6I 68 15 1.8 48 0.12 14 0.25 29 0.37 43 0.61 70 1 115 15
8I 6 8 15 1.8 48 0.22 25 0.44 50 0.65 75 0.78 90 1 115 15
10I 8 8 15 2.4 64 0.30 35 0.61 70 0.91 105 0.78 90 1 115 15
12I 10 8 10 3.0 80 0.40 46 0.79 91 1.19 137 0.96 110 1 115 15
4E 4 8 15 1.2 32 0.10 12 0.21 24 0.31 36 0.26 30 1 115 15
6E 6 8 15 1.8 48 0.20 23 0.40 46 0.60 68 0.61 70 1 115 15
8E 8 8 15 2.4 64 0.28 33 0.57 65 0.85 98 0.78 90 1 115 15
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CASE ENERGY USAGE DATA:
AMPS WATTS AMPS WATTS AMPS WATTS
6I N/A N/A N/A N/A N/A N/A
8I N/A N/A N/A N/A N/A N/A
10I N/A N/A N/A N/A N/A N/A
12I N/A N/A N/A N/A N/A N/A
4E N/A N/A N/A N/A N/A N/A
6E N/A N/A N/A N/A N/A N/A
8E N/A N/A N/A N/A N/A N/A
90° OS 0 0.00 0.00
22.5° OS
0
0.00
0.00
45° OS
0
0.00
0.00
3',4',5',6',8',10',12'
0
0.00
4.48
22.5° IS
0
0.00
0.00
45° IS
0.00
0.00
0.00
CASE LENGTH
CANOPY
LIGHTS
H.O. LED
OPTIONAL SHELF MAX. H.O. LED
LOAD
CASE LENGTH /
WEDGES
TDA/V (ft
2
/ft)
(ft
3
wedges)
ACTUAL CDEC
(KWh/day/ft)
(KWh/day wedges)
CASE LENGTH
MAX ALLOWABLE
CDEC (KWh/Day/ft)
(KWh/day wedges)
CONVENIENCE
OUTLETS (OPTIONAL)
# OF
EVAP
FANS
BLADE
DIA.
(IN.)
BLADE
PITCH (°) AMPS WATTS AMPS WATTS AMPS WATTS
EVAPORATOR FANS
CANOPY LIGHTS
LED
OPTIONAL LED
SHELF LIGHTS
MAX. LED LOAD
(W/ ALL OPTIONS)
ANTI-SWEAT
HEATERS (ON
FAN CIRCUIT)
AMPS WATTS AMPS WATTS
#
OUTLETS
VOLTS AMPS
DEFROST
WATER
(LBS/DAY/FT)
USAGE
CUT IN
(ºF)
CUT
OUT
(ºF)
12
15
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
DEFROST
TYPE
TIME
(MIN)
DEFROST
FREQUENCY
(#/DAY)
TERM.
TEMP
(°F)
COIL
ONLY
DRIP
TIME
END PANEL WIDTH KEY
# OF END
PNLS
END PNL
WIDTH
(IN.)
TOTAL ADDED
LENGTH (IN.)
1.125
DELI
31~33
100~175
DELI
31~33
100~175
DELI 31~33 100~175
DELI
31~33
100~175
DELI
31~33
100~175
DELI
31~33
100~175
DELI
31~33
100~175
EST.
REFG.
CHRG.
(LBS)
20°F GLYCOL
6° RISE
RATING
CONDITION
EVAPORATOR
DISCHARGE
AIR ** (°F)
GPM PSI
NSF 7
AHRI
1200
NSF 7
CASE LENGTHS CASE USAGE
CAPACITY ***
(BTU/HR)
TEMPERATURE (ºF) VELOCITY
(FT/MIN)
CASE
LENGTHS
AHRI
1200
NSF 7 NSF 7
LIGHT
MATRIX
FT OF
LEDS
18'
30'
42'
54'
15'
27'
39'

17
SELF-SERVICE DELI CHEESE REVISION DATE 03/21/17
HUSSMANN - TY3-5 I-ISLAND (CHINO)
REFRIGERATION DATA:
7I 1.1 3.8 5.2
7I 10770 10770 26 26 9I 1.3 4.8 3.8
9I 13790 13790 26 26 11I 1.8 5.8 5.1
11I 16810 16810 26 26 13I 2.2 6.7 6.7
13I 19830 19830 26 26 15I 2.7 7.6 4.7
15I 22850 22850 26 26 17I 3.1 8.5 5.4
17I 25870 25870 26 26
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) BTUS ARE SHOWN WITHOUT LIGHTS
2) ADD 10 BTU/FT OF LED LIGHTS PER LIGHT MATRIX BELOW
3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
REFRIGERATION DATA CONTINUED:
11.125
DELI / CHEESE 33 30 OFF TIME 16 48 N/A 21.125
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
7I 6815 1.8 48 0.12 14.27 0.29 32.99 0.41 47 0.43 50 1115 15
9I 8815 2.4 64 0.22 25.04 0.47 54.52 0.69 80 0.61 70 1115 15
11I 10 815 3.0 80 0.30 34.87 0.65 74.18 0.95 109 0.78 90 1115 15
13I 12 810 3.6 96 0.40 45.63 0.83 95.71 1.23 141 0.96 110 1115 15
15I 14 810 4.2 112 0.49 56.39 1.02 117.23 1.51 174 1.04 120 1115 15
17I 16 810 4.8 128 0.57 65.29 1.17 135.02 1.74 200 1.22 140 1115 15
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CASE ENERGY USAGE DATA:
AMPS WATTS AMPS WATTS AMPS WATTS
7I N/A N/A N/A N/A N/A N/A
9I N/A N/A N/A N/A N/A N/A
11I N/A N/A N/A N/A N/A N/A
13I N/A N/A N/A N/A N/A N/A
15I N/A N/A N/A N/A N/A N/A
17I N/A N/A N/A N/A N/A N/A
90° OS
0
0.00
0.00
22.5° OS
0
0.00
0.00
45° OS
0
0.00
0.00
3',4',5',6',8',10',12'
#DIV/0!
0.00
4.70
22.5° IS
0.00
0.00
0.00
45° IS
0
0.00
0.00
CASE LENGTH
CANOPY
LIGHTS
H.O. LED
OPTIONAL SHELF
MAX. H.O. LED
LOAD
CASE LENGTH /
WEDGES
TDA/V (ft
2
/ft)
(ft
3
wedges)
ACTUAL CDEC
(KWh/day/ft)
(KWh/day wedges)
CASE LENGTH
MAX ALLOWABLE
CDEC (KWh/Day/ft)
(KWh/day wedges)
CONVENIENCE
OUTLETS (OPTIONAL)
# OF
EVAP
FANS
BLADE
DIA. (IN.)
BLADE
PITCH (°)
AMPS
WATTS
AMPS
WATTS
AMPS
WATTS
EVAPORATOR FANS
CANOPY LIGHTS
LED
OPTIONAL LED
SHELF LIGHTS
MAX. LED LOAD
(W/ ALL OPTIONS)
ANTI-SWEAT
HEATERS (ON
FAN CIRCUIT)
AMPS
WATTS
AMPS
WATTS
#
OUTLETS
VOLTS
AMPS
DEFROST
WATER
(LBS/DAY/FT)
USAGE
CUT IN
(ºF)
CUT
OUT
(ºF)
12
11
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
DEFROST
TYPE
TIME
(MIN)
DEFROST
FREQUENCY
(#/DAY)
TERM.
TEMP
(°F) COIL
ONLY
DRIP
TIME
END PANEL WIDTH KEY
# OF END
PNLS
END PNL
WIDTH
(IN.)
TOTAL ADDED
LENGTH (IN.)
1.125
2.25
DELI / CHEESE
30~33
175~250
DELI / CHEESE
30~33
175~250
NSF 7
AHRI
1200
NSF 7
DELI / CHEESE
30~33
175~250
DELI / CHEESE
30~33
175~250
DELI / CHEESE
30~33
175~250
DELI / CHEESE
30~33
175~250
82
LIGHT
MATRIX
FEET
22
34
46
58
70
CASE LENGTHS
CASE USAGE
CAPACITY ***
(BTU/HR)
TEMPERATURE (ºF)
VELOCITY
(FT/MIN)
CASE
LENGTHS
AHRI
1200
NSF 7
NSF 7
EST.
REFG.
CHRG.
(LBS)
20°F GLYCOL
6° RISE
RATING CONDITION
EVAPORATOR
DISCHARGE
AIR ** (°F)
GPM
PSI

18
SELF-SERVICE DELI / PRODUCE REVISION DATE 06/07/18
HUSSMANN - TY3-6 I-ISLAND, E-END, C-CENTER (CHINO)
REFRIGERATION DATA:
8I 1.1 4.7 6.6
8I, 10I, 12I, 14I,
16I, 18I 1650 1340 20 28 10I 1.3 5.8 4.6
8I, 10I, 12I, 14I,
16I, 18I N/A 1340 N/A 28 12I 1.8 6.9 6.2
8E, 10E, 12E 1570 1340 20 28 14I 2.2 7.9 7.9
16I 2.7 8.9 5.5
*APPROVED FOR NON-CRITICAL TEMP PRODUCE ONLY 18I 3.1 9.9 6.3
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB 8E 1.3 4.1 3.3
***REFRIGERATION NOTES: 10E 1.8 5.0 4.6
1) BTU'S ARE SHOWN WITHOUT LIGHTS. 12E 2.2 6.0 6.1
2) ADD 10 BTU'S PER FOOT OF LED LIGHTS PER LIGHT MATRIX BELOW.
3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY.
4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH.
REFRIGERATION DATA CONTINUED:
DELI 30 26 OFF TIME 16 52 N/A 1 1.125
PRODUCE 38 34 OFF TIME 16 52 N/A 2 1.125
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
8I
6 8 15 1.8 48 0.1 14 0.3 37 0.4 52 0.4 50 1 115 15 22
10I 8 8 15 2.4 64 0.2 25 0.5 59 0.7 84 0.6 70 1 115 15 36
12I 10 8 15 3.0 80 0.3 35 0.7 79 1.0 113 0.8 90 1 115 15 46
14I 12 8 10 3.6 216 0.4 46 0.9 100 1.3 146 1.0 110 1 115 15 58
16I 14 8 10 4.2 252 0.5 56 1.1 122 1.5 178 1.0 120 1 115 15 70
18I 16 8 10 4.8 288 0.6 65 1.2 139 1.8 205 1.2 140 1 115 15 82
8E 6 8 15 1.8 48 0.2 28 0.5 56 0.7 85 0.3 40 1 115 15 33
10E 8 8 15 2.4 64 0.3 38 0.7 77 1.0 115 0.3 40 1 115 15 45
12E 10 8 15 3.0 80 0.3 33 0.8 98 1.1 130 1.0 110 1 115 15 57
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CASE ENERGY USAGE DATA:
AMPS WATTS AMPS WATTS AMPS WATTS
8I N/A N/A N/A N/A N/A N/A
10I N/A N/A N/A N/A N/A N/A
12I N/A N/A N/A N/A N/A N/A
14I N/A N/A N/A N/A N/A N/A
16I N/A N/A N/A N/A N/A N/A
18I N/A N/A N/A N/A N/A N/A
8E N/A N/A N/A N/A N/A N/A
10E N/A N/A N/A N/A N/A N/A
12E N/A N/A N/A N/A N/A N/A
LIGHT
MATRIX
FT OF
LEDS
90° OS 0 0.00 0.00
22.5° OS
0
0.00
86.36
45° OS
0
0.00
96.02
3',4',5',6',8',10',12'
0
0.00
5.59
22.5° IS
0
0.00
76.70
45° IS
0
0.00
0.00
CASE LENGTH
CANOPY LIGHTS
H.O. LED OPTIONAL SHELF MAX. H.O. LED
LOAD
CASE LENGTH /
WEDGES
TDA/V (ft
2
/ft)
(ft
3
wedges)
ACTUAL CDEC
(KWh/day/ft)
(KWh/day wedges)
CASE LENGTH
MAX ALLOWABLE
CDEC (KWh/Day/ft)
(KWh/day wedges)
CONVENIENCE OUTLETS
(OPTIONAL)
# OF
EVAP
FANS
BLADE
DIA. (IN.)
BLADE
PITCH (°) AMPS WATTS AMPS WATTS AMPS WATTS
EVAPORATOR FANS CANOPY LIGHTS
LED
OPTIONAL LED
SHELF LIGHTS
MAX. LED LOAD
(W/ ALL OPTIONS)
ANTI-SWEAT
HEATERS (ON
FAN CIRCUIT)
AMPS WATTS AMPS WATTS
#
OUTLETS
VOLTS AMPS
12 15.8
ELEC. THERMOSTAT / AIR SENSOR
SETTINGS
DEFROST
TYPE
TIME
(MIN)
DEFROST
FREQUENCY
(#/DAY)
TERM.
TEMP
(°F) COIL
ONLY
DRIP
TIME
15.8 1.125
2.25
CASE
LENGTHS
AHRI
1200
NSF 7 NSF 7
EST.
REFG.
CHRG.
404a
(LBS)
GLYCOL (20°F
INLET, 6° RISE
RATING CONDITION EVAPORATOR DISCHARGE AIR
** (°F) GPM PSI
NSF 7
AHRI
1200
NSF 7
12
DELI 28~30 100~150
DELI 28~30
CASE LENGTHS CASE USAGE
CAPACITY ***
(BTU/HR/FT)
TEMPERATURE (ºF) VELOCITY
(FT/MIN)
END PANEL WIDTH KEY
# OF END
PNLS
END PNL
WIDTH (IN.)
TOTAL ADDED
LENGTH (IN.)
100~150
PRODUCE* N/A 100~150
DEFROST
WATER
(LBS/DAY/FT)
USAGE
CUT IN
(ºF)
CUT OUT
(ºF)

19
SELF-SERVICE DELI TYPE I REVISION DATE 08/26/19
HUSSMANN - TY4-4 I-ISLAND, E-END (CHINO)
REFRIGERATION DATA:
6I 2.5 4.1 5.6
6I,8I,10I,12I 1910 1910 26 26 8I 2.5 5.4 7.8
4E,6E,8E,10E 1850 1850 26 26 10I 3.0 6.7 5.4
12I 3.4 7.9 7.2
4E 2.0 2.5 2.8
6E 2.5 2.5 3.3
8E 3.0 3.7 2.9
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB 10E 3.4 4.7 4.4
***REFRIGERATION NOTES:
1) BTU'S SHOWN ARE WITHOUT LIGHTS
2) ADD 10 BTU'S PER FOOT OF LED LIGHTS PER LIGHT MATRIX BELOW
3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
REFRIGERATION DATA CONTINUED:
1 1.125
DELI 32 29 OFF TIME 16 54 N/A
2 1.125
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
6I
6 8 15 1.8 48 0.1 14 0.4 52 0.6 66 0.4 50 1 115 15
8I 68 20 1.8 48 0.2 25 0.7 84 0.9 109 0.6 70 1 115 15
10I 88 15 2.4 64 0.3 35 1.0 113 1.3 148 0.8 90 1 115 15
12I 10 8 15 3.0 80 0.4 46 1.3 146 1.7 191 1.0 110 1115 15
4E 48 20 1.2 32 0.1 12 0.4 41 0.5 53 0.3 40 1115 15
6E 68 15, 20 1.8 48 0.2 23 0.6 73 0.8 96 0.5 60 1 115 15
8E 88 20 2.4 48 0.3 33 0.9 102 1.2 135 0.7 80 1 115 15
10E 10 8 15, 20 3.0 64 0.4 43 1.2 135 1.5 178 0.9 100 1115 15
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
AMPS WATTS AMPS WATTS AMPS WATTS
6I N/A N/A N/A N/A N/A N/A
8I N/A N/A N/A N/A N/A N/A
10I N/A N/A N/A N/A N/A N/A
12I N/A N/A N/A N/A N/A N/A
4E N/A N/A N/A N/A N/A N/A
6E N/A N/A N/A N/A N/A N/A
8E N/A N/A N/A N/A N/A N/A
10E N/A N/A N/A N/A N/A N/A
LIGHT
MATRIX
FT OF LED
26
42
58
74
22
38
54
70
CONVENIENCE
OUTLETS (OPTIONAL)
#
OUTLETS
VOLTS AMPS
CASE LENGTHS CASE USAGE
CAPACITY ***
(BTU/HR/FT)
TEMPERATURE (ºF) VELOCITY
(FT/MIN)
DELI
30~32
100~150
CASE
LENGTHS
AHRI
1200
NSF 7 NSF 7
EST.
REFG.
CHRG.
(LBS)
20°F GLYCOL
6° RISE
RATING
CONDITION
EVAPORATOR
DISCHARGE
AIR ** (°F)
GPM PSI
NSF 7
AHRI
1200
NSF 7
END PANEL WIDTH KEY
# OF END
PNLS
END PNL
WIDTH
(IN.)
TOTAL ADDED
LENGTH (IN.)
1.125
2.25
DELI
30~32
100~150
WATTS AMPS WATTS
DEFROST
WATER
(LBS/DAY/FT)
USAGE
CUT IN
(ºF)
CUT
OUT
(ºF)
12 12
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
DEFROST
TYPE
TIME
(MIN)
DEFROST
FREQUENCY
(#/DAY)
TERM.
TEMP
(°F)
COIL
ONLY
DRIP
TIME
CASE LENGTH
CANOPY
LIGHTS
H.O. LED
OPTIONAL SHELF MAX. H.O. LED
LOAD
CASE LENGTH
EVAPORATOR FANS
CANOPY LIGHTS
LED
OPTIONAL LED
SHELF LIGHTS
MAX. LED LOAD
(W/ ALL OPTIONS)
ANTI-SWEAT
HEATERS
AMPS WATTS AMPS WATTS
# OF
EVAP
FANS
BLADE
DIA.
(IN.)
BLADE
PITCH (°) AMPS WATTS AMPS

20
SELF-SERVICE DELI CHEESE REVISION DATE
HUSSMANN - TY4-5 I-ISLAND (CHINO)
REFRIGERATION DATA:
7I 1.1 4.8 6.8
7I
13660
13660
22
22
9I
1.3
6.2
4.9
9I
17500
17500
22
22
11I
1.8
7.4
6.7
11I
21340
21340
22
22
13I
2.2
8.7
8.7
13I
25180
25180
22
22
15I
2.7
9.8
6.1
15I
29000
29000
22
22
17I
3.1
11.0
7.0
17I
32850
32850
22
22
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) BTU'S SHOWN ARE WITHOUT LIGHTS.
2) ADD 10 BTU'S PER FOOT OF LED LIGHTS PER LIGHT MATRIX BELOW.
3) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY.
4) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
5) RATING CONDITION IS NSF TYPE I, 75°F/55% RH.
REFRIGERATION DATA CONTINUED:
1 1.125
DELI / CHEESE
31
28
OFF TIME
16
52
N/A
2
1.125
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
7I
6
8
20
1.8
48
0.12
14
0.57
66
0.70
80
0.43
50
1
115
15
9I
8
8
20
2.4
64
0.22
25
0.85
98
1.07
123
0.61
70
1
115
15
11I
10
8
20
3
80
0.30
35
1.11
128
1.41
162
0.78
90
1
115
15
13I
12
8
15
3.6
96
0.40
46
1.39
160
1.79
205
0.96
110
1
115
15
15I
14
8
15
4.2
112
0.49
56
1.67
192
2.16
249
1.04
120
1
115
15
17I
16
8
15
4.8
128
0.57
65
1.90
219
2.47
284
1.22
140
1
115
15
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CASE ENERGY USAGE DATA:
AMPS WATTS AMPS WATTS AMPS WATTS
7I
N/A
N/A
N/A
N/A
N/A
N/A
9I
N/A
N/A
N/A
N/A
N/A
N/A
11I
N/A
N/A
N/A
N/A
N/A
N/A
13I
N/A
N/A
N/A
N/A
N/A
N/A
15I
N/A
N/A
N/A
N/A
N/A
N/A
17I N/A N/A N/A N/A N/A N/A
6/20/2018
CASE LENGTHS CASE USAGE
CAPACITY ***
(BTU/HR)
TEMPERATURE (ºF) VELOCITY
(FT/MIN)
CASE
LENGTHS
AHRI
1200
NSF 7 NSF 7
EST.
REFG.
CHRG.
404A
(LBS)
GLYCOL (20°F
INLET, 6° RISE)
RATING
CONDITION
EVAPORATOR
DISCHARGE
AIR ** (°F)
GPM PSI
NSF 7
AHRI
1200
NSF 7
DELI /
28~30
100~150
DELI /
28~30
100~150
DELI /
28~30
100~150
DELI /
28~30
100~150
END PANEL WIDTH KEY
# OF END
PNLS
END PNL
WIDTH
(IN.)
TOTAL ADDED
LENGTH (IN.)
1.125
2.25
DELI /
28~30
100~150
DELI /
28~30
100~150
WATTS AMPS WATTS
DEFROST
WATER
(LBS/DAY/FT)
USAGE
CUT IN
(ºF)
CUT
OUT
(ºF)
12
12
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS DEFROST
TYPE
TIME
(MIN)
DEFROST
FREQUENCY
(#/DAY)
TERM.
TEMP
(°F)
COIL
ONLY
DRIP
TIME
CASE LENGTH
CANOPY
LIGHTS
H.O. LED
OPTIONAL SHELF MAX. H.O. LED
LOAD
CASE LENGTH /
WEDGES
TDA/V (ft
2
/ft)
(ft
3
wedges)
ACTUAL CDEC
(KWh/day/ft)
(KWh/day wedges)
CONVENIENCE
OUTLETS (OPTIONAL)
# OF
EVAP
FANS
BLADE
DIA.
(IN.)
BLADE
PITCH (°) AMPS WATTS AMPS WATTS AMPS WATTS
CASE LENGTH
EVAPORATOR FANS
CANOPY LIGHTS
LED
OPTIONAL LED
SHELF LIGHTS
MAX. LED LOAD
(W/ ALL OPTIONS)
ANTI-SWEAT
HEATERS (ON
FAN CIRCUIT)
AMPS
17I 0 0.00 3.18
11I
0
0.00
3.18
13I
0
0.00
3.18
34
50
66
82
98
114
LIGHT
MATRIX
FT OF LED
15I
0
0.00
3.18
MAX ALLOWABLE
CDEC (KWh/Day/ft)
(KWh/day wedges)
7I
0
0.53
0.27
9I
0
0.00
3.18
#
OUTLETS
VOLTS AMPS
Other manuals for Entyce TY3
1
This manual suits for next models
7
Table of contents
Popular Display Case manuals by other brands

Bartscher
Bartscher Deli Compact instruction manual

Nordcap
Nordcap Oasi 4 M manual

Hatco
Hatco FLAV-R-FResh FDWD-12-2X Installation and operating manual

Royal-Kincool
Royal-Kincool Anvil NDSJ2730 instruction manual

Displays2go
Displays2go SMSAL39 Assembly instructions

Delfield
Delfield F15MR48N Specification sheet

Hoshizaki
Hoshizaki RNC-120A-LA Service manual

True
True TDBD-72-2 Specifications

Hatco
Hatco FLAV-R-SAVOR WFST-1X Installation & operating manual

Woodson
Woodson W.HFS Series Specification, installation and operation manual

Nordcap
Nordcap COOL-LINE Delizie M quick start guide

Delfield
Delfield 724 Specification sheet