M1X-XGEC Technical Data Sheet2 of 5 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as in. and (mm).
Meat, Delicatessen and Produce
09-2005
M1X
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length (without ends or partitions) 48 3/8(1229) 72 3/8(1838) 96 3/8(2448) 144 1/2(3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper) 42 (1064) 42 (1064) 42 (1064) 42 (1064)
Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) 33 1/2 (851) 33 1/2 (851)
Back of case to O/S edge of front leg 30 1/4 (768) 30 1/4 (768) 30 1/4 (768) 30 1/4 (768)
Distance between edges of external legs and center legs NA 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054)
Distance between edges of center legs NA NA NA 43 7/8 (1114)
Distance between front legs and splashguard 2 3/4(70) 2 3/4(70) 2 3/4(70) 2 3/4(70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
Back of case to center of stub up area 24 (612) 24 (612) 24 (612) 24 (612)
Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673)
(C) RH End of case to LH end of wireway 42 1/8 (1070) 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363)
RH End of case to the center of RH waste outlet 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307)
Back O/S of case to center of waste outlets 31 5/8 (804) 31 5/8 (804) 31 5/8 (804) 31 5/8 (804)
Schedule 40 PVC drip pipe 1 1/41 1/41 1/41 1/4
Refrigeration Outlet
Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) 26 1/4 (665) 26 1/4 (665)
RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203)
PHYSICAL DATA
Merchandiser Drip Pipe (in.) 1 1/4
Merchandiser Liquid Line (in.) 3/8
Merchandiser Suction Line (in.) 5/8