HYCON FLEX HPP14V User manual

HPP14V FLEX
Hydraulic Power pack
From serial
number 17415
Prior to Operation
We thank you for choosing a
HYCON powerpack.
Please note that the power-
pack is delivered without hy-
draulic oil, and therefore it
must be filled up with hydrau-
lic oil prior to operation.
To ensure smooth operation
and long-lasting performance
of your new powerpack, we
recommend that you study
this operating manual carefully
and pay special attention to
the
Safety and Service
Precautions
We hope you will be satisfied
with your new HYCON power-
pack.
Best regards
HYCON A/S
HYCON A/S
Juelstrupparken 11
DK-9530 Støvring
Denmark
Tel: +45 9647 5200
Fax: +45 9647 5201
Mail hycon@hycon.dk
www.hycon.dk

1
Contents
Page
Safety Precautions............................................................................................ 2
Filling up Hydraulic Oil ...................................................................................... 2
Technical Data ................................................................................................. 3
Starting Instructions ......................................................................................... 4
Service, Maintenance and Hydraulic Settings...................................................... 5
Oil Types ......................................................................................................... 6
Warranty Terms ............................................................................................... 6
EC-Declaration of Conformity... ......................................................................... 7
Warranty Terms…………………………………………………………………………………………….8

2
Safety Precautions
1. Always use protective earplugs. The powerpack complies with the EU noise limits,
but by daily long-lasting operation there is a risk of hearing defects.
2. Always connect hoses before starting.
3. Never add fuel and oil when the engine is running.
4. In case of non-operation or performance of service, always turn off the engine.
5. Never start the engine without side covers.
6. Operation of the powerpack without tool connected and with lever at “ON” may
cause overheating of the system and damage to the powerpack.
7. When lifting the powerpack from a vehicle, we recommend the use of a crane.
8. The pressure relief valve is set at 150 bar from our plant. Never set it higher.
9. Always use filters with by-pass. The use of filters without by-pass may blow the
hydraulic hoses and the filter cover.
Filling Up Hydraulic Oil
•To fill up with hydraulic oil, loosen the
filter cover on top of the powerpack.
•Remove the filter element (see photo),
and fill up with oil. When oil is showing
at the bottom of the filter unit, there is
enough oil on the powerpack.
•Insert the filter element again, mount
the cover and the powerpack is ready
for use.
Please note: When connecting new extension
hoses, it is necessary to fill up with extra 2 litres of
oil. Therefore always top up the powerpack when
connecting new extension hoses.

3
Technical Data
Hydraulics
The HYCON HPP14V open centre hydraulic powerpack is designed in accordance with
the EHTMA categories C and D, which prescribe a minimum performance of 20 l.p.m.
at 138 bar and 30 l.p.m. at 138 bar, respectively.
With manual flow adjustment. This powerpack can be set to 20 to 30 l.p.m. on the
front of the powerpack.
The powerpack is mounted with a pressure relief valve to avoid a too high pressure.
Furthermore, the very efficient air cooling protects the powerpack against
overheating.
Metric Imperial
Oil flow
At 2500 r.p.m 20 l.p.m. 5,0 g.p.m
At 3600 r.p.m 30 l.p.m. 7,5 g.p.m
Working pressure nominal 120 bar 1750 psi
Pressure relief valve Set at 150 bar 2200 psi
Pump Gear pump
Oil temperature Max. 70° C 160°F
Hydraulic oil tank capacity
Min/max 6 liters/ 8 liters 1,6 gallon / 2,1 gallon
Petrol tank capacity 6.5 litres 1,7 gallon
Hydraulic system compl. Max 9 litres Max 2,4 gallon
Filter system (filter element) 25 Micron with by-pass
Engine Vanguard 400
14 HP (gross power)
4-stroke petrol
with oil alert system
Petrol - normal or unleaded
Engine oil 1.1 litres/0,5 gallon
Metric Imperial
Guaranteed sound power level LWA 101 dB
Nominal pressure 103 bar 1490 psi
Nominal flow 27 l.p.m 5,8 g.p.m
Dimensions (LxWxH) mm/inch 705x550x645 28 x 22 x 25
Weight, without hydraulic oil 81 kg 202,5 lbs

4
Starting Instructions
Please observe the starting instructions on the front of the powerpack.
Start: •Check engine oil level
•Check hydraulic oil level at sight glass
•Connect hoses and tool
•Switch fuel tap to “ON”
•Activate choke
•Turn ignition switch to “1”
•Pull recoil starter
•Move the lever to the desired flow
Stop: •Move the lever to “OFF“
•Turn off the ignition switch
•Turn the fuel tap to “OFF”
Powerpack with adjustable flow:
The desired oil flow can be set on the front of the
powerpack. A marking is engraved in the lever.
Turn the lever to the right until the marking is
opposite the required flow
The pressure relief valve setting will be the same
on all flows.

5
Service, Maintenance and Hydraulic Settings
Service/Maintenance
Daily
Weekly
Yearly
Engine oil
Check
1 x replacement
Hydraulic oil
Check
1 x replacement
Hydraulic oil filter *)
1 x replacement
Check hoses
(tighten up if needed)
Air filter
1 x replacement
Fuel filter
1 x replacement
*) Use only filters with by-pass
Hydraulic Settings
Check the working pressure by means of test equipment. The test equipment must
comprise a pressure gauge, a flow meter and a valve for adjustment of pressure.
The pressure relief valve is placed on the right side of the valve block.
1. Connect the test equipment, start the powerpack and move the lever to “ON”.
Then close the valve - the pressure gauge must show 150 bar.
Adjust the pressure relief valve by loosening the lock nut and turning the
adjustment screw in or out. “In” increases the pressure, and “out” decreases the
pressure.
Retighten the lock nut after adjustment.
2. When the pressure relief valve has been adjusted correctly, the working pressure
must be set at 100 bar by means of the valve on the test equipment. At 100 bar,
the oil flow should be 20 (30) l. p.m.
On the powerpack with adjustable flow, the flow is regulated by adjusting the
position of the throttle cable.
If correct pressure/oil flow cannot be achieved by following the
above instructions, the powerpack must be re-adjusted. If the
pressure/oil flow is then still incorrect, the pump is defect and
must be replaced.

6
Oil Types
The HYCON powerpack uses standard hydraulic oil, i.e. all types of mineral oil and
biodegradable oil, which comply with the following values:
Ambient temperature range
Below 10°C
50°F
10 … 30°C
50 … 86°F
Above 30°C
86°F
Recommended oil viscosity grade
VG 32
VG 46
VG 68
Recommended oil cleanliness
ISO 4406 /19/16 / NAS 1638 10
Permitted viscosity
cSt
10 –600
Viscosity index
Minimum
100
Oil temperature area
°C /°F
-20 to 70 / -4 to 158
Warranty Terms
We grant 12 months warranty from the first date of operation –however, not more
than 18 months from the date of delivery.
The warranty applies to faults that can be related to construction and production
errors.
Faults caused by incorrect operation, incorrect handling, lack of maintenance or the
like will not be accepted as warranty.
The warranty covers the parts necessary for repair and the suggested average time
needed for repair.
For further warranty details, please contact your local dealer.

7
EC-Declaration of Conformity
We hereby declare that
HPP14V hydraulic powerpack –from serial No. 17415
(with 10.3 kW petrol engine)
is manufactured in conformity with the EC Directives 2006/42/EC and 2000/14/EC.
Notified Body 2914:
Sweco Danmark A/S
Ørestads Boulevard 41
2300 København S
Danmark
Guaranteed sound power level: 101 dB
HYCON A/S
Juelstrupparken 11
DK-9530 Støvring
Denmark
Martin Møller
Managing Director
22.04.2022
HYCON A/S
Juelstrupparken 11
DK-9530 Støvring
Denmark
Tel: +45 9647 5200
Fax: +45 9647 5201
Mail hycon@hycon.dk
www.hycon.dk

8
Warranty Terms
We grant 12 months warranty from the first date of operation –however, not more
than 18 months from the date of delivery.
The warranty applies to faults that can be related to construction and production
errors.
Faults caused by incorrect operation, incorrect handling, lack of maintenance or the
like will not be accepted as warranty.
The warranty covers the parts necessary for repair and the suggested average time
needed for repair.
For further warranty details, please contact your local dealer.
Table of contents
Other HYCON Power Pack manuals

HYCON
HYCON HPP18E FLEX User manual

HYCON
HYCON HPP06 User manual

HYCON
HYCON HPP18E FLEX User manual

HYCON
HYCON HPP26DMF User manual

HYCON
HYCON HPP27VMF User manual

HYCON
HYCON HPP18V FLEX User manual

HYCON
HYCON HPP13D User manual

HYCON
HYCON HPP09 User manual

HYCON
HYCON HPP09 User manual

HYCON
HYCON HPP09 Instruction manual