manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. hyfire
  6. •
  7. Security Sensor
  8. •
  9. hyfire TAURUS TAU-TH-01 User manual

hyfire TAURUS TAU-TH-01 User manual

This manual suits for next models

1

Other hyfire Security Sensor manuals

hyfire Taurus TAU-MC-01 User manual

hyfire

hyfire Taurus TAU-MC-01 User manual

hyfire TAURUS TAU-OP-01 User manual

hyfire

hyfire TAURUS TAU-OP-01 User manual

hyfire HFI-DPT-05 User manual

hyfire

hyfire HFI-DPT-05 User manual

hyfire HFI-DPT-05 User manual

hyfire

hyfire HFI-DPT-05 User manual

hyfire HFW-TRI-05 User manual

hyfire

hyfire HFW-TRI-05 User manual

hyfire TAURUS TAU-OP-01-BL User manual

hyfire

hyfire TAURUS TAU-OP-01-BL User manual

hyfire ALTAIR HFI-MA-05 User manual

hyfire

hyfire ALTAIR HFI-MA-05 User manual

hyfire ALTAIR HFI-PA-05 User manual

hyfire

hyfire ALTAIR HFI-PA-05 User manual

hyfire TAURUS TAU-TH-01/DWB User manual

hyfire

hyfire TAURUS TAU-TH-01/DWB User manual

hyfire YAURUS TAU-OP-01-BL User manual

hyfire

hyfire YAURUS TAU-OP-01-BL User manual

hyfire TAURUS TAU-TH-01-BL User manual

hyfire

hyfire TAURUS TAU-TH-01-BL User manual

hyfire Taurus Series User manual

hyfire

hyfire Taurus Series User manual

hyfire HFW-TA-05 User manual

hyfire

hyfire HFW-TA-05 User manual

hyfire HFW-MA-05 User manual

hyfire

hyfire HFW-MA-05 User manual

hyfire TAURUS TAU-MC-01 User manual

hyfire

hyfire TAURUS TAU-MC-01 User manual

hyfire TAURUS TAU-MC-01/DWB User manual

hyfire

hyfire TAURUS TAU-MC-01/DWB User manual

hyfire TAURUS User manual

hyfire

hyfire TAURUS User manual

hyfire Taurus TAU-OP-01 User manual

hyfire

hyfire Taurus TAU-OP-01 User manual

hyfire Altair Series User manual

hyfire

hyfire Altair Series User manual

hyfire TAURUS TAU-MC-01 User manual

hyfire

hyfire TAURUS TAU-MC-01 User manual

hyfire ALTAIR LITE Series User manual

hyfire

hyfire ALTAIR LITE Series User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

UNBOXING
• When unboxing the detector you will find the unit and its mounting base.
• This comes with pre-formed mounting holes to mountthe detector base and a securing screw
on the base to ensure there is no unwanted removal.
For more information, please refer to the complete product manual.
IMPORTANT TO CONSIDER
When mounting a wireless device a comprehensive radio survey
should have been carried out to establish the location that provides
the best coverage and optimum reach. Taking into consideration the building
structure and materials, the survey identifies the wireless infrastructure
required and product locations for optimum performance, identifying
any factor that could prevent radio integrity.
Avoid fixing or mounting the unit close to the following:
• Equipment that utilises large electrical currents
• Large metal objects or structures
• Fluorescent lighting fittings
• Metal ceiling structures
• IT cabling.
Keep 2 meters minimum spacing between other wireless equipment
in the area to avoid signal interference.
EN54 approved environmental temperature range is -10°C to +55°C
• Remove the detector’s dust cover, intended to protect
the unit during shipping.
• Remove the detector from the base twisting
anticlockwise.
Remove the battery compartment cover on the base
on the detector.
• A plastic pop out tag is removable from the base
to enable you to label the address of the detector,
prior to fixing to the ceiling: popout the device label tag
from the base and insert it into the side.
• Screw the base to the ceiling using all fixing holes
and appropriate-sized screws.
1
3
2
4
MOUNTING STEPS
Proceed as follows to complete the device installation.
5 6
Ensure the programming switch in the base of the detector
is in position ON.
Remove the batteries’ insulating tab ensuring
the batteries are kept in their lodgement.
MOUNTING
HOLES
REMOVABLE
TAG
UNLOCK
SWITCH
ON REMOVE
INSULATING
TAG
INSIDE THE BOX
• 1 x Heat Detector
with mounting base
• 2 x CR123A batteries
• 1 x Quick start guide
• 1 x QR code
• Locate the mounting holes and mark them using a pencil
on the desired surface you are drilling.
•Using asuitable-sized drill bit (6 mm) drill the marked
screw points on your chosen surface.
• Ensure you use the correct fixings for the type of surface
you are mounting to.
TAU-TH-01
HYFIRE TAURUS HEAT DETECTOR
QUICK START GUIDE
Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV8 1NP
T
: +44 (0)1926 485282, E: info@hyfirewireless.co.uk, W: www.hyfirewireless.com
L50-DT-1400 (Rev_P.4)
THE BOX
Taurus QR code
Manual QR code
Product code
Product name
TAU-TH-01
Hyfire Taurus
Heat Detector
Available also in black plastic: TAU-TH-01-BL
• Move the switch in the base of the detector
to position 1.
• The detector’s LED will blink few seconds green
and then signal alternatively green / red 4 times.
• Ensure you replace the battery cover as this forms
part of the detectors anti tamper protection and refit
the detector locating it into the base twisting clockwise.
The detector’s LED will signal 4 times red.
SWITCH 1
9
7 8
LOCK
LED
• Secure the screw on the base to ensure there is
no unwanted removal using a M3 allen key.
• Put the QR code available in the box either on
the system map or on the dedicated pages at the end
of translator or expander manual.
10
SCREW
TAU-TH-01
HYFIRE TAURUS HEAT DETECTOR
QUICK START GUIDE
Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV8 1NP
T
: +44 (0)1926 485282, E: info@hyfirewireless.co.uk, W: www.hyfirewireless.com
L50-DT-1400 (Rev_P.4)