HYQUEST SOLUTIONS PTY LTD
Multi Output Dry Transducer - Model WL3100 13 ISSUE 15: 4/9/15
COPYRIGHT ©
8.2 Sampling Mode – Single, Continuous, Averaging
In S/W Rev 7.1 and lower, the last menu item shown on page 12 is “Continuous Mode ?”.
This could either be set to YES or NO.
When “Continuous Mode” is set to “NO” the WL3100 only takes a sample when :
1. The water level is displayed on the LCD or
2. An SDI-12 Measure command is received or
3. The 4-20mA loop power is detected.
When “Continuous Mode” is set to “YES” the WL3100 takes a sample :
1. Every 12 secs. (Continuously)
(This is useful if you use the SDI-12 command 0R0! as it will immediately
return the most recent measurement made within the last 12 secs – which
makes the WL3100 SDI-12 interface the same as the AD375A SDI-12
interface. It can also be useful when using the 4-20mA interface, as the 4-
20mA loop current will be accurately updated 100mS after loop power is
applied – without having to wait 12 secs for a measurement to be made !!)
In S/W Rev 7.2 and higher, the last menu item shown on page 12 is “Sampling Mode”. This
could either be set to Single, Contin+Avg 1, Contin+Avg 2,……..., Contin+Avg 20.
When “Sampling Mode” is set to “Single” the WL3100 only takes a sample when :
1. The water level is displayed on the LCD or
2. An SDI-12 Measure command is received or
3. The 4-20mA loop power is detected.
When “Sampling Mode” is set to “Contin+Avg X” the WL3100 takes a sample :
1. Every 12 secs. (Continuously)
(When a sample is requested, via the display or via SDI-12 or 4-20mA, the last
Xsamples are averaged. If it is known that the water level will change very
slowly, it is advantageous to set X to a high number, so that the last say 20
samples will be averaged. Note that 20 samples will take 20 x 12secs = 240
secs = 4 mins. (So the water level is averaged over a 4 minute period) If it is
known that the water level changes rapidly, then it would be better to set X to a
low number, so that say 2 samples will be averaged.)
The “Contin+Avg 1” mode only averages 1 sample, which at first appearance
doesn’t seem to be very useful – this was included to give the same operation
as the above described “Continuous Mode” set to “YES”. (Read the description
above to see why this mode is useful.)