Hytronik HBP01 Operator's manual

Lighting Control With Wireless Technology
Touch Panel HBP01
Human Centric Lighting System
Note:
This datasheet is intended for information related to the HBP01 panel only. For detailed information realted to the Hytronik Human Centric system, please refer to
the System data sheet and App user guide available from our website.
Free smartphone App for
set-up and commissioning
iOS
A wall-mounted touch panel designed to operate with the Hytronik range of
bluetooth wireless controls. It features support for human centric features to
provide elegant control of pre-dined circadian rhythm proles to suit ofce,
education and healthcare applications. 4 programmable one-touch scene
recall memories are provided, as well as brightness and white balance control.
The HBP01 is programmable using the free to download Hytronik APP on both
iOS and Android platforms.
Bluetooth Touch Panel
HBP01
EMC standard (EMC)
Safety standard (LVD)
Certication
EN55015, EN61000, EN61547
Semko, CB, CE , EMC, RED, RCM
EN60669, AS/NZS60669
Safety and EMC
Operation temperature
Relative humidity
Ta: 0
O
C ~ +50
O
C
20% ~ 90%
Environment
IP20IP rating
Ofce / Commercial Lighting
Classrooms
Hospital / Healthcare
Applications
Features
5 Year, 50,000hr Warranty
Technical Data
7 dBm
2.4 GHz - 2.483 GHz
Operation frequency
Transmission power
Range (Typical indoor)
Protocol
15~30m
Bluetooth Transceiver
4 Wireless Mesh
Stand-by power
Input Characteristics
Operating voltage
<1W
220~240VAC 50/60Hz
With night light 0.35W
Free smartphone (iOS and Andriod) App for set-up and comissioning:
Circadian rhythm control
Scene control
Congurable night light
Time sustainability: The touch panel HBP01 can keep the time runing for up to
1 month during power failure.

To maximise the bluetooth transmission range in every direction, the following considerations should be taken into account when
situating the HBP01control panel:
Installation and Placement Notes
Smart Phone to Device RangeDevice to Device Placement
Strong signal sources such as WiFi routers
and microwave ovens will affect the range
Concrete walls
Metals, and other
building materials
will reduce the range
Device placement may offer up to 30m communication
distance. However, we recommend for indoor applications
that device placements should be no further apart than 15m.
S ͽS
Notes:
The range for which a smart phone can communicate with the
lighting points will vary from model to model and is dependant
on its capability.
Other environmental factors (as per opposite) will
inuence the ultimate achievable range of communication
between smart phone and the HBP01 and HBHC25 devices.
Dimensions and Terminals
Wire Preparation
Wiring Diagram
0.75 - 4
mm
8mm
Wp
Rising clamp terminal.
To make or release the wire from the terminal, use a screwdriver
to push down the button.
35.6
12.1
86
86
N
N
HBP01
L
L

Automatic Mode Buttons
The Ofce/Classroom prole may be resumed at anytime by pressing this button.
If manual adjustments are made from the Ofce/Classroom mode, the user settings will be cancelled and the lighting levels restored
according to the Ofce/Classroom prole after the person has left the room (the HBHC25 occupancy sensor times out) and
automatic mode is resumed.
The Healthcare prole may be resumed at anytime by pressing this button.
In Healthcare mode, any manual adjustments are retained until 00:00h (12am), upon which the user settings will be cancelled and
the Healthcare prole will be automatically resumed.
Operation
1
.
.
4
Classroom
Office/
Healthcare
Ÿ
WARM
COOL
Ÿ
Ÿ
DOWN
UP
Ÿ
On/Off
ŸŸ
ŸŸ
1
2
3
4
Office/ Healthcare
Classroom
DOWN WARM
UP COOL
Brightness
Control
White
Balance
Control
Scene memories are simply
programmed using the APP.
Create and name the scenes using
the scenes menu, then assign the
scenes to memory buttons 1 - 4
from the device settings menu.
Scene Memory Recall
The On/off button has a congurable response via the APP.
1) Permanent off (Occupancy sensor disabled).
The off button will suspend the entire system, including occupancy sensor. Pressing this button again will resume the last automatic
prole selected, or pressing any other button on the control panel will wake up the system according to the button pressed.
2) Temporary off (Occupancy sensor remains active).
Ofce prole - The off button will turn off the lights and any manual mode settings are cancelled. Automatic mode is resumed
according to the prole and the lights will turn on again automatically from the occupancy sensor, or according to function from a
button selection on the HBP01.
Healthcare prole - The off button will turn off the lights and any manual settings will be retained until 00:00h (12am). Pressing this
button again before 00:00h will resume the previous lighting levels,as will the lights being turned on via the occupancy sensor.
Pressing any other button to turn on the system will operate the lights according to function.
Manual Mode Buttons
Night Light
The HBP01 features a night light for convenience. Its operation is fully congurable in the app.

Dene the function of the standby button:
ON-OFF - Toggle lights on/off
Only OFF - Standby button will switch lights off. Turned on again by timer or sensor.
Only On - Standby button will switch the lights on. Turned off by timer or sensor.
OFF type:
Normal OFF - Switch lights off, they may be turned on again
by timer or sensor.
Always OFF - Switch lights off, sensors and timers will be ignored. Pressing the standby
button again will return the system to sensor and timer control.
Turns on/off the keypad sounder
Dim step:
Choose the lighting % change each time the UP/DOWN buttons are pressed.
CCT step:
Choose in Kelvin the Colour change step each time the COOL/WARM buttons
are pressed
Turns on or off the keypad backlight
Control the keypad backlight brightness
The keypad backlight
can be programmed
to automatically switch
on using the built-in
photo-cell or by using
a time clock
In photocell mode, set the natural light level at
which the keypad backlight turns on/off.
Select disable for always on.
In timer mode, set the times at which the
keypad back light turns on/off
---------->
Select
Scene assignment. Press button 1-4 from the
image or the list to open the scenes menu.
Control assignment.
Press anywhere in the green
highlighted area of the image
or ‘manual control’ from the list
to enter this set-up screen.
Choose the scene to be
selected by the button 1-4.
A new scene may be created
by using the ‘+’ button
Device Settings - see below.
The panel controls all the devices in the network.
Control custom group
Choose this option when you
wish the panel to control
selected devices in 2 or more
rooms.
Control a room
Choose this option when you
wish the panel to control
all the devices in a single
room
Control a device
Choose this option when you
wish the panel to control
a single device.
Where a device has multiple
output channels, select the
channel to be controlled.
As you make settings, the image of the panel
will become active for testing the button responses.
App information
Other Hytronik Touch Panel manuals