1. Introduction.........................................................................................................4
2. Solar collector...................................................................................................5
3. Technical characteristics...........................................................................6
4. Observation points........................................................................................6
5. Dimensioning Plates Quantity.................................................................8
6. Pump Size...........................................................................................................9
7. Equipment Installation and Setup........................................................10
8. Maintenance....................................................................................................13
9. Product Warranty..........................................................................................15
10. Customer service........................................................................................16
1. Introduction
VIBEA solar heaters were designed to extend the pool season using solar
energy for that. VIBEA solar collectors are responsible for capturing solar
energy and transforming it into thermal energy, transferring this thermal ener-
gy to the pool water carrying out heating. The pool solar collector is a product
developed 100% in polypropylene with additives that guarantee durability,
resistance and total use of a renewable and non-polluting energy source.
This manual contains basic information about solar collectors and their ac-
cessories, as well as important installation instructions and tips, according
to our standards.
VIBEA 3X1 Collector Image
04

2. Solar collector
The VIBEA pool solar collectors have been developed to heat large volumes
of water with maximum savings. The solar collector is manufactured with
reliable, ecient products and preserving the environment, either by saving
energy or using clean materials and processes that are not aggressive to the
environment and people. The solar collector is manufactured with virgin raw
material (polypropylene) and has unique characteristics that are:
- Easy to install due to the use of joint at the ends;
- Resistant to working pressure up to 40 M.C.A (4.0 bar);
- Resistant to weather and chemicals contained in the pool water;
- Nontoxic raw materials;
- Large absorption area;
- No risk of corrosion.
VIBEA solar heating collectors can be installed directly on a mounting surfa-
ce or on a raised device, and can be installed on the roof or on the floor, also
considering changes in inclination angles.
The operation of the collector is simple, through an electronic controller (not
supplied by VIBEA) the pump system is activated when there is sucient
accumulated thermal energy, once this is done, the heating process starts
up to the chosen temperature. After reaching the temperature, the pool will
remain the same until there is no more energy to do so.
05
3. Technical characteristics
4. Observation points
The panels must be located as close as possible to the pool and its engine
room, in order to reduce heat losses and costs with interconnecting pipes.
06

Inclined collectors produce more energy during periods of mild temperatures,
in addition to promoting the flow of water inside.
The installation must be done avoiding shaded areas. Observe if the installa-
tion site of the collectors supports the dimensioned quantity and the weight
of these collectors filled with water. Leave enough space for the maintenance
of the collectors.
4.1. Inclination angle
Ideally, the angle of inclination varies from the latitude of the place to latitude
+ 15 degrees, in most cases, in Brazil, 17 degrees is enough.
The direction of the collectors should be towards the geographical north.
In case it is not possible, there will be a need to make a correction in the cal-
culation of their quantity.
Up to 15⁰ deviation to the east or west there is no need for correction.
Otherwise, use the guidelines, as shown in the table below:
07
For correct dimensioning of the required number of plates, the recommended
temperature must be taken into account for each type of pool use, according
to the temperatures recommended in the table below.
The following table indicates the recommended multiplication factor for
calculating the collector area required for the pool to be heated to the same
temperature in hot and cold climates.
For vinyl pools, check with the vinyl manufacturer for the ideal temperature.
Dimensioning Plates Quantity
Example: For a pool 6.00 m X 3.00 m = 18 m² of water depth. In hot climates, 6 VIBEA
3x1 plates or 9 VIBEA plates are installed.
08

10
The VIBEA collector has a great advantage, which is to have a plate approxi-
mately 1 meter wide and not have the need to use o-rings and locks, since the
collector was designed with joints in all its inputs and outputs, thus facilitating
and optimizing their assembly time.
Make sure the roof is facing north so that the collectors receive the sun most
of the day and have a better use.
An important factor in the installation of VIBEA solar collectors is related to
the number of plates per battery, the best thing is not to exceed 21 m² of plate
per battery, while taking into account the flow of the pump, as the distance
to be taken must be considered from the engine room to the roof where the
collectors will be installed. The number of plates per battery is specified in the
Important points!
Always consider in case of swimming pools of gyms / physiotherapy clinics or
even clubs, you should use an auxiliary heater. Always consult the factory in
situations of large pools so that it can assist in a more adequate dimensioning.
6. Sizing of the Pump
Knowing the size of your pool in square meters (m²) it is possible to dimension
the motor pump and the hydraulic network pipe to be used.
Disclaimer:
Use an independent motor pump to install your solar collector.
To carry out the sizing of the motor pump and the proper piping for installation,
it must be taken into account that the collector needs to have an excellent
functioning, for this it is necessary to have a flow of 250 liters of water per
m² of solar collector per hour, that is, , an example is an 18 m² swimming pool,
4,500 liters of water are needed per hour considering that the collector is
fixed on the roof, with these data pass your motor pump supplier the data
below so that it analyzes the ideal pump and your pipe.
Tips!
- Keep the distance from the machine room to the roof where the solar collector
will be.
- Have the height of the roof in relation to the engine room.
- Always consider the correct piping to be installed for each system, as shown
in the table below.
09

11
The use of thermal cover over the pool is essential for optimal functioning.
Always check the ideal pressure for each installation to avoid insuciency
or excess flow.
Check if the collectors are properly fixed, because in case of strong wind or
storm, there may be detachment, generating possible leaks in the pipe joints,
or even the complete detachment of the roof or support.
The collector piping is resistant to degradation by the action of products used
in pool maintenance, such as chlorine. In the table below, the plate sizes for
the most common pool measurements are presented.
table below. In the case of large swimming pools, we ask that you contact the
factory to assist in dimensioning. We recommend that the installer leave the
plates level, so that the sealing of the joints is the best possible, remembering
that all plates are tested at the factory with water.
12
7.1. Standard Installation System
The following is an example of the scheme for installing the entire pool heating
set, using a 2 x 5 m pool as a standard model, totaling an area of10 m², where
the use of a battery with 5 (five) is indicated VIBEA 2 X 1 collectors.
Motor pump

13
For the union of the collectors it is not necessary to use any welding process,
glues or other materials, the fitting is done through male / female threaded
connections, it is enough to fit one collector to the other or a collector to the
system piping.
The collectors must be installed on a flat surface, favoring the proper union
between them and avoiding leaks.
During transportation and handling, excess weight on the collectors must
be avoided in order to avoid possible damage to the equipment.
7.2. Tests and Verifications
Before running water through the system:
1. Check that all connectors are locked and tight.
2. Check that all supports are attached to the roof and aligned.
3. Check that all piping is supported or secured.
Test the system:
1. With water in the filter / pool tubing, open the collector supply and return
valves.
2. Activate the controller, the solar heating system pump, operating in “ma-
nual” mode.
3. Check for any leaks by checking all connections, including between the
collectors, and that the piping has remained secure and firm.
14
8. Maintenance
This section will allow you to identify some of the most common causes of
operating problems.
8.1. Solutions Framework

9. Product Warranty
The warranty covers only manufacturing defects of the collectors and parts.
VIBEA solar collectors have a 5 (five) year warranty against manufacturing
defects.
The warranty does not cover:
- Damage arising from transport, when it is not carried out by VIBEA;
- Damage or damage caused by incorrect or improper use of the product;
- Damage or damage caused by weather conditions;
- Damage caused by pressure above the recommended;
- Damage caused by incorrect storage by the customer;
- Damage caused during installation, such as bumps, drops of plumbing,
bends in the pipes, dirt between connections, or joints damaged by incor-
rect handling and transportation to the roof;
- Damage caused by the use of the equipment for any purpose other than
heating water for swimming pools;
- Damage caused by ruptures of the solar collector due to negative tempe-
rature, when the digital controller is not installed, which must be turned on
in “automatic” even during winter.
- All expenses resulting from the removal, reinstallation and return shipping
of the product to VIBEA, when it is found that the defect did not originate in
the manufacturing process;
- System failure due to not using a thermal cover.
- When there are changes in the physical characteristics of the product, made
by the installer or user;
- When the basic requirements for electrical and hydraulic installation con-
tained in the manual are not complied with.
15
10. Customer service
For any questions or technical queries, please contact us:
Phone: (43) 3315-7900
Email: [email protected]
Website: www.vibea.com.br
Service Desk:
Rua Serra de Roraima, 100 – Jardim Bandeirantes
Londrina – Paraná,
CEP – 86065-640
16

ATTENTION:
VIBEA, RESERVES THE RIGHT TO CHANGE
THE CONTENT OF THIS MANUAL OR PART OF
IT, WITHOUT PRIOR NOTICE AND WHENEVER
THERE IS A NEED.

ra de Roraima, 100
Jd. Bandeirantes - Londrina - PR
CEP 86065-640
vibea.com.br
Rua Ser
Vibea- All rights reserved @ 2020
Q
U
A
L
I
T
Y
P
R
O
D
U
C
T
S
F
O
R
Y
O
U
T
O
E
N
J
O
Y
Y
O
U
R
V
I
B
E
—
This manual suits for next models
2
Table of contents