COBALT Essential™Sensor Faucet
Standard Operations 102664
I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com
One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents
ACTIVATION
page 1
Rev 081023
To prevent ooding acvaons will stop aer 30 seconds.
AUTO ACTIVATION
The faucet will automacally acvate based on IR detecon. The IR sensor has 3 LEDs, a red, green, and blue to indicate detecon
and acvaon status.
When no object is detected no LED indicaon will be displayed.
During object detecon the faucet will blink a green LED in 5-second intervals. If the faucet is powered by a plug-in transformer
a solid blue LED will also illuminate.
MANUAL ACTIVATION
Press the acvate buon on the control module, this will toggle the water on and o.
SENTINEL ACTIVATION
Sennel acvaon will automacally acvate the faucet 24 hours aer the last acvaon, by default sennel acvaon is o.
To toggle this feature, hold down the acvate buon for 5 seconds The red LED located in the IR sensor window will stay on
for 3 seconds to indicate it has been turned on, or blink for 3 seconds if it has been turned o.
ACTIVATION REFUSAL
When an acvaon is aempted but the device is in a state of end-of-life baery, obstrucon, or disabled, a red LED will ash,
and the faucet will not acvate.
ALERTS
Alerts are indicated by a red LED ashing every 10 seconds.
OBSTRUCTION
When an object has remained detected for 30 minutes auto acvaons will be disabled. To reset an obstrucon alert, the faucet
must not detect anything for at least 5 seconds.
Acvaons cannot last more than 30 seconds. An obstrucon will not cause your faucet to run connuously.
LOW BATTERY
When the baery voltage has dropped below 6V.
BATTERY END-OF-LIFE
When the baery voltage has dropped below 5V. If the faucet is running only on baery power acvaons will be disabled
and the red LED will ash rapidly.