3 Rotary Switch & Default Settings
The definition of the rotary switch (VPD-142(N)-H):
Run the program. (Default)
Update a new application to the TouchPAD
device through USB.
The definition of the rotary switch (VPD-143(N)-H):
This is a special run mode which is used in
the development stage. The TouchPAD
device can be updated by a PC from the
remote side through Ethernet. (Default)
While the application run on the TouchPAD
device seriously crashes, use this mode to
update a new application to the TouchPAD
device through Ethernet.
Update a new application to the TouchPAD
device through USB.
Network Default Settings (VPD-143(N)-H)
4 First Use of the VPD 4.3”H Series
1. Connect wires as the below figure or prepare an Ethernet cable which
will be used to supply power through PoE if there’s a RJ-45 Ethernet port
on it. And set the rotary switch to 0 (At this point, the power is not yet
supplied).