ICP DAS USA ZT-2024 User manual

ICPDAS,ZT‐2024QuickStar,Version1.0.0Page1
Copyright©2014byICPDASCo.,Ltd.AllRightsReserved.
ZT‐2024
QuickStart
1
What’sintheShippingPackage?
The shipping package showed contain the following items:
2
PreparingtheDevice
1. Refer to Section 4. for details of how to configure the DIP switches of the
ZT-2000 I/O device.
2. Install the ZT Configuration Utility on your Host PC to configure the ZT-2000
coordinator. The utility can be founded on the CD in the
\Napdos\ZigBee\ZT_Series\Utility folder, or downloaded from:
http://ftp.icpdas.com/pub/cd/usbcd/napdos/zigbee/zt_series/utility
3. Power Supply: Connect a power supply using a voltage range of +10 ~ +30
VDC
+Vs GND +Vs
GND
CD
ANT‐124‐05QuickStart
ZT‐2024Device
If any of these items are missing or damaged, please contact your local distributor
for more information. Save the shipping materials and cartons in case you need to
ship the module in the future.

ICPDAS,ZT‐2024QuickStar,Version1.0.0Page2
Copyright©2014byICPDASCo.,Ltd.AllRightsReserved.
3
SettinguptheZT‐2000I/ODevice
3.1 IntroductiontotheConfiguration
Parameters
A. The “ZB PID” parameter is the group identity for a ZigBee network, and
must be same for all devices in the same ZigBee network.
B. The “Node ID” parameter is the individual identity of the specific ZigBee
module, and must be unique for each device connected to the same
ZigBee network.
C. The “ZB Channel” parameter indicates the radio frequency channel, and
must be set to the same value as other modules on the same ZigBee
network.
ZB Channel 0x00 0x01 …… 0x0F
Frequency (MHz) 2405 2410 …… 2480
※ ZB channels 0x04, 0x09, 0x0E or 0x0F are recommended because they do not
overlap with Wi-Fi frequency band.
D. Protocol/Application Mode:
When implementing custom programs based on different protocols, the
following application mode(s) are recommended in order to ensure
optimal performance.
User Program Protocol ZT-2000 I/O ZT-2550 ZT-2570
DCON DCON Transparent Transparent
Modbus RTU Modbus RTU Transparent
Modbus Gateway
Transparent
Modbus Gateway
Modbus TCP Modbus RTU ------ Modbus Gateway
000102030405060708090A0B0C0D0E0F
802.11b/g
ZBChannel1
802.11b/g
ZBChannel6
802.11b/g
ZBChannel11
802.11b/gZBChannel(NorthAmerica)
802.15.4ZBChannel
2400
MHz
2485
MHz

ICPDAS,ZT‐2024QuickStar,Version1.0.0Page3
Copyright©2014byICPDASCo.,Ltd.AllRightsReserved.
4
TheRotarySwitchandDIPSwitches
The configuration of the ZT-2024 can be adjusted using a combination of the
external rotary switch and the DIP switches. The ZT-2000 device should only be
rebooted once the configuration is completed.
ZT-2024
12345678910 11 12
Address LSB
(
Node ID
)
Address MSB
(
Node ID
)
Protocol
Checksum
ZB PID
ZB Channel
T
ype Code
ON
Data Format
RotarySwitch
0
(Software Config.) 1 2 3 …… F Note
Address *Note 1 01 02 03
…… 0F
Node ID *Note 1 0x0001 0x0002 0x003
…… 0x000F MSB =
0
0 1 2 3 …… F
Address 10 11 12 13
…… 1F
Node ID 0x0010 0x0011 0x0012 0x013
…… 0x001F MSB =
1
*Note1:The“Address”and“NodeID”aredefinedviathe%AANNTTCCFFcommand.Insoftware
configurationmode,theDIPswitchesfor“Address”,“DataFormat”and“TypeCode”
areignoredandcanalsobesetviathe%AANNTTCCFFand$AA7CiRrrcommands.

ICPDAS,ZT‐2024QuickStar,Version1.0.0Page4
Copyright©2014byICPDASCo.,Ltd.AllRightsReserved.
DIPSwitch
Number Item Status
Description
OFF Valid Address (Node ID) from 0x01 to 0x0F
1 Address MSB ON Valid Address (Node ID) from 0x10 to 0x1F
OFF DCON Protocol
2 Protocol ON Modbus RTU Protocol
OFF Disabled (DCON Protocol)
3 Checksum ON Enabled (DCON Protocol)
OFF ZigBee Pan ID = 0x0000
4 ZB PID ON ZigBee Pan ID = 0x0001
OFF ------
5 ON 0x08
OFF ------
6 ON 0x04
OFF ------
7 ON 0x02
OFF ------
8
ZB Channel
ON 0x01
OFF Engineering Units Format
9 Data Format ON Hexadecimed Format
Switch
Position
Type
Code
Switch
Position
Type
Code
Switch
Position
Type
Code
0x00
0x01
0x02
0x03
0x04
0x05
0x05
0x05

ICPDAS,ZT‐2024QuickStar,Version1.0.0Page5
Copyright©2014byICPDASCo.,Ltd.AllRightsReserved.
5
StartingtheZT‐2000I/ODevice
As the ZigBee network is controlled by the ZigBee Coordinator, the
ZT-2550/ZT-2570 (ZigBee Coordinator) must be configured first. Refers to the
documents shown below for full details of how to configure these devices.
Once configuration of the ZigBee Coordinator has been completed, set the “Pan
ID” and “RF Channel”values for the ZT-2000 I/O device to the same values as
the network and then reboot the device.The module will automatically start to
function on the ZigBee network using the default protocol.
※ Documents
http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-255x/
http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-257x/
※ Configuration Utility (Used to configure the ZT-2000 I/O device
Coordinator)
http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/utility/

ICPDAS,ZT‐2024QuickStar,Version1.0.0Page6
Copyright©2014byICPDASCo.,Ltd.AllRightsReserved.
6
Examples
ConfiguringtheZT‐2550/ZT‐2570
ConfiguringtheZT-2000 I/O Device
12345678910 11 12
Number Item Status Description
1 Address MSB OFF Address/Node ID is 01 (Rorary Switch=1)
2 Protocol ON Use Modbus RTU Protocol
3 Checksum OFF Disabled
4 ZB PID OFF Pan ID=0x0000
5 ON 0x08
6 ON 0x04
7 ON 0x02
8
ZB Channel
OFF ------
ZigBee RF Channel = 0x0E
9 Data Format OFF Engineering Units Format
10 OFF
11 OFF
12
Type Code
OFF
AO Type Code = Type Code 0 (0 – 20mA)

7
CommunicationsTesting
Once the ZT-2000 I/O device has joined the ZigBee network, the signal quality
can be confirmed by monitoring the status of the ZigBee Net LED indicators. If
the LED indicator shows a steady light, communication with the ZT-2000 I/O
device has been successfully established for data acquisition and control.
ICP DAS also provides the “DCON Utility”, which can be used to simulate
DCON/Modbus communication. This software can alse be used to verify the
device settings and ZigBee I/O functions.
※ The DCON Utility can be downloaded from:
http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/
mulating I/O channel operation via the DCON Utility Si
1. Launch the DCON Utility and select the appropriate COM Port settings to connect
to the ZigBee Coordinator (ZT-2550/ZT-2570).
2. Click the “Search” button to start searching for ZT-2000 I/O devices connected
to the same ZigBee network.
3. If any ZT-2000 I/O devices are found, they will be displayed in the device list
windows. Double-click the name of the module to start the operating platform.
1
2
3
ICPDAS,ZT‐2024QuickStar,Version1.0.0Page7
Copyright©2014byICPDASCo.,Ltd.AllRightsReserved.

ICPDAS,ZT‐2024QuickStar,Version1.0.0Page8
Copyright©2014byICPDASCo.,Ltd.AllRightsReserved.
8
Troubleshooting
(1) Technical Support.
If you have any difficulties using your ZT-2000 series I/O device, please
send a description of the problem to [email protected]
Include the following items in your email:
A description or diagram of the current DIP switch positions.
A copy of the configuration file for the ZT-2000 coordinator. This file can be
obtained using the procedure outlined below and should be attached to your
email.
a. Set the DIP switch of the ZT-255x device to the [ZBSET] position then
reboot the device. Launch the ZT Configuration Utility and select [Save Log]
icon to save the configuration of the ZT-255x as a file.
b. After clicking the [Save Log] icon, enter the “File Name” and the “File Path”
in the Windows “Save” dialog box. Once the configuration has been
successfully saved, the following message will be displayed.
Table of contents
Other ICP DAS USA Network Card manuals
Popular Network Card manuals by other brands

Intermate
Intermate Network Adapter A/T FS3 Quick installation guide

AeroComm
AeroComm ConnexLink user manual

Liebert
Liebert OpenComms Web Card user manual

Snell Advanced Media
Snell Advanced Media RollPCI user manual

Telit Wireless Solutions
Telit Wireless Solutions WE866E4-P Hardware user's guide

Dell
Dell Broadcom NetXtreme Family of Adapters user guide