SPECIFICATIONS - SURGE PROTECTORS
SPECIFICATIONS - NOISE FILTERS
Input Voltage
Range
Continuous
Current
Intermittent
Current
Filter Frequency
Range
SPM-12ADL
SPM-25ADL
SPM-40ADL
0-12 VDC 12.0 Amps 16.0 Amps 10 Hz - 200 MHz
0-12 VDC 25.0 Amps 35.0 Amps 10 Hz - 200 MHz
0-12 VDC 40.0 Amps 55.0 Amps 10 Hz - 200 MHz
Input Voltage
Range
Continuous
Current
Intermittent
Current
Filter Frequency
Range
PCM-12ADL
PCM-25ADL
PCM-40ADL
0.10-100 VDC 12.0 Amps 16.0 Amps 10 Hz - 200 MHz
0.10-100 VDC 25.0 Amps 35.0 Amps 10 Hz - 200 MHz
0.10-100 VDC 40.0 Amps 55.0 Amps 10 Hz - 200 MHz
ICT Ltd. warrants to the original consumer purchaser that this
product shall be in good working order, free from defects in
materials and workmanship, for a period of one (1) year from the
date of purchase. Should failure occur during the above stated time
period, then ICT will, at its option, repair or replace this product at
no additional charge except as set forth below. All parts, whether
for repair or replacement, will be furnished on an exchange basis.
All exchange pieces become the property of ICT. This limited
warranty shall not apply if the ICT product has been damaged by
unreasonable use, accident, negligence, disaster, service, or
modification by anyone other than the ICT factory.
Limited warranty service is obtained by delivering the product
during the above stated one (1) year warranty period to an
authorized ICT dealer or ICT factory and providing proof of purchase
date. If this product is delivered by mail, you will insure the product
or assume risk of loss or damage in transit, and prepay shipping
charges to the factory.
Every reasonable effort has been made to ensure that ICT product
manuals and promotional materials accurately describe ICT product
specifications and capabilities at the time of publication. However,
because of ongoing improvements and updating of ICT products,
ICT cannot guarantee the accuracy of printed materials after the
date of publication and disclaims liability for changes, errors or
omissions.
If this ICT product is not in good working order, as outlined in the
above warranty, your sole remedy shall be repair or replacement as
provided above. In no event will ICT be liable for any damages
resulting from the use of or the inability to use the ICT product,
even if an ICT employee or an authorized ICT dealer has been
advised of the possibility of such damages, or for any claim by any
other party.
ICT reserves the right to make changes without further notice to
any products or documentation for improvement of reliability,
function, or design.
ICT Ltd. does not recommend use of its products in life support
applications wherein a failure or malfunction of the product may
directly or indirectly threaten life or cause injury. The user of ICT
products, which are to be used in life support applications as
described above, assumes all risks of such use and indemnifies ICT
against all damages.
LIMITED WARRANTY
INNOVATIVE CIRCUIT TECHNOLOGY LTD.
26921 GLOUCESTER WAY LANGLEY, BRITISH COLUMBIA, CANADA V4W 3Y3
T 604.856.6303 F 604.856.6365 www.ict-power.com
THEPOWEROFRELIABILITY
40A size
2.00
(50.8)
1.61
(41)
5.38
(137)
5.88
(149) 2.71
(69)
4.53
(115)
TOP VIEW
SIDE VIEW REAR VIEW
TORQUE RATING: 7 IN-LB MAX
WIRE RANGE: 20-10 AWG
DOUBLE-ROW TERMINAL STRIP
10A & 25A size
1.625
(41)
1.22
(31)
4.40
(112)
4.9
(124.5)
2.45
(62)
3.54
(90)
TOP VIEW
SIDE VIEW REAR VIEW
OUTLINE DRAWING
DIMENSIONS IN
INCHES (MILLIMETRES)
When the filter is being used to filter out noise
entering a piece of equipment, such as a mobile
radio or stereo system, it should be mounted as
close "electrically" as possible to the equipment.
When the filter is being used to filter sources of
noise such as small generators or electric motors,
then it must be as "electrically" close as possible
to these noise sources.
ICT POWER CONDITIONERS WARNING
NOTES
The ICT Noise Filters and the ICT Surge Protectors are
designed to filter out differential and common mode
noise which is present in industrial equipment,
automobiles and electrical systems. These conditioners
filter both positive and negative leads of the electrical
system. The ICT Surge Protectors also include a
transient surge protection device to protect 12 Volt
equipment from spikes and surges.
These instructions should be read before using the
product and it should be saved for future reference.
Incorrect wiring may result in serious damage to
both power conditioner and equipment wired to
power conditioner.




This manual suits for next models

6

Popular Water Filtration System manuals by other brands

sterling water treatment QCRO-50 installation manual

sterling water treatment

sterling water treatment QCRO-50 installation manual

Finerfilters RO50-DI-1 Installation and maintenance manual

Finerfilters

Finerfilters RO50-DI-1 Installation and maintenance manual

Fahl LARYVOX HME Instructions for use

Fahl

Fahl LARYVOX HME Instructions for use

Sicce Seachem Tidal Series owner's manual

Sicce

Sicce Seachem Tidal Series owner's manual

Fleck 5600SE Service manual

Fleck

Fleck 5600SE Service manual

WALPOL WNG-S1 Assembly and operating instructions

WALPOL

WALPOL WNG-S1 Assembly and operating instructions

Fluid Filtration AF 113 G3 TRANSLATION OF ORIGINAL INSTRUCTIONS

Fluid Filtration

Fluid Filtration AF 113 G3 TRANSLATION OF ORIGINAL INSTRUCTIONS

BWT AQA drink Magnesium Mineralized Water Protect... Installation and operating instructions

BWT

BWT AQA drink Magnesium Mineralized Water Protect... Installation and operating instructions

Eureka Forbes Aquaguard Eden user manual

Eureka Forbes

Eureka Forbes Aquaguard Eden user manual

Parker 660R-RAC Series installation guide

Parker

Parker 660R-RAC Series installation guide

SteriPEN Quantum user guide

SteriPEN

SteriPEN Quantum user guide

ACO ECOJET installation guide

ACO

ACO ECOJET installation guide

VitalBodies.com Vital H2O Installation and user manual

VitalBodies.com

VitalBodies.com Vital H2O Installation and user manual

HTC GL PS manual

HTC

HTC GL PS manual

Crossfire Hallett 13 instruction manual

Crossfire

Crossfire Hallett 13 instruction manual

Everpure MRS-350 quick start guide

Everpure

Everpure MRS-350 quick start guide

Merck Milli-Q Advantage A10 System Quick reference guide

Merck

Merck Milli-Q Advantage A10 System Quick reference guide

Amway eSpring 10-0185-CA owner's manual

Amway

Amway eSpring 10-0185-CA owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.