190 PINT MANUAL
Rated at 170-pints per day at 86°F/80% RH, 105 pints per day, AHAM - (80°F/60% RH)
#700837
All design and specifications herein are subject to change without
notice for product improvement. Contact Ideal Air for
details, updates and other information.
Contact Ideal Air Support directly
at support@ideal-air.com or call
1-877-9-IDEAL-1
Product not working properly?
DO NOT return this product to the
store where you purchased it.
For answers to most common questions and a complete
technical support library please visit
www.ideal-air.com
190 PINT MANUAL
Rated at 170-pints per day at 86°F/80% RH, 105 pints per day, AHAM - (80°F/60% RH)
#700837
All design and specifications herein are subject to change without
notice for product improvement. Contact Ideal Air for
details, updates and other information.
Contact Ideal Air Support directly
at support@ideal-air.com or call
1-877-9-IDEAL-1
Product not working properly?
DO NOT return this product to the
store where you purchased it.
For answers to most common questions and a complete
technical support library please visit
www.ideal-air.com
190 PINT MANUAL
Rated at 170-pints per day at 86°F/80% RH, 105 pints per day, AHAM - (80°F/60% RH)
#700837
All design and specifications herein are subject to change without
notice for product improvement. Contact Ideal Air for
details, updates and other information.
Contact Ideal Air Support directly
at support@ideal-air.com or call
1-877-9-IDEAL-1
Product not working properly?
DO NOT return this product to the
store where you purchased it.
For answers to most common questions and a complete
technical support library please visit
www.ideal-air.com
Rating @ 190Pint 86°F 80%RH
115Pint 80°F 60%RH

ONE:
IMPORTANT SAFETY INSTRUCTIONS
TWO:
INTRODUCTION OF CONFIGURATION
• Please read instructions carefully before using the machine.
• Please make sure the power supply is 115V/60Hz before operation.
• Please do not pull out the plug by pulling power cord.
• Please be careful while you move the machine, avoid tangling the power cord.
• DO NOT put fingers on any other objects into the machine barrier.
• DO NOT allow children to climb or sit on machine.
• Please remove the plug before cleaning.
• Please use a grounded power cord.
• Please do not use the machine in a airtight room.
• Please keep these instructions.
NOTICE:
We advise any repair should be done by a professional
repair person. We are not responsible for any problem which is
caused by unprofessional repair person.
NOTE:
The best humidity range for human health, furniture and
other goods protection is 45% - 65%. We suggest you keep the
humidity in this range.
Cover board
Air inlet
barrier
Crosspiece
Right board
Door
Control panel
Back board
Coil seat
Plug fixation
Wheels
Handle
Air outlet
Left board
1

THREE:
OPERATION INSTRUCTION
1) Button and icon instructions
2) Instructions of buttons:
a. ON/OFF: Each press ON/OFF, unit runs in a circulate “on-off-on”
b. Humidity Down: When unit runs on dehumidify mode, press
Humidity Down button each time, humidity falls 1%, press for 2
seconds, humidity falls by 5% per second.
c. Humidity Up: When unit runs on dehumidify mode,
press Humidity Up button each time, humidity raises 1%,
press for 2 seconds, humidity raised by 5% per second.
3) Instruction of function mode:
Unit makes a “BEEP” sound when powered on. Then when switch
button is in humidity mode, the indicator light of the Dehumidifier
will light up.
The default setting for humidity is 60%, the machine’s dehumidifying
range is 30%-90%. Use the Humidity Up and Down buttons to adjust
the humidity setting. If you keep pressing the Humidity Down button
when the humidity setting is at 30%, the unit will go into continuous
dehumidify mode which will show as “CO” (Continuous Operation)
on the the LCD display. The humidity % will flash when setting the
humidity, then display current humidity after 5 seconds.
2

FOUR:
NOTICE OF OPERATION
1. There is a 3 minute delay after machine has shut down prior to next start up cycle.
2. The machine will operate between 41°F – 89.6°F.
3. Do not place the unit on ground slopping more than 45 degrees.
4. We suggest wash the filter once per month. Immerse the filter in warm water when cleaning,
lightly brush, install after it air drys.
5. Make sure the machine’s air inlet and outlet are 10cm / 4” away from the wall to ensure
proper operation.
6. Completely clean water tank after using to avoid mold growth.
7. Pull out the plug if not using the unit for long periods of time. Coil the power cord on the coil
seat and insert the plug into the plug holder.
8. There is a door at the front of the machine. Press the top of the door, to open it automatically.
Remove the water tube, connect one end with water outlet to the water tank, and the other end
through the water drainage port on left side of machine. Maximum length of the tube is 20’.
When the room temperature is low, unit will run into Auto-Defrost function.
“Accumulative work time” on display means how much time unit have be operated. (This number is
calculated by ten minutes, the first ten minutes latest after power off doesn’t calculated in).
When above malfunctions occur and must be repaired, contact Ideal-Air technical support,
do not disassemble the machine privately.
Hot air blowing from the air outlet is normal.
FIVE:
TROUBLE SHOOTING
MALFUNCTIONS ANALYSIS SOLUTION
Does not humidify
1) Power failure
2) Switch is in off position
3) E4 is illuminated on display panel
1) Check Circuit breaker
2) Switch is in on position
3) Empty water tank
Dehumidify in low
1) Filter dirty
2) Blockage in air inlet or outlet
3) Room is not sealed
4) Temperature is low in room
1) Clean Filter
2) Remove Blockage
3) Close the doors, window and
block any sunlight
4) The dehumidify capacity is
low when room temperature
is low
Random noise
1) Unit is unstable
2) Air outlet clogged
1) Stabilize unit
2) Clean air filters
3

SIX:
ERROR CODES
This machine can identify some malfunctions itself. The error codes that may be displayed
are in the table below.
CODE PROBLEM
E3 Humidity sensor has failed
E4 Water tank is full
E5 Temperature sensor has failed
SEVEN:
TECHNOLOGY SPECIFICATION
TESTING CONDITIONS: 86°F & 80%RH
MODEL DS190
POWER 115V/60Hz
86°F & 80% RH 190 pint per day
NOMINAL RATED POWER
CURRENT 10.5 AMPS
NET WEIGHT 152 lbs
SIZE 26” X 22” X 42”
4

A/C – Air conditioning also
referred to as A/C. A system
or device for reducing the
temperature, & humidity, in
a space.
AHAM – Acronym for
Associavion of Home Appliance
Manufacturers. AHAM
produces the official rating for
dehumidifiers.
BTU – British Thermal Unit.
A single BTU is the amount of
energy required to cool or heat
a pound of water one degree
Fahrenheit.
Condenser – The unit used to
condense a substance from
a gaseous state to liquid by
cooling it. Condensers are
generally recognized as heat
exchangers. In the case of air
conditioners they extract the
inside heat from the interior of
the air conditioner to the outside
air. Often referred to as “the
outdoor unit”.
Dehumidifier – Also called
Duhums. Dehumidifiers remove
humidity and are used to keep a
rooms humidity levels in check.
Maintaining correct humidity will
ensure a healthy crop. Too much
humidity will cause molds, rot
and devastate your crop.
Digital Inverter Compressor
– A digitally controlled
compressor that converts AC
voltage to DC voltage to control
compressor speed. The inverter
allows precise throttle control of
the conditioning unit based on
the load or need. Inverter units
are quieter, more efficient and
last longer.
Ductless Mini-Split – An
air conditioner or heat pump
that requires no duct work to
function. The unit hangs on the
wall or ceiling and cools or heats
the surrounding area.
Evaporator – The indoor
portion of the heat pump or
air conditioner. In a mini-split
system this hangs on the wall or
ceiling and provides the heating
or cooling of the space.
H/P – Heat Pump. A unit that
can operate as both an air
conditioner or a heater. When
it’s cold outside a heat pump
extracts the outside heat and
transfers it inside. When it’s
warm outside, it reverses
directions and acts like an air
conditioner, removing heat. A
heat pump moves heat instead
of generating it, giving you more
energy efficiency.
HSPF – Heating Seasonal
Performance Factor. The greater
the number/rating the more
efficient the heating. A 10 HSPF,
for example is a very good
rating.
Humidifier – Humidifiers use
water to put humidity in the
growing space. Many plants we
grow indoors are accustom to
growing outdoors in tropical
areas where humidity is high.
Also certain parts of the country
are dryer than others so you will
need to add humidity.
Line Set – Insulated copper
tubing used to connect the
evaporator and condenser.
The refrigerant travels back
and forth through the line set
between the evaporator and
condenser to create either
cooling or heating.
R-410 – A type of refrigerant.
Unlike alkyl halide refrigerants,
R-410A (which contains only
fluorine) does not contribute
to ozone depletion. Because
of that attribute it’s preferred
and used more broadly instead
of R-22 which are phased out.
R-410 refrigerants allow for
higher SEER ratings therein
reducing power consumption
and improving unit efficiency.
SEER – Seasonal Energy
Efficiency Ratio. The greater
the SEER rating, the more
efficient the cooling system. The
minimum SEER rating allowed by
the Federal Government is 14.
Ton – The size of air
conditioning unit (heating or
cooling) is common referred
to in “tons”. A one ton unit, for
example, is 12,000 BTU’s. A two
ton, 24,000 BTU’s, etc. This
was arrived at using a standard
of how long it would take to
melt ice. A one ton unit takes
12,000BTU’s of heat one hour to
melt a ton of ice.
VFD – Variable Frequency Drive.
The VFD is a an electrical device
that’s used to control the speed
and torque of an air conditioning
motor, like those used in an
inverter compressor.
GLOSSERY OF TERMS

NOTES
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________

170 PINT MANUAL
#700835
All design and specifications herein are subject to change without
notice for product improvement. Contact Ideal Air for
details, updates and other information.
Contact Ideal Air Support directly
at support@ideal-air.com or call
1-877-943-3251
Product not working properly?
DO NOT return this product to the
store where you purchased it.
For answers to most common questions and a complete
technical support library please visit
www.ideal-air.com
Table of contents
Other Ideal Air Other manuals
Popular Other manuals by other brands

Trail-Gear
Trail-Gear Rock Defense 303942-1-KIT Install instructions

HID Corporation
HID Corporation MIFARE WIEGAND READER 6074A installation manual

Turner Designs
Turner Designs DataBank quick start guide

Drew Technologies
Drew Technologies CarDAQ-Plus 2 user manual

Fagor
Fagor MZ-80V manual

Dickson
Dickson SM300 operating instructions