Design and specification are subject to change without notice.
201104
Power Base Station
EB-424L
Thank you for purchasing the EB-424L Power Base Station. Prior to using the unit, IDX recommend
toread this instruction manual and keep this manual for future reference.
DC output table
LED indicator ( only for 24V output )
Safety cautions:
●Do not attempt to open or modify this unit. All work should be carried out by IDX authorized personnel only.
●Use only ENDURA Li-ion Battery.
●When connecting the battery, be sure to connect the battery firmly.
●When in use, do not place anything on top of the unit and do not block ventilation holes. Use in a well
ventilated area.
●Do not expose to use the unit in direct sunlight, extreme dust, water and other hazardous environments.
●Turn OFF the power switch for 24V output when not in use. The pilot LED may be turned OFF. The batteries
may have discharge to inside of the circuit.
●The Power base station supports up to eight batteries allowing up to 744 Wh of power when in PowerLink
configulation.
●Features uninterrupted battery changeover, low voltage warning lamp and extendable support feet. (only
for 24V output )
Features
Location of parts
Specifications
●Applicable batteries
●DC Input
●DC Output
●Output Voltage
●Number of batteries to be used
●Dimensions / Weight
All IDX ENDURA Li-ion Battery
IDX ENDURA battery – DC12 ~ 17V
8 pin LEMO connector for 12V / 24V
(Connector name: LEMO: EGG-3B-308CLL )
【12V】
Pin 1,2,8 - Negative, Pin 5,6,7 - Positive
【24V】
Pin 3 - Negative, Pin 4 – Positive
4 pin XLR connector for 12V
(Connector name: ITT Cannon: XLR-4-31-F77 )
Pin 1 - Negative, Pin 4 – Positive
【24V output】
24.2V±0.7V
【12V output】
Un-regulated
Maximum 8(ENDURA batteries that have IDX PowerLink function)
80 (W ) × 165 (H ) × 217 (D )㎜
[feet extended : 128 (W )㎜]/ Approx. 1.3㎏
3.15 (W ) × 6.50 (H ) × 8.54 (D )inches.
[feet extended : 5.04 (W )inches. ]/ Approx. 2.87lbs.
Operating instructions
①
Set the battery on to the unit.
③
24V output through the DC-OUT connector.
②
Select an output voltage of LEMO connector.Power switch allows 24V output
from LEMO connector.Turn the power switch ON, (slide the switch to right )
.
The pilot LED will be turned on.
*12V out is continuously output from LEMO and XLR connector.
④
After used, turn the Power switch OFF and release the batteries from the unit.
Fast Flashing Red
Slow Flashing Red
Solid Green Battery voltage is 14V or higher
Protection Circuit detected
LED off
Low voltage warning - Battery voltage is below 14V
Low voltage - Battery voltage is 12V or below
Instruction Manual
8 pin LEMO connector
for 12V / 24V output
4 pin XLR connector
for 12V output
Power switch
for 24V output
Pilot LED
V-Mount plate
5A Total 8A
5A Total 8A
10A
XLR 12V LEMO 12V LEMO 24V
In use
In use
In use
In use
In use
In use
In use
No use
In use
In use
In use
No use
No use No use
No use
No use
Max. current of 24V Max. current of 12V
5A Total 8A
10A
Total 20A (10A each )
In use
No use