..........................................................................................9.6...32DC
Currentrating[mA] .........................................................................................................500
Currentconsumption[mA].............................................................................................< 25
Switchingfrequency[Hz]................................................................................................100
Settingaccuracy[%oftheendvalueofthemeasuringrange] .................................< ± 2.5
Characteristicsdeviation
[%oftheendvalueofthemeasuringrange]...........................< ± 1.5 (BFSL) / < ± 2.5 (LS)
Repeatability[%oftheendvalueofthemeasuringrange].......................................< ± 0.5
Temperaturedrift[%oftheendvalueofthemeasuringrange/10K] ........................< ± 0.5
inthetemperaturerange[°C] ......................................................................................0...80
Operatingtemperatur[°C] ........................................................................................-25...80
Mediumtemperature[°C] .........................................................................................-25...80
Protection ...............................................................................................................IP67/III
Insulation resistance [M
Ω
] .......................................................................>100(500VDC)
Shock resistance [g] .............................................................. 50(DIN/IEC68-2-27,11ms)
Vibration resistance [g] ................................................ 20(DIN/IEC68-2-6,10-2000Hz)
Housingmaterial..................Pocan;PC(Macrolon);FPM(Viton);stainlesssteel(316S12)
Materials (wetted parts)....................................stainlesssteel(316S12);seal:FPM(Viton)
EMC EN61000-4-2ESD: ................................................................................. 4 / 8 KV
EN61000-4-3HFradiated:....................................................................... 10 V/m
EN61000-4-4Burst: ..................................................................................... 2 KV
EN61000-4-6HFconducted: ....................................................................... 10 V
BFSL = Best Fit Straight Line / LS = Limit Value Setting