IFM Electronic AL1303 User manual

Operating Instructions
IO-Link Master with PROFINET interface
DataLine
8 Ports
IP 65 / IP 66 / IP 67 / IP 69K
AL1303
IO-Link: 1.1.2
ifm firmware: 2.1.28 or higher
LR DEVICE: 1.3.1.x or higher
English
7391155 / 01 05 / 2018

2
ifm Operating Instructions IO-Link Master with PROFINET interface DataLine 8 Ports IP 65 / IP 66 / IP 67 / IP 69K (AL1303) 05 / 2018
Content
Table of Contents
1Preliminary note 5
1.1 Legal and copyright information...........................................................................................5
1.2 Purpose of the document.....................................................................................................5
1.3 Symbols and styles used.....................................................................................................6
1.4 Modification history ..............................................................................................................6
2Safety instructions 7
2.1 General ................................................................................................................................7
2.2 Required background knowledge ........................................................................................7
2.3 Safety symbols on the device..............................................................................................7
2.4 Tampering with the unit........................................................................................................8
3Intended use 9
3.1 Permitted use.......................................................................................................................9
3.2 Prohibited use......................................................................................................................9
4Function 10
4.1 Communication, parameter setting, evaluation .................................................................11
4.1.1 IO-Link........................................................................................................................................11
4.1.2 PROFINET.................................................................................................................................11
4.1.3 Internet of Things (IoT)...............................................................................................................11
4.1.4 Parameter setting.......................................................................................................................11
4.1.5 Visual indication .........................................................................................................................12
4.2 Digital inputs.......................................................................................................................12
4.3 IO-Link supply....................................................................................................................12
5Mounting 13
5.1 Mount the device................................................................................................................13
6Electrical connection 14
6.1 Remarks.............................................................................................................................14
6.2 PROFINET ports................................................................................................................15
6.3 IoT port...............................................................................................................................16
6.4 IO-Link ports.......................................................................................................................17
6.4.1 Input circuit.................................................................................................................................17
6.4.2 IO-Link circuits............................................................................................................................17
6.5 Connect the device ............................................................................................................18
7Operating and display elements 19
7.1 Overview............................................................................................................................19
7.2 LED indicators....................................................................................................................20
7.2.1 Status LEDs ...............................................................................................................................20
7.2.2 Ethernet interface.......................................................................................................................20
7.2.3 IoT port.......................................................................................................................................21
7.2.4 Voltage supply............................................................................................................................21
7.2.5 IO-Link ports (Class A)...............................................................................................................21

3
ifm Operating Instructions IO-Link Master with PROFINET interface DataLine 8 Ports IP 65 / IP 66 / IP 67 / IP 69K (AL1303) 05 / 2018
Content
8Configuration 22
8.1 LR DEVICE........................................................................................................................23
8.1.1 Remarks.....................................................................................................................................24
8.1.2 IoT: Configure access rights.......................................................................................................25
8.1.3 IoT: Configure IP settings...........................................................................................................26
8.1.4 IoT: Configure the interface to the LR SMARTOBSERVER.......................................................27
8.1.5 Fieldbus: Configure the PROFINET port....................................................................................28
8.1.6 IO-Link ports: Activate data transfer to the LR SMARTOBSERVER ..........................................28
8.1.7 IO-Link ports: Configure operating mode....................................................................................29
8.1.8 IO-Link ports: Set the device validation and data storage ..........................................................30
8.1.9 Firmware: Reset device to factory settings.................................................................................31
8.1.10 Firmware: Reboot the device......................................................................................................31
8.1.11 Configure IO-Link devices..........................................................................................................32
8.2 PROFINET.........................................................................................................................33
8.2.1 Install GSD file............................................................................................................................34
8.2.2 Add the IO-Link master to the PROFINET network....................................................................35
8.2.3 Configure access rights..............................................................................................................37
8.2.4 Configure IO-Link ports ..............................................................................................................38
8.2.5 Configure the PROFINET port....................................................................................................39
8.2.6 Configure IO-Link devices..........................................................................................................39
8.2.7 Read and write data cyclically....................................................................................................40
8.2.8 PROFINET: Read & write device information.............................................................................40
8.2.9 PROFINET: Programmers' notes...............................................................................................41
8.3 IoT Core.............................................................................................................................43
8.3.1 Configure IoT interface...............................................................................................................44
8.3.2 Configure the fieldbus interface..................................................................................................44
8.3.3 Configure IO-Link ports ..............................................................................................................45
8.3.4 Configure IO-Link devices..........................................................................................................45
8.3.5 Set application identification.......................................................................................................45
8.3.6 Read / write cyclic process data.................................................................................................46
8.3.7 Read diagnostic data..................................................................................................................46
8.3.8 Control IO-Link master ...............................................................................................................46
8.3.9 Read device information.............................................................................................................47
8.3.10 Read information about IO-Link devices ....................................................................................47
8.3.11 Examples....................................................................................................................................48
8.3.12 Programmers' notes...................................................................................................................52
9Operation 56
9.1 Firmware update................................................................................................................56
9.2 Web interface: Read device and diagnostic information....................................................57
9.3 Replace IO-Link device......................................................................................................58
10 Maintenance 59
11 Factory settings 60
12 Accessories 61
13 Appendix 62
13.1 Technical data....................................................................................................................63
13.1.1 Application..................................................................................................................................63
13.1.2 Electrical data.............................................................................................................................63
13.1.3 Inputs / outputs...........................................................................................................................63
13.1.4 Inputs..........................................................................................................................................64

4
ifm Operating Instructions IO-Link Master with PROFINET interface DataLine 8 Ports IP 65 / IP 66 / IP 67 / IP 69K (AL1303) 05 / 2018
Content
13.1.5 Outputs.......................................................................................................................................64
13.1.6 Interfaces....................................................................................................................................64
13.1.7 Operating conditions ..................................................................................................................65
13.1.8 Approvals / tests.........................................................................................................................65
13.1.9 Mechanical data.........................................................................................................................65
13.1.10 Electrical connection ..................................................................................................................66
13.2 PROFINET.........................................................................................................................67
13.2.1 Parameter data...........................................................................................................................67
13.2.2 Cyclic data..................................................................................................................................70
13.2.3 Acyclic data................................................................................................................................72
13.3 ifm IoT Core .......................................................................................................................75
13.3.1 Overview: IoT profile ..................................................................................................................76
13.3.2 Overview: IoT types....................................................................................................................79
13.3.3 Overview: IoT services...............................................................................................................80
14 Index 87

5
ifm Operating Instructions IO-Link Master with PROFINET interface DataLine 8 Ports IP 65 / IP 66 / IP 67 / IP 69K (AL1303) 05 / 2018
Preliminary note Legal and copyright information
1Preliminary note
Legal and copyright information ...............................................................................................................5
Purpose of the document .........................................................................................................................5
Symbols and styles used..........................................................................................................................6
Modification history...................................................................................................................................6
14801
>
1.1 Legal and copyright information
1631
© All rights reserved by ifm electronic gmbh. No part of this manual may be reproduced and used
without the consent of ifm electronic gmbh.
All product names, pictures, companies or other brands used on our pages are the property of the
respective rights owners:
AS-i is the property of the AS-International Association, (→www.as-interface.net)
CAN is the property of the CiA (CAN in Automation e.V.), Germany (→www.can-cia.org)
CODESYS™ is the property of the 3S – Smart Software Solutions GmbH, Germany
(→www.codesys.com)
DeviceNet™ is the property of the ODVA™ (Open DeviceNet Vendor Association), USA
(→www.odva.org)
EtherNet/IP® is the property of the →ODVA™
EtherCAT®is a registered trade mark and patented technology, licensed by Beckhoff Automation
GmbH, Germany
IO-Link®(→www.io-link.com) is the property of the →PROFIBUS Nutzerorganisation e.V.,
Germany
ISOBUS is the property of the AEF –Agricultural Industry Electronics Foundation e.V.,
Deutschland (→www.aef-online.org)
Microsoft®is the property of the Microsoft Corporation, USA (→www.microsoft.com)
PROFIBUS®is the property of the PROFIBUS Nutzerorganisation e.V., Germany
(→www.profibus.com)
PROFINET®is the property of the →PROFIBUS Nutzerorganisation e.V., Germany
Windows®is the property of the →Microsoft Corporation, USA
>
1.2 Purpose of the document
22044
This document is only for device types "IO-Link master - PROFINET gateway (DataLine) 8 port IP 65 /
IP 66 / IP 67 / IP 69K" (art. no.: AL1303).
It is part of the device and contains information about the correct handling of the product.
►Read this document before using the device.
►Keep this document during the service life of the device.
Table of contents
Other IFM Electronic Recording Equipment manuals

IFM Electronic
IFM Electronic Ecomat 300 AC422S Application guide

IFM Electronic
IFM Electronic ecomot 300 AC1391 Application guide

IFM Electronic
IFM Electronic AC2482 User manual

IFM Electronic
IFM Electronic AC2729 User manual

IFM Electronic
IFM Electronic AL1122 User manual

IFM Electronic
IFM Electronic AS Interface SmartLink DP AC1375 User manual