ifs MC352-4P-2S-V2 User manual

MC352-4P-2S-V2 User
Manual
P/N 1041-EN • REV B • ISS 13JUL22

Copyright
©
2022 Carrier. All rights reserved.
Specifications subject to change without
prior notice
.
This document may not be copied in whole or in part or otherwise
reproduced without prior written consent from
Carrier, except where
specifically permitted under US and international copyright law.
Trademarks and
patents
IFS
names and logos are a product brand of Aritech, a part of Carrier.
Other trade names used in this document may be trademarks or registered
trademarks of the manufacturers or vendors of the respective products.
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd, Palm Beac
h Gardens, FL 33418, USA
AUTHORIZED EU REPRENSENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
FCC compliance
Class A
: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursu
ant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy
and,
if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required
to correct the interference at his own
expense.
FCC conditions
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference.
(2) This Device must accept any interference received, including
interference that may cause unde
sired operation.
ACMA compliance
Notice!
This is a Class A product. In a domestic environment this product
may cause radio interference in which case the user may be required to
take adequate measures.
Product warnings and
disclaimers
THESE
PRODUCTS ARE INTENDED FOR SALE TO AND
INSTALLATION BY QUALIFIED PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON
OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED
DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAIN
ED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and product safety
information, please check https://firesecurityproducts.com/policy/product
-
warning/ or scan the following code:
Certification
EU directives
This product and
- if applicable - the supplied accessories too are marked
with "CE" and comply therefore with the applicable harmonized European
standards listed under the EMC Directive 2014/30/EU, the RoHS Direc
tive
2011/65/EU.

2012/19/EU (WEEE directive):
Products marked with this symbol cannot
be disposed of as unsorted municipal waste in the European Union. For
proper recycling, return this product to your local supplier upon the
purchase of equivalent new
equipment, or dispose of it at designated
collection points. For more information see: www.recyclethis.info.
2013/56/EU & 2006/66/EC (battery directive
): This product contains a
battery that cannot be disposed of as unsorted municipal waste in the
European Union. See the product documentation for specific battery
information. The battery is marked with this symbol, which may include
lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the battery to your suppl
ier or to a designated collection
point. For more information see: www.recyclethis.info.
Contact information
EMEA:
https://firesecurityproducts.com
Australian/New Zealand:
https://firesecurityproducts.com.au/
Product
documentation
Please consult the following web link to retrieve the electronic version of the
product documentation.
The manuals are available in several languages.


MC352-4P-2S-V2 User Manual 1
Content
Important information 2
Regulatory information 2
Limitation of liability 2
Product Warnings 2
Warranty Disclaimers 3
Intended Use 4
Advisory messages 4
Package contents 5
Hardware Introduction 6
Switch Front Panel 6
LED Definition 8
Switch Upper Panel 9
Wiring the Power Inputs 9
Wiring the Faulty Alarm Contact 10
Grounding the Device 10
Installation 12
Mounting the DIN rail 12
Mounting the Wall-mount Plate 13
Product specifications 14
Customer Support 15

2 MC352-4P-2S-V2 User Manual
Important information
Regulatory information
Limitation of liability
To the maximum extent permitted by applicable law, in no event will Carrier be liable for
any lost profits or business opportunities, loss of use, business interruption, loss of
data, or any other indirect, special, incidental, or consequential damages under any
theory of liability, whether based in contract, tort, negligence, product liability, or
otherwise. Because some jurisdictions do not allow the exclusion or limitation of liability
for consequential or incidental damages the preceding limitation may not apply to you.
In any event the total liability of Carrier shall not exceed the purchase price of the
product. The foregoing limitation will apply to the maximum extent permitted by
applicable law, regardless of whether Carrier has been advised of the possibility of such
damages and regardless of whether any remedy fails of its essential purpose.
Installation in accordance with this manual, applicable codes, and the instructions of the
authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to ensure
the accuracy of its contents, Carrier assumes no responsibility for errors or omissions.
Product Warnings
YOU UNDERSTAND THAT A PROPERLY INSTALLED AND MAINTAINED
ALARM/SECURITY SYSTEM MAY ONLY REDUCE THE RISK OF EVENTS SUCH AS
BURGLARY, ROBBERY, FIRE, OR SIMILAR EVENTS WITHOUT WARNING, BUT IT
IS NOT INSURANCE OR A GUARANTEE THAT SUCH EVENTS WILL NOT OCCUR
OR THAT THERE WILL BE NO DEATH, PERSONAL INJURY, AND/OR PROPERTY
DAMAGE AS A RESULT.
THE ABILITY OF CARRIER PRODUCTS, SOFTWARE OR SERVICES TO WORK
PROPERLY DEPENDS ON A NUMBER OF PRODUCTS AND SERVICES MADE
AVAILABLE BY THIRD PARTIES OVER WHICH CARRIER HAS NO CONTROL AND
FOR WHICH CARRIER SHALL NOT BE RESPONSIBLE INCLUDING, BUT NOT
LIMITED TO, INTERNET, CELLULAR AND LANDLINE CONNECTIVITY; MOBILE
DEVICE AND OPERATING SYSTEM COMPATIBILITY; MONITORING SERVICES;
ELECTROMAGNETIC OR OTHER INTERFERENCE, AND PROPER INSTALLATION
AND MAINTENANCE OF AUTHORIZED PRODUCTS (INCLUDING ALARM OR
OTHER CONTROL PANEL AND SENSORS).
ANY PRODUCT, SOFTWARE, SERVICE OR OTHER OFFERING MANUFACTURED,
SOLD OR LICENSED BY CARRIER, MAY BE HACKED, COMPROMISED AND/OR
CIRCUMVENTED AND CARRIER MAKES NO REPRESENTATION, WARRANTY,
COVENANT OR PROMISE THAT ITS PRODUCTS (INCLUDING SECURITY
PRODUCTS), SOFTWARE, SERVICES OR OTHER OFFERINGS WILL NOT BE
HACKED, COMPROMISED AND/OR CIRCUMVENTED.

MC352-4P-2S-V2 User Manual 3
CARRIER DOES NOT ENCRYPT COMMUNICATIONS BETWEEN ITS ALARM OR
OTHER CONTROL PANELS AND THEIR WIRELESS OUTPUTS/INPUTS INCLUDING
BUT NOT LIMITED TO, SENSORS OR DETECTORS UNLESS REQUIRED BY
APPLICABLE LAW. AS A RESULT THESE COMMUNICATIONS MAY BE
INTERCEPTED AND COULD BE USED TO CIRCUMVENT YOUR ALARM/SECURITY
SYSTEM.
THE EQUIPMENT SHOULD ONLY BE OPERATED WITH AN APPROVED POWER
ADAPTER WITH INSULATED LIVE PINS.
DO NOT CONNECT TO A RECEPTACLE CONTROLLED BY A SWITCH.
THIS UNIT INCLUDES AN ALARM VERIFICATION FEATURE THAT WILL RESULT
IN A DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED CIRCUITS.
THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS) SHALL NOT
EXCEED 60 SECONDS. NO OTHER SMOKE DETECTOR SHALL BE CONNECTED
TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING
JURISDICTION.
WARNING! The equipment should only be operated with an approved power adapter
with insulated live pins.
Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of
batteries according to the instructions. Contact your supplier for replacement batteries.
Warranty Disclaimers
CARRIER HEREBY DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS,
WHETHER EXPRESS, IMPLIED, STATUTORY OR OTHERWISE, INCLUDING ANY
IMPLIED WARRANTIES, THE WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE.
(USA only) SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED
WARRANTIES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. YOU MAY
ALSO HAVE OTHER LEGAL RIGHTS THAT VARY FROM STATE TO STATE.
CARRIER DOES NOT MAKE ANY CLAIMS OR WARRANTIES TO YOU OF ANY
KIND REGARDING ANY PRODUCT, SOFTWARE OR SERVICE’S POTENTIAL,
ABILITY, OR EFFECTIVENESS TO DETECT, MINIMIZE, OR IN ANYWAY PREVENT
DEATH, PERSONAL INJURY, PROPERTY DAMAGE, OR LOSS OF ANY KIND
WHATSOEVER.
CARRIER DOES NOT REPRESENT TO YOU THAT ANY PRODUCT (INCLUDING
SECURITY PRODUCTS), SOFTWARE, SERVICE OR OTHER OFFERING MAY NOT
BE HACKED, COMPROMISED AND/OR CIRCUMVENTED.
CARRIER DOES NOT WARRANT THAT ANY PRODUCT (INCLUDING SECURITY
PRODUCTS), SOFTWARE OR SERVICE MANUFACTURED, SOLD OR LICENSED
BY CARRIER WILL PREVENT, OR IN ALL CASES PROVIDE ADEQUATE WARNING

4 MC352-4P-2S-V2 User Manual
OF OR PROTECTION FROM, BREAK-INS, BURGLARY, ROBBERY, FIRE, OR
OTHERWISE.
CARRIER DOES NOT WARRANT TO YOU THAT ITS SOFTWARE OR PRODUCTS
WILL WORK PROPERLY IN ALL ENVIRONMENTS AND APPLICATIONS AND DOES
NOT WARRANT ANY PRODUCTS AGAINST HARMFUL ELECTROMAGNETIC
INTERFERENCE INDUCTION OR RADIATION (EMI, RFI, ETC.) EMITTED FROM
EXTERNAL SOURCES
CARRIER DOES NOT PROVIDE MONITORING SERVICES FOR YOUR
ALARM/SECURITY SYSTEM (“MONITORING SERVICES”). IF YOU ELECT TO HAVE
MONITORING SERVICES YOU MUST OBTAIN SUCH SERVICE FROM A THIRD
PARTY AND CARRIER MAKES NO REPRESENTATION OR WARRANTY WITH
RESPECT TO SUCH SERVICES INCLUDING WHETHER OR NOT THEY WILL BE
COMPATIBLE WITH THE PRODUCTS, SOFTWARE OR SERVICES
MANUFACTURED, SOLD OR LICENSED BY CARRIER.
Intended Use
Use this product only for the purpose it was designed for; refer to the data sheet and
user documentation. For the latest product information, contact your local supplier or
visit us online at firesecurityproducts.com.
The system should be checked by a qualified technician at least every 3 years and the
backup battery replaced as required.
Advisory messages
Advisory messages alert you to conditions or practices that can cause unwanted
results. The advisory messages used in this document are shown and described below.
WARNING: Warning messages advise you of hazards that could result in injury or loss
of life. They tell you which actions to take or to avoid in order to prevent the injury or
loss of life.
Caution: Caution messages advise you of possible equipment damage. They tell you
which actions to take or to avoid in order to prevent the damage.
Note: Note messages advise you of the possible loss of time or effort. They describe
how to avoid the loss. Notes are also used to point out important information that you
should read.

MC352-4P-2S-V2 User Manual 5
Package contents
Thank you for purchasing the IFS Industrial 4-Port 10/100/1000T 802.3at PoE + 2-Port
100/1000X SFP Ethernet Switch, MC352-4P-2S-V2. In the following sections, the term
“Industrial Gigabit PoE+ Switch”means the MC352-4P-2S-V2.
Open the box of the Industrial Gigabit PoE+ Switch and carefully unpack it. The box
should contain the following items:
•Industrial Gigabit PoE+ Switch x 1
•User Manual x 1
•DIN Rail Kit x 1
•Wall Mount Kit x 1
If any of these are missing or damaged, please contact your dealer immediately. If
possible, retain the carton including the original packing material, and use them again
to repack the product in case there is a need to return it to us for repair.

6MC352-4P-2S-V2 User Manual
Hardware Introduction
Switch Front Panel
The front panel of the Industrial Gigabit PoE+ Switch consists of Ethernet interfaces
and LED indicators.
Front View
Figure 1: MC352-4P-2S-V2 Front View
PoE Power Usage LED
The front panel of the Industrial Gigabit PoE+ Switch has four LEDs that indicate PoE
Power Usagesof 30W, 60W, 90W and 120W. With these LED indications, you can
monitor the current PoE power in use status of Industrial Gigabit PoE+ Switch easily
and efficiently.

MC352-4P-2S-V2 User Manual 7
DIP Switch
The front panel of the Industrial Gigabit PoE+ Switch provides one DIP Switch for
configuring fiber redundant function.
The DIP Switch settings and descriptions:
Fiber Mode (DIP Switch)
Switch (Default Mode) This mode allows the Industrial Gigabit
PoE+ Switch to use 6 ports.
Redundant This mode allows one of the two SFP
ports to be redundant while the other 5
ports are in operation.
Redundancy Overview
The Industrial Gigabit PoE+ Switch provides rapid link fiber redundancy for critical
Ethernet applications;the redundant mode supports auto-recover function. If the link of
the destination port of a packet is down, it will forward the packet to the other port of the
backup pair. The following figure shows the redundant functions.
Figure 2: Redundancy Behavior Topology
Note: Using the Redundant mode, port 5 is defined as Primary Port and port 6 as
Backup Port.

8MC352-4P-2S-V2 User Manual
LED Definition
System
LED Color Function
P1 Green Light: indicates power 1 has power.
P2 Green Light: indicates power 2 has power.
FAULT Red Light: indicates either power 1 or power 2 has no power.
10/100/1000BASE-T Interfaces (Port 1 to Port 4)
LED Color Function
LNK/ACT Green
Light: Indicates the Industrial Gigabit PoE+ Switch is successfully
connecting to the network at 10/100/1000Mbps.
Blinking: Indicates that the Industrial Gigabit PoE+ Switch is
actively sending or receiving data over that port.
PoE-in-Use
Amber
Light: Indicates the port is providing DC in-line power.
Off: Indicates the connected device is not a PoE powered device
(PD).
SFP Interface (Port 5 to Port 6)
LED Color Function
1000
LNK/ACT Green
Light Indicates the port is running at 1000 Mbps and successfully
established.
Blinking Indicates that the Industrial Gigabit PoE+ Switch is actively
sending or receiving data over that port.
100
LNK/ACT Amber Light Indicates the port is running at 100 Mbps and successfully
established.
Per PoE Power Usage (Unit: Watt) (Lower LED to upper LED)
LED Color Function
30
Amber
Light: Indicates the system is providing >30/60/90/120W PoE power
usage.
Blinking: Indicates the system is providing 30/60/90/120W PoE
power usage.
25 < X < 30, 30W LED flash; X >= 30, 30W LED light;
55 < X < 60, 60W LED flash; X >= 60, 60W LED light;
85 < X < 90, 90W LED flash; X >= 90, 90W LED light;
100 < X < 115, 120W LED flash;
115 < X < 120, 120W LED flash fast; X >= 120, 120W LED light.
60
90
120

MC352-4P-2S-V2 User Manual 9
Switch Upper Panel
The upper panel of the Industrial Gigabit PoE+ Switch consists of one terminal block
connector within two DC power inputs. Figure 3 shows the upper panel of the Industrial
Gigabit PoE+ Switch.
Figure 3: Industrial Gigabit PoE Switch Upper Panel
Wiring the Power Inputs
The six-contact terminal block connector on the top panel of Industrial Gigabit PoE+
Switch is used for two redundant power inputs. Please follow the steps below to insert
the power wire.
Caution: When performing any of the procedures like inserting the wires or tightening
the wire-clamp screws, make sure the power is OFF to prevent from getting an electric
shock.
To insert the power wire:
1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1, or
contacts 5 and 6 for POWER 2.
V1+ V1- V2+ V2-
2. Tighten the wire-clamp screws for preventing the wires from loosening.

10 MC352-4P-2S-V2 User Manual
1 2 3 4 5 6
Power 1 Fault Power 2
+- +-
Note: The wire gauge for the terminal block should be in the range between 12 and 24
AWG.
Wiring the Faulty Alarm Contact
The faulty alarm contacts are in the middle of the terminal block connector as the
picture shows below. Inserting the wires, the Industrial Gigabit PoE+ Switch will detect
the fault status of the power failure and then forms an open circuit. The following
illustration shows an application example for wiring the faulty alarm contacts.
Note:
1. The wire gauge for the terminal block should be in the range of 12 ~ 24 AWG.
2. Alarm relay circuit accepts up to 24 V, max. 1 A currents.
Grounding the Device
The device must be correctly grounded to avoid serious damage.
Insert the wires into the fault alarm contacts

MC352-4P-2S-V2 User Manual 11
Note: EMD (Lightning) DAMAGE IS NOT CONVERED UNDER WARRANTY.

12 MC352-4P-2S-V2 User Manual
Installation
This section describes how to install the Industrial PoE+ Switch on the DIN rail and
wall.
Note: The following pictures show how to install the device. However, the device in the
picture is not MC352-4P-2S-V2.
Mounting the DIN rail
The DIN rail bracket is screwed on the Industrial PoE+ Switch when shipped. You need
an Industrial PoE+ Switch when replacing the wall-mount application with DIN rail
application.
To mount the Industrial PoE+ Switch:
1. Screw the DIN rail bracket on the Industrial PoE+ Switch.
2. Carefully insert the bottom of the switch into the track, as shown below.
3. Ensure the DIN rail bracket is tightly secured on the track.

MC352-4P-2S-V2 User Manual 13
4. Please refer to the following procedure to remove the Industrial PoE+ Switch from
the track.
Mounting the Wall-mount Plate
To install the Industrial PoE+ Switch on the wall:
1. Loosen the screws to remove the DIN rail bracket from the Industrial PoE+ Switch.
2. Place the wall-mount plate on the rear panel of the Industrial PoE+ Switch.
3. Use the screws to attach the wall-mount plate on the Industrial PoE+ Switch.
4. Use the hook holes at the corners of the wall-mount plate to hang the Industrial
PoE+ Switch on the wall.
5. To remove the wall-mount plate, reverse the steps above.

14 MC352-4P-2S-V2 User Manual
Product specifications
This section describes the functionalities of the Industrial Gigabit PoE+ Switch’s components and guides
you to installing the Switch.
Model
MC352
-4P-2S-V2
Hardware Specifications
Copper Ports
4 10/100/1000
BASE-T RJ45 auto-MDI/MDI-X ports
PoE Injector Ports
Four ports with 802.3at PoE+ injector function (Port
-1 to Port-4)
SFP Slots (Auto Detection)
Two 1000BASE
-SX/LX/BX SFP interface (Port 5 to Port 6)
Compatible with 100BASE
-FX SFP
DIP Switch
Switch (default)/fiber redundant mode
Connector
Removable 6
-pin terminal block
Pin 1/2 for Power 1
Pin 3/4 for fault alarm
Pin 5/6 for Power 2
Power Requirements
12
to 56 VDC, 7A (max.)
R
edundant power with reverse polarity protection
Alarm
Provides one relay output for power failure
Alarm relay current carry ability: 1
A @ 24 VDC
Power Consumption
Max. 7.02
W/24 BTU
(Ethernet Full Loading)
Max. 130.6
W/445 BTU
(Ethernet + PoE Full
Loading)
Dimensions
(W x D x H)
32 x 87 x 135 mm
Weight
657
g
Enclosure
IP40
metal case
Installation
DIN rail
kit and wall-mount kit
ESD Protection
6
KV
Switch Specifications
Switch Architecture
Store
-and-Forward
Switch Fabric
12
Gbps
Throughput
(packet per second)
8.93
Mpps @ 64 bytes
Address Table
4
K entries
Buffer Memory
1
M bits on-chip buffer memory
Jumbo Frame
9
Kbytes
Flow Control
Back pressure for half duplex
IEEE 802.3x
pause frame for full duplex

MC352-4P-2S-V2 User Manual 15
Power over Ethernet
PoE Standard
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus PSE
PoE Power Supply Type
End
-span
Power Pin Assignment
1/2(+), 3/6(
-)
PoE Power Output
IEEE 802.3af Standard
-
Per port 48 V to 51 VDC (depending on the power supply), max. 15.4 W
IEEE 802.3at Standard
-
Per port 51 V to 56 VDC (depending on the power supply), max. 36 W
PoE Power Budget (max.)
60
W@ 12 VDC input
90
W@ 24 VDC input
120
W@ 48 V to -56 VDC input
Max. Number of Class 4 PDs
4
Standards Conformance
Regulatory Compliance
FCC Part 15 Class A, CE
Stability Testing
IEC
60068-2-32 (free fall)
IEC
60068-2-27 (shock)
IEC
60068-2-6(vibration)
Standards Compliance
IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3ab
Gigabit Ethernet
IEEE 802.3az Gigabit SX/LX
IEEE 802.3x
Full-Duplex Flow Control
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus PSE
IEEE 802.1p Class of Service
Environment
Temperature
Operating:
-40 to +75°C
Storage:
-40 to +75°C
Humidity (non-condensing)
Operating: 5
to 90%
Storage: 5
to 90%
Customer Support
If you need support information, please contact our support team, whose contact details
can be found on our website:
EMEA: https://firesecurityproducts.com
Australian/New Zealand: https://firesecurityproducts.com.au/
Table of contents
Other ifs Network Hardware manuals
Popular Network Hardware manuals by other brands

Ubiquiti
Ubiquiti Nano G quick start guide

Juniper
Juniper WX 15 quick start

HMS Networks
HMS Networks Anybus Terminator T1 installation manual

Fortinet
Fortinet FortiGate 2600F-DC quick start guide

FieldServer
FieldServer FS-8700-03 DF1 Driver manual

Supermicro
Supermicro SuperServer SSG-621E-ACR12H user manual