iGear iG-1017 User manual

Eco-Friendly
Non-Toxic
Electro
Sanitize
Self-Making Non-Toxic
Disinfector
G
E
R
M
S
99.9%
K
I
L
L
S
Before using your product for first time, please read this instruction manual.
Model No.: iG-1017

Dear customer
Thank you for purchasing our electrolytic disinfectant generator
(sodium hypochlorite generator).
Before you install and use the machine, we suggest that you
read this manual in detail and accept our suggestions. It can
help you use the product safely, normatively and reasonably, so
as to maximize the performance.
If you have any questions regarding the usage process, please
contact us and we welcome your valuable opinions of our
products and services.
Warm prompt:
1. With the continuous upgrade of products, some text or
patterns on the manual may be different from the actual ones.
Please refer to the actual product.
2. All the contents in this manual have been carefully checked. If
there are any misprint or misunderstandings in the content, the
company reserves the right to explain.
Catalogue 1
Product description 02
Product parameters 03
Method of use 03
Component description 04
Function of disinfectant 04
Daily maintenance 05
Safety precautions 06
About the warranty 07

The electrolytic disinfectant generator developed and produced by our
company uses microcomputer control and uses normal tap water + salt as
raw materials to quickly and easily manufacture efficient, broad-spectrum,
safe and non-toxic sodium hypochlorite disinfectant, which can be used
disinfecting clothing, food items, housing and effective disinfection in various
other aspects as it is safe, environmentally friendly, non-toxic. It has no side
effects, and economical. It is a security guard who protects health. In general
use, the effective chlorine concentration used to disinfect different objects
has different requirements, see the following table for details:
2Product description
General
goods
surface
Use Scope Use Scope
Air
Drinking
Utensils
Allowable
concentration
(in terms of available
chlorine content, mg/L)
Fruit and
vegetable
Fabric
Operating
hours
(Min)
Wipe, soak, rinse and disinfect the
surface of all kinds of cleaning goods
Wipe, soak and spray disinfection of
all types of non-cleaning goods. The
amount of spray is measured by the
degree of spray.
Put the disinfectant into the
watering can, spray disinfectant on
the required space, which kills
bacteria and other Micro-organisms
in the air and prevent the spread of
infectious disease such as cold and
skin diseases
The equipment after cleaning, shall
be immersed and disinfected. After
disinfection, the residual
disinfectant shall be rinsed clean.
Contaminated equipment: After use
on patients with infectious diseases,
it is used to remove residue, clean
and then immerse and disinfect.
After disinfection, the residual
disinfectant should be rinsed clean.
Contaminated devices: After use on
patients with infectious diseases, it is
used to remove residue, clean and
then immerse and disinfect. After
disinfection, the residual disinfectant
should be rinsed clean.
Spray the disinfectant on fruits and
vegetables first, the remove the
residual disinfectant with drinking
water.
When sterilizing, immerse the fabric
completely into the disinfectant.
After disinfection, rinse the residual
disinfectant with water.
100~250
400~700
500~1000
250
400
500~800
100~200
250~400 20
5~10
30
20
>5
10-~30
10-~30
10-~30

Method of Use
1. Check and make sure there is no foreign object in the bottle.
2. Take a tablespoon of salt and put it in the bottle.
3. Add clean water to the bottle upto the highest indicated water
level, shake the bottle to completely dissolve the salt in the water.
4. Connect the power cord to the charging plug of 5V 1A, then
plug the machine into the power hole and plug it into the power
socket.
5. Press the power button in the middle of the base and the
buzzer will sound once. At this time. the color light on the
bottom can be observed and the color can be changed.
6. After reaching the end of working time of 6 minutes, the
machine will stop working automatically. At this time, the buzzer
will sound 3 times, indicating that the disinfectant is ready for
use.
7. Unplug the power cord from the device and use the sanitizer
correctly for its intended use.
8. After emptying the bottle, rinse it with water and let it dry for
next time.
9. Do not tighten the nozzle while the machine is working
because the machine will produce gas pressure.
3Product description
Product Name
Product Model
Supply Voltage
Product working time
Material
Capacity
Product Size
Electro Sanitize
iG - 1017
AC220V/DC5V1A
6 minutes
PC+PEGT+PP
300ml
245*90*67mm

This electrolytic disinfectant generator can produce Sodium
Hypochlorite Solution. Sodium Hypochlorite Solution is widely
used, but this manual only lists a part of its application.
Sodium hypochlorite disinfectant is one of the most effective
and powerful broad-spectrum fungicide in the world, and have
been widely used for a long time. It can effectively kill all kinds
of bacteria and viruses; it can effectively prevent hepatitis,
influenza and other diseases. Not only that, it also has the
function of degrading many kinds of harmful chemicals, such as
effectively degrading the pesticide residues on vegetables and
fruits. It is effective against a wide variety of pests such as the
mold that produces Aflatoxin and has a strong cleaning,
bleaching, decontamination, deodorization function. Therefore,
sodium hypochlorite is not only used in the family, but widely
used in many fields of sterilization, disinfection, remove algae,
deodorization, etc.
4Product description
Function of disinfectant

5
1. After each use of the machine, the disinfectant in the bottle
shall be removed and the bottle shall be cleaned with clear
water and dried in a dry and ventilated place to prolong the
working life.
2. When it is found that there is a significant reduction of
bubbles in the working process of electrolytic cell, dirt may be
generated on the electrode. After cleaning the bottle, pour
vinegar or lemon juice in it for 1-2 hours, shake it for two
minutes, pour it out, wash it with water, and then dry it in a dry
and ventilated place.
Daily maintenance
Warning: Do not drink disinfectant solution!
Disinfection solution is recommend
to be made and used immediately

6
To avoid possible harm to you or others and damage to property,
please pay attention to the following safety instructions.
The instruction manual is a guiding document for the correct use
of this product. Users should strictly follow the requirements of
this manual for operation, daily inspection and maintenance.
1. When the product fails, please cut off the power immediately.
2. Do not touch the power plug with wet hands to avoid electric
shock.
3. If there is any unused disinfectant, it should be kept out of the
reach of children and protected from light.
4. Sodium hypochlorite disinfectant has an oxidizing effect on
metal. Do not use metal utensils to store disinfectant. If the metal
utensils are directly disinfected, they should be rinsed with water
immediately after disinfection and wiped clean in time.
5. Do not drink disinfectant solution.
6. Disinfectant has a bleaching effect on the fabric. Use it with
caution in colored or dark clothes. Do not soak silk or leather.
7. After the machine is plugged in, please do not touch the water
in the machine.
8. After the completion of the disinfection process, dispose of the
remaining disinfectant in time, then clean the bottle with water
and dry it to extend the working life.
9. Do not add salt water to the equipment for a long time without
working, and do not store the electrolytic sodium hypochlorite
disinfectant in the equipment for a long time to extend the
working life.
10. In order to ensure the best use of the machine continuous
and uninterrupted work of the equipment is prohibited. After
each interval, the use period of at-least 5 minutes is guaranteed.
11. The company will not bear any responsibility for the
consequences caused by not following the above precautions.
Safety Precautions

7
1. From the date of purchase, the electrical equipment is guaranteed for one
year(wearing parts are not included), and maintenance fee is exempted
during the warranty period.
2. Purchase certificate and warranty card are required for repair within the
warranty period. If the machine belongs to normal consumables after use,
the customer shall be responsible for the expenses.
3. Within the warranty period, the consumers are prohibited to open,
disassemble or repair the product, if it is disassembled or repaired, then the
warranty gets void immediately, but it can be serviced which will be on
chargeable basis.
Maintenance center:
Add: iGear Tech Pvt. Ltd., 204, Sai Corporate Park, Laxmi Nagar, Off Link
Road, Goregaon West, Mumbai - 400104. Tel: 1800 22 8495(Toll free)
1. Please keep this card and contact our service center with this card and bill.
2. If there is any change of address and telephone, Please inform the special
maintenance center.
About the warranty
Warranty Card (with customer)
The user name
Address of the user
Purchase date
Product name and model
The user signature
The user name
Address of the user
Purchase date
Product name and model
The user signature
Please cut along this dotted line
Table of contents