Ikegami OCP-399 User manual

AUTOTALLY
LENS EXT
FREE
KNOB
RANGE SENS
IRIS
OPEN
FULL ±1±2
OPEN SHORT
CABLE
ALARM
CALL
IRIS
PED
ENCR
GY
B RGB
MON SEL
CLS
LOCKKNEE
AUTO
SAT
COLOR
DTL
SKIN
DTL
SOFT
DTL SKIN C.SAT GAMMA
KNEE PT. SLOPE
GAIN
BLACK
FLARE
MASTER
FLARECLR
FILTER
EDCBA54321
HEAD
ND CC EFF
SCENE FILE
STORE
3
7
4
8
1
5
2
6
SHUTTER SUPER V
ON VAR. GAMMA
GAIN(dB)
GAMMA
BLK
1000 +1254
.
MATCH
COLOR
MASTER /PAGE
PM IND
LEVEL SKIN HUE QUICK START AWB ABB
AUTO SETUP
CAP BARS CAL CORR
COLOR
MODE SWITCH
KNEE
SUPER
MATRIX
123 L HM
BLK STRETCH
OFFOFF
PANEL
ENABLEPOWER
VF
POWER
HEAD
CAM
POWER
OFF
-11 -7 -3 +3 +7 +11
ON
EFF1 EFF2
CUSTOM COLOR
(%)
0
PED
HOLD MENU
OPERATION CONTROL PANEL
OCP-399
OPERATION MANUAL

0403 1st Edition (U) (E)
OPERATION CONTROL PANEL
OCP-399
OPERATION MANUAL
AUTOTALLY
LENS EXT
FREE
KNOB
RANGE SENS
IRIS
OPEN
FULL ±1±2
OPEN SHORT
CABLE
ALARM
CALL
IRIS
PED
ENCR
GY
B RGB
MON SEL
CLS
LOCKKNEE
AUTO
SAT
COLOR
DTL
SKIN
DTL
SOFT
DTL SKIN C.SAT GAMMA
KNEE PT. SLOPE
GAIN
BLACK
FLARE
MASTER
FLARECLR
FILTER
EDCBA54321
HEAD
ND CC EFF
SCENE FILE
STORE
3
7
4
8
1
5
2
6
SHUTTER SUPER V
ON VAR. GAMMA
GAIN(dB)
GAMMA
BLK
1000 +1254
.
MATCH
COLOR
MASTER /PAGE
PM IND
LEVEL SKIN HUE QUICK START AWB ABB
AUTO SETUP
CAP BARS CAL CORR
COLOR
MODE SWITCH
KNEE
SUPER
MATRIX
123 L HM
BLK STRETCH
OFFOFF
PANEL
ENABLEPOWER
VF
POWER
HEAD
CAM
POWER
OFF
-11 -7 -3 +3 +7 +11
ON
EFF1 EFF2
CUSTOM COLOR
(%)
0
PED
HOLD MENU

Copyright © 2004 Ikegami Tsushinki Co., Ltd.
Copyright © 2004 Ikegami Tsushinki Co., Ltd.
We reserve the copyright on the software we create.
We reserve the copyright on the software we create.
No part of this publication may be modified or reproduced in any form, or by any means, without prior written permission from Ikegami
No part of this publication may be modified or reproduced in any form, or by any means, without prior written permission from Ikegami
Tsushinki Co., Ltd.
Tsushinki Co., Ltd.

SAFETY PRECAUTIONS
The safety precautions for using this product are described below. Please read them thoroughly before use.
1. Safety Alert Symbols
This manual employs the following "Safety Alert Symbols" to call attention to hazards:
WARNING
㪑㩷㩷 㩷
Indicates that mishandling of the product may lead to a danger resulting in a serious injury or
death.
CAUTION
: Indicates that mishandling of the product may lead to a danger resulting in an injury or
property damage.
2. Handling Precautions
This product is designed with safety in mind; however, any electrical equipment may cause electric shock or equipment
damage if used in an inappropriate manner or under unsuitable conditions.
Therefore, please follow the following instructions when handling this product:
(1) Do not remove the covers or disassemble unless absolutely necessary, to prevent malfunction or electric shock.
(2) Do not drop or expose the equipment to a strong vibration or shock.
A strong vibration or shock may cause equipment damage or failure.
(3) Be sure to turn OFF the power switch before removing modules.
(4) Avoid using or storing in the following conditions. It may cause damage to the product.
- Extremely high/low temperature
- High humidity or dusty
- Exposed to water or other liquid
- Strong vibration or shock
- Strong magnetic field or radio waves
- lightning
- In rain or snow without the cover
(5) When carrying or storing the product, always use a carrying case.
(6) Be sure to hold the plug and pull when disconnecting the cable. Failure to do so may cause a fire or electric shock due to
a broken cable.
(7) Do not drop or insert metal objects such as clips or foreign objects into the equipment.
(8) Do not spread or spill water or other liquid on the equipment.
(9) Regarding the lithium battery
- Do not use an unspecified battery.
- Wrong usage of batteries may cause liquid leak, explosion, and heat, and at worst injury or fire. When replacing or dis-
carding a battery, please contact Ikegami's sales and service centers.
3. Regular Maintenance Recommended
This product includes parts that wear out and have a limited life even in proper use or storage. Therefore, regular
maintenance (once every 3 years or 8000 hours use) is recommended to extend the life and safe use of this product for a
long time. Please contact Ikegami's sales and service centers or Techno Ikegami Co., Ltd. for the regular maintenance and
repair of our products.
SAFETY PRECAUTIONS i
OCP-399 0403 VOL1 (U) (E) OCP-399

HOW TO USE OPERATION MANUAL
The OCP-399 OPERATION CONTROL PANEL OPERATION MANUAL is intended to describe how to operate the OCP-399.
This manual is written for readers with a basic knowledge of handling broadcast cameras and Base Station (BS), so technical terms
are not explained here.
This manual consists of five chapters. Related topics are included in the same chapter as much as possible so that you do not have to
turn pages back and forth.
Each chapter is arranged in the order of actual operating procedures. By reading it in sequence, you can smoothly perform a series
of steps, from installation and connection to operation in a proper manner.
[Structure of Operation Manual]
1. NAME and FUNCTION : Explains the name and function of each switch and control on the
OCP-399.
2. INSTALLATION and CONNECTION :
Explains how to connect the OCP-399 to the camera or BS. Also explains
the specifications of connector pins.
3. OPERATION :
Explains how to turn on power, how to check operation, and how to
activate various functions.
4. TROUBLESHOOTING : Explains self-diagnosis function.
5. SPECIFICATIONS :
Lists the specifications and external dimensions of the OCP-399.
[Symbols]
The symbols used in this manual are as follows:
Note: Supplementary information on the matter just discussed
Reference: Sections or pages where related information is available
[Reference Manuals]
- HK-399PW COLOR CAMERA MAINTENANCE MANUAL
- HK-399PW COLOR CAMERA OPERATION MANUAL
- BS-388 BASE STATION INSTRUCTION MANUAL
ii HOW TO USE OPERATION MANUAL
OCP-399 OCP-399 0403 VOL1 (U) (E)

OCP-399 0403 VOL1 (U) (E) OCP-399
CONTENTS iii
OCP-399
OPERATION CONTROL PANEL
OPERATION MANUAL
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
HOW TO USE OPERATION MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ii
1. NAME and FUNCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
2. INSTALLATION and CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1 Cable Connection Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2 OCP Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.3 Connector Pin Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
3. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1 Turning ON Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.1 BS-388 for Non-EU Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.2 BS-388 for EU Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2 Operation Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.2.1 Checking Color Bars Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.2.2 Checking with Test Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.2.3 Checking Images on Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.3 Auto Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.3.1 Quick Auto Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3.3.2 Auto Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
3.3.3 AWB (Auto White Balance) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
3.3.4 ABB (Auto Black Balance) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3.4 Operation Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
3.4.1 Selecting Shutter Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
3.4.2 Improving Reproducibility of Low Luminance Level Part (Black Press/Black Stretch) . . . . . . . . . . . . 3-10
3.4.3 Suppressing Glare on the Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3.4.4 Correcting Color Temperature for Multiple Cameras (Color Matching) . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.4.5 Creating Scene Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
3.5 Menu Remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
3.6 Internal Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
4. TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.1 Alarm Lamp Flashes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

OCP-399 OCP-399 0403 VOL1 (U) (E)
iv CONTENTS
5. SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.1 Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2 Control Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.3 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.4 External Dimensions Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3

1. NAME and FUNCTION
The diagrams below show the locations of switches and connectors.
Note:
The switches and VR controls on the OCP do not work if the connected camera does not have corresponding functions.
Refer to the manual for the connected camera for available functions.
AUTOTALLY
LENS EXT
FREE
KNOB
RANGE SENS
IRIS
OPEN
FULL ±1±2
OPEN SHORT
CABLE
ALARM
CALL
IRIS
PED
ENCR
GY
B RGB
MON SEL
CLS
LOCKKNEE
AUTO
SAT
COLOR
DTL
SKIN
DTL
SOFT
DTL SKIN C.SAT GAMMA
KNEE PT. SLOPE
GAIN
BLACK
FLARE
MASTER
FLARECLR
FILTER
EDCBA54321
HEAD
ND CC EFF
SCENE FILE
STORE
3
7
4
8
1
5
2
6
SHUTTER SUPER V
ON VAR. GAMMA
GAIN(dB)
GAMMA
BLK
1000 +1254
.
MATCH
COLOR
MASTER /PAGE
HOLD MENU
PM IND
LEVEL SKIN HUE QUICK START AWB ABB
AUTO SETUP
CAP BARS CAL CORR
COLOR
MODE SWITCH
KNEE
SUPER
MATRIX
123 L HM
BLK STRETCH
OFFOFF
PANEL
ENABLEPOWER
VF
POWER
HEAD
CAM
POWER
OFF
-11 -7 -3 +3 +7 +11
ON
EFF1 EFF2
CUSTOM COLOR
(%)
0
PED
P.S CONT
PREVIEW
COLOR MATCH
COMM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
CAM POWER switch
HEAD POWER indicator
VF POWER switch
COLOR MATCH switch
MASTER switch
PANEL ENABLE switch
PM IND/PAGE switch
AUTO SETUP switches
MODE switches
FILTER switches
SCENE FILE switches
MODE switches/VR controls
IRIS indicator
AUTO IRIS switch
JOYSTICK (IRIS, M-PED)
(PREVIEW switch)
16
17
18
19
20
21
22
23
24
25
26
27
28
29
CALL switch
ALARM indicator
CABLE OPEN indicator
CABEL SHORT indicator
IRIS RANGE control
IRIS SENS control
MONITOR SELECT switch
KNOB FREE switch
LENS EXT indicator
TALLY indicators
PS CONT connector (OCP-399U only)
COLOR MATCH connectors
COMMAND connector
PREVIEW connector
26
29 28
27
1 2 3 654
7
8
9
11
10
12
13
16
14
15
20
25
22
17
18
21
19
23
24
The switches of cannot be used when the
on-air tally guard is set to "ON".
The START, AWB and ABB switches can be used
only when the auto setup is canceled in the on-air
mode, but the auto setup cannot be executed.
(Refer to "3.6 Internal Switch Settings" for the on-air
tally guard settings.)
Rear View
Note:
㩷1.䇭NAME and FUNCTION㩷1-1
OCP-399 0403 VOL1 (U) (E) OCP-399

1 CAM POWER switch
This switch can control the MAIN POWER of the BS-388 for non-EU area when the BS MAIN POWER switch on the front of
the BS-388 is set to “ON” and the POWER REMOTE/LOCAL switch is set to “REMOTE.” The switch lights when this switch
is set to “ON.”
Note:
The BS-388 for EU area can only control the ON/OFF of the power that is supplied from the BS to the camera. It cannot
control the MAIN POWER of the BS. The BS-593 cannot remote control power supply.
2 HEAD POWER indicator
Lights when the HEAD POWER is ON. Flashes when the camera cable is faulty (OPEN, SHORT).
3 VF POWER switch
Turns ON/OFF the power supply of the VF. When turning OFF the power supply of the VF, press the switch continuously for
two seconds.
Note:
This switch is valid only if the camera head has the VF power ON/OFF function. This switch does not work for the 1.5-inch,
2-inch, 5-inch, and 6-inch viewfinders.
4 COLOR MATCH switch
When pressed, the camera is changed from the master camera to the slave camera to receive color match information. (Refer to
the MASTER switch.)
Reference:
Refer to “3.4.4 Correcting Color Temperature for Multiple Cameras (Color Matching)” for details.
5 MASTER switch
When pressed with the COLOR MATCH switch ON, the camera is changed to the master camera to transfer color match
information to other cameras. (Refer to the COLOR MATCH switch.)
Reference:
Refer to “3.4.4 Correcting Color Temperature for Multiple Cameras (Color Matching)” for details.
6 PANEL ENABLE switch
Enables operations of the OCP.
7 PM IND/PAGE switch
Displays various information in character format to the PM output of the BS. The information is displayed as shown below
each time the switch is pressed.
Display OFF
0
1
2
3
Page
Page
Page
Page
Cameraman's name display
Self-diagnostic information display
Auto setup monitor display
Standby display
.....................
.....................
.....................
.....................
When the PM IND/PAGE switch is held for more than 1 second, the mode is changed to menu remote mode, and the menu of
the camera or BS can be controlled from the OCP. Refer to “3.5 Menu Remote” for details.
8 AUTO SETUP switches
- LEVEL switch, SKIN HUE switch, QUICK switch, START switch
When the START switch is pressed after pressing the LEVEL, SKIN HUE or QUICK switch, the respective auto setups
will be executed. Pressing the switch again while executing setups will cancel the execution. When the execution ends, the
lamp goes OFF. When the execution fails, the START switch flashes. After confirming the failure, press the START switch
again to clear the failure.
1-2㩷1.䇭NAME and FUNCTION
OCP-399 OCP-399 0403 VOL1 (U) (E)

- AWB switch, ABB switch
Used to execute the AWB (auto white balance) or ABB (auto black balance). When the execution ends, the lamp goes OFF.
When the execution fails, the lamp flashes. After confirming the failure, press the flashing switch again to clear the failure.
9 MODE switches
- CAP switch
Used to set the filter to the CAP position.
- BARS switch
Used to set the ENC output signal to the color bar signal.
- CAL switch
Inputs the 100% level CAL signal to the first stage of the internal PRE PROC module on the right side of the camera head.
When the TEST PULSE switch is turned ON by MCP, the lamp of the CAL switch flashes.
- SHUTTER switches
When the SHUTTER ON/OFF switch is pressed, the lamp lights and the preset shutter mode is set and the electronic shutter
starts working. When the switch is pressed again, the lamp goes off and the electronic shutter also stops operating.
While the electronic shutter is operating, the shutter speed will be displayed on the LED display. Select the shutter speed
using the UP/DOWN switches.
LED Display
Shutter Speed
100 120 250 500 1000 2000
1/100 sec 1/120 sec 1/250 sec 1/500 sec 1/1000 sec 1/2000 sec
DOWN UP
Pressing the VARIABLE SHUTTER switch sets the variable shutter mode. The VARIABLE indicator lights up and the
shutter speed is displayed on the LED display. The shutter speed can be selected using the UP/DOWN switches.
- COLOR CORR switch
Used to set COLOR CORRECT to ON. The hue and level of COLOR CORRECT are previously set by the MCP.
- MATRIX switch
Used to select one of the three preset MATRIX settings (1, 2, or 3) or OFF. The LED above the switch indicates the current
preset settings. When it is set to OFF, the switch lamp lights. Each time the switch is pressed, 1, 2, 3, or OFF is selected in
that order repeatedly. Normally, set to "1." The three preset values are previously set by the MCP.
- SUPER KNEE switch
Used to set SUPER KNEE to ON. One of the three SUPER KNEE levels (L, M, or H) can be selected. "H" produces the
largest effect, "M" the next, and "L" the smallest effect. The LED above the switch indicates the current settings. When it
is set to OFF, the switch lamp lights. Each time the switch is pressed, L, M, H, or OFF is selected in that order repeatedly.
Normally, set to "M."
- CUSTOM COLOR switch (EFF1, EFF2)
Used to set CUSTOM COLOR to ON. Two CUSTOM COLOR channels are available, each of which can be independently
set to ON using the EFF1 switch or EFF2 switch. The hue and level of EFF1 and EFF2 are previously set by the MCP.
- BLK STRETCH switch
Used to select the black stretch/press settings. Press the "ON" switch and then the UP/DOWN switch. Any of the
following positions can be selected:
Black stretch : +3, +5, +7, +9, +11
Black press : -11, -9, -7, -5, -3
The LED indicates the current settings. When LEDs for ±11 and ±7 light simultaneously, it indicates ±9. Similarly, when
LEDs for ±7 and ±3 light simultaneously, it indicates ±5.
- GAMMA switch
Select GAMMA using the UP/DOWN switch. One of the following values can be selected: OFF, 0, 45, 0.4, or 0.35. The
LED display indicates the current setting value. Normally, set to "0.45."
- GAIN switch
Select Master Gain using the UP/DOWN switch. One of the following values can be selected: -3, 0, +3, +6, +9, +12, +18,
㩷1.䇭NAME and FUNCTION㩷1-3
OCP-399 0403 VOL1 (U) (E) OCP-399

+24, +20, +36, +42, or +48dB. The LED display indicates the current Gain setting value. Normally, set to "0."
10 FILTER switches
Use the switches to select a position of each filter. When the HEAD indicator is on, it indicates that the camera head is
given control rights, and control from the OCP is disabled. If the switch is pressed in this mode, the switch lamp starts
flashing. Pressing both flashing switches simultaneously shifts the control rights from the camera head to the OCP. To
shift the control rights from the OCP to the camera head, also press both switches simultaneously.
11 SCENE FILE switches
Sets and reads scene files 1 to 8. Files No. 1 to No. 4 and No. 5 to No. 8 can be switched by the toggle switch on the left of the
STORE switch.
Set : Turn ON (lights up) the STORE switch, and press the file number (1 to 8) to be set (lights up).
Read : Press the file number to be read.
12 MODE switches/VR controls
- DTL/SKIN controls
Used to control the DTL and SKIN levels. Turn ON the SOFT DTL and SKIN DTL switches below these controls and
adjust the SOFT DTL and SKIN DTL levels manually.
- C. SAT/GAMMA controls
Used to control the color saturation and gamma levels. The gamma level can be adjusted within ±0.05 of the value (except
for OFF) selected using the GAMMA switch. Turn ON the COLOR SAT switch below these controls and adjust the color
saturation manually. The color saturation can be controlled within the range from 0 to 130%. The burst level will be
constant.
- KNEE POINT/SLOPE controls
Used to control the KNEE SLOPE and POINT manually.
SLOPE
POINT
- SOFT DTL switch
When set to ON, the edge signal is input to the level limiter circuit to control flickering of subjects with large contrast ratio.
- SKIN DTL switch
When set to ON, the skin color of the image is set to the optimum DTL level. This does not affect the color controlled by the
DTL/SKIN controls.
- COLOR SAT switch
Used to turn ON/OFF the color saturation control.
- AUTO KNEE switch
Used to set the AUTO KNEE mode.
- LOCK switch
Use to lock each control (DTL/SKIN, C.SAT/GAMMA, KNEE PT/SLOPE, R GAIN, G GAIN, B GAIN, R BLACK, G
BLACK and B BLACK) in the VR control area. When the LOCK switch lamp is on, you cannot operate by turning these
controls.
- R/G/B GAIN control
Used to control the gain of R, G, and B channels. Controlling the G gain will not change the actual video signal level of G
channel, but the levels of R and B channels change relatively. This is to prevent the change of camera sensitivity settings
caused by the change of the G channel.
- R/G/B BLACK control
Used to control the pedestal or flare of R, G, and B channels. Use the PED FLARE switch to select between pedestal and
flare. If the flare control is selected, the MASTER FLARE indicator lights when the OCP is connected to the camera which
supports MASTER FLARE, indicating the MASTER FLARE control for G channel is active.
1-4㩷1.䇭NAME and FUNCTION
OCP-399 OCP-399 0403 VOL1 (U) (E)

- PED FLARE switch
Used to select between pedestal and flare for the R/G/B BLACK control. Setting this switch to "CLEAR" will cancel the
free operation performed while pressing the KNOB FREE switch (see item 23), and setting a control to the center position
will return its settings to the default.
Notes:
- Even if the control rights are changed from the MCP to the OCP, the value of each VR control that is adjusted on
the MCP is maintained to prevent the video level from changing unintentionally. Therefore, operation may become
one-sided depending on the setting position of the control. The one-sided operation can be corrected by setting the
control to the center position while holding down the KNOB FREE button.
- To return each VR position information, which has been changed as a result of switching to the OCP after operating
the KNOB FREE switch or after controlling from the MCP, to its original position, set each VR to its center position,
and then set the PED FLARE switch to “CLEAR” while pressing the KNOB FREE switch. Each VR position is reset
such that the position of when “CLEAR” is set while pressing the KNOB FREE switch is the center position; therefore,
be sure to set each VR to its center position beforehand. If the PED FLARE switch is set to “CLEAR” without pressing
the KNOB FREE switch, only the VR of FLARE will be reset.
13 IRIS indicator
Displays the F value of the lens. The F value is not displayed (“---” is displayed) when F16 is exceeded to CLOSE.
14 AUTO IRIS switch
Used to set the AUTO IRIS mode.
15 JOYSTICK
- IRIS control and M-PED control
Controls the IRIS of the lens and the master pedestal. In AUTO IRIS mode, the iris is controlled down to ±1 stop F-value.
- PREVIEW switch
By pressing the head of the JOYSTICK, while pressing this switch, pins of A and B in the PREVIEW connector (see item
29) will be short-circuited.
A
B
C
D
E
N.C
N.C
(DC5V 1mA)
PREVIEW switch
PREVIEW connector
IRIS control
M-PED control
Note:
The operation of JOYSTICK is normally set to the relative value mode. It can be switched to the absolute value mode by
changing the internal switch settings. Refer to "3.6 Internal Switch Settings" for how to switch the mode.
Relative value mode
: In this mode, when the control rights are shifted from the MCP to the OCP, the IRIS value
that is adjusted on the MCP is maintained regardless of the position of the IRIS RANGE
control and JOYSTICK to prevent unintentional change of IRIS value. Operation may
become one-sided depending on the position of the control and JOYSTICK. The one-sided
operation can be corrected by setting the control and JOYSTICK to the center position
while holding down the KNOB FREE button.
Absolute value mode : In this mode, the position of the IRIS RANGE control and JOYSTICK directly affects
Open and Close of the IRIS.
16 CALL switch
Lights the R TALLY of the camera head and BS.
㩷1.䇭NAME and FUNCTION㩷1-5
OCP-399 0403 VOL1 (U) (E) OCP-399

17 ALARM indicator
Flashes when an error is detected resulting from the self-diagnosis function. The diagnosis information is automatically
displayed on the PM for about 20 seconds.
18 CABLE OPEN indicator
Lights when the triax cable between the camera head and the BS is broken or not connected. This indicator is interlocked with
the CABLE OPEN indicator on the front of the BS.
19 CABLE SHORT indicator
Lights when the triax cable between the camera head and the BS is short circuited. This indicator is interlocked with the
CABLE SHORT indicator on the front of the BS.
20 IRIS RANGE control
Used to set the center position of the IRIS CONTROL of the JOYSTICK (see item 15).
21 IRIS SENS control
Used to set the IRIS CONTROL range of the JOYSTICK (see item 15). The F-value between ±1 stop and ±2 stops can be set.
22 MONITOR SELECT switch
Used to select the Picture Monitor (PM) or Waveform Monitor (WFM) output signals. The table below shows the output signals
corresponding to each signal position.
Switch Position R G B RGB Y ENC
PM RGBR+G+BYENC
WFM RGBSEQYENC
23 KNOB FREE switch
While this switch is pressed, each VR control (DTL/SKIN, C. SAT/GAMMA, KNEE PT/SLOPE, R/G/B GAIN, R/G/B
BLACK) (see item 12), the IRIS, M-PED control (see item 15), and the IRIS RANGE control (see item 20) are freed, and the
control data is maintained even if these controls are turned. When any of these controls become one-sided as a result of AWB
or AUTO SETUP that is activated without setting the R/G/B GAIN control or R/G/B PED or M-PED control to the center
position, the one-sided control can be corrected by setting the control to the center position while holding down the KNOB
FREE button.
Note:
To return each VR position information, which has been changed as a result of switching to the OCP after operating the
KNOB FREE switch or after controlling from the MCP, to its original position, set each VR to its center position, and
then set the PED FLARE switch (see item 12) to “CLEAR” while pressing the KNOB FREE switch. Each VR position is
reset such that the position of when “CLEAR” is set while pressing the KNOB FREE switch is the center position, thus
be sure to set each VR to its center position beforehand.
24 LENS EXT indicator
Lights up when the lens extender is ON.
25 TALLY indicators
R TALLY and G TALLY indicators. The R TALLY also lights up when the CALL switch of the camera head or BS is pressed.
26 PS CONT connector
Connector for the POWER REMOTE control. When connected to the BS with the POWER CONT cable, the MAIN POWER
can be controlled from the OCP.
Note:
Only the OCP-399U has the PS CONT connector. The OCP-399E does not.
27 COLOR MATCH connectors
Connect the COLOR MATCH cable. Bridge-connecting multiple OCPs with the COLOR MATCH cables enables the color
match operation.
28 COMMAND connector
Connect the CP cable.
29 PREVIEW connector
Output connector for the PREVIEW switch (see item 15).
1-6㩷1.䇭NAME and FUNCTION
OCP-399 OCP-399 0403 VOL1 (U) (E)

2. INSTALLATION and CONNECTION
2.1 Cable Connection Diagram
MON REMOTE
RET
FUSE(5A)
AUTOTALLY
LENS EXT
FREE
KNOB
RANGE SENS
IRIS
OPEN
FULL ±1±2
OPEN SHORT
CABLE
ALARM
CALL
IRIS
PED
ENCR
GY
BRGB
MON SEL
CLS
LOCKKNEE
AUTO
SAT
COLOR
DTL
SKIN
DTL
SOFT
DTL SKIN C.SAT GAMMA
KNEE PT. SLOPE
GAIN
BLACK
FLARE
MASTER
FLARECLR
FILTER
EDCBA54321
HEAD
ND CC EFF
SCENE FILE
STORE
3
7
4
8
1
5
2
6
SHUTTER SUPER V
ON VAR. GAMMA
GAIN(dB)
GAMMA
BLK
1000 +1254
.
MATCH
COLOR
MASTER /PAGE
PM IND
LEVEL SKIN HUE QUICK START AWB ABB
AUTO SETUP
CAP BARS CAL CORR
COLOR
MODE SWITCH
KNEE
SUPER
MATRIX
123 L HM
BLK STRETCH
OFFOFF
PANEL
ENABLEPOWER
VF
POWER
HEAD
CAM
POWER
OFF
-11 -7 -3 +3 +7 +11
ON
EFF1 EFF2
CUSTOM COLOR
(%)
0
PED
OCP
AUTOTALLY
LENS EXT
FREE
KNOB
RANGE SENS
IRIS
OPEN
FULL ±1±2
OPEN SHORT
CABLE
ALARM
CALL
IRIS
PED
ENCR
GY
BRGB
MON SEL
CLS
LOCKKNEE
AUTO
SAT
COLOR
DTL
SKIN
DTL
SOFT
DTL SKIN C.SAT GAMMA
KNEE PT. SLOPE
GAIN
BLACK
FLARE
MASTER
FLARECLR
FILTER
EDCBA54321
HEAD
ND CC EFF
SCENE FILE
STORE
3
7
4
8
1
5
2
6
SHUTTER SUPER V
ON VAR. GAMMA
GAIN(dB)
GAMMA
BLK
1000 +1254
.
MATCH
COLOR
MASTER /PAGE
PM IND
LEVEL SKIN HUE QUICK START AWB ABB
AUTO SETUP
CAP BARS CAL CORR
COLOR
MODE SWITCH
KNEE
SUPER
MATRIX
123 L HM
BLK STRETCH
OFFOFF
PANEL
ENABLEPOWER
VF
POWER
HEAD
CAM
POWER
OFF
-11 -7 -3 +3 +7 +11
ON
EFF1 EFF2
CUSTOM COLOR
(%)
0
PED
OCP
Remote cable
Connection with Camera Head (Self-Contained Operation)
Connection with BS
㩷2.䇭INSTALLATION and CONNECTION㩷2-1
OCP-399 0403 VOL1 (U) (E) OCP-399

2.2 OCP Connection
There are 2 types of use for OCP. The first is self-contained operation in which the OCP is built into the carrying box and connected
to the camera head directly, and the other is use by connecting to a BS.
䂓Connecting OCP and Camera Head (Self-Contained Operation)
Connect the COMM connector of the OCP to the REMOTE connector on the right side of the camera head with the REMOTE
cable.
MON REMOTE
RET
FUSE(5A)
REMOTE connector
COMM connector
Side View of the Camera
OCP
2-2㩷2.䇭INSTALLATION and CONNECTION
OCP-399 OCP-399 0403 VOL1 (U) (E)

䂓Connecting OCP and BS
Connect the COMM connector of the OCP to the OCP/CCP connector of the BS using the CP cable. Connect the P.S CONT
connector of the OCP to the POWER CONT connector on the rear of the BS using the POWER CONT cable.
Note:
The BS-388 for EU area does not use the POWER CONT cable.
Rear view of the BS
OCP
CP cable
maximum 300 m
COMM connector
POWER CONT cable
P.S CONT connector
POWER CONT
connector
OCP/CCP connector
㩷2.䇭INSTALLATION and CONNECTION㩷2-3
OCP-399 0403 VOL1 (U) (E) OCP-399

䂓Turning ON/OFF the power from the OCP
The power of the camera head and BS can be turned ON/OFF simultaneously from the OCP. Connect the P.S CONT connector
of the OCP to the POWER CONT connector on the rear of the BS with the POWER CONT cable. By setting the POWER
REMOTE/LOCAL switch on the front of the BS to “REMOTE” and power switch of the camera head and BS to “ON”, the power
can be turned ON/OFF simultaneously from the OCP.
Note:
The BS-388 for EU area can only control the ON/OFF of the power that is supplied from the BS to the camera. It cannot
control the MAIN POWER of the BS. It is not necessary to connect between the OCP and the BS with the POWER
CONT cable.
䂓Color Matching (When Operating Multi-Camera System)
To adjust the color matching in the multi-camera system which is connected to several OCPs, the data can be transferred between
the OCPs.
Connect the COLOR MATCH connector of the OCP with the COLOR MATCH cable by bridge connection. As the COLOR
MATCH connector IN and OUT cannot be differentiated, the connecting position is free.
COLOR MATCH connector
COLOR MATCH cable
(maximum length 10m)
OCP-1
OCP-2
OCP-3
2-4㩷2.䇭INSTALLATION and CONNECTION
OCP-399 OCP-399 0403 VOL1 (U) (E)

2.3 Connector Pin Function
䂓PS. CONT Connector (only for OCP-399U)
Connector for outputting the power supply ON/OFF control signals of
the camera head and BS.
Main body side : R05-R8M
Cable side : R05-PB8F (8-pin female plug)
Receptacle
Insertion Side
PS CONT (+) ON/OFF control signal for BS POWER (+) OUT
Pin No. Name Function I / O External Interface
A
HE PWR CONT (+) ON/OFF control signal for HEAD POWER (+) OUT
B
N. C (spare) _
C
N. C (spare) _
D
PS CONT (-) ON/OFF control signal for BS POWER (-) OUT
G
HE PWR CONT (-) ON/OFF control signal for HEAD POWER (-) OUT
H
N. C (spare) _
E
(HEAD ON IND) (spare) _
F
G
F
E
D
C
B
A
H
䂓COLOR MATCH Connector
Connector for outputting the color matching control signal.
Main body side : R05-R5F
Cable side : R05-PB5M (5-pin male plug)
Receptacle
Insertion Side
A
C
BD
E
HET TRX (+) Color matching control signal output (+) OUT
Pin No. Name Function I / O External Interface
A
HET TRX (-) Color matching control signal output (-) OUT
GND
B
HET GND Ground for Color matching control signal
C
N. C (spare) _
D
N. C (spare) _
E
㩷2.䇭INSTALLATION and CONNECTION㩷2-5
OCP-399 0403 VOL1 (U) (E) OCP-399

䂓COMMAND Connector
Connector for inputting and outputting various control signals with the
BS.
Main Body Side : PRC05 - R8M
Cable Side : PRC90 - 199P9 - 8F (8-pin female plug)
or equivalent
Receptacle
Insertion Side
HED RX (+) Digital data input (+)
BS -> Control Panel
IN
Pin No. Name Function I / O External Interface
A
HED RX (-) Digital data input (-)
BS -> Control Panel
IN
OUT
OUT
IN
RET
B
HEC TX (+) Digital data output (+)
Control Panel -> BS
C
HEC TX (-) Digital data output (-)
Control Panel -> BS
D
INCOM TALK INCOM microphone signal to BS OUT
G
INCOM RECEIVE INCOM receiver signal from BS IN
H
+ 12 V DC + 12 V power supply from BS
E
+ 12 V RET Ground for DC + 12 V power supply
F
G
F
E
D
C
B
A
H
2-6㩷2.䇭INSTALLATION and CONNECTION
OCP-399 OCP-399 0403 VOL1 (U) (E)

3. OPERATION
3.1 Turning ON Power
3.1.1 BS-388 for Non-EU Area
Normally, set the switches as follows, and turn ON/OFF the power using the CAM POWER switch on the OCP.
䃂Camera head (Camera adaptor)
HEAD POWER switch : ON
㩷㩷 䃂
BS
HEAD POWER switch : | (ON)
BS MAIN POWER switch : | (ON)
POWER REMOTE/LOCAL switch : REMOTE
AUTOTALLY
LENS EXT
FREE
KNOB
RANGE SENS
IRIS
OPEN
FULL ±1±2
OPEN SHORT
CABLE
ALARM
CALL
IRIS
PED
ENCR
GY
B RGB
MON SEL
CLS
LOCKKNEE
AUTO
SAT
COLOR
DTL
SKIN
DTL
SOFT
DTL SKIN C.SAT GAMMA
KNEE PT. SLOPE
GAIN
BLACK
FLARE
MASTER
FLARECLR
FILTER
EDCBA54321
HEAD
ND CC EFF
SCENE FILE
STORE
3
7
4
8
1
5
2
6
SHUTTER SUPER V
ON VAR. GAMMA
GAIN(dB)
GAMMA
BLK
1000 +1254
.
MATCH
COLOR
MASTER /PAGE
PM IND
LEVEL SKIN HUE QUICK START AWB ABB
AUTO SETUP
CAP BARS CAL CORR
COLOR
MODE SWITCH
KNEE
SUPER
MATRIX
123 L HM
BLK STRETCH
OFFOFF
PANEL
ENABLEPOWER
VF
POWER
HEAD
CAM
POWER
OFF
-11 -7 -3 +3 +7 +11
ON
EFF1 EFF2
CUSTOM COLOR
(%)
0
PED
HOLD MENU
OCP Front View of the BS
HEAD POWER switch
POWER REMOTE/LOCAL switch
BS MAIN POWER switch
CAM POWER switch
3.1.2 BS-388 for EU Area
Turn ON/OFF the power using the BS MAIN POWER switch. The CAM POWER switch on the OCP can only turn ON/OFF the
HEAD POWER.
㩷3.䇭OPERATION㩷3-1
OCP-399 0403 VOL1 (U) (E) OCP-399
Table of contents
Other Ikegami Control Panel manuals
Popular Control Panel manuals by other brands

Sony
Sony RM-X7BT reference guide

Gira
Gira G1 Installation and operating instructions for the installer

AdvanteX
AdvanteX VCOM AX20-B installation manual

Notifier
Notifier AFP-300 Operation manual

Cooper Menvier
Cooper Menvier Scantronic 9651 Installation and programming guide

HomeMatic
HomeMatic HomeMatic user guide