IMI SENSORS 625B21 User manual

Model 625B21
Precision Industrial ICP® Accelerometer
Installation and Operating Manual
For assistance with the operation of this product,
contact PCB Piezotronics, Inc.
Toll-free: 800-959-4464
24-hour SensorLine: 716-684-0001
Fax: 716-684-3823
E-mail: [email protected]
Web: www.imi-sensors.com

The information contained in this document supersedes all similar information that
may be found elsewhere in this manual.
Service –Due to the sophisticated
nature of the sensors and associated
instrumentation provided by PCB
Piezotronics, user servicing or repair is
not recommended and, if attempted,
may void the factory warranty. Routine
maintenance, such as the cleaning of
electrical connectors, housings, and
mounting surfaces with solutions and
techniques that will not harm the
physical material of construction, is
acceptable. Caution should be observed
to ensure that liquids are not permitted
to migrate into devices that are not
hermetically sealed. Such devices
should only be wiped with a dampened
cloth and never submerged or have
liquids poured upon them.
Repair –In the event that equipment
becomes damaged or ceases to
operate, arrangements should be made
to return the equipment to PCB
Piezotronics for repair. User servicing or
repair is not recommended and, if
attempted, may void the factory
warranty.
Calibration –Routine calibration of
sensors and associated instrumentation
is recommended as this helps build
confidence in measurement accuracy
and acquired data. Equipment
calibration cycles are typically
established by the users own quality
regimen. When in doubt about a
calibration cycle, a good “rule of thumb”
is to recalibrate on an annual basis. It is
also good practice to recalibrate after
exposure to any severe temperature
extreme, shock, load, or other
environmental influence, or prior to any
critical test.
PCB Piezotronics maintains an ISO-
9001 certified metrology laboratory and
offers calibration services, which are
accredited by A2LA to ISO/IEC 17025,
with full traceability to SI through
N.I.S.T. In addition to the normally
supplied calibration, special testing is
also available, such as: sensitivity at
elevated or cryogenic temperatures,
phase response, extended high or low
frequency response, extended range,
leak testing, hydrostatic pressure
testing, and others. For information on
standard recalibration services or
special testing, contact your local PCB
Piezotronics distributor, sales
representative, or factory customer
service representative.
Returning Equipment –Following
these procedures will ensure that your
returned materials are handled in the
most expedient manner. Before
returning any equipment to PCB
Piezotronics, contact your local
distributor, sales representative, or
factory customer service representative
to obtain a Return Warranty, Service,
Repair, and Return Policies and
Instructions Materials Authorization
(RMA) Number. This RMA number
should be clearly marked on the outside
of all package(s) and on the packing
Service, Repair, and Return
Policies and Instructions

list(s) accompanying the shipment. A
detailed account of the nature of the
problem(s) being experienced with the
equipment should also be included
inside the package(s) containing any
returned materials.
A Purchase Order, included with the
returned materials, will expedite the
turn-around of serviced equipment. It is
recommended to include authorization
on the Purchase Order for PCB to
proceed with any repairs, as long as
they do not exceed 50% of the
replacement cost of the returned
item(s). PCB will provide a price
quotation or replacement
recommendation for any item whose
repair costs would exceed 50% of
replacement cost, or any item that is not
economically feasible to repair. For
routine calibration services, the
Purchase Order should include
authorization to proceed and return at
current pricing, which can be obtained
from a factory customer service
representative.
Contact Information –International
customers should direct all inquiries to
their local distributor or sales office. A
complete list of distributors and offices
can be found at www.pcb.com.
Customers within the United States may
contact their local sales representative
or a factory customer service
representative. A complete list of sales
representatives can be found at
www.pcb.com. Toll-free telephone
numbers for a factory customer service
representative, in the division
responsible for this product, can be
found on the title page at the front of this
manual. Our ship to address and
general contact numbers are:
PCB Piezotronics, Inc.
3425 Walden Ave.
Depew, NY14043 USA
Toll-free: (800) 828-8840
24-hour SensorLineSM: (716) 684-0001
Website: www.pcb.com

PCB工业监视和测量设备 - 中国RoHS2公布表
PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table
部件名称
有害物质
铅(Pb)
汞
(Hg)
镉
(Cd)
六价铬(Cr(VI))
多溴联苯 (PBB)
多溴二苯醚(PBDE)
住房
O
O
O
O
O
O
PCB板
X
O
O
O
O
O
电气连接器
O
O
O
O
O
O
压电晶体
X
O
O
O
O
O
环氧
O
O
O
O
O
O
铁氟龙
O
O
O
O
O
O
电子
O
O
O
O
O
O
厚膜基板
O
O
X
O
O
O
电线
O
O
O
O
O
O
电缆
X
O
O
O
O
O
塑料
O
O
O
O
O
O
焊接
X
O
O
O
O
O
铜合金/黄铜
X
O
O
O
O
O
本表格依据 SJ/T 11364 的规定编制。
O:表示该有害物质在该部件所有均质材料中的含量均在 GB/T 26572 规定的限量要求以下。
X:表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572 规定的限量要求。
铅是欧洲RoHS指令2011/65/ EU附件三和附件四目前由于允许的豁免。
CHINA RoHS COMPLIANCE

DOCUMENT NUMBER: 21354
DOCUMENT REVISION: D
ECN: 46162
Component Name
Hazardous Substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Chromium VI
Compounds
(Cr(VI))
Polybrominated
Biphenyls
(PBB)
Polybrominated
Diphenyl
Ethers (PBDE)
Housing
O
O
O
O
O
O
PCB Board
X
O
O
O
O
O
Electrical
Connectors
O
O
O
O
O
O
Piezoelectric
Crystals
X
O
O
O
O
O
Epoxy
O
O
O
O
O
O
Teflon
O
O
O
O
O
O
Electronics
O
O
O
O
O
O
Thick Film
Substrate
O
O
X
O
O
O
Wires
O
O
O
O
O
O
Cables
X
O
O
O
O
O
Plastic
O
O
O
O
O
O
Solder
X
O
O
O
O
O
Copper Alloy/Brass
X
O
O
O
O
O
This table is prepared in accordance with the provisions of SJ/T 11364.
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit
requirement of GB/T 26572.
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above
the limit requirement of GB/T 26572.
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU.

INDUSTRIAL MONITORIN
G INSTRUMENTATION DI
VISION
SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING
Piezoelectric ICP ® Accelerometers Operating Guide
Operating Guide with Enclosed Warranty Information
3425 Walden Avenue, Depew, New York 14043-2495
Phone (716) 684-0003
Fax (716) 684-3823
Toll Free Line 1-800-959-4IMI
MANUAL NUMBER: 18405
MANUAL REVISION: NR












Model Number
625B21 PRECISION INDUSTRIAL ICP® ACCELEROMETER Revision: F
ECN #: 46537
Performance ENGLIS
H
S
I
Sensitivity(± 5 %) 100 mV/g 10.2 mV/(m/s²) [2
]
Measurement Range ± 50 g ± 490 m/s²
Frequency Range(± 5 %) 30 to 390,000 cpm 0.5 to 6500 Hz [3]
Frequency Range(± 10 %) 22 to 450,000 cpm 0.37 to 7500 Hz
Frequency Range(± 3 dB) 12 to 630,000 cpm 0.2 to 10,500 Hz
Resonant Frequency 1500 kcpm 25 kHz [1
]
Broadband Resolution(1 to 10,000 Hz) 50 µg 491 µm/sec2[1
]
Non-Linearity ± 1 % ± 1 % [4]
Transverse Sensitivity ≤5 % ≤5 %
Environmental
Overload Limit(Shock) 5000 g pk 49,050 m/s² pk
Temperature Range -65 to +250 °F -54 to +121 °C
Temperature Response See Graph See Graph [1
]
Enclosure Rating IP66 IP66
Electrical
Settling Time(within 1% of bias) ≤8.0 sec ≤8.0 sec
Discharge Time Constant ≥1.0 sec ≥1.0 sec
Excitation Voltage 18 to 28 VDC 18 to 28 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance <100 Ohm <100 Ohm
Output Bias Voltage 8 to 12 VDC 8 to 12 VDC
Spectral Noise(10 Hz) 2.5 µg/√Hz 24.5 (µm/sec2)/√Hz [1]
Spectral Noise(100 Hz) 0.8 µg/√Hz 7.8 (µm/sec2)/√Hz [1
]
Spectral Noise(1 kHz) 0.5 µg/√Hz 4.9 (µm/sec2)/√Hz [1
]
Electrical Protection RFI/ESD RFI/ESD
Electrical Isolation(Case) >108Ohm >108Ohm
Physical
Size (Diameter x Height) 1.38 in x 1.13 in 35.1 mm x 28.7 mm
Weight(without cable) 4.7 oz 133 gm
Mounting Through Hole Through Hole
Mounting Thread 1/4-28 Male Not Applicable [5]
Mounting Torque 2 to 5 ft-lb 2.7 to 6.8 Nm
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Stainless Steel Stainless Steel
Sealing Welded Hermetic Welded Hermetic
Cable Length 10 ft 3.0 m
Cable Type FEP FEP [6]
[7]
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP®is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
EX - Hazardous Area Approval- contact factory for specific approvals
LB - Low Bias Voltage
Output Bias Voltage 6 to 8 VDC 6 to 8 VDC
Excitation Voltage 12 to 28 VDC 12 to 28 VDC
Measurement Range ± 35 g ± 343 m/s²
M- Metric Mount
Supplied Accessor
y
: Model M081A73 Mountin
g
Bolt M6 x 1.00 replaces Model 081A7
3
NOTES:
[1
]
Typical
.
[2
]
Conversion Factor 1
g
= 9.81 m/s².
[3] The high frequency tolerance is accurate within ±10% of the specified frequency.
[4] Zero-based, least-squares, straight line method.
[5
]
1/4-28 has no equivalent in S.I. units
.
[6
]
Twisted shielded pair
.
[7] See PCB Declaration of Conformance PS023 or PS061 for details.
SUPPLIED ACCESSORIES:
Model 080B45 Thermal Boot (1)
Model 081A73 Captive mounting bolt 1/4-28 x 1.34" (1)
Model ICS-1 NIST-traceable single-axis amplitude response calibration from 600 cpm (10 Hz) to
upper 5% frequency
Entered: LK Engineer: gs Sales: M
C
A
pproved: BA
M
Spec Number:
Date: 3/3/201
7
Date: 3/3/201
7
Date: 3/3/201
7
Date: 3/3/201
7
9910
3425 Walden Avenue, Depew, NY 14043
Phone: 800-959-4464
Fax: 716-684-3823
E-Mail: [email protected]

This manual suits for next models
1
Table of contents
Other IMI SENSORS Measuring Instrument manuals

IMI SENSORS
IMI SENSORS 685B-Series User manual

IMI SENSORS
IMI SENSORS 600A03 User manual

IMI SENSORS
IMI SENSORS PCB Piezotronics M623C11 User manual

IMI SENSORS
IMI SENSORS TO603C01 User manual

IMI SENSORS
IMI SENSORS EX615A42 User manual

IMI SENSORS
IMI SENSORS PCB Piezotronics TO622B01 User manual

IMI SENSORS
IMI SENSORS PCB PIEZOTRONICS ICP 66162ANZ1 User manual

IMI SENSORS
IMI SENSORS EXM640B12 User manual

IMI SENSORS
IMI SENSORS 624B61/050BZ User manual

IMI SENSORS
IMI SENSORS Y687A02 User manual