Hanna Instruments HI 771 User manual

Chlorine Ultra High Range Preliminary examination:
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please notify your Dealer.
Each HI 771 meter is supplied complete with:
• Two Sample Cuvettes and Caps
• Six packets of Reagent A
• Six packets of Reagent B
• 1 x 1.5V AAA Battery
• Instruction Manual
HI 771
Functional description:
Errors and warnings:
Light High: There is too much light to perform a measurement.
Please check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement.
Please check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you
use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the
meter.
1. Dust cover.
2. Cuvette with cap.
3. Cuvette holder.
4. Liquid Crystal Display.
5. Button.
For more details about spare parts and accessories
see “Accessories”.
Technical specifications:
Range 0 to 500 ppm
Resolution 1 ppm
Accuracy ±3 ppm ±5% of reading @ 25 °C / 77 °F
Light Source Light Emitting Diode @ 525 nm
Light Detector Silicon Photocell
Method Adaptation of Standard Methods for the Examination of
Water and Wastewater, 20th edition, 4500-Cl.
Environment 0 to 50 °C (32 to 122 °F);
max 95% RH non-condensing
Battery Type 1 x 1.5V AAA
Auto-Shut off After 10 minutes of non-use
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)
Dear Customer,
Thank you for choosing a Hanna Instruments Product.
Please read this instruction manual carefully before using the instrument. If you need
additional technical information, do not hesitate to e-mail us at [email protected]
or view our worldwide contact list at www.hannainst.com.
•Turn the meter on by pressing the button.
All segments will be displayed. When the
display shows “Add”, “C.1” with “Press”
blinking, the meter is ready.
•Fill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the cuvette
into the meter and close the meter’s cap.
•Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the
meter is zeroed.
•Remove the cuvette from the meter and
unscrew the cap. Add the content of one
packet of HI 771A-0 reagent and one packet
of HI 771B-0 reagent.
•Replace the cap and shake gently for 20 seconds.
Place the cuvette back into the meter.
•Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement)
or, alternatively, wait for 1 minute and press
the button.
•The instrument displays concentration in ppm
of chlorine. The meter automatically turns
off after 10 minutes.
10 mL
•It is important that the sample does not contain any debris.
•Whenever the cuvette is placed into the measurement cell, it must be dry
outside, and completely free of fingerprints, oil and dirt. Wipe it thoroughly with
HI 731318 or a lint-free cloth prior to insertion.
•Shaking the cuvette can generate bubbles, causing higher readings. To obtain
accurate measurements, remove bubbles by swirling or by gently tapping the
cuvette.
•Do not let the reacted sample stand for too long after reagent is added, as
accuracy will be affected.
•After the reading it is important to immediately discard the sample, otherwise
the glass might become permanently stained.
REAGENT SETS
HI 771-25 Reagent set for 25 Chlorine Ultra High Range tests
OTHER ACCESSORIES
HI 771-11 Chlorine UHR Certified Standard Kit
HI 731318 Cloth for wiping cuvettes (4 pcs.)
HI 731321 Glass cuvettes (4 pcs.)
HI 731225 Cuvette black cap for checker HC (4 pcs.)
HI 731353 Cuvette seal cap for checker HC (4 pcs.)
HI 740028 1.5V AAA batteries (4 pcs.)
HI 93703-50 Cuvette cleaning solution (230 mL)
Recommendations for Users
Before using this product, make sure that it is entirely suitable for your specific application and for the
environment in which it is used.
Operation of this instrument may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance.
To avoid damage or burns, do not put the instrument in microwave oven. For the safety of you and the
instrument do not use or store the instrument in hazardous environments.
Hanna Instruments reserves the right to modify the design, construction or
appearance of its products without advance notice.
Battery management
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead
the instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
•Turn the instrument off by holding the button until the meter shuts off.
•Turn the instrument upside down and remove the battery cover with a screwdriver.
•Remove the battery from its location and replace it with a new one, inserting the
negative end first.
•Insert the battery cover and replace the screw with a screwdriver.
IST771 04/13
Measurement procedure: Accessories:Tips for an accurate measurement

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI83303 User manual

Hanna Instruments

Hanna Instruments HI83303 User manual

Hanna Instruments HI 5315 User manual

Hanna Instruments

Hanna Instruments HI 5315 User manual

Hanna Instruments HI 9813-5 User manual

Hanna Instruments

Hanna Instruments HI 9813-5 User manual

Hanna Instruments HI83303 User manual

Hanna Instruments

Hanna Instruments HI83303 User manual

Hanna Instruments HI 933300 User manual

Hanna Instruments

Hanna Instruments HI 933300 User manual

Hanna Instruments HI97704 User manual

Hanna Instruments

Hanna Instruments HI97704 User manual

Hanna Instruments HI 8014 User manual

Hanna Instruments

Hanna Instruments HI 8014 User manual

Hanna Instruments HI 93753 User manual

Hanna Instruments

Hanna Instruments HI 93753 User manual

Hanna Instruments HI97753 User manual

Hanna Instruments

Hanna Instruments HI97753 User manual

Hanna Instruments Checktemp 1 User manual

Hanna Instruments

Hanna Instruments Checktemp 1 User manual

Hanna Instruments HI 9142 User manual

Hanna Instruments

Hanna Instruments HI 9142 User manual

Hanna Instruments HI 991003 User manual

Hanna Instruments

Hanna Instruments HI 991003 User manual

Hanna Instruments HI 991300 User manual

Hanna Instruments

Hanna Instruments HI 991300 User manual

Hanna Instruments HI 250 User manual

Hanna Instruments

Hanna Instruments HI 250 User manual

Hanna Instruments HI 746 User manual

Hanna Instruments

Hanna Instruments HI 746 User manual

Hanna Instruments HI 2209 User manual

Hanna Instruments

Hanna Instruments HI 2209 User manual

Hanna Instruments Conmet1 (HI 98305 User manual

Hanna Instruments

Hanna Instruments Conmet1 (HI 98305 User manual

Hanna Instruments Checker HI718 User manual

Hanna Instruments

Hanna Instruments Checker HI718 User manual

Hanna Instruments LP 2000 User manual

Hanna Instruments

Hanna Instruments LP 2000 User manual

Hanna Instruments HALO 2 HI9810342 User manual

Hanna Instruments

Hanna Instruments HALO 2 HI9810342 User manual

Hanna Instruments HI96800 User manual

Hanna Instruments

Hanna Instruments HI96800 User manual

Hanna Instruments HI84531-02 User manual

Hanna Instruments

Hanna Instruments HI84531-02 User manual

Hanna Instruments HI 758 User manual

Hanna Instruments

Hanna Instruments HI 758 User manual

Hanna Instruments HI723 User manual

Hanna Instruments

Hanna Instruments HI723 User manual

Popular Measuring Instrument manuals by other brands

Tektronix 1502B Service manual

Tektronix

Tektronix 1502B Service manual

Endress+Hauser Proline Prosonic Flow 93 Function manual

Endress+Hauser

Endress+Hauser Proline Prosonic Flow 93 Function manual

Sealey TA203.V2 instructions

Sealey

Sealey TA203.V2 instructions

Keysight x series Installation notes

Keysight

Keysight x series Installation notes

KJ Instrument KJ6013 Operation manual

KJ Instrument

KJ Instrument KJ6013 Operation manual

KROHNE OPTIFLUX 2070 Handbook

KROHNE

KROHNE OPTIFLUX 2070 Handbook

Veris Industries E51C2A installation guide

Veris Industries

Veris Industries E51C2A installation guide

RTX 6001 user manual

RTX

RTX 6001 user manual

Siemens SENTRON PAC4200 manual

Siemens

Siemens SENTRON PAC4200 manual

MARTINDALE TEK100 instruction manual

MARTINDALE

MARTINDALE TEK100 instruction manual

MRC DI-900 Operation manual

MRC

MRC DI-900 Operation manual

Elcon SA10A user manual

Elcon

Elcon SA10A user manual

Schroeder Industries HY-TRAX Operating and maintenance instructions

Schroeder Industries

Schroeder Industries HY-TRAX Operating and maintenance instructions

MSI 2000 Programming manual

MSI

MSI 2000 Programming manual

WAGNER C575 instruction manual

WAGNER

WAGNER C575 instruction manual

Newport 1825-C Operator's manual

Newport

Newport 1825-C Operator's manual

jwLabs A3 Instruction manuals

jwLabs

jwLabs A3 Instruction manuals

Endress+Hauser Prosonic S FMU90 operating instructions

Endress+Hauser

Endress+Hauser Prosonic S FMU90 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.