impact Ready Cool FRC-24 User manual

FRC-24
Ready Cool
Fluorescent Light
INSTRUCTIONS

2
Precautions ⚠⚡
• Handle uorescent bulbs with care.
See Note below.
• Dispose of uorescent bulbs
properly.
• Please read and follow these
instructions, and keep this manual
in a safe place.
• Keep this unit away from water and
all ammable gases or liquids.
• Make sure the unit is powered
off when plugging it into a power
source.
• Use only the correct,
recommended voltage.
• Do not attempt to disassemble or
repair the equipment—doing so
will void the warranty, and Impact
will not be responsible for any
damage.
• Handle the unit with care.
• Do not stare at the lights when they
are powered on.
• Clean the unit with a soft, dry cloth.
• Keep this unit away from children.
• Use only parts provided by the
manufacturer.
• Make sure the item is intact and
that there are no missing parts.
• All photos are for illustrative
purposes only.
Note: Fluorescent bulbs contain mercury. If a uorescent bulb breaks, do not
touch mercury with hands—exposure to mercury can lead to adverse health
effects.

3
Introduction
Thank you for choosing Impact.
Thank you for choosing the Impact FRC-24 220 W Ready
Cool Fluorescent Light. This lightweight daylight-balanced
uorescent lighting xture is an inexpensive way to produce
soft, professional lighting in the studio or on location.
Fluorescent bulbs deliver diffused, attering light. Fluorescents
are also cool to the touch, so they’re ideal for photographing
anything that’s affected by heat, like food or people. The FRC-24
air-induction cooling system keeps everything really cool.
Your Ready Cool light has a exible stand adapter that makes
it possible to mount the xture to most light stands and easily
position the light. The built-in barn doors provide control over
your lighting. The easy-access built-in fuse protects the unit
from overloaded electrical circuits—it’s always a good idea to
keep spare fuses on hand.
The included daylight-balanced bulbs will produce light with
a color temperature similar to daylight. The hammered silver
reective surface on the barn doors maximizes light output. The
FRC-24 xture has two switches to select full or half power—
you can choose between 220 W or 110 W for greater lighting
versatility.

4
Features
• Cool-running daylight-balanced
uorescent lights
• Flicker-free lighting
• Lightweight xture
• Built-in barn doors with hammered
silver reective surface
• Air-induction cooling
• 2-bulb/4-bulb switching
• Built-in fuse circuit protection
• Padded carrying case
Contents Include
• FRC-24 Ready Cool Fluorescent
Light Fixture
• Four 55 W 4-pin twin-tube daylight
uorescent bulbs
• AC power cord
• Flexible light stand adapter
• 2 Spare fuses
• Soft padded carrying case
• User manual
Specications
Input Voltage 110~240 VAC 50/60 Hz
Amperage 1.1 amps
Bulb Switching 4 bulbs/2 bulbs
Bulb Type Standard 4-pin twin-tube daylight
uorescent
Dimensions 22.25 × 10.87 × 3.5 in.
(56.51 × 27.61 × 8.89 cm)
Weight (including bulbs) 6.5 lb. (2.95 kg)

5
Setup
Mounting bulbs in the xture
1. Disconnect xture from power
source
2. Remove plastic retaining clip
3. Position bulb with printed side of
base end facing up
4. Make sure pins on bulb align with
holes in base

6
5. Carefully slide bulb into base until
the clip locks the bulb into place
6. Be sure bulb is securely locked
into base
7. Replace plastic retaining clip
8. Repeat procedure for each bulb
9. Before you turn the Ready Cool
xture on for the rst time, be sure
that the fuse holder on the back of
the unit is turned clockwise until
tight. If it’s loose, the lights will not
turn on.

7
Removing bulbs from the xture
1. Disconnect xture from power
source
2. Remove plastic retaining clip
3. Push metal clip on base to release
bulb
4. Carefully pull bulb out of base
5. Replace plastic retaining clip.

One-Year Limited Warranty
This Impact product is warranted to the original purchaser to be free from defects in materials
and workmanship under normal consumer use for a period of one (1) year from the original
purchase date or thirty (30) days after replacement, whichever occurs later. The warranty
provider’s responsibility with respect to this limited warranty shall be limited solely to repair
or replacement, at the provider’s discretion, of any product that fails during normal use of this
product in its intended manner and in its intended environment. Inoperability of the product
or part(s) shall be determined by the warranty provider. If the product has been discontinued,
the warranty provider reserves the right to replace it with a model of equivalent quality and
function.
This warranty does not cover damage or defect caused by misuse, neglect, accident,
alteration, abuse, improper installation or maintenance. EXCEPT AS PROVIDED HEREIN,
THE WARRANTY PROVIDER MAKES NEITHER ANY EXPRESS WARRANTIES NOR ANY
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This warranty provides you
with specic legal rights, and you may also have additional rights that vary from state to state.
To obtain warranty coverage, contact the Impact Customer Service Department to obtain
a return merchandise authorization (“RMA”) number, and return the defective product to
Impact along with the RMA number and proof of purchase. Shipment of the defective product
is at the purchaser’s own risk and expense.
For more information or to arrange service, visit www.impactstudiolighting.com or call
Customer Service at 212-594-2353.
Product warranty provided by the Gradus Group.
www.gradusgroup.com
Impact is a registered trademark of the Gradus Group.
© 2020 Gradus Group LLC. All Rights Reserved.
GG6
Table of contents