CONTROL PANEL FOR STEAM BATH ECOTOUCH
This equipment has the following features:
• Level water boiler control
• Bath temperature control
• Heating control
• Fan control
• Lighting control
• Timer on and off
• Scent dosing control
• Troubleshooting
Keyboard Function
On / Off - ECO
More
Optional menu
Light
Temperature selection
Scent
Less
Ok / accept
Timer
Fan
General operation
On / Off - ECO
The equipment turns on with the ON / OFF key on the keyboard.
It can be turned on remotely connecting a pulse generator to the terminal blocks attached for that purpose
Once it’s ON, display shows on the left, the current temperature value being calibrated by the probe, and
on the right the desired temperature (selected). An animation of arrows shows that the device is being
heated to reach the desired temperature.
Once desired temperature is achieved, the display shows the temperature value and the arrows’ anima-
tion disappear.
The ECO system is designed to provide energy saving, lowering the top temperature value to 40 degrees
Celsius. It is turned on with the keyboard off and pressing the icon for 3-4 seconds.
Function keys
Scent
Aromatherapy is automatically enabled once the keyboard is on. It can be switched on / off at any time
using the corresponding selection key.
Press and hold the Scent Key for a few seconds to access settings menu.
Pressing“+”“-“keysyouselectintermittentfunctioning,rstlyspecifythenumberofdiffusiondosese-
conds followed by the minutes of break. In order to set the change, press the “accept” key.
More Less Ok / Acept
Optional menu
Pressing this button you access optional steam bath settings menu.
Pressing selection keys and noticing where the selection arrow is, you select optional functions. Press
“accept” key to access any optional feature.
• Cromotherapy:
Oncecromotherapykeyisselectedyouwillnd3optionalsettingstoestablishthecolour,theworking
programme and the start-up/shutdown functions. Scroll through the menu with selection keys.
- Colour: Selection of a steady colour.
- Working programme: Selection of one out of 3 default programmes.
- Bulb item: Selection of cromotherapy shutdown.
• Panellevelprobe
To control the level of water, the boiler has a probe with two levels at the same high. If one of them stop
working it is detected and start to work the other one.
To access to this panel press during some seconds both key ot the timer. This panel will show the state
of the level probe, for example if we see NIV 1:ok-Niv 2 X, it means level 1 works correctly and level 2
has been ingnored.
The system is designed to work in both levels, in the case that both probe are damaged we will have to
change the probe. Once it is changed we have to set it in the equipment, access to this panel and reset
with the key “Light”, one we reseted the sreen will show Niv1:OK-Niv 2 OK”.
• Opticalbrecromotherapy(F.O.)
Onceopticalbrecromotherapykeyisselectedyouwillnd2optionalsettingtoestablishthestart-up/
shutdown and the colour functions. Scroll through the menu with selection keys.
-On/off:Selectionforturningonandoffopticalbrecromotherapy.Toturnitoffpressandholdthe“ac-
cept” key for 4 seconds
- Colour: Colour variation is a default setting. Press this key when the desired colour is lighting to set it
as a steady colour.
• Inputandoutputpanel:
In this panel we can see the state of the input and outputs. Access pressing Clock (7 and 8) keys during
some seconds. In the diagram it is indicated the Meaning of the details showed in the panel:
Light
The lamp is automatically switched on and off when the equipment is on / off. Select the corresponding
key to control it independently.
Timer
You may select timer with the second key of clock button, even if the steam bath is switched off.
Once selected, you set the time to be turn off with a minimum of 30 minutes. With the “+” and “-“ keys you
may set intervals of 15 minutes range of variation.
Once you press the button, a steady light indicates that a programme is on going.
If you set the timer when the steam bath is off, timing will start once the equipment is turned on.
If you set the timer when the steam bath is on, timing will start immediately indicating the remaining time
to be turned off on the screen.
Once timer is enabled it will repeat every time you turn the steam bath on unless the option is disabled.
Temperature selection
The desired temperature value to be reached is showed on the right of the screen.
Press “ºC” key to change the room temperature value. Set the new desired value with the “+” and “-“
buttons. Press “ºC” key to exit and set the new selected temperature value.
If after 10 seconds “ºC” key is not pressed to exit temperature selection, you will be withdrawn with no
changes.
Fan
Ventilation is activated automatically once the equipment is turned on and off. It turns off after 20 minutes
shutdown, allowing water steam being built up in the room to eliminate.
You must not interfere with its proper functioning.
Troubleshooting:
----SondaTemp..corto.Avisenserv.tec.
The temperature probe has a short circuit.
----SondaTemp.defet.Avisenserv.tec.
The temperature probe give a value above the desired temperature so it means it is
breakdown.
----Desagüeobturado.Avisenserv.tec.
Thesystemitistryingtolluptheboile.Thedrainitiscolapsed,orthevalveofll
up or level probe it is damaged.
----Detectadaavería.Avisenserv.tec.
Contact with the after sales service.
----Alarmatemp.Avisenserv.tec.
For an excess of temperature the security thermostat has set off. It has to be norma-
lised after switching on again.
----Cald.nosellena.Avisenserv.tec.
During many time the system is trying to switch on and there is any change in the
levels:thereisnowatersupply,thellinvalveisdamage,thellupvalveisdamage,
thellinvalveitisopenorthelevelprobeisdamage.
----Norecibedatos.Avisenserv.tec.
The connection between the panel and the generator has some cable brokken or
disconnected.
----Ventil.apagada:Sistemaparado
The ventilation is switch off manually with the bath working during more than 15
minutes and it appears this message on the panel. It is enough with switch on again
the ventilation.
----Vent.Invertido.Avisenserv.tec.
the fan of the precipitate of direct current it is connected on the other way round, you
have to invert the polarity.
----Aguanoevapora.Avisenserv.tec.
The system has detected that after 20 minutes, there is no change in the levels. Le-
vel probe damage, Bath temperature higher than the temperature registered.

Popular Control Unit manuals by other brands

Dakota Digital BIM-01-2-FTCH manual

Dakota Digital

Dakota Digital BIM-01-2-FTCH manual

Bartec SILASPZ manual

Bartec

Bartec SILASPZ manual

Festo CPX-E-EP Instructions for use

Festo

Festo CPX-E-EP Instructions for use

Grundfos CIM 060 Installation and operating instructions

Grundfos

Grundfos CIM 060 Installation and operating instructions

idatastart CMCHXA0 install guide

idatastart

idatastart CMCHXA0 install guide

IRIS IRIS-IO quick start guide

IRIS

IRIS IRIS-IO quick start guide

Kessel Staufix DA 100 Installation and operating instructions

Kessel

Kessel Staufix DA 100 Installation and operating instructions

Honeywell Elster Jeavons S100 manual

Honeywell

Honeywell Elster Jeavons S100 manual

Marmitek LM12AU user manual

Marmitek

Marmitek LM12AU user manual

Nordson A7A instruction sheet

Nordson

Nordson A7A instruction sheet

Lenze EPM-H310 operating instructions

Lenze

Lenze EPM-H310 operating instructions

Osram OT EASY 32 CC Fitting instructions

Osram

Osram OT EASY 32 CC Fitting instructions

Swegon Parasol evo II ma quick start guide

Swegon

Swegon Parasol evo II ma quick start guide

OHM PATCH PANEL PP-1 user manual

OHM

OHM PATCH PANEL PP-1 user manual

ABB ACH550 series quick start guide

ABB

ABB ACH550 series quick start guide

NuAire ES-UCF quick start guide

NuAire

NuAire ES-UCF quick start guide

Renishaw OMM manual

Renishaw

Renishaw OMM manual

Helm HM1525 instruction manual

Helm

Helm HM1525 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.