Half-bridge buck converter evaluation board
using the EiceDRIVER™ 2EDL8x2x
Order code: EVAL_HB_2EDL8x2x
About this document
Scope and purpose
The 2EDL8x2x is the EiceDRIVERTM family of level-shift high-side and low-side drivers with 120 V maximum boot
voltage. 2EDL802x takes in independent inputs while the 2EDL812x takes in differential inputs. Both have a 3 A
or 4 A peak source current capability for both high-side and low-side, and a strong 5 A high-side and 6 A low-
side sink current capability.
The half-bridge buck converter evaluation board described in this document is designed as a test platform for
evaluating the performance of 2EDL8024G.
Intended audience
Power supply designers, component engineers, hardware engineers, etc.
Table of contents
About this document....................................................................................................................... 1
Table of contents............................................................................................................................ 1
1Introduction .......................................................................................................................... 2
2Getting started with the hardware ........................................................................................... 3
2.1 Evaluation board.....................................................................................................................................3
2.2 List of connection and test points ..........................................................................................................4
2.3 Quick start guide .....................................................................................................................................4
3Test results............................................................................................................................ 5
4Addendum............................................................................................................................. 7
4.1 Schematic................................................................................................................................................7
4.2 Layout......................................................................................................................................................7
4.3 Bill of materials (BOM) ............................................................................................................................8
Revision history.............................................................................................................................. 9