Infinova V6202-TA Series User manual

INSTRUCTION MANUAL
V6202-TA Series
HD 1MP and 2MP Low Light IP Camera
Notice
Copyright Statement
This manual may not be reproduced in any form or by any means to create any
derivative such as translation, transformation, or adaptation without the prior
written permission of Infinova.
Infinova reserves the right to change this manual and the specifications without
prior notice. The most recent product specifications and user documentation for
all Infinova products are available on our web site www.infinova.com.
Trademarks
Infinova
® is a trademark of Infinova.
All other trademarks that may appear belong to their respective proprietors.
FCC Warning
The V6202-TA series HD 1MP and 2MP low light IP cameras comply with the
FCC rules.
Operation is subject to the following two conditions:
This device will not cause harmful interference.
This device must accept any interference received, including interference
that may cause undesired operations.
The V6202-TA series HD 1MP and 2MP low light IP cameras have been tested
and found to comply with the limits for a Class A digital device, pursuant to the
FCC rules. With these rules and regulations being obeyed to maintain the good
working condition of device, the operation is not supposed to be affected by
external interruptions under certain circumstances. This device is
electromagnetic, so all the installation and application processing along the
device has to follow strictly to the manual or it may hamper the
telecommunication around. Meanwhile, there is no guarantee that interference
will not occur in a certain particular installation situation.
Read this manual carefully before installation. This manual
should be saved for future use.
Important Safety Instructions and Warnings:
Electronic devices must be kept away from water, fire or high magnetic
radiation.
Clean with a dry cloth.
Provide adequate ventilation.
Unplug the power supply when the device is not to be used for an extended
period of time.
Only use components and parts recommended by manufacturer.
Position power source and related wires to assure to be kept away from
ground and entrance.
Refer to qualified personnel for all service matters.
Save product packaging to ensure availability of proper shipping containers
for future transportation.
Indicate that the un-insulated components within the product may carry a
voltage harmful to humans.
Indicate operations that should be conducted in strict compliance with
instructions and guidelines contained in this manual.
Warning: To avoid risk of fire and electric shock, keep the product away
from rain and moisture!
CONTENTS
Chapter I System Introduction ................................................................ 1
1.1 Product Description............................................................................... 1
1.2 Product Features.................................................................................... 1
1.3 System Requirement ............................................................................. 2
1.4 Product Model....................................................................................... 3
1.5 Specifications........................................................................................ 3
1.6 Notice.................................................................................................... 5
Chapter II Installation and PORT INTRODUCTION........................... 7
2.1 Installation Precautions ......................................................................... 7
2.2 Back Panel and Control Parts................................................................ 7
2.3 Dimensions ........................................................................................... 9
2.4 Installation of Camera........................................................................... 9
Chapter III IE Browser Settings.............................................................11
3.1 Equipment Connection........................................................................ 11
3.2 Software Installation ........................................................................... 11
Chapter IV Basic Function Operation................................................... 14
4.1 Live View............................................................................................ 14
4.2 System ................................................................................................ 17
4.3 Network Settings................................................................................. 23
4.4 Camera Settings .................................................................................. 32
4.5 Audio & Video Settings ...................................................................... 39
4.6 PTZ Functions..................................................................................... 48
4.7 Alarm Settings..................................................................................... 49
4.8 Record Management ........................................................................... 51
4.9 Account Settings ................................................................................. 55
4.10 System Log ....................................................................................... 57
Appendix I Magnetic Ring Filter Instruction ....................................... 59
Appendix II Questions & Solutions ....................................................... 60
Appendix III Cable Diameter Calculation and Lightning &
Surge Protection...................................................................................... 61

1
CHAPTER I SYSTEM INTRODUCTION
1.1 Product Description
V6202-TA series HD 1MP and 2MP low light IP camera adopts 1/3"
progressive scan CMOS sensor. H.264 High profile/M-JPEG video
compression format allows image output resolution up to 1920×1080@30fps or
1280×720@30fps.
The camera supports three simultaneous video streams, bi-directional audio and
G.711 audio compression. Functioned with ICR day/night switch, motion
detection, privacy mask, alarm input/output and local recording, V6202-TA
series is bound to enhance security and convenience for your CCTV
surveillance system.
With convenient ABF function, V6202-TA series camera is easy to debug and
install.
V6202-TA series is widely used in financial institutions, telecommunications,
governments, schools, airports, factories, hotels, museums, city streets and
other high-resolution surveillance applications.
1.2 Product Features
Infinova’s V6202-TA series camera has the following features and functions:
1/3" progressive scan CMOS sensor
IR-Cut Removable (ICR) Filter for Day/Night switching
Support Digital WDR function
Onvif Profile S
Sensitivity: 0.001 lux
Auto Back Focus (ABF)
High-resolution image signal output up to 1920×1080, with 1280×1024,
1280×960, 1280×720, 1024×768 and 800×600 optional (for V6202-TA2
series)
High-resolution image signal output up to 1280×720, with 1024×768 and
800×600 optional (for V6202-TA0 series)
2
Small bandwidth occupancy and high image quality
High frame rate transmission: up to 30fps
Three Simultaneous Video Streams: Dual H.264 & Scalable M-JPEG
Smooth dynamic video replay
Supports anti-reflection function
Bi-directional audio, G.711
Support storage with TF card
Up to four definable motion detection areas
Up to four definable privacy mask areas
Local Recording
2 alarm inputs, 1 relay output
Support multiple ways to handle alarms, such as email sending, FTP upload
and relay output
Support simultaneous multi-user access and parameter configuration via
Web Serve r
Compatible with Infinova’s V2216, V2218 and other digital video
surveillance software
Provide standard SDK, easily incorporated with digital surveillance systems
from a different supplier
Supports public access
With analog video debugging interface
Supports wide voltage, ESD and surge protection
1.3 System Requirement
Configuration of the computer to display image and control the camera:
CPU: Intel Pentium 4 2.4 GHz or above
RAM: 512 MB or greater
Network Port: 100M Ethernet port
Operating System: Microsoft Windows 7, Microsoft Windows XP
IE browser version: Microsoft Internet Explorer 6.0 or above
3
1.4 Product Model
This manual is for the following models:
V6202-TA024 Megapixel IP fixed camera, 1.0MPx, Day/Night,
Auto back focus, H.264/M-JPEG, 12VDC/24VAC
V6202-TA020 Megapixel IP fixed camera, 1.0MPx, Day/Night,
Auto back focus, H.264/M-JPEG,
PoE/12VDC/24VAC
V6202-TA224 Megapixel IP fixed camera, 2.0MPx, Day/Night,
Auto back focus, H.264/M-JPEG, 12VDC/24VAC
V6202-TA220 Megapixel IP fixed camera, 2.0MPx, Day/Night,
Auto back focus, H.264/M-JPEG,
PoE/12VDC/24VAC
1.5 Specifications
Model V6202-TA series
Image Sensor 1/3" progressive scan CMOS
Dynamic Range 72.4dB
Lens Mount C/CS
Auto Back Focus Available
Auto Iris DC driven
Day/Night
Functionality ICR
Sensitivity
For V6202-TA2 series,
Color mode: 0.05 Lux @ F1.2 (30IRE, AGC ON);
B/W mode: 0.01 Lux @ F1.2 (30IRE, AGC ON)
For V6202-TA0 series,
Color mode: 0.01 Lux @ F1.2 (30IRE, AGC ON);
B/W mode: 0.001 Lux @ F1.2 (30IRE, AGC ON)
Exposure Scene mode, Manual mode, Shutter priority mode
4
Shutter Auto/Manual (1/1s~1/13000s)
White Balance Auto/Manual/Incandescent light/Cool white fluorescent
light/Sun light/Cloudy/Natrium light
Gain Control Auto/Manual
Noise Reduction 3D
Video
Compression H.264 High profile/M-JPEG
Maximum
Resolution
1920×[email protected]4/M-JPEG (for V6202-TA2 series);
1280×[email protected]/M-JPEG (for V6202-TA0 series)
Optional
Resolution
Major stream: 1920×1080, 1280×1024, 1280×960,
1280×720, 1024×768, 800×600 (for V6202-TA2 series),
Major stream: 1280×720, 1024×768, 800×600 (for
V6202-TA0 series);
Minor stream: 720×576, 720×480, 640×480, 352×288,
352×240
Maximum Frame
Rate 30fps
Data Rate Variable bit rate;
Constant bit rate: 256Kbps~10000Kbps
Audio
Audio Compression: G.711-u;
1 input (Linear level, Resistance: 1000 Ohm),
1 output (Linear level, Resistance: 600 Ohm)
Motion Detection Up to 4 areas
Privacy Mask Up to 4 masks
Local Recording Available
TF Card Storage Available, up to 32G
Upgrade Online Available

5
Password
Protection Available
Network Port One RJ45 10/100M self-adaptive Ethernet port
Applicable
Protocols
IPv4, IPv6, TCP, UDP, IGMP, DHCP, FTP, SNMP (V3),
SMTP, NTP, RTP, RTSP, RTCP, HTTP, HTTPS, TSL, SSL,
802.1X, QoS, PPPoE, DNS, ARP, ICMP, UPNP, DDNS,
Profile S
Alarm 2 alarm inputs, 1 relay output
Power Supply PoE(IEEE 802.3af Class 2)/12VDC(10VDC~40VDC)
/24VAC
(
12VAC~40VAC
)
Power
Consumption
<5W (when the camera is focusing, the power
consumption will be less than 8W.)
ESD protection ±6KV(all ports)
Surge protection ±6KV(network port)
Operating
Temperature 14°F~122°F (-10°C~+50°C)
Storage
Temperature -4°F~140°F (-20°C~+60°C)
Operating
Humidity 0%-90% RH (non-condensing)
Dimensions
(H×W×L) 2.84"×2.97"×5.47" (72mm×75.5mm×139mm)
Box Dimensions
(L×W×H) 8.07"×4.92"×3.94" (205mm×125mm×100mm)
Unit Weight 1.21lbs. (0.55kg)
Shipping Weight 1.54lbs. (0.70kg)
1.6 Notice
1. Firstly perform network settings after login. The gateway IP address should
be set as that of the connected to the network camera.
6
2. The IP address is not allowed to conflict with that of other devices; otherwise,
you cannot visit the camera.
3. If the purchased IP camera utilizes PoE power supply, please connect
equipments according to the parameter of the Power Supply Switcher strictly.
Furthermore, practical test of maximum network cable length for the Power
Supply Switcher must be performed, so as to avoid the camera failure caused
by insufficient power supply of the Power Supply Switcher, or to avoid the
destruction of Switcher.
7
CHAPTER II INSTALLATION AND PORT INTRODUCTION
2.1 Installation Precautions
Do not drop the camera or subject it to strong knock.
Do not point the camera lens toward the sun or other strong light.
Do not install the camera in environment with temperature beyond the
acceptable range (from -10°C to 50°C), or with high humidity, direct
rainfall, frequent vibrations and shocks.
Add with auxiliary illumination device in case of low illumination to avoid
poor image quality.
2.2 Back Panel and Control Parts
Figure 2-1 Back View
①Alarm Input/Output, Audio Input/Output, RS-485 Terminal
②Network Port (used for PoE power supply)
8
③Analog Video Output ④TF Card Slot
⑤Network LED Indicator ⑥Back Focus Adjusting
⑦Reset ⑧Status LED Indicator
⑨Arrester ground terminal ⑩Power Input Terminal
Notes: The analog video is closed when the MJPEG video stream is enabled.
To enable the analog video, please close the MJPEG video stream.
On the left of camera body (face the lens to view), there is an IRIS connector.
The pin definition is as follows:
Note: The camera supports DC DRIVE. The default setting is DC DRIVE.
1
2
3
4
Figure 2-2
⑦Reset button: The camera supports short press and extended press reset
modes. If press and hold the button from 2s to 15s (i.e. short press), Power
LED Indicator will turn green, and camera’s parameters will restore the
default values. If press and hold the button more than 15s (i.e. extended
press), Power LED Indicator will turn orange, and camera’s system will
resume factory default settings. Power LED Indicator will flicker quickly
while holding time is about 15s. Note: if press “Reset” button, the IP address
will become to 192.168.1.100.
⑥Back Focus Adjusting button: Mount lens to the camera and install the
unit to the desirable place, then power on. Next, modulate the knobs on the
Pin DC DRIVE
1DAMP-
2DAMP+
3DRIVE+
4DRIVE-

9
lens to zoom and focus. If you cannot get clear image in this way, press ⑥
Back Focus Adjusting button to adjust focus automatically.
2.3 Dimensions
(Unit: inch, in the parentheses is mm)
2.97(75.5)
NETWORK CAMERA
5.47(139.0)
R
2.84(72.0)
Figure 2-3
2.4 Installation of Camera
When mounting the camera on fixer, pan/tilt, etc., use 1/4-20UNC screw and
the camera-mounting screw hole located on the camera-mounting bracket. The
camera-mounting bracket can be mounted on the top or at the bottom of the
camera. See the figure below:
10
Camera-mounting screw holes
Camera-mounting bracket fixing screw
holes (4 pcs)
Camera-mounting bracket
Figure 2-4 Camera-mounting Bracket
Note:
When installing the unit on a bracket, make sure to choose the suitable
position that can support the weight of the camera and the bracket in years
and fix them properly.
Exercise maximum caution when installing the unit to the wall or ceiling.
You should not engage in the installation work yourself. Ask a professional
to do the job, since the fall of the unit can result in injuries and accidents.
When installing the unit on a fixer, turn table, etc., make sure to install it
firmly using a mounting hole provided on the mounting bracket to prevent
fall.
As a failsafe against falling, attach the unit by chain, wire cable or other
safety restraint to an appropriate anchor point.
11
CHAPTER III IE BROWSER SETTINGS
When view the video, the user need to adjust the IE browser of the monitor or
other video devices, and set proper system function based on the following
instructions:
Support IE browser version: Internet Explorer 6.0 or above;
Must install InfiPlayerAX control and equip with Directx 9.0c.
3.1 Equipment Connection
V6202-TA series IP camera can be directly connected to a computer, or
connected to a network.
Note: Check whether the connection is tight or not before power-on.
3.2 Software Installation
The installation procedures of V6202-TA series camera image software are
listed as follows:
(1) Login
First, start IE browser and enter IP address. Enter user name and password in
the pop-up login interface.
The default IP address is http://192.168.1.100; the default subnet mask is
255.255.255.0 and the default gateway IP address is 192.168.1.254. For normal
access, correctly set local IP parameters before system login.
Do log in the system with the default super user for the first time to run the
software. The default Super User is admin (password: admin).
(2) Install and run Control
There are two ways to install control.
Method 1:
The prompt message as below will come out in live view window after a
successful login. Click the link to run, or store the exe file, then run it.
12
Figure 3-1
If the installation fails, check whether there is video viewed through other IE
window or page. You should close the video or the IE window directly.
If it successes, click refresh, you can view the live video.
Method 2:
The prompt message as below will come out in the page after a successful
login. Right click “Add-on Disabled” and select “Run Add-on”.
Figure 3-2
Then the prompt of security warning will pop up to remind the user to install
InfiPlayerAX control. Click “Install”.
Figure 3-3
After InfiPlayerAX control is installed, you can view the live video. If it pops
up reboot prompt, please cancel reboot. Then close all the IE window and
install InfiPlayerAX control once again. The live video will display as below:

13
Figure 3-4
Note:
If InfiPlayerAX control installation falls, the live video won’t display. Then,
you should change the IE security level.
1. Select “Tool” in the menu bar, and then select “Internet Options” from the
drop-down menu.
2. Select “Security” in the pop-up Internet options.
3. Click “Internet” icon and then click “Custom Level”.
4. Select “Enable” or “Prompt” in the options of “Download unsigned ActiveX
controls”.
5. Click Privacy in the “Internet”, clear “Block pop-ups”, then redraw the screen
and install control as per the prompt. The live video will display.
By now, the IE browser setting for image viewing comes to an end.
14
CHAPTER IV BASIC FUNCTION OPERATION
This chapter mainly introduces the settings and operation of V6202-TA series.
4.1 Live View
Start IE browser after the server is powered on for about 75 seconds, and then
enter IP address, such as http://192.168.1.100 (default), in the address field.
Note: The default subnet mask is 255.255.255.0 and the default gateway IP
address is 192.168.1.254. For normal access, please correctly set local IP
parameters before system login.
The login interface is displayed as shown in figure below in English operating
system.
Figure 4-1 User Login
Do log in the system with the default super user for the first time to run the
software. The system default Super User is admin (password: admin). Input the
correct user ID and password and then press “OK” button to login the system.
After login is successful, the following interface will display:
15
Figure 4-2 Live View
V6202-TA series IP camera supports H.264 and M-JPEG video compression
formats. After successful login, it enters H.264 major stream live video
interface. Users can also select H.264 minor stream or MJPEG from the
dropdown list of stream type. In the H.264 major or minor stream type, users
can do recording, snap shooting, and audio in/out settings. Over browsing
videos, users can also select a proper video scale.
Play mode: live or fluid for option.
Click the button to snapshoot and to enter the storage path. Default:
C:\InfiPlayerAX\Picture.
V6202-TA series supports local recording. Click the recording button to
16
start recording; when the button changes to , click it to stop recording.
During local recording, “REC”appears on the video screen. Click the
button to enter the recording storage path. Default: C:\InfiPlayerAX\
Video.
Users can set the snap shooting and recording storage path in the audio and
video settings interface.
Indicate audio input/output disabled. Click the buttons to enable audio
input/output and then the buttons will be shown as .
Indicate that the motion detection and privacy mask functions are
disabled. Click the buttons to enable them and then the buttons will be shown
as .
Note: only when motion detection or privacy mask is enabled, you can set the
corresponding function in Audio & Video Settings, refer to Section 4.5.3 or
4.5.4 for details.
PTZ control and PTZ function: When the camera is working with Pan/Tilt, it
is able to control the PTZ to perform such operations, such as direction
control, focus and zoom adjustment, and speed setting; Also, with PTZ
Function, wiper, defogger, presets, patterns, auto-pan and home return can be
called up.
Note: the login web page language should be set to the same as that of PC's
operating system.
Click the option tab “Settings” to enter the system setting interface.

17
Figure 4-3 Settings Interface
With the help of navigation menu on the left, Super user can perform the
following operations: Basic Information View, Time Settings and Advanced
Settings, Network Settings, Camera Settings (including Basic Set, Exposure,
Effect Set, White Balance, Focus, Reset), Audio & Video Settings, Alarm
Settings, Record setting, Account Settings (Add/Delete User, Change
Password), Log, etc.
Note: The following instructions are used for the super user.
4.2 System
Click the navigation bar [System] and it displays the following three option tabs:
System, Time and Advanced, as shown in Figure 4-3.
18
4.2.1 System Information
The initial interface of System Settings displays related system information,
such as basic system information, network settings, NTP settings, alarm settings,
H.264/MJPEG video settings, etc.
4.2.2 Time Settings
Figure 4-4 “Time” Settings
Time Zone Settings
Time Zone: Select the desired time zone in the scroll box, and then click “Save”
to save it.
There are 33 time zones for your selection.
If Daylight Saving Time is applied in your region, please turn on Daylight
saving time.
After settings completed, please click the button “Save”.
19
NTP Settings
Set the NTP server’s IP address, test NTP server’s status, and set parameters of
Sync with NTP, including enable/disable Sync with NTP, Sync time and Sync
interval.
After completed, please click the button “Save”.
Sync Now
There are two sync modes: local sync and NTP sync.
Local Sync means the system time is consistent with that of local PC. In the
NTP Sync mode, the system will automatically adjust time to the same as that
of NTP Server.
4.2.3 Advanced Settings
Figure 4-5 “Advanced” Settings
Software Update
Free software update is provided for V6202-TA series camera, and this update
service can reduce system maintenance budget.
Confirm the requirement submitted by user, we will provide the latest software
for download, and help user to update the V6202-TA series camera.
20
Follow the steps below to update software:
Click “Browse” button on the interface and the file selection dialog box will
pop up.
Figure 4-6
Select update file, and press “Open” button. The selected update file will be
displayed in the Software Update box.
After that, click “Submit” button to update software, the following information
will appear:
Figure 4-7

21
Click “Yes” button, run the program to finish the update.
The response time is due to the program type. You may wait a long time for
some program. Do not power off during the update process. Power-off will
make update fail, even damage the original program or unable to update again.
After update successfully, it needs to reboot the system. There is time prompt in
the web page during reboot. After reboot, it will skip to new web page to run
new program.
Note: Available only for the super user.
Factory Settings
V6202-TA series camera provides online reset function, which greatly
facilitates reset adjustment.
Select “Keep current IP unchanged”, click “Reset” button and the system will
pop up a message as below:
Figure 4-8
Click “OK”, all the parameters (excluding IP address) will be reset to the
factory default settings.
If “Keep current IP unchanged” is unselected, the IP address will be reset to the
factory default settings.
There is time prompt in the web page during reset. After reset, it will skip to
new web page.
If current IP unchanged, you can access web page directly. If IP address resets
to 192.168.1.100, you can’t access web page. Then, you have to set PC’s IP
address to 192.168.1 section, such as 192.168.1.25. After that, access web page
to change camera’s IP address and save, PC’s IP address will restore to the
22
corresponding section.
Note:
1. To avoid error happens, the operation of online reset function should be
performed under qualified personnel’s guide.
2. Default IP address is 192.168.1.100, and default subnet mask is
255.255.255.0.
3. Do not power off during reset, or else the reset will fail.
Online Reboot
Click “Reboot” button, the dialog box “This operation will take 75 seconds,
are you sure to continue?”pop up. Click “OK” and the system will restart.
There is time prompt in the web page during reboot. After reboot, it will skip to
new web page.
Note: Available only for the super user.
23
4.3 Network Settings
Click “Network” in the navigation bar, and the following interface will display:
Figure 4-9 Network Settings
11 options tabs are available: Network, FTP, SMTP, HTTPS, 802.1X, QOS,
IGMP, SIP, MDA, DDNS and UPnP.
4.3.1 Network Settings
IP mode: support both IPv4 and IPv6 modes. Network parameters are slightly
different under different IP modes.
24
Figure 4-10 Network Settings
Under IPv4 mode, users can enable or disable DHCP. When it is disabled, users
can set Unit IP address, Subnet mask, Gateway and DNS server IP address
manually.
Notes: The system indicator quickly flickers for 5s after the network settings
completed.
Users can also enable/disable PPPoE in this interface. If enabled, users can set
the user name and password.
V6202-TA series camera supports heartbeat function. In SNMP settings, set and
save the heartbeat sever IP address and Heartbeat interval, and then the
heartbeat package will be sent to the server or client, which greatly facilitates
the server or client to know about the camera’s network status.

25
4.3.2 FTP Settings
Figure 4-11 FTP Settings
V6202-TA series camera has the function of alarm associated with FTP upload
(alarm triggered image snapshot). Configure server IP, user name and password
in the FTP settings and activate FTP handling way in alarm settings, then alarm
triggered images FTP upload can be achieved.
4.3.3 SMTP Settings
Figure 4-12 SMTP Settings
User needs to set mail server, recipient, etc in SMTP settings interface.
Server IP: Set mail server address.
From: Set sender’s mail address.
To: Mail address of recipient.
CC: Mail address of the person copy to.
26
Authentication: Enable or disable authentication function. This function
should be set according to authentication requirements of mail server.
User name: Sender’s name, it can be set according to user’s needs.
Password: Set sender’s password.
After setting, click “Save” to take effect.
If user selects “mail” in “Alarm Settings” interface, system will send mails
according to SMTP settings.
4.3.4 HTTPS Settings
Figure 4-13 HTTPS Settings
V6202-TA series camera supports HTTPS protocol. You can import the CA
certificate in the interface.
4.3.5 802.1X Settings
Figure 4-14 802.1X Settings
V6202-TA series camera supports 802.1X protocol. You have to enable 802.1X
27
authentication when needed. Then, select an EAP method and enter the user
name and password.
4.3.6 QOS Settings
Figure 4-15 QOS Settings
There are 4 network Qos modes to be selected:
(1) Normal Service
(2) Max Reliability
(3) Max Throughput
(4) Min Delay
Recommend: Normal Service.
4.3.7 IGMP Settings
Figure 4-16 IGMP Settings
V6202-TA series camera supports multicast function. In the IGMP interface,
users can select the stream type and set the state, multicast IP address and RTP
28
port.
4.3.8 SIP Settings
Figure 4-17 SIP Settings
SIP Server: to configure SIP server for device;
SIP Server IP: the IP address of SIP server;
Port: the port number of SIP server;
Server ID: the ID of SIP server;
Device ID: the device ID used for registration with SIP server;
Alarm ID: the ID registered for device alarm;
Register Interval: the interval for re-registration of device in seconds;
Heat Beat Interval: the interval to send heartbeat information by the device in
seconds;
After configuration completed, click “Save” and the device sends a registration

29
request to the server.
Position Information: the mounting information or instruction for device.
Longitude: the longitude of mounting position, as precise to two places of
decimal;
Latitude: the latitude of mounting position, as precise to two places of decimal.
4.3.9 MDA Settings
Figure 4-18 MDA Settings
In MDA settings interface, you can set the Sever which the motion detection
alarm uploads to.
State: disable or enable motion detection alarm upload. When it’s on, you can
set camera name, user name, password, server IP and Port number. After setting
completed, click “Save” button to take effect.
30
4.3.10 DDNS Settings
Figure 4-19 DDNS Settings
Dynamic Domain Name System (DDNS) synchronizes the host name and
dynamic IP address continuously. Users don’t have to memorize the dynamic
IP address, but enter the dynamic domain name to connect the IP camera.
DDNS needs a PC with fixed IP address on the Internet to run the dynamic
domain name server.
Operation: select DDNS type in Enable option, enter the IP address of the
DDNS server into the address bar, configure domain name, user name, and
password and update time and then save the settings. Open the IE browser, and
enter the domain name to go to the query page of the device.
4.3.11 UPnP Settings
Create mapping between private network and the Internet via UPNP protocol.
Select UpnP option and enter the configuration page. The added mapping list
appears on the page.
31
Figure 4-20 UPnP Settings
In “Operation” column, means to delete; means to edit user
information.
Click Add button to add the mapping.
Figure 4-21
32
4.4 Camera Settings
Click “Camera” in the navigation bar to enter the interface shown as below:
Figure 4-22 Basic Settings
4.4.1 Basic Settings
You can set the following parameters:
Flicker frequency: 50Hz or 60Hz.
CVBS: It automatically changes with the flicker frequency. (Notes: analog
videos are shut off after MJPEG stream is enabled. To enable analog videos,
please disable MJPEG stream.)
Enable or disable backlight compensation or WDR.
Contrast Enhance: 1~6 levels match with 6 kinds of Gamma curve separately. If
it is set to Auto, the system will adjust automatically.

33
4.4.2 Exposure Settings
Figure 4-23 Exposure Settings
Exposure set, auto aperture, ICR control, ICR switch time, scene, AGC, shutter
speed and manual AGC can also be set in this interface.
Exposure Set: Manual, Scene and Shutter priority. In the Scene mode, indoor or
outdoor can be selected and AGC can be set (maximum 64X); if set to manual
34
mode, shutter speed can be set from 1/25s to 1/8000s and manual AGC can be
set to 1X to 64X, yet the scene and AGC are nonadjustable; if set to shutter
priority mode, the shutter speed and AGC can be set.
Auto Aperture: to enable or disable auto iris.
ICR Control: Auto mode, Night or Day. In Auto mode, the camera can
automatically control the day/night switching; in Day mode, videos are in color
mode; in Night mode, videos are in black/white mode.
AE target: set AE target level. It can adjust video brightness via AE target setup.
4.4.3 Effect Settings
In the Effect Settings interface, users can adjust the brightness, sharpness, hue,
contrast, saturation and 3D denoise in two ways: General or Mode, as shown in
the figure below:
Figure 4-24 Effect Set - General
35
Drag the sliding block to adjust the brightness, sharpness, hue, contrast,
saturation and 3D denoise.
Figure 4-25 Effect Set - Mode
The camera supports 6 video effect modes. Users can set and save Name, ICR
36
control mode and Scene parameters for each mode. Click “Factoryset” to
restore it to default settings.
The camera provides 7 Scene modes: Normal, Anti Fog, Motion, Entrance,
Natrium, Sharpen, USrMode. Each mode matches with a group of parameters, such
as brightness, sharpness, hue, contrast, saturation and 3D denoise.
In the Mode call, users can set effect mode call status and call period.
4.4.4 White Balance Settings
Figure 4-26 White Balance Settings
The camera has rich white balance modes, including Auto, Manual,
Incandescent light, Cool white fluorescent light, Sun light, Cloudy and Natrium
light. If set to manual mode, you can set the red gain and blue gain.

37
4.4.5 Focus Settings
Figure 4-27
The camera supports focus adjusting via web page. Click “Focus” in camera
settings interface to enter focus settings. Click button, the camera
will automatically focus once.
Left-click the image, the central area of the image will appear a green border,
and the camera will focus for this central area.
Manual focus: select Manual focus to enter the interface as below.
38
Figure 4-28
Click buttons to focus near; click buttons to focus far.
buttons mean to regulate sharply; buttons mean to regulate
slightly.
If “Relate ICR” is selected, the camera will automatically focus once when the
video changes between color and black/white modes.
If the camera cannot focus clear all the time, click button to restart
the motor.
4.4.6 Reset
Click button, you can change all the parameters in the camera page to
39
the factory default values.
4.5 Audio & Video Settings
Click the button in the navigation bar to enter the following
interface.
Figure 4-29 Video Settings
Click the related option tab to enter the setting interface.
4.5.1 Video Settings
Users can set the video parameters in the format of H.264 major or minor
stream and MJPEG stream, such as resolution, frame rate and IP rate.
Resolution:
For H.264 major stream, the resolution of V6202-TA2 series comes up to
1920×1080, with 1280×1024, 1280×960, 1280×720, 1024×768, 800×600
40
optional; while the resolution of V6202-TA0 series comes up to 1280×720, with
1024×768 and 800×600 optional.
For H.264 minor stream, the resolution comes to 720×576, 720×480, 640×480,
352×288, 352×240 and closed.
For MJPEG stream, the resolution of V6202-TA2 series comes to 1920×1080,
1280×1024, 1280×720, 720×480 and closed; the resolution of V6202-TA0
series comes to 1280×720, 720×480 and closed.
Frame Rate: the number of compressed frames produced by camera per
second.
The bigger the frame is, the better the image continuity will be, but the CPU
performance is lowered.
The smaller the frame is, the worse the image continuity will be, but the CPU
could handle more events.
The maximum frame rate for H.264 is 30fps. The maximum frame rate for
MJPEG is 10fps.
Note: the video settings of H.264 major/minor stream are linkage with that of
MJPEG stream. If H.264 major stream is set to 1080P/30fps, minor stream
closed, MJPEG is only able to set to1080P/4fps. If H.264 major stream is set to
1080P/25fps, minor stream closed, MJPEG frame is able to set to 10fps. Do
operate according to the prompt on the page.
GOV number: GOV number means the ratio of I frame to P frame in compressed
video images.
The bigger the value is, the less the data quantity is and the less network
resource it occupies.
Max. GOV number can be set to 60.
Bit Rate: There are 2 modes of bit rate: variable rate (vbr) and constant rate
(cbr).

41
The variable rate can adjust the bandwidth that it occupies automatically
according to the complexity of image, because the complexity of real video
sequence keeps changing, details, speed, etc, and the variable rate setting mode
can be used to choose how much bandwidth should be used. If the video gets
more details and moving fast, then it takes up more bandwidth to transmit, and
reversely it occupies less bandwidth. When the setting goes with constant bit
rate, then the image is transmitted under a constant bandwidth.
Bit Rate Upper Limit: You have to set the upper limit of bit rate if “vbr” is
selected; the stream size will be fixed if “cbr” is selected and the stream size is
defined in the “Bit Rate Upper Limit”. For major stream, the bit rate upper limit
can be 1000kbps~10000kbps; for minor stream, the bit rate upper limit can be
256Kbps~ 2000Kbps.
Image Quality: it can be set under MJPEG stream. Options: Highest, High, Average,
Low and Lowest. The higher the image quality is, the more bandwidth it will occupy.
42
4.5.2 OSD
Figure 4-30 OSD Mode 1
OSD settings include: Text OSD and Date OSD.
The camera supports two OSD modes: Mode 1, Mode 2. You can switch the
mode only if Text 2 is on.
Only if Text 1, Text 2 and Date OSD are set to “On”, you can set the text
content and the display position of text and date.
Context: Enter the text content in the box of Context, which allows up to 40
characters (lower/upper case letters and 0~9).
X-axis &Y-axis: The title axis location. Both X-axis and Y-axis can be any of
whole numbers from 0 to 99.
Font Size: Set the font size to be displayed. The bigger the value is, the larger
the font size is. Default as: 3.
43
After all settings finished, click “Save” button to display OSD on the video.
To cancel OSD, set it to “Off” and then click the button “Save”.
See the figure for OSD Mode 2:
Figure 4-31 OSD Mode 2
Only if Text 1, Text 2 and Date OSD are set to “On”, you can set the text
content and the display position of text and date.
Context: Enter the text content in the box of Context. Text 2 supports five-row
display and each row allows up to 40 characters (lower/upper case letters and
0~9).
X-axis &Y-axis: The title axis location. Both X-axis and Y-axis can be any of
whole numbers from 0 to 99.
Font Size: Set the font size to be displayed. The bigger the value is, the larger
the font size is. Default as: 3.
After all settings finished, click “Save” button to display OSD on the video.
To cancel OSD, set it to “Off” and then click the button “Save”.
44
4.5.3 Privacy Mask
V6202-TA series camera supports 4 privacy masks. If there is certain location
within the surveillance area where operators are not allowed to see, and thus,
Privacy Mask can be applied. System covers and shields the sensitive area via
Privacy Mask setting, to avoid operators observing certain sensitive locations on
monitor.
Note: do turn on privacy mask function in Live View interface before
privacy mask setting (see Section 4.1).
Figure 4-32 Privacy Mask Settings
How to set the privacy masks:
Tick the box of motion detection area number. Click the button “Draw” with
the mouse, press the left mouse button and drag on the video till a blue frame

45
displays on the screen. Then, click the button “Save” with the left mouse
button and the blue frame changes into black which indicates a successful
setting.
To cancel a privacy mask, just cancel the box ticking.
4.5.4 Motion Detection
Figure 4-33 Motion Detection Settings
V6202-TA series camera support motion detection. Users can easily set the
motion detection areas (up to 4) with the mouse.
Note: do turn on motion detection function in Live View interface before
motion detection setting (see Section 4.1).
46
Tick the box of Zone number to be set. If the motion detection area has been
set, a blue frame will be displayed on the screen.
How to set the motion detection area:
Tick the box of motion detection area number. Click the button “Draw” with
the mouse, press the left mouse button and drag on the video till a blue frame
displays on the screen. Then, click the button “Save” with the left mouse
button and the blue frame changes into green which indicates a successful
setting.
Besides, you can set the area name and sensitivity.
To cancel a motion detection area, just cancel the box ticking.
4.5.5 Shelter Alarm
Figure 4-34
V6202-TA series camera supports shelter alarm function. Users can easily set
the shelter alarm areas with the mouse.
At first, enable shelter alarm. Click the button “Draw” with the mouse, press
the left mouse button and drag on the video till a blue frame displays on the
47
screen. Then, click the button “Save” with the left mouse button and the blue
frame changes into green which indicates a successful setting.
Besides, you can set the area name and sensitivity.
It will trigger alarm when the video within the area is shielded. Refer to
Section 4.7 for alarm contact details.
4.5.6 Link Configure
Figure 4-35
For each stream, the total of 90 port and RTSP port is 5. In this interface, you
can set the video numbers of 90 port and RTSP port.
The default setting is visit 2-ch major stream, 2-ch minor stream and 2-ch
MJPEG video via 90 port and visit 3-ch major stream, 3-ch minor stream and
3-ch MJPEG video via RTSP port.
4.5.7 Storage Path
You can set the photo saving path and recording saving path in the following
interface.
Figure 4-36 Storage Path
48
Default photo saving path: C:\InfiPlayerAX\Picture.
Default video saving path: C:\InfiPlayerAX\Video.
Photo and video formats can also be set. The default photo format is .jpg and the
default video format is .avi.
To change the saving path, click the button “Browse” and select the path from
the popup dialog box.
4.5.8 Audio Settings
Figure 4-37 Audio Settings
Sample Rate: 8K.
Format: G.711-U.
4.6 PTZ Functions
Figure 4-38

49
When the camera is working with Pan/Tilt, you can set camera address, baud
rate and protocol in the interface. You can also set wiper, Pan/Tilt working
mode, preset, autopan, pattern, home return, and etc.
4.7 Alarm Settings
Click “Alarm” in the navigation bar to display the following Alarm Settings
interface:
Figure 4-39 Alarm Settings
Alarm Configuration
I/O In 1, I/O In 2: Settable 2-channel alarm inputs.
Each alarm input has 2 modes: Grounded Circuit or Open Circuit.
50
Alarm out Contact: used to set sending way of alarm.
Local Contact: I/O out is triggered by I/O alarm in, motion detection alarm,
shelter alarm, SD card out, network link down or IP address conflict. Default:
Local Contact.
Net Contact: I/O out is controlled by the surveillance management software.
Note: This function needs to be supported by digital video surveillance
management software like V2216. If Net Contact is selected, users have to set
Alarm Server IP the same as the IP address of V2216-CMS server. After
related setting to V2216 finished, users can remotely control the relay via
V2216 software. For detailed information, please refer to V2216 manual.
Alarm Server IP: used to set the IP address of alarm server. If alarm occurs, it
will inform the alarm server.
Alarm out Contact
Users can set the relevant alarm response ways for I/O alarm in, motion
detection alarm, shelter alarm, SD card out, network link down or IP address
conflict: Alarm out 1 (if Net Contact is selected, Alarm output 1 on the web
page is unavailable), SD card, Mail, FTP or Audio. After setting completed,
click “Save” button to take effect.
Note: when “FTP” or “Mail” is selected, you need to set FTP or SMTP
parameters in Network Settings, refer to Section 4.3.2 or Section 4.3.3 for
details.
Alarm Schedule
V6202-TA series camera can set the effective alarm schedule. Select the alarm
period (if Sunday is selected, alarm will be enabled during the set period of
each Sunday; if “everyday” is selected, alarm will be enabled during the set
period of everyday), and then, set the time period. Enter the start time and end
time in the 24-hour format. The end time must be larger than the start time.
51
4.8 Record Management
V6202-TA series IP cameras support storage with SD card. In the Record
Management interface, you can set the recording parameters, replay and
download the recorded videos.
4.8.1 Record Settings
Figure 4-40 Record Settings
Recording video type: Select the type of videos to record, major stream or minor
stream.
SD card when full: Overwrite or Stop. Overwrite means newly recorded videos
automatically overwrite the previous videos when the SD card is full; Stop means
recording stops when the SD card is full.
Recording mode: Alarm triggered, Always, Close. If alarm Triggered is selected, ,
also with SD card selected under alarm out contact in the alarm interface (refer to
4.7), recording is automatically triggered when alarm occurs.
52
You can view the total size, used space and state of SD card and also format it.
To remove SD Card when it is being used, please click “Reject”.
4.8.2 Replay
Figure 4-41 Replay
Video Search: set the start and end time, and then click the search button. All
videos recorded during this period of time will display in the list.

53
Figure 4-42 Searching Videos
Replay: to replay a video, double click a file in the list with the mouse or select
a file and then press the “Play” button . During playing, click or to
pause or stop playing.
Click the button on the right of video window, the right window will
disappear, show as below:
54
Figure 4-43
Click the button , the interface will restore.
Download: You can download the videos stored in the SD card to your PC.
Select the file from the video list (also you can select multiple files
simultaneously using the key “Ctrl” or “Shift”), and then click the button
“Download” to enter the downloading interface.
Figure 4-44 Downloading Videos
55
Save to: Set the path to save the downloaded files. If resetting required, click
the button “Browse”.
AVI/H.264 drop-down list box: select the downloaded file attribute.
In the download list, file total size, status and process will display.
Click the button “Start”, and then the files in the list will be downloaded in order.
The process shows 100% after downloading is finished.
Click the button “Open” to enter download content.
4.9 Account Settings
The default super user is admin (password: admin). Super user can add, delete
common user, and change the password of common users. Super user cannot
change his password. A maximum of 7 common users are supported.
Detailed instruction about how to add and delete user are addressed below.
Click the Account option tab in the Settings interface, the following account
information will display. The “Num” item shows the current user number. In
“Property” column, stands for super user; stands for common user. In
“Operation” column, means to delete; means to edit user information.
See figure below:
Figure 4-45 Account Settings
1. Add Users
(1) Click “ ”, enter the interface of “Add a User”.
56
Figure 4-46 Add a User
(2) Enter the desired User Name and Password (Note: User name and password
shall include letter, number and underline only. No special character is allowed.
The string length of user name is legal between 1 and 30 characters and that of
password is between 5 and 20 characters.)
(3) Click “OK” button. If the setting is successful, the new user name will
appear in the account list. Take new user “user1” as an example:
Figure 4-47
2. Delete Users
In the “Account setting” interface, click button of the “Operation” item to
delete user. The following dialog box will display:
Figure 4-48
Click “OK” button, the selected user would be deleted and the account list
would be automatically updated.

57
3. User Password Change
Click button in the account list, the dialog box of Edit User Information
will pop up:
Figure 4-49
Input the old password, enter the desired new password for twice and then click
“OK” button, the following picture will appear:
Figure 4-50
4.10 System Log
Click the “Log” option tab, the date, time and log information will appear on
the right of the screen.
58
Figure 4-51
It can display 30 logs on a page. The user can turn over the pages or skip to the
desired page by clicking the below arrows. Click “Delete logs”, a prompt will
come out. Then, click “Yes” to clear logs.
59
APPENDIX I MAGNETIC RING FILTER INSTRUCTION
To reduce electromagnetic interference that power supply generates, it is
necessary to install a magnetic ring filter with the power cable of Infinova
front-end IP device.
To install a magnetic ring filter with power supply:
Step 1: Open the magnetic ring filter and lead the power cable through.
Step 2: Wire the power cable on the magnetic ring filter 3 rounds or more
(Make sure the filter can be well closed).
Step 3: Close the magnetic ring filter.
Notice: The magnetic ring filter should be installed no more than 50 mm
away from the power output connector. As shown in Figure 3, the cable
length from A to B should be 50mm at most.
Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter
Figure 3 Power cable with magnetic ring filter
60
APPENDIX II QUESTIONS & SOLUTIONS
The following table describes the symptoms causes and solutions for the
problems.
Symptoms Possible Causes Solutions
The network
camera does
not perform
initiation after
power-on
Wrong power connection Reconnect power cable
Power supply failure Repair or replace power
supply
PCB fuse damage Replace the fuse
Immediate startup after
power-off
Restart 10 seconds later
after power-off
If PoE power supply is used,
too long transmission distance
may make the power of the
Power Supply Switcher
insufficient.
Shorten the length of the
power supply network
cable, or replace Power
Supply Switcher of larger
power
If PoE power supply is used,
connection to other electric
appliance makesthe ground
level not in the correct level.
Disconnect other electrical
appliance.
No video signal
displayed
The plug-in for viewing image
is installed incorrectly.
Refer to the Plug-in
Installation to reinstall it.
Network camera’s IP address
conflicts with other user’s IP
address
Set the unique IP address
Vague image Manual focus is not precise Manually adjust the camera
focus carefully.

61
APPENDIX III CABLE DIAMETER CALCULATION AND
LIGHTNING & SURGE PROTECTION
Relation between 24VAC Cable Diameter and Transmission Distance
In general, the maximum allowable voltage loss rate is 10% for AC-powered devices. The table below
shows the relationship between transmission power and maximum transmission distance under a certain
specified cable diameter, on condition that the 24VAC voltage loss rate is below 10%. According to the
table, if a device rated at 50W is installed 17-meter away from the transformer, the minimum cable
diameter shall be 0.8000mm. A lower diameter value tends to cause voltage loss and even system
instability.
0.8000 1.000 1.250 2.000
10 283 (86) 451 (137) 716 (218) 1811 (551)
20 141 (42) 225 (68) 358 (109) 905 (275)
30 94 (28) 150 (45) 238 (72) 603 (183)
40 70 (21) 112 (34) 179 (54) 452 (137)
50 56 (17) 90 (27) 143 (43) 362 (110)
60 47 (14) 75 (22) 119(36) 301 (91)
70 40 (12) 64 (19) 102 (31) 258 (78)
80 35 (10) 56 (17) 89 (27) 226 (68)
90 31 (9) 50 (15) 79 (24) 201 (61)
100 28 (8) 45 (13) 71 (21) 181 (55)
110 25 (7) 41 (12) 65 (19) 164 (49)
120 23 (7) 37 (11) 59 (17) 150 (45)
130 21 (6) 34 (10) 55 (16) 139 (42)
140 20 (6) 32 (9) 51 (15) 129 (39)
150 18 (5) 30 (9) 47 (14) 120 (36)
160 17 (5) 28 (8) 44 (13) 113 (34)
170 16 (4) 26 (7) 42 (12) 106 (32)
180 15 (4) 25 (7) 39 (11) 100 (30)
190 14 (4) 23 (7) 37 (11) 95 (28)
200 14 (4) 22 (6) 35 (10) 90 (27)
Power (W)
Diameter (mm)
Distance (ft / m)
62
Lightning & Surge Protection
The product adopts multi-level anti-lightning and anti-surge technology integrated with gas discharge tube,
power resistor and TVS tube. The powerful lightning and surge protection barrier effectively avoids
product damage caused by various pulse signals with power below 4kV, including instantaneous lightning,
surge and static. However, for complicated outdoor environment, refer to instruction below for lightning
and surge protection:
The product features with dedicated earth wire, which must be firmly grounded. As for surveillance
sites beyond the effective protection scope, it’s necessary to erect independent lightening rods to
protect the security devices. It’s recommended to separate the lightning rod from the mounting pole,
placing the rod on an independent pole, as shown in the figure below. If the product has to be installed
on the same pole or pedestal for lightning rod, there should be strict insulation between the video cable
BNC terminal, power cable, control cable and the standing pole of the lightning rod.
For suburb and rural areas, it’s recommended to adopt direct burial for the transmission cables.
Overhead wiring is prohibited, because it’s more likely to encounter lightning strike. Use shielded
cables or thread the cables through metal tubes for burial, thus to ensure the electric connection to the
metal tube. In case it’s difficult to thread the cable through the tube all the way, it’s acceptable to use
tube-threaded cables only at both ends of the transmission line, yet the length in burial should be no
less than 15 meters. The cable sheath and the tube should be connected to the lightning -proof
grounding device.
Additional high-power lightning-proof equipment and lightning rods should be installed for strong
thunderstorm or high induced voltage areas (such as high-voltage substation).
The lightning protection and grounding for outdoor devices and wires should be designed in line with
the actual protection requirement, national standards and industrial standards.
The system should perform equipotential grounding by streaming, shielding, clamping and earthing.
The grounding device must meet anti-interference and electric safety requirements. There should be no
short-circuiting or hybrid junction between the device and the strong grid. Make sure there’s a reliable
grounding system, with grounding resistance below 4Ω(below 10Ωfor high soil resistivity regions).
The cross-sectional area of the earthing conductor should be no less than 25mm².
Lightning rod
Front device
for surveillance
system
Separated layout for the lightning
rod and the standing pole
LPZOB
LPZOA
Mounting
pole for
front device
30° 30°
Infinova
51 Stouts Lane,
Monmouth Junction, NJ 08852, U.S.A.
Tel: 1-888-685-2002 (USA only)
1-732-355-9100
Fax: 1-732-355-9101
V1.3 1506
Table of contents
Other Infinova IP Camera manuals

Infinova
Infinova V6202IR-H02 Series User manual

Infinova
Infinova V1700N-NE2 Series User manual

Infinova
Infinova V5422IR-A8065ST-W User manual

Infinova
Infinova V6202-T00 Series User manual

Infinova
Infinova V6202-T03 Series User manual

Infinova
Infinova V6812IR-H0 Series User manual

Infinova
Infinova V5112IR-A8 series User manual

Infinova
Infinova V1700N-NE2 Series User manual

Infinova
Infinova V1492N-18N05 User manual

Infinova
Infinova V6812-T00 Series User manual