INIM Flex5/R Assembly instructions

Flex5/R5relayoutputsexpansionmoduleInstallationandprogrammingmanual
EN 50131-1
EN 50131-3
EN 50130-4
EN 50130-5
CEB T031

Table of contents
1.DescriptionofFlex5/R 3
1.1Descriptionofparts 4
1.2TechnicalspecificationsofFlex5/R 5
2.InstallationofFlex5/R 6
2.1Anti-tamper 6
2.2Flex5/Rboardconnections 7
2.3ConnectingtotheI-BUSline 9
2.4Flex5/Rproject 10
2.4.1AddressingofFlex5/R 11
2.4.2AddressingfromFlex5/R 11
2.4.3EnrollingofFlex5/R 13
3.ProgrammingofFlex5/R 15
3.1Programmingtheexpansionboards 15
3.1.1Expansionparameters 15
4.Generalinformation 16
4.1Aboutthismanual 16
4.2Manufacturer'sdetails 16
4.3SimplifiedEUDeclarationofConformity 16
4.4Warranty 16
4.5Limitedwarranty 17
4.6Documentsfortheusers 17
4.7Disposaloftheproduct 17
2Installation and programming manual- 101

Flex5/R| © 2021 Inim Electronics S.r.l. 3
1. Description of Flex5/R
Flex5/Risaperipheralthatprovides5terminalsforthecontrolofbothACandDCloads.
Eachterminalcanbeconfiguredinthecontrolpanelasarelayoutput,drycontactforDCandACdevicesup
toamaximumof10A.
Relay outputInthecaseofrelayuseoutputswithDCcurrents,itisadvisabletoconsultthefollowingdiagramsforthecor-
rectsizingofthesystemloadsbasedonthesuppliedcurrent:
Electrical endurance
Cycles
Switching DC current [A]
Maximum DC load breaking capacity
DC voltage [V]
Switching DC current [A]

1. Description of Flex5/R
1.1 Description of parts
D
C
B
E
[A]I-BUSterminals
[B]‘ENROLL’button
[C]LED‘P’(enrolling/settingaddress)
[D]LEDs‘L1,...,L5’(outputstatus/setting
address)
[E]Relayoutputterminals
LED signallingThe‘P’LED,duringtheautomaticenrollingphaseviathecontrolpanel,willblinkrapidly.
LEDs‘L1,...,L5’,duringnormalfunctioningofthedevice,indicatethestatusoftheoutputs:
lLEDon,relayactive
lLEDoff,relayinactive
Duringthemanualaddressingprocess,LEDs‘P’and‘L1,...,L5’indicatetheaddressoftheperipheral,in
accordancewiththetableprovidedinthedevice projectparagraph.
4Installation and programming manual- 101

Flex5/R| © 2021 Inim Electronics S.r.l. 5
1.2 Technical specifications of Flex5/R
1.2 Technical specifications of Flex5/R
Power supply voltage from9to15V
Current absorption 250mAmax
Relay features
Purelyresistiveloads: Max16A@230V~
Max16A@30V
Incandescentlamps: Max8A
Fluorescentlamps: Max0.5A
LEDlamps: 100W@230V~
30W@120V~
Electronictransformers: 4A
Motors(cosφmin0.6): 3.5A
Range of the voltage connectible to the OUTx output
Alternating Current from0to253V~,50/60Hz
continuous current
from0to253V @0.35A
from0to28V @10A
Operating environmental conditions
Temperature from-10to+40°C
Relative humidity ≤75%withoutcondensation
Security rating 2
Environmental class II
DIN-rail mount 5moduleenclosure
Dimensions (W x H x D) 88x90x58mm
Weight 180gr
(EN IEC 62368-1)
Isolation class
Terminal type + D S - ES1,PS2
OUT1, ..., OUT5 ES3,PS3

2. Installation of Flex5/R
2. Installation of Flex5/R
TheFlex5/RdeviceisDIN-Railmountcompatible.
ItmustbeinstalledinsideafireproofenclosurewithUL94-5Vflamabilityrating.
2.1 Anti-tamper
A
B
D
C
Theperipheralswithvisibleterminalsandwhichdonothaveananti-tamperdevicecanstillbeequipped
withprotectionbyinterveningontheassemblyprocedure.
Pleasenotethatinordertocomplywithsecuritystandards,allthecontrolpanelperipheralsmustbepro-
tectedagainsttamper.
Hereweprovideinformationononeofthepossibleproceduresthatcanbeadopted.Thisinvolvesthe
assemblyofamicroswitchonthedevice,whichsignalsanyattemptedtamper,andtheconsequentpro-
grammingoftheterminalusedforthiscontact.
1. Procureamicroswitchwithatleasttwonormally-opencontacts[A](preferablywith3contacts:COM-
NO-NC).
2. Employaterminalandprogramitasa‘24H’input,whosedescriptiontypeis‘Tamper’,balancedwith
asingle6K8Ω[B]resistance,unlimitedalarmcyclesandbelongingtoapartitionthatisviewableon
atleastonekeypad.
3. Using2wires,connectthemicroswitchtothe‘24H’inputterminal.
6Installation and programming manual- 101

Flex5/R| © 2021 Inim Electronics S.r.l. 7
2.2 Flex5/R board connections
4. Onthemicroswitch:
lidentifythecommoncontact(COM)andconnectitusingoneofthetwowires,totheGNDter-
minalofthe‘24H’terminal[C].
lidentifythenormallyopencontact(N.O.,whichisthecontactthatgeneratesashort-circuitbet-
weenthecontactitselfandtheCOMcontactwhentheswitchleveriscompressed)andcon-
nectoneendofthe6k8Ωresistortoit[D].
Connecttheotherendoftheresistancetothewirewhichisconnectedtothe‘24H’inputter-
minal.
5. Installthemicroswitchinsuchawaythatundernormalconditionstheswitchleveriscompressed.
Ifatamperattemptoccurs,theleverwillreleasethusgeneratingtheopeningofthecontactandan
immediatealarmonthe‘24H’terminal.
NoteThis wiring method can be applied in most situations, however, it is only a point of reference. In order to ensure
proper protection, you must always take in to account the specific mechanical and electrical conditions of the
device you are working on.
2.2 Flex5/R board connections
Asaperipheral,Flex5/Rmustbeconnectedtothecontrolpanelthroughtheavailable‘+DS-’terminals.
13.8V
I-BUS
UseoftheFlex5/Rtodriveroller-shuttermotors(single-phasebidirectionalasynchronousmotors)isachie-
vedthroughtheuseof2terminals.
Anecessaryconditionisthatthe2outputsusedhavetheinterlockfunctionactivebetweenthem.

2. Installation of Flex5/R
“N”
“L”
I-BUS
“N”
“L2”
“L1”
Terminalsthatcanhavetheinterlockfunctionactivatedbetweenthemare:
lthe‘OUT1’and‘OUT2’pair
lthe‘OUT3’and‘OUT4’pair
Attention!The mains line must be protected by a safety-standards compliant circuit breaker (trip
switch).
The circuit breaker (trip switch) must be located externally to the apparatus and should be
easily accessible.
The distance between contacts must be at least 3mm.
The manufacturer strongly advises the use of a magnetothermic switch with C intervention curve and maximum
nominal current - 16A.
The electrical earthing system of the site must be compliant with all safety standards and laws in force.
Be careful during the mains connection phase.
Danger of electric shock.
8Installation and programming manual- 101

Flex5/R| © 2021 Inim Electronics S.r.l. 9
2.3 Connecting to the I-BUS line
2.3 Connecting to the I-BUS line
TheperipheraldevicesofInimElectronicscontrolpanelsaretobeconnectedtothecontrolpanelviatheI-
BUS.
Theconnectionbetweenthecontrolpanelanditsperipheralsisachievedthroughashielded4wire(or
more)cable.
Attention!The shield must be connected to one of the ground terminals (or GND) only on the control
panel side and must follow the entire BUS without being connected to ground in other
points.
Thecontrolpanelconnectionisdoneusingterminals‘+ D S -’onthemotherboard.
SizingThesizingoftheI-BUSline,i.e.thedistributionofperipheralsandtheuseofcablestoconnectthem,must
bedoneonthebasisofvariousprojectfactors,inordertoensurethediffusionofthesignalsofconductors
‘D’and‘S’andthepowersuppliedbyconductors‘+’and‘-’.
Thefactorsare:
lThecurrentconsumptionoftheconnecteddevices.
InthecaseofinsufficientpowersupplyfromtheBUSlinetoperipheralsanddetectors(refertothe
Technicalspecificationstable),thiscanalsobesuppliedbyexternalpowersupplies.
lCabletype
Thecablesectionusedaffectsthedispersionoftheconductorsignals.
Cable
AF CEI 20-22 II number of conductors section (mm2) I-BUS terminal
4wirecable+shield
2 0.5 + -
2 0.22 D S
Recommended cable

2. Installation of Flex5/R
Cable
AF CEI 20-22 II number of conductors section (mm2) I-BUS terminal
6wirecable+shield
2 0.5 + -
2 0.22 D S
2 0.22 available
6wirecable+shield
2 0.75 + -
2 0.22 D S
2 0.22 available
lCommunicationspeedovertheBUS
Thisparametercanbechangedbymeansoftheprogrammingsoftware(38.4,125or250kbs).
BUS speed maximum admissible length
(sum of the sections downstream of the control panel or of an isolator)
38.4kbps 500m
125kbps 350m
250kbps 200m
BUS sizing
lNumberanddistributionofIB200isolators.
ToincreasethereliabilityandtheextensionoftheBUS,itisnecessarytouseisolators.
2.4 Flex5/R project
AfterinstallingthecontrolpanelperipheralsandconnectingthemtotheBUS,itisnecessarytoallowthe
controlpaneltorecognizeanddistinguishonefromanotherinorderforthemtobeplaced inthe con-
figuration.
Thisispossiblefirstlybyassigninganaddresstoeachperipheral.
Theaddressingprocedurechangesinaccordancewiththetypeofperipheral.Thetypesavailableare:
lkeypads(bothwithkeysandLCDdisplayandalsowithtouch-screens)
lproximityreaders(bothstand-aloneandintegratedintokeypads)
lexpansions(bothwithinput/outputandrelayterminals)
lsounder/flasher
lhome-automationmodules
lthermostats
lwirelesstransceivers
WarningPeripherals of different types can have the same address, whereas peripherals of the same
type must always have different addresses.
Wireless transceivers must have different addresses from those of readers and expansions.
Afterassigningalltheaddresses,itisnecessaryforthecontrolpaneltocarryouttheperipheralenrollingpro-
ceduresinordertoincludetheminthesystemconfigurationthatthecontrolpanelwillmanage.
10 Installation and programming manual- 101

Flex5/R| © 2021 Inim Electronics S.r.l. 11
2.4 Flex5/R project
2.4.1 Addressing of Flex5/R
Via keypadType in Code (Installer), PROGRAMMING EnrolPeripherals Peripherals
Thissectionwillallowyoutocarryouttheenrollingprocessintwodifferentways:
lbymanuallyenteringthe14-digitserialcodeshownonthepackageofthedevice
lbypressingthe‘ENROLL’buttononthedevice
Followingthisoperation,thedevicewilltransfertheserialcodetothecontrolpanel.
NoteAll the letters entered for the code must be uppercase.
Thecontrolpanelwillputforwardthefirstfreeaddressforthetypeofperipheralidentified.Theinstallercan
changethisaddressasdesiredorconfirmitbypressingtheOKbutton.
2.4.2 Addressing from Flex5/R
WhenconfiguringthedevicewithInimElectronicscontrolpanelsthatdonotsupportaprogrammingpro-
cesssuchasdescribedabove,itispossibletoassignanaddressmanually.
Thismethodrequirestheuseofthe‘ENROLL’buttonandLEDs‘L1’,...,‘L5’and‘P’.
Amaximumof100addressescanbesetinthisway.
Theproceduretobefollowedisasfollows:
1. Pressandholdthe‘ENROLL’buttonfor3seconds.
2. After3secondsthedeviceaccessesaddressprogrammingmode.
ThecurrentaddressisindicatedontheredLEDsinbinarymode,asshowninthetablebelow.
3. Eachtimethe‘ENROLL’buttonispressedtheaddressincreasesbyoneunit.
PressthebuttonrepeatedlyuntiltheLEDsindicatethedesiredaddress.
Ifnoactionistakenforover10seconds,thedevicewillexitautonomouslywithoutsettingtheselec-
tedaddress.
4. Pressandholdthe‘ENROLL’buttonfor3secondstoconfirmtheselectedaddress.
0LEDOff
1LEDOn
LFlashingLED
Address LED L1 LED L2 LED L3 LED L4 LED L5 LED P Address LED L1 LED L2 LED L3 LED L4 LED L5 LED P
10 0 0 0 0 1 51 1 1 0 0 1 1
20 0 0 0 1 0 52 1 1 0 1 0 0
30 0 0 0 1 1 53 1 1 0 1 0 1
40 0 0 1 0 0 54 1 1 0 1 1 0
50 0 0 1 0 1 55 1 1 0 1 1 1

2. Installation of Flex5/R
60 0 0 1 1 0 56 1 1 1 0 0 0
70 0 0 1 1 1 57 1 1 1 0 0 1
80 0 1 0 0 0 58 1 1 1 0 1 0
90 0 1 0 0 1 59 1 1 1 0 1 1
10 0 0 1 0 1 0 60 1 1 1 1 0 0
11 0 0 1 0 1 1 61 1 1 1 1 0 1
12 0 0 1 1 0 0 62 1 1 1 1 1 0
13 0 0 1 1 0 1 63 1 1 1 1 1 1
14 0 0 1 1 1 0 64 0 0 0 0 0 L
15 0 0 1 1 1 1 65 0 0 0 0 L 0
16 0 1 0 0 0 0 66 0 0 0 0 L L
17 0 1 0 0 0 1 67 0 0 0 L 0 0
18 0 1 0 0 1 0 68 0 0 0 L 0 L
19 0 1 0 0 1 1 69 0 0 0 L L 0
20 0 1 0 1 0 0 70 0 0 0 L L L
21 0 1 0 1 0 1 71 0 0 L 0 0 0
22 0 1 0 1 1 0 72 0 0 L 0 0 L
23 0 1 0 1 1 1 73 0 0 L 0 L 0
24 0 1 1 0 0 0 74 0 0 L 0 L L
25 0 1 1 0 0 1 75 0 0 L L 0 0
26 0 1 1 0 1 0 76 0 0 L L 0 L
27 0 1 1 0 1 1 77 0 0 L L L 0
28 0 1 1 1 0 0 78 0 0 L L L L
29 0 1 1 1 0 1 79 0 L 0 0 0 0
30 0 1 1 1 1 0 80 0 L 0 0 0 L
31 0 1 1 1 1 1 81 0 L 0 0 L 0
32 1 0 0 0 0 0 82 0 L 0 0 L L
33 1 0 0 0 0 1 83 0 L 0 L 0 0
34 1 0 0 0 1 0 84 0 L 0 L 0 L
35 1 0 0 0 1 1 85 0 L 0 L L 0
36 1 0 0 1 0 0 86 0 L 0 L L L
37 1 0 0 1 0 1 87 0 L L 0 0 0
38 1 0 0 1 1 0 88 0 L L 0 0 L
39 1 0 0 1 1 1 89 0 L L 0 L 0
40 1 0 1 0 0 0 90 0 L L 0 L L
41 1 0 1 0 0 1 91 0 L L L 0 0
42 1 0 1 0 1 0 92 0 L L L 0 L
43 1 0 1 0 1 1 93 0 L L L L 0
44 1 0 1 1 0 0 94 0 L L L L L
45 1 0 1 1 0 1 95 L 0 0 0 0 0
46 1 0 1 1 1 0 96 L 0 0 0 0 L
47 1 0 1 1 1 1 97 L 0 0 0 L 0
48 1 1 0 0 0 0 98 L 0 0 0 L L
49 1 1 0 0 0 1 99 L 0 0 L 0 0
50 1 1 0 0 1 0 100 L 0 0 L 0 L
12 Installation and programming manual- 101

Flex5/R| © 2021 Inim Electronics S.r.l. 13
2.4 Flex5/R project
2.4.3 Enrolling of Flex5/R
InimElectronicscontrolpanelsallowtheenrollingofperipheralsindifferentways,withachoicebetween
automaticormanualprocedures,dependingoninstalleraccesstothesystem.
Automatic, from control panel in ‘service’ modePlacingthecontrolpanelin‘maintenance’modeactivatesautomaticenrollingofperipheralsontheBUSat
intervalsof10seconds.
IftheinstallerassignsaddressestoperipheralsconnectedtotheBUS,at10secondintervals,thecontrol
panelwillenrollintheconfigurationtheperipheralsitfinds.
Automatic, from keypadAlternatively,itisalsopossibletostartanautomaticenrollingprocessbymeansofthefollowinginstaller
menuoptions:
Type in Code (Installer), PROGRAMMING Default settings, Auto enrolPeriphManual, via Prime/STUDIO software application
Oncethesolutionforthesystemtobedesignedhasbeenopened,clickonthe
System Layout buttononthemenuontheleft.Theninthesectionontherightclick
ontheAdd device on BUSbutton.
Awindowopenswhereyoucanselectthedevicestobeconfiguredandaddthemtotheconfiguration.
Inthesectionontheleftyoucanincreasethenumberusingthebuttoncorresponding
totheselecteddevicetype.
Toremoveadevicefromthestructure,workthroughtheAdddeviceprocedure,but
insteaddeselectthedeviceyouwanttoremove
Alternatively,youcanaccesstheprogrammingsectionbyclickingontherelevantbuttononthemenuonthe
left,andfromthelistthatappearsclickontheDeletebuttonthatcorrespondstothelineofthedevicetobe
removed.
Manual, via SmartLeague software applicationOncethesolutionofthesystemtobedesigned[A]hasbeenopened,intheright‘Design’tab[B],itispos-
sibletoselectaniconofthetypeofperipheraltobeconfiguredanddragittotherelevantpartofthetree
structureontheleft[C].
Alternatively,youcandouble-clickonthedeviceicontoaddittotheconfiguration.
Inthetreestructureontheleft,thenumbercorrespondingtotheselecteddevicetypeincreases.
Toremoveacomponentfromthetreestructure,selectitandpressCANConthecomputerkeyboard.

2. Installation of Flex5/R
Manual, from keypadTheenrollmentofaddressedperipheralsispossiblebyenablingthemenuoptionsafterreachingtheinstal-
lermenusection:
Type-in Code (Installer), PROGRAMMING Expansions, Enable/Disable
Inthissectionitispossibletoadd/removereadersfromtheconfiguration,bymeansofkeys‘ ’and‘ ’.
14 Installation and programming manual- 101

Flex5/R| © 2021 Inim Electronics S.r.l. 15
3.1 Programming the expansion boards
3. Programming of Flex5/R
TheprogrammingofFlex5/Rdevices,asperipheralsoftheInimElectronicscontrolpanel,canbecarried
outeitherviasoftwareorfromakeypad.
3.1 Programming the expansion boards
Via softwareByclickingonthe‘Expansions’buttononthemenuontheleft,thesectionontheright
willshowalistoftheconfiguredexpansions.
Selectingoneoftheoptionswillallowyoutoconfiguretheparametersofthesingleperi-
pheralbyclickingonthe button.
Via keypadType in Code (Installer), PROGRAMMING Expansions, ChoosePeripheral
Thissectionallowstheprogrammingofthevariousoptionsoftheselectedexpansion.
3.1.1 Expansion parameters
Parameter Software section Installer menu sec-tion
Description
Descriptionstringoftheexpansion(tobecustomizedbythe
installer).
Configuredexpan-
sions,selected
expansion
Expansions, Choo-sePeripheral, "expan-sion"
Sound on
output
Thisoptionthatenables/disablesthebuzzeroftheselected
expansionwhentherelevantT1terminalisactivatedasanout-
put. Expansions, Choo-sePeripheral, "expan-sion", OptionsDisable tam-
per pro-
tection
Thisoptionenables/disablestamperontheperipheral(ena-
bledbydefault).
Individual expansion parameters

4. General information
4. General information
4.1 About this manual
Manual code:DCMIINE0FLEX5R
Revision:101
Copyright:TheinformationcontainedinthisdocumentisthesolepropertyofInimElectronicsS.r.l..Copy-
ing,reprintingormodificationofthisdocument,inpartorasawhole,isnotpermittedwithoutpriorautho-
rizationinwritingfromInimElectronicsS.r.l..Allrightsreserved.
4.2 Manufacturer's details
Manufacturer:InimElectronicsS.r.l.
Production plant:Centobuchi,viaDeiLavoratori10
63076Monteprandone(AP),Italy
Tel.:+390735705007
Fax:+390735734912
E-mail[email protected]
Web:www.inim.biz
Thepersonsauthorizedbythemanufacturertorepairorreplacethepartsofthissystemhaveauthorization
toworkonlyondevicesmarketedunderthebrandInimElectronics.
4.3 Simplified EU Declaration of Conformity
Hereby,InimElectronicsS.r.l.declaresthattheradioequipmenttypeFlex5/RisincompliancewithDirective
2014/53/EU.ThefulltextoftheEUdeclarationofconformityisavailableatthefollowinginternetaddress:
www.inim.biz.
4.4 Warranty
InimElectronicsS.r.l..(Seller,Our,Us)warrantstheoriginalpurchaserthatthisproductshallbefreefrom
defectsinmaterialsandworkmanshipundernormaluseforaperiodof24months.
AsInimElectronicsdoesnotinstallthisproductdirectly,andduetothepossibilitythatitmaybeusedwith
otherequipmentnotapprovedbyUs;InimElectronicsdoesnotwarrantagainstlossofquality,degradation
ofperformanceofthisproductoractualdamagethatresultsfromtheuseofproducts,partsorotherrepla-
ceableitems(suchasconsumables)thatareneithermadenorrecommendedbyInimElectronics.Seller
obligationandliabilityunderthiswarrantyisexpresslylimitedtorepairingorreplacing,atSeller'soption,any
productnotmeetingthespecifications.InnoeventshallInimElectronicsbeliabletothepurchaserorany
otherpersonfor anylossordamagewhether directofindirectorconsequential orincidental,including
withoutlimitation,anydamagesforlostprofits,stolengoods,orclaimsbyanyotherpartycausedbydefec-
tiveproductsorotherwisearisingfromtheincorrectorotherwiseimproperinstallationoruseofthisproduct.
Thiswarrantyappliesonlytodefectsinpartsandworkmanshiprelatingtonormaluse.Itdoesnotcover
damagearisingfromimpropermaintenanceornegligence,damagecausedbyfire,flood,windorlightning,
vandalism,fairwearandtear.
16 Installation and programming manual- 101

Flex5/R| © 2021 Inim Electronics S.r.l. 17
4.5 Limited warranty
InimElectronicsS.r.l.shall,atitsoption,repairorreplaceanydefectiveproducts.Improperuse,thatis,use
forpurposesotherthanthosementionedinthismanualwillvoidthewarranty.ContactOurauthorizeddea-
ler,orvisitourwebsiteforfurtherinformationregardingthiswarranty.
4.5 Limited warranty
InimElectronicsS.r.l.shallnotbeliabletothepurchaseroranyotherpersonfordamagearisingfromimpro-
perstorage,handlingoruseofthisproduct.
InstallationofthisProductmustbecarriedoutbyqualifiedpersonsappointedbyInimElectronics.Instal-
lationofthisProductmustbecarriedoutinaccordancewithOurinstructionsintheproductmanual.
4.6 Documents for the users
DeclarationsofPerformance,DeclarationsofConformityandCertificatesconcerningtoInimElectronics
S.r.l.productsmaybedownloadedfreeofchargefromthewebaddresswww.inim.biz,gettingaccessto
ExtendedAccessandthenselecting"Certifications"orrequestedtothee-mailaddress[email protected]or
requestedbyordinarymailtotheaddressshowninthisdocument.
Manualsmaybedownloadedfreeofchargefromthewebaddresswww.inim.biz,gettingaccesstothereser-
vedarea,afterthelogin,andthentothesectionofeachproduct.
4.7 Disposal of the product
Informative notice regarding the disposal of electrical and electronic equipment (applicable
in countries with differentiated waste collection systems)
Thecrossed-outbinsymbolontheequipmentoronitspackagingindicatesthattheproductmustbe
disposedofcorrectlyattheendofitsworkinglifeandshouldneverbedisposedoftogetherwithgene-
ralhouseholdwaste.Theuser,therefore,musttaketheequipmentthathasreachedtheendofitsworking
lifetotheappropriatecivicamenitiessitedesignatedtothedifferentiatedcollectionofelectricalandelec-
tronicwaste.Asanalternativetotheautonomous-managementofelectricalandelectronicwaste,youcan
handovertheequipmentyouwishtodisposeoftoadealerwhenpurchasingnewequipmentofthesame
type.Youarealsoentitledtoconveyfordisposalsmallelectronic-wasteproductswithdimensionsofless
than25cmtothepremisesofelectronicretailoutletswithsalesareasofatleast400m2,freeofchargeand
withoutanyobligationtobuy.Appropriatedifferentiatedwastecollectionforthesubsequentrecyclingofthe
discardedequipment, itstreatmentand itsenvironmentallycompatibledisposalhelps toavoidpossible
negativeeffectsontheenvironmentandonhealthandfavoursthere-useand/orrecyclingofthematerialsit
ismadeof.

4. General information
18 Installation and programming manual- 101

Flex5/R| © 2021 Inim Electronics S.r.l. 19
4.7 Disposal of the product

Via dei Lavoratori 10, Loc. Centobuchi
63076 Monteprandone (AP) I
Inim Electronics S.r.l.
TALY
Tel. +39 0735 705007 _ Fax +39 0735 704912
DCMIINE0FLEX5R-101-20210526
Table of contents
Other INIM Control Unit manuals
Popular Control Unit manuals by other brands

rtd
rtd cpuModule CMC6686GX user manual

Xilica Audio Design
Xilica Audio Design XTouch Series: XTouch50 user manual

Ross
Ross HBB Series operating instructions

Kyocera
Kyocera KD205GX-LPU installation manual

JETStream
JETStream MAGJET X40 Product instructions

EOS
EOS ECON H2 Assembly and operating instructions