
2. Installation of Flex5/R
Cable
AF CEI 20-22 II number of conductors section (mm2) I-BUS terminal
6wirecable+shield
2 0.5 + -
2 0.22 D S
2 0.22 available
6wirecable+shield
2 0.75 + -
2 0.22 D S
2 0.22 available
lCommunicationspeedovertheBUS
Thisparametercanbechangedbymeansoftheprogrammingsoftware(38.4,125or250kbs).
BUS speed maximum admissible length
(sum of the sections downstream of the control panel or of an isolator)
38.4kbps 500m
125kbps 350m
250kbps 200m
BUS sizing
lNumberanddistributionofIB200isolators.
ToincreasethereliabilityandtheextensionoftheBUS,itisnecessarytouseisolators.
2.4 Flex5/R project
AfterinstallingthecontrolpanelperipheralsandconnectingthemtotheBUS,itisnecessarytoallowthe
controlpaneltorecognizeanddistinguishonefromanotherinorderforthemtobeplaced inthe con-
figuration.
Thisispossiblefirstlybyassigninganaddresstoeachperipheral.
Theaddressingprocedurechangesinaccordancewiththetypeofperipheral.Thetypesavailableare:
lkeypads(bothwithkeysandLCDdisplayandalsowithtouch-screens)
lproximityreaders(bothstand-aloneandintegratedintokeypads)
lexpansions(bothwithinput/outputandrelayterminals)
lsounder/flasher
lhome-automationmodules
lthermostats
lwirelesstransceivers
WarningPeripherals of different types can have the same address, whereas peripherals of the same
type must always have different addresses.
Wireless transceivers must have different addresses from those of readers and expansions.
Afterassigningalltheaddresses,itisnecessaryforthecontrolpaneltocarryouttheperipheralenrollingpro-
ceduresinordertoincludetheminthesystemconfigurationthatthecontrolpanelwillmanage.
10 Installation and programming manual- 101