Innotech GENII CSFCAH REM User manual

© MASS ELECTRONICS Pty Ltd 2006
Models:
GENII CSFCAH REM: Control Station with 3 Speed Fan
DS 15.10
August 2013
GENII CSFCAH REM
Control Station with 3 Speed Fan
Applications
Expands GENESIS Controller capabilities by providing a numeric output
display, numerical value input, a single toggle digital input switch and
three speed fan LED display output for distributed control via RS485.
Application Notes
A GENESIS Controller must have version 4 firmware installed to
support REM Modules. Version 5.0 or higher Config Soware must be
used to configure a GENESIS Controller that has CSFCAH REM Modules
connected to it.
One GENESIS Controller can have up to 15 GENII CSFCAH REM Modules*
connected to it via the REM comms bus.
For detailed connection information to the pre-version 5 GENESIS
Digital Controller Family, please refer to DS 99.03
Overview
The Innotech GENII CSFCAH REM Control Station Module with
3 Speed Fan is an expansion device for the GENESIS range of
Digital Controllers.
The module is powered by 24VAC and provides a limited User
Interface to the GENESIS Controller. There are no physical
connections between field equipment and the GENII CSFCAH
REM, all input/output values are edited and viewed on the wall
unit.
The GENII CSFCAH REM may be located remotely from the
GENESIS Controller providing a distributed User Interface for the
system.
The GENII CSFCAH REM is configured via the wallplate and
programmed via the GEN2Config Soware. The GENII CSFCAH
REM communicates with the Genesis Controller via the REM
Comms port. The remote link uses RS485 at a baud rate of
38400. For pre-version 5 controllers, a Gen II RMI Remote Module
Interface is required.
Please refer to DS 15.01 for further information.
Features
• One three decimal place numerical value input
• One three decimal place numerical output
• Two momentary digital inputs
• One LED digital display output
• Three ‘Fan Speed’ LED outputs
• Housed in a switchplate that mounts in standard electrical
wall plates
• RS485 interconnection between REM Modules
• 24VAC operation
• Wiring Diagrams for modules generated by GEN2Config
Soware
• Adjustable user input range
• Configurable power on settings
• LED indication of network traic on rear to ease debugging &
setup
Approvals
The GENII CSFCAH REM conforms to:
• EN 55011 Class B Group 1 & AS/NZS 2064:1997 for RCM
Labelling
• FCC Title 47 CFR, Part 15 Class A for FCC Marking
• UL listed to UL916, File Number E242628

© MASS ELECTRONICS Pty Ltd 2006
Page 2
DS 15.10 - GENII CSFCAH REM - Control Station with 3 Speed Fan
August 2013
Specifications
Power Supply
• Voltage: 24VAC ±10% @ 50/60Hz
• Power Consumption: 3VA max
The operating voltage must meet the requirements of Safety Extra Low
Voltage (SELV) to EN60730. The transformer used must be a Class 2 safety
transformer that has the energy and voltage limiting characteristics as
described in the National Electrical Code, ANSI/NFPA70. It must also be sized
and fused in compliance with local safety regulations.
Inputs
• Push buttons for adjusting control values
• Push button for toggling of “digital function”
• Push button for fan speed selection
Outputs
• No physical outputs
• Display of Temperature and Setpoint
• Display of Fan Speed
Terminal Identification
1 24VAC Supply
2 0VAC Supply
3 Earth
TERMINAL 3 is for the protection of the Comms circuitry and must
be connected to a good electrical bonded Earth.
COMMS Connection
SHLD 1 Shield from incoming Comms Cable.
+ RS 485 (+) signal.
- RS 485 (-) signal.
SHLD 2 Shield from outgoing Comms Cable.
Temperature Ratings
• Storage 0 to 50°C non-condensing
• Operating 0 to 40°C non-condensing
Enclosure
The GENII CSFCAH REM Modules are housed in switchplate that
mounts in standard electrical wall plates.
Colour: White
Mounting: Wall mounted
Installation
• The Cable run between the GENII CSFCAH REM and the GENII RMI
should not exceed 500 metres. The Comms wiring requires cable
especially suited for RS485. Other shielded cable is not suitable
and may cause spasmodic Comms failures.
• Strictly follow the guidelines when installing the Comms wiring as
outlined in the Genesis II Installation Manual.
• Mount the GENII CSFCAH REM in a dry and clean location free of
excess vibration.
The REM address must be set by programming Parameter 0.
Please refer to the Program Functions section of this data sheet
for more specific information regarding this.
Wiring
• The cable used for RS485 Comms must be shielded single
twisted pair, 120 ohms character impedence, 36 to 45pF per
metre capacitance between conductors.
• The Comms cable must be organised as a bus topology. That is,
starting at one end, devices are connected to it until the other
end of the cable is reached. No “stubs” are allowed. To connect
a device to the cable, as cut is made in the cable at the point
where the device is to be situated along it. Then, the two new
ends of the cable are wired into the device. The shields from the
two new ends are then terminated into the terminals marked
SHLD1 and SHLD2.
• Refer to the Genesis Network Installation Instructions for more
information.
FCC Class A Notice
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference received, including
interference that may cause undesired operation.
Note – This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense. Modifications to this
device, may void the authority granted to the user by the FCC to operate this equipment.

© MASS ELECTRONICS Pty Ltd 2006
Page 3
DS 15.10 - GENII CSFCAH REM - Control Station with 3 Speed Fan
August 2013
Program Functions On The GENII CSFCAH
REM
Start Programming Mode
To enter Programming Mode depress and hold the and
ON
OFF buttons for 5 seconds. The display will become blank
indicating that you are in the Programming Mode. Release both
keys and the display will show parameter 0.
Whilst in the programming mode the following buttons are
active:
ON
OFF Change to the next parameter.
Increase the current parameters value.
Decrease the current parameters value.
Parameter 0: Rem Address
The display will show current REM Address of the device.
• The range of address is 0 to 15
• The default address is 0
Parameter 1: Maximum Input Value
The display will show the Maximum Input Value to which the
module’s input can be set.
• The range of Maximum Input Value is 0.0 to 99.9
• The factory default setting is 30.0
Parameter 2: Minimum Input Value
The display will show the Minimum Input Value to which the
module’s input can be set.
• The range of Minimum Input Value is 0.0 to 99.9
• The factory default setting is 15
Exit Programming Mode
To exit the Programming Mode depress the ON
OFF and
buttons and the new setting will be saved.
Start Up Default Settings
The GENII CSFCAH REM Module can be set to start in any mode of
operation.
1. To set the start up default, adjust the GENII CSFCAH REM
Module to the desired settings and then press and hold the
ON
OFF and buttons for 5 seconds.
2. The display will become blank indicating that the new
settings have been saved.
Operating Functions On The GENII CSFCAH REM
Numerical Output
The GENII CSFCAH REM Module will display a 3 digit, single decimal place
analogue output value during normal operation.
Numerical Input
The GENII CSFCAH REM Module will provide a 3 digit, single decimal
place analogue input value to the GENESIS Controller during normal
operation.
This value can be modified by pressing the button to increase or
the button to decrease.
The value will increase or decrease by the least significant digit as set by
Parameter 3.
Momentary Digital Input Value
The ON
OFF button on the GENII CSFCAH REM Module provides a digital
input value to the GENESIS Controller during normal operation.
This operates as a standard momentary switch, i.e. Press the ON
OFF
button produces a momentary digital input to the GENESIS controller.
Digital Output LED
The GENII CSFCAH REM displays a digital state via the system LED during
normal operation.
Fan Speed Button
The ON
OFF button on the GENII CSFCAH REM Module provides a digital
input value to the GENESIS II Digital Controller during normal operation.
This operates as a standard momentary switch, i.e. Pressing the ON
OFF
button produces a momentary digital input to the Genesis II Digital
Controller.
Digital Fan Speed LEDs
The GENII CSFCAH REM displays the digital state of the fan speed via the
Fan Speed LEDs during normal operation.

© MASS ELECTRONICS Pty Ltd 2006
Page 4
DS 15.10 - GENII CSFCAH REM - Control Station with 3 Speed Fan
August 2013
RS485(-)
RS485(+)
RS485(-)
RS485(+)
RS485(-)
RS485(+)
YOUR DISTRIBUTOR
Australian Owned, Designed & Manufactured
by Mass Electronics Brisbane
Phone: +61 7 3421 9100 Fax: +61 7 3421 9101
Email:
[email protected] www.innotech.com.au
The INNOTECH device and the word INNOTECH are registered or unregistered trademarks of Mass Electronics Pty Ltd in Australia, USA and other countries
Other Innotech Controllers manuals
Popular Controllers manuals by other brands

DeVilbiss
DeVilbiss DVFR-3 Operation manual

Koganei
Koganei MSU-PH-EA Series owner's manual

Anaheim Automation
Anaheim Automation Bilevel Step Motor Driver BLD72 user guide

Johnson Controls
Johnson Controls SNC Series installation guide

Siemens
Siemens SITRANS LUT400 operating instructions

Rockwell Automation
Rockwell Automation Allen-Bradley MicroLogix Reference manual

Motortech
Motortech MIC500 operating manual

Victron energy
Victron energy BlueSolar PWM 12V/24V 30A manual

Lenze
Lenze 9350 operating instructions

SMC Corporation
SMC Corporation LECSB Operation manual

Renu Electronics
Renu Electronics FlexiPanels Basic HMI FP2-V2 Series user manual

National Instruments
National Instruments PXIe-8100 installation guide