Inscape Data Link Power LPS2400-T1 User manual

Page | 1
Link Power LPS2400-T1
Outdoor Industrial 4-Port PoE &
2-Port SFP Network Switch
USER MANUAL
Inscape Data Corporation
1620 Oakland Road, STE D101
San Jose, CA 95131
U.S.A.
© Copyright 2015, Inscape Data Corporation, All Rights Reserved. LinkPower, AirEther, AirGoogle,
and Inscape Data are trademarks of Inscape Data Corporation
Disclaimer: While every effort is made to ensure the information given is accurate, Inscape Data
Corporation does not accept liability for any errors or mistakes which may arise. All information and
specifications are subject to change without notice.

Page | 2
Certification
Inscape Data Corporation certifies that this product met its published specifications at time of
shipment from the factory.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
The user is cautioned that changes and modifications made to the equipment without approval
of the manufacturer could void the user's authority to operate this equipment.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user’s authority to operate
the equipment.
Industry Canada Statement
This Class A digital apparatus complies with Canadian ICES-003.
CE Statement
This product complies with the European Low Voltage Directive 73/23/EEC and EMC Directive
89/336/EEC as amended by European Directive 93/68/EEC.
Warning: This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.

Page | 3
Safety Summary
The following general safety precautions must be observed during all phases of operation of this
instrument. Failure to comply with these precautions or with specific warnings elsewhere in this
manual violates safety standards of design, manufacture, and intended use of the instrument.
Inscape Data Corporation assumes no liability for the customer’s failure to
comply with these requirements.
Before Applying Power
Verify that the product is set to match the available line voltage and all safety precautions are
taken.
Over Temperature Warning
To prevent the switch from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of (75°C). To prevent product cooling restriction, allow at
least 3 inches (7.6 cm) of clearance around the product after installation.
Ground the Instrument
To minimize shock hazard, the instrument chassis and cabinet must be connected to an
electrical ground. The instrument must be connected to the ac power supply mains through a
three-conductor power cable, with the third wire firmly connected to an electrical ground (safety
ground) at the power outlet. For instruments designed to be hard-wired to the ac power lines
(supply mains), connect the protective earth terminal to a protective conductor before any other
connection is made. Any interruption of the protective (grounding) conductor or disconnection of
the protective earth terminal will cause a potential shock hazard that could result in personal
injury.
When installing the unit, always make the ground connection first and disconnect it last.
Jewelry Removal Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings,
necklaces, and watches). Metal objects will heat up when connected to power and ground and
can cause serious burns or weld the metal object to the terminals.
Do not Operate in Explosive Atmosphere
Do not operate the product in the presence of flammable gases or fumes.

Page | 4
Chassis Power Connection
Before connecting or disconnecting ground or power wires to the chassis, ensure that power is
removed from the device. To ensure that all power is OFF, locate the circuit breaker on the
panel board that services the device, switch the circuit breaker to the OFF position, and tape the
switch handle of the circuit breaker in the OFF position.
Work During Lightning Activity
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Comply with Local and National Electrical Codes
Installation of the equipment must comply with local and national electrical codes
Do Not Exceed Input and Output Ratings
Do not operate the product to exceed the power input and output ratings.
This product Conforms to the following safety standards
Specification
Description
Regulatory Compliance
Products with the CE Marking are compliant with the 89/336/EEC
and 73/23/EEC directives, which include the safety and EMC
standards listed.
Safety
UL/CSA 60950
UL 60601-1
IEC 60950 with all country deviations
EN60950
EMC
FCC Part 15 Class A
CE Marking
Packing List
Each package includes the following items:
LPS2000 (1)
WM0001 Wall Mounting Kit (1)
AC Power Cable with one 3-PIN AC Power Connector (1)
User Manual (1)
Warranty Sheet (1)

Page | 5
Product Description
LPS2000-T1 Outdoor Industrial PoE Switch features with four PoE Ethernet ports and comply to
10/100/1000BaseT(X), IEEE802.3af PoE and two Gigabit SFP fiber optics interfaces. The power supply of
single PoE port can be up to 15.4W. The transfer data can be up to 120Km from SFP fiber port to a
control center. Additionally, the product also features with an anti-electromagnetic interference that
is designed for harsh outdoor applications and the 3KV network port surge protection can adapt to harsh
outdoor environment and ensure the reliability of the uninterrupted PoE operations. The outdoor
enclosure is rated at IP68, and the system is able to operate under -40 ~ +75 ˚ C temperature range.
Product Features
1. Comply to IEEE 802.3, IEEE
802.3u, IEEE 802.3z, IEEE 802.3ab, IEEE 802.3x, IEEE 802.1D, IEEE
802.3at, IEEE 802.3af, IEEE 802
.
1Q
IEEE
802.1p, IEEE 802.1x, IEEE 802.1W, SNMP, IGMP
s
t
andards
2. 10/ 100/ 1000M self-sensing RJ45 port, support PoE power supply f
unc
t
ion
;
All ports support
auto-flip (Auto
MD
I/
MD
I
X)
;
3. Each PoE port can provide power up to 15.4W per IEEE 802.3af standard
;
Supply power for
powered devices compatible with
I
EEE802
.
3a
f;
4. Support IEEE802.3x full duplex flow control and duplex
backpressure
flow
con
t
rol
;
5. 8.8G backplane
bandwid
t
h
;
6. 1K MAC address
t
able
;
7. Its 3KV network port surge protection can adapt to harsh outdoor
environmen
t;
Under the
temperature of -40 ~ +75 ˚C, working at a full load
240W;
8. The 2 gigabit SFP fiber ports are capable of high bandwidth and for up to 120KM long distance
t
ransmission.
Installation
a. Before installation, please ensure the following:
b. All PD devices, i.e., PoE Clients, meet the power requirement of the connecting devices.
c. All PD devices, i.e., PoE Clients, match with the power receiving device power pinout
specification (1/2+ & 3/6-)
d. Connect the power cable to a power source, 110 ~ 240V AC, then the switch will automatically
initialize, and LED lights status will display as following:
e. Except the POE port lights, all the other lights will go through the process of “on-off-on-off”,
which means the installation is successful.
f. Power LED remains ON
g. Connect the network devices with network cables to the POE switch port though the waterproof
connectors, then secure the Top Cover with the four screws to the Bottom Case
h. After the Ethernet and/or fiber optics network devices are connected, please refer the LED
Indicator Description Table Below on Page 6
Control Panel Diagram
Control Panel

Page | 6
LED Indicator Description Table:
Indicator
Status
Description
PWR
Indicator:
POWER
Green LED ON
Power On, Normal
LED OFF
Power OFF
PoE
Indicator:
PoE
Green LED ON
Connected PD Device, working properly
Green LED Blink
Short circuit or current overload
OFF
No Connected PD or Power OFF
10/1000
Indicator:
Link
OFF
No Connected PD or Power OFF
Yellow LED Blink
Data transmission properly
Yellow LED ON
Connected with 1000Mbps network device
L/A Indicator: Link/Act
Green LED Blink
Data transmission properly
Green LED ON
Connection is OK and data is being sent and received.
OFF
No data connected
NOTE: All PoE ports of PD devices are complying with IEEE802.3af/at standards per specific model
Connector Layout Diagram:
1. 2A –For Ethernet Network Cables
2. 2B –For 1 x Ethernet & 2 x Fiber Optic Cables
1. AC Power Connector
2. PoE & SFP Connectors
3. Vent Plug (DO NOT REMOVED)
Waterproof Ethernet, Fiber Optics, & Power Connector Assembly Diagram
Plastic Filler
Note: The Sealing Insert comes with one and three holes. The Plastic Filler MUST be used to cover the Sealing Insert, if
any of the hole is not used in order to maintain waterproof of the connector.
2A
2B
Fiber Optic
Cable

Page | 7
Optional Accessories
The following optional accessories can be order if required:
1. Mast/Pole Mounting Kit (Part No: MMK0001)
2. Ethernet Conduit Connector Kit (Part No: ECK0001)
3. Power Cable Conduit Connector Kit (Part No: PCC0001)
4. 30CM Plastic Ethernet cable conduit (2) (Part No. PECC0001)
5. 30CM Plastic Power cable conduit (1) (Part No. PPCC0001)
NOTE: Pole
Mounting Kit,
MMK0001, is an
optional accessory.

Page | 8
Contacting Inscape Data Sales and Support Offices
For more information about Inscape Data Corporation products, applications, support, and for a current sales office
listing, visit our web site: http://www.inscapedata.com
U.S. Headquarters
Here’s how to reach us if you’d like to place an order or if you have questions, concerns, or need support
Telephone
Postal Mail
North and South America
Customer Service and Orders:
Main: +1-408-392-9800
Fax: +1-408-392-9812
Monday - Friday
9:00 AM - 5:00 PM
Pacific Time UTC -7:00
Inscape Data Corporation
1620 Oakland Road, Suite D101
San Jose, CA 95131
U.S.A.
Table of contents
Other Inscape Data Switch manuals

Inscape Data
Inscape Data Link Power LPS1000 User manual

Inscape Data
Inscape Data Link Power LPS3400ATMP-T1 User manual

Inscape Data
Inscape Data Link Power LPS2400 User manual

Inscape Data
Inscape Data Link Power LPS2800-T1 Series User manual

Inscape Data
Inscape Data Link Power LPS3400-T1 Series User manual

Inscape Data
Inscape Data LinkPower LPS1800 Series User manual

Inscape Data
Inscape Data Link Power LPS2802-T1 Series User manual

Inscape Data
Inscape Data Link Power LPS1800-T1 User manual

Inscape Data
Inscape Data Link Power LPS3800-T1 Series User manual

Inscape Data
Inscape Data Link Power LPS3800-T2 Series User manual