Insignia GT9005 User manual

www.insigniarange.com Last Modied: 07/10/2014
INSTALLATION MANUAL
GT9005
ATTENTION INSTALLERS:
These instrucons must be
le with the customer
30 Day Technical Support: 01908 226545
(NOTE: This service is only available to customers from the day of delivery,
please have your supplier’s details and your postcode to hand before calling)
Replacements Parts: inside of your warranty contact:
www.insigniarange.co.uk/customerService.aspx
Spares/Replacements Parts: outside of your warranty
contact 0844 800 3069
www.insigniarange.co.uk
WARRANTY REG NO: __________________________
To claim your full 5 year warranty, register your shower within 90 days of delivery at: www.insigniarange.co.uk/
warrantyreg.aspx. Standard 12 month warranty applies if outside this me period.

www.insigniarange.com Last Modied: 07/10/2014
02
Contents
Introduction
Electrical Requirements
What’s In The Boxes?
Screw Pack Contents
Plumbing Requirements
Starting The Installation
Electric Box Connections
Steam Generator Connections
Sealing and Water Testing
MK117 Control Panel Instructions
Help Book Information
Parts List
3
5
6
7
8
9
22
24
25
26
27
28

www.insigniarange.com Last Modied: 07/10/2014
03
Thank you for your recent purchase of an Insignia shower. Please read this booklet with great care to ensure you get the best out of your build and have a shower that
will last for many years to come!
Like everything, in order to obtain a first class product that will serve you well for many years, the effort and correctness put into the assembly will reflect in the quality of
your finish.
OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK
1 Badge = Very easy
2 Badges = Easy
3 Badges = Moderate
4 Badges = Harder than average
5 Badges = Professional skills required
This shower is rated 4 Badges

www.insigniarange.com Last Modied: 07/10/2014
04
ASSEMBLY AND SIMPLE PLUMBING
THIS PRODUCT BUILD IS RATED SUITABLE FOR DIY PURPOSES PROVIDING THE CUSTOMER IS OF ABOVE AVERAGE SKILLS AND FEELS CONFIDENT IN
THEIR ABILTY. ONLY YOU THE CUSTOMER WILL KNOW THIS SO BEFORE ANY ATTEMPT IS MADE TO ASSEMBLY READ THROUGH THE FOLLOWING
PAGES IN DETAIL THEN DECIDE. IF YOU HAVE ANY DOUBT USE THE SERVICES OF A PROFESSIONAL. IN PICKING SUCH, ALLOW THEM TO DECIDE IF
THEY ARE CAPABLE OF BUILD BY FIRST SHOWING THESE INSTRUCTIONS TO THEM. ALWAYS GET THREE QUOTES.
REMEMBER THE BEST IS NOT ALWAYS THE CHEAPEST!
REMEMBER PLUMBERS PLUMB! 90% OF THIS JOB IS NOT PLUMBING!
DUE TO THE NATURE OF THIS PRODUCT WE HIGHLY ADVISE THE PURCHASE AND FITTING OF A WATER SOFTENER
ELECTRICAL CONNECTION TO HOUSE MAINS
WHEN YOUR ITEM IS ASSEMBLED ALWAYS USE THE SERVICES OF A FULLY QUALIFIED ELECTRICAL COMPANY TO COMPLETE CONNECTION FROM
SHOWER TO HOUSE SUPPLY. LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID REGARDS ELECTRICAL ITEMS IF THIS IS NOT
UNDERTAKEN.
YOURS AND OTHERS SAFETY IS PARAMOUNT. NEVER ATTEMPT THIS YOURSELF.
REMEMBER:
These showers are designed to be free standing and movable from their location should you have need to replace anything. ALWAYS USE Flexible braided water inlet
pipes at least a metre long (not central heating plastic type! )
from house supply to the shower and again flexible waste pipe to join to your house waste. NEVER fix with rigid pipes, never fix the unit to the wall.
DURING BUILD, LIKE ALL SHOWERS CORRECT SEALING IS IMPERATIVE.
ATTENTION
ALWAYS FIT EASY TO GET TO TAPS ON BOTH HOT AND COLD WATER SUPPLY. AS A DISHWASHER OR WASHING MACHINE, THIS
PRODUCT MUST BE ISOLATED WHEN NOT IN USE. FLEXI SUPPLY HOSES (SUPPLIED) COUPLE HERE AS ORIGIN OF SUPPLY

www.insigniarange.com Last Modied: 07/10/2014
05
YOU WILL NEED
TOTAL ELECTRICAL REQUIREMENTS
Voltage Rating 220 -240AC
Frequency Rating 50HZ
Power Rating 3.0KW
Other than steam generator
Internal Circuit Voltage is 12V
Internal Current Rating 0.17A
Your electrical contractor should understand ALL legal requirements of connection before undertaking any work or installation.
UNDER NO CIRCUMSTANCES UNDERTAKE THIS YOURSELF!!!
Note for electrician. This product comes with 13 amp plug(s) fitted with an RCD unit. We leave it this way for you to connect this your own way due to continued additions
to current regulations. As at October 2010 we offered two methods.
1) Connect within current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version
2) (Preferred) Wire into isolated fused feed connecting directly to the house consumer/service box. Remove the fitted plug and ensure the Consumer unit has capabilities to
replace RCD feature if RCD is removed.
Always use protection against electrical surge. Your shower should be treated the same as a home computer. A surge protector should eradicate the possibility of either
the transformer or computer control being burnt out. Please note earth is required and found on chassis of shower tray. A further earth is required from Steam Generator
unit. Each earth must ground through power supply line.
Requirements
Scissors Stanley Blade Silicone Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill

www.insigniarange.com Last Modied: 07/10/2014
06
Whilst the next steps show you how to assemble your shower we want to make sure you have a correct build to ensure you get a trouble free shower. Therefore our advice
is to follow the instructions and perform a dry run to ensure you are confident with the build and you understand fully how the unit is assembled. When we use the word
“DRY RUN” this means you do not silicone anything, just simply construct the shower, align, drill and screw everything together. Once you are happy with the build take the
unit apart and carry out the final fix.
What’s In The Boxes?
Tray Box
1x Tray
1x Roof
Accessory Box
Glass Room
2x Rear Door seals
2x Magnetic Door seals
2x Glass doors
2x fixed glass
2x Rails
Column
2x Complete Column (one with control panel)
Backwalls
1x Left Panel Backwall
1x Right Panel Backwall
1x Back Mirrored Panel

www.insigniarange.com Last Modied: 07/10/2014
07
Insignia Screw Pack
VERY IMPORTANT
Have you got everything? If not please contact the Insignia Support Line on 01908 226545. Remember NEVER book your tradesman until everything has arrived, been
checked and is present. No replacement/missing parts can be obtained free of charge during or after the build. Any claims can only be within the timescale permitted (48
hours after delivery) and always BEFORE build.
Note: In some cases you may have more screws than needed, this is done so you have spares!
Product Code Descripon Quanty
SP097 Door Handles 2
SP008 White Door Wheels 8
ST20 20mm Screws 20
ST35 35mm Screws 10
ST14 14mm Screws 20
ST25 25mm Screws 10
SW9 Small Washers 20
DB6 Drill Piece 1

www.insigniarange.com Last Modied: 07/10/2014
08
Pressure Requirements from your house supply
We recommend a bar pressure between 2.5 and 3.4 BAR. If you have a combi boiler system no problem should be experienced. If you have a gravity feed older type
installation (hot water tank type usually less than 1 bar) you will almost certainly need a pump. We cannot advise on which type of pump is used, location or design because
all house plumbing layouts vary. This is a job for your installer/plumber. The end delivery however must fall within the scope above.
Debit Requirements
You will need the debit capabilities of at least 10 litres per minute. Again an average combi boiler will supply this but please check if you have a gravity feed system.
Important Note Do not exceed 3.4 BAR pressure under any circumstances. Warranty is void if so as damage will occur. If you have a combi supply, please use a pressure
reducing valve if required to lower the BAR pressure to the shower.
Please Remember that this product is free standing and is designed to be pulled away from the wall. The water supply and waste require flexible pipes. If you purchased the
fitting kit with this shower you will have the required fittings. The water supply pipes need to be at least 1 metre in length and must be that of a flexi braided type..
DO NOT OVERTIGHTEN IT CAN CAUSE THE CONNECTION TO POP AFTER A FEW WEEKS OF USE
Please note if a shower pump is used via gravity system we recommend a separate cold feed bypassing pump direct to generator to avoid damage to the
generator.
Further to this as you would with a washing machine or dishwasher, it is highly recommended that accessible water valve taps are installed to turn off the shower when not
In use. This will avoid any possible flooding due to a burst pipe or connection failure in the future.

www.insigniarange.com Last Modied: 07/10/2014
09
TO START
Make sure you have a clear space, remember when finished and in place you need access to check your build and able to pull the shower out for servicing or should you
have the need to replace anything!
Take the shower tray and remove all the protective wrapping and fit the waste. If you purchased the fitting kit it is possible this may have already been fitted in the tray hole
yet please note this is only for transportation reasons therefore you will still need to ensure the correct sealing and alignment is carried out. In the side of the waste supplied
in the optional fitting kit you will notice a spigot not seen on an ordinary waste. In most cases this is blanked yet should you have a steam version you need to gently drill this
out as this item is for the steam generator drainage and will be connected in the instructions later.
Now please level the tray by firstly placing the tray in its final location and then using a spirit level, adjust the tray feet accordingly. Once you are happy with the levelling of
the tray, you can pull it out to begin the main construction.

www.insigniarange.com Last Modied: 07/10/2014
10
Step 1
Attach the left glass panel to the left column (without control panel)
using the ST20 screws. Ensure you run a bead of silicone between
the 2 panels and under the bottom of both panels
Step 2
Attach the large back panel to the left column using the ST20 screws and again
ensuring you run a bead of silicone between the 2 panels and under the large back
panel.

www.insigniarange.com Last Modied: 07/10/2014
11
Step 4
Attach the right glass panel to the right column (with control panel) using the ST20
screws and place a bead of silicone between the 2 panels and the tray.
Step 3
The next step is to attach the remaining column (with control panel) to back
mirrored panel using the ST20 screws as shown in the picture to the left and
again ensure a bead of silicone is placed between the panels and again
under the bottom of the control panel.

www.insigniarange.com Last Modied: 07/10/2014
12
Step 6
Next attach the “U shape” rubber glass seal to the outer edge of the front
fixed glass panels and cut any excess of if
required.
Step 5
Attach both uprights to your top and bottom rails using the
ST35 screws
IMPORTANT
If your front fixed glass has 2 black uprights pre-fitted please bypass steps 6 and 7
Please note the wide upright is the outer upright and the cut out sits on the tray side.

www.insigniarange.com Last Modied: 07/10/2014
13
Step 7
With the frame now attached to the back panels, locate and fix the
glass panels into place by pushing them as per the arrows in the
adjacent image Making sure the edge of the glass with the rubber seal
fits into the grove tightly.
Using the ST14 Screws and the SW9 washers secure the uprights
from the inside of the shower in to position. You will need to do this for
both the top and bottom of each column.

www.insigniarange.com Last Modied: 07/10/2014
14
Step 8
Place and screw the upright curves into position using the ST20
screws and SW9 washers as indicated by the images.

www.insigniarange.com Last Modied: 07/10/2014
15
Step 9
Ensure the back panels are square and you are happy with their final position.
Now meet the front frame to the side panels as per the image and screw together using
the ST25 screws and SW9 washers. We recommend a bead of silicone is placed under
the front frame to add to the rigidity of the shower and the overall sealing.
before finally securing it in position to aid with the sealing of the shower.

www.insigniarange.com Last Modied: 07/10/2014
16
Step 10
Now align the roof to the glass panel and secure into position using the ST20 screws and repeat
this process to fix the glass panels to the tray as indicated by the image.

www.insigniarange.com Last Modied: 07/10/2014
17
Shelf
Fix the chrome floating shelf brackets to your glass back panel by using the provided screws. Now attach the chrome tubed bars to your glass shelf as illustrated in the
below image. Next slide the shelf into your shelf brackets and secure by tightening the grub screw situated on the bottom of the bracket.
Accessory Installation
Please Note
Ensure all grey backing film on the rear of the glass panels are pierced through the existing glass holes
with a knife to provide an efficient smooth fitting and location of the accessories. We recommend using
a screwdriver on the smaller holes.
Steam Pod
Insert the pod from the inside of the shower and attach
large white nut rom the rear.
.
x2
Foot Massager
Fix the provided white plastic foot massage retaining knobs to your glass back
panel along with your chrome water outlet as shown in the image.

www.insigniarange.com Last Modied: 07/10/2014
18
Ozone (o3)
Unscrew the chrome pepper pot end and drop
the white box upside down into the rear hole as
shown in the image. Now from the inside of the
shower re-attach the chrome pepper pot end
and tighten.
Monsoon Head
Attach the grey hose from your valve to the inner black tube using PTFE
tape (please note this only needs to be hand tight.
Over tightening will snap/damage the inner black tube)
Thermostatic Probe
Insert the chrome sleeve into the hole situated below
the control panel and secure in place with the retaining
nut. Insert the rubber grommet into the sleeve and push
the probe through from the rear of the cabin ensuring
the probe protrudes no more than 6mm. Place a small
amount of silicone behind to fully secure in to place.

www.insigniarange.com Last Modied: 07/10/2014
19
Wheels
Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels
are at their lowest position and hang on the inner curved rails with the wheels facing the
outside of the glass.
Once all wheels are fitted and on the rails you can adjust the wheels by turning the plastic
bolt clockwise in which in turn will pull the wheels towards the track ensuring a secure a
tight fit.
Now grease the track to ensure a smooth and long lasting operation
(not supplied)
Handles
Ensuring that the inner thread is protruding out from the handle far enough, place
the handle on the outside of the door and secure by tightening the inner chrome
knob to the protruding inner thread.
Door Seals
Magnetic Seal: Push the magnetic door seal on the handle side of the glass door
ensuring this is tightly fitted.
Rear Door Seal: Place the rear door seal on the opposite side to the magnetic strip
ensuring the flap is facing the fixed glass panel

www.insigniarange.com Last Modied: 07/10/2014
20
Hand Shower
Shower Valve(s)
Connect the hoses to the corresponding inlets on the back of the shower. We suggest using tape thread to ensure a water tight seal.
Device output may differ from the image. Please refer to your outer chrome faceplate inside your Insignia shower as a reference point.
IF YOUR DIAL DOES NOT CORROSPOND TO THE APPROPRIATE DEVICE:
Turn on your water to the shower and note which output the water exits from then turn off the water and swap over the relevant hose.
Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub screw (please ensure not to unscrew fully as this will drop within the
chrome knob) this is found on the opposite side to the chrome pillar. Once you have succeeded in loosening this you can now slide your faceplate to correspond to
the device.
Monsoon Shower
Open Outlet For
Steam Generator
Le Column
Cold Water Inlet Hot Water Inlet
Body Jets Hand Shower
Foot Massager
Capped off
Right Column
Cold Water Inlet Hot Water Inlet
Body Jets
The columns
market Left and
Right are
pictured looking
from the back of
the shower
Table of contents
Other Insignia Other manuals
Popular Other manuals by other brands

POWERWINCH
POWERWINCH 315 operating instructions

Orbinox
Orbinox AG STOP GATE Installation, operation and maintenance manual

Digital Watchdog
Digital Watchdog CP-01 instruction manual

BINZEL-ABICOR
BINZEL-ABICOR BRS-CC operating instructions

Omron
Omron V700-HMD13 series user manual

curt
curt 11376 installation instructions