A1000 is a simple & easy to use GSM Detector which sends SMS and calls you in case of alarm events.
Alarm event occurs in case of NO and NC ports changes. Up to 3 users can be registered.
Only a local GSM SIM card is required to operate the device.
A1000 operates with both batteries and power adaptor.
A1000 also operates as Power Failure Detector. Sends you POWER FAIL message in case of power adaptor fails
and sends you POWER OK message in case of power restored.
Once battery is low, device sends you LOW BATTERY message and sends you weekly KEEP ALIVE messages.

2. Getting started
2.1. Insert SIM Card
A local SIM card is required to operate the system. Before inserting the SIM card, try it with a mobile phone and:
• Disable PIN code protection
• Send an SMS to a mobile number for testing
After above steps; please open the screws on the back of the item and please insert SIM card into your device.
2.2. Connect Devices on Ports
NO PORT (Port1): Connect two wires of your NO type device output or cable into terminal block 5 & 6.
short-circuit between terminal 5 & 6.
NC PORT (Port2): Connect two wires of your NC type device output or cable into terminal block 7 & 8.
open-circuit between terminal 7 & 8.
Device provides required voltage by itself. Do not apply any external power on these terminal blocks
which might cause damages. Also make sure that your external device does not apply any voltage, or sink
or sank any currents. Your external device should only provide a relay output or short or open circuit.
2.3. Connect Power
Connect 12V DC power adaptor into terminal block numbers 1 and 2. Number 1 is positive voltage and 2 negative
(GND).
Please note power adaptor current should be at least 1500 mA.
Then insert two pieces of CR123A batteries included in the package. (If power adaptor is not used, insert batte-
ries only).
2.4. Register Admin Number
The LED will blink a few times until it is connected to an available network. Please wait for LED becomes solid ON.
Once LED is ON; that means device is connected to a GSM network and ready to work.

THE LIST OF COMMANDS (table 1)
DESCRIPTION COMMAND DEFAULT
Change password NEWP:XXXX 1111
Add / change user 1 TEL1:+XXXXXXXXXX
Add / change user 2 TEL2:+XXXXXXXXXX
Delete user 1 DEL1
Delete user 2 DEL2
Enable Keep Alive ENABLE Enable (weekly)
Disable Keep Alive DISABLE Enable (weekly)
Reset device RESET
Now please call the device’s number with your phone. Once you hear the ringing volume, your number is registe-
red to devices memory as ADMIN NUMBER.
Then the LED will blink and device will send you an SMS including “ADMIN OK” message. After you receive this
message; please wait for LED becomes solid ON again. If done; you ready for next step.
2.5. Send Configuration Commands
Please note all commands should start with an admin password (except RESET command). Default password is
“1111”. Also, it is possible to send one or several commands in one SMS.
Commands should be written in “big letters” (correct one: 1111 NEWP:3333, wrong one is: 1111 newp:3333).
There should be a space character between independent commands e.g.: 1111<space>NEWP:1234<space>DEL1<spa
ce>DISABLE
Device is case sensitive; please pay attention to text message ingredients.
Attention: If you write the password wrong you will receive an SMS including “WRONG PSWR” text. In that case
correct password. Otherwise device will keep the same settings and continue operation after 2 minutes timeout and
LED will become OFF.

EXAMPLES:
1) QUICK CONFIGURATION:
1111
the device; it will reply you with an SMS including “CONFIG OK <XX>” text (where XX is GSM signal strength, see
“Table-2” for further details). Now LED will turn off and your device is ready to operate.
2) EXTENDED CONFIGURATION:
1111 NEWP:5555 TEL1:+906661234567 TEL2:+907771234567 DISABLE
Above example means:
future. Please note it carefully.
• You added a new user1 number +906661234567.
• You added a new user2 number +907771234567.
• Weekly keep alive messages are disabled.
Once you sent this SMS to your device, it will reply you with an SMS including “CONFIG OK <XX>” text (where
XX is GSM signal strength, see “Table-2” for further details). Now LED will turn off and your device is ready to
operate.
Finally close the cover and insert screws on the back.
<XX> BETYDELSE RÅD
Between 19-31 Excellent signal
Between 14-18 Good signal
Between 9-13 Workable signal Try changing location
Between 1-8 Weak signal Check antenna / change device
location
99
SIGNALSTYRKA - GSM (tabell 2)

Now your device will continuously check for:
• NO and NC port changesTemperature Restorations
• Power failure and restorations
• Low battery
• And keep alive message periods
In case of NO port is closed (short-circuit) you and other users (if registered) will receive SMS including “PORT1
ALARM” texts.
In case of NC port is open (open-circuit) you and other users (if registered) will receive SMS including “PORT2
ALARM” texts.
In case of power failure, power restoration, keep alive period exceeds and low battery case; you and other users
will only receive SMS including “POWER FAIL”, “POWER OK”, “STILL ALIVE” and “LOW BATTERY” texts.
3.1. Re-configure Your Device
-
mands”.
3.2. Check GSM Signal Strength
Please follow article 3.1 and then only send your last password with SMS. You will receive “CONFIG OK <XX>” text
message where <XX> indicates GSM Signal Strength. For further description please see “Table-2”.
3.3. Reset Your Device
solid ON. Then send an SMS to the device including “RESET” command. LED will blink a few times and become so-
lid ON. Now your device has been reset, it is ready to start. Please follow instructions starting from “2.4. Register
Admin Number”.
3. Normal operation and alarms

Intab SMS-alarm
Power supply • 2 x CR123A batteries
• 12 V 1500 mA DC adaptor
Inputs • SMS in case of NO Port Failure
• SMS in case of NC Port FailurePower adaptor input
• Power adaptor input
Outputs • Not available
GSM module • GSM 900/1800 MHz Dual Band (A1400)
• GSM 850/900/1800/1900 MHz Quad Band (A1400-
Quad)
Event alerts
• SMS in case of NO Port Failure
• SMS in case of NC Port Failure
• SMS for Power Failure
• SMS for Power Restored
• SMS for Low Battery
• SMS for Keep Alive Messages
•
• Change security password
• Register & delete user phone numbers (up to 2)
• Enable & disable weekly keep alive messages
• Reset device
Operating temperature • -10°C to +50°C (non-condensing)
Dimensions • 109x54x30 mm
Package content • 1 x A1400 GSM Temperature Detector
• 2 x CR123A Lithium Batteries
• 1 x User Manual
• 4 x Fixing Screws & Insertion Pies
Technical specification

www.intab.se • [email protected] • +46 302-24 600
Gjutarevägen 1 • 443 61 Stenkullen
My data:
Admin telephone number:
Password:
Telephone number SIM:
Table of contents
Other Intab Security System manuals