Disclaimer
Information in this document is provided in connection with Intel®products. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel®’s
Terms and Conditions of Sale for such products, Intel®assumes no liability whatsoever, and Intel®disclaims any
express or implied warranty, relating to sale and/or use of Intel®products including liability or warranties relating to
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property
right. Intel®products are not designed, intended or authorized for use in any medical, life saving, or life sustaining
applications or for any other application in which the failure of the Intel product could create a situation where
personal injury or death may occur. Intel®may make changes to specifications and product descriptions at any time,
without notice.
Intel®server boards contain a number of high-density VLSI and power delivery components that need adequate
airflow for cooling. Intel®’s own chassis are designed and tested to meet the intended thermal requirements of these
components when the fully integrated system is used together. It is the responsibility of the system integrator that
chooses not to use Intel®developed server building blocks to consult vendor datasheets and operating parameters
to determine the amount of airflow required for their specific application and environmental conditions. Intel
Corporation can not be held responsible if components fail or the server board does not operate correctly when used
outside any of their published operating or non-operating limits.
Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in
the United States and other countries.
* Other names and brands may be claimed as the property of others.
Copyright © 2012, Intel Corporation. All Rights Reserved

Intel® Server Board S1200BT Service Guide iii
Safety Information
Important Safety Instructions
Read all caution and safety statements in this document before performing any of the
instructions. See also Intel Server Boards and Server Chassis Safety Information on the
Intel®Server Deployment Toolkit CD and/or at http://www.intel.com/support/
motherboards/server/sb/cs-010770.htm.
Wichtige Sicherheitshinweise
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor
Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu
Intel-Serverplatinen und Servergehäusen auf der Intel®Server Deployment Toolkit CD
oder unter http://www.intel.com/support/motherboards/server/sb/cs-010770.htm.
Consignes de sécurité
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce
document avant de suivre toute instruction. Consultez Intel Server Boards and Server
Chassis Safety Information sur le Intel®Server Deployment Toolkit CD ou bien rendez-
vous sur le site http://www.intel.com/support/motherboards/server/sb/cs-010770.htm.
Instrucciones de seguridad importantes
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety
Information en el Intel®Server Deployment Toolkit CD y/o en http://www.intel.com/
support/motherboards/server/sb/cs-010770.htm.

iv Intel® Server Board S1200BT Service Guide
䞡㽕ᅝܼᣛᇐ

Intel® Server Board S1200BT Service Guide v
Warnings
Heed safety instructions: Before working with your server product, whether you are
using this guide or any other resource as a reference, pay close attention to the safety
instructions. You must adhere to the assembly instructions in this guide to ensure and
maintain compliance with existing product certifications and approvals. Use only the
described, regulated components specified in this guide. Use of other products/
components will void the UL listing and other regulatory approvals of the product and
will most likely result in noncompliance with product regulations in the region(s) in which
the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To
remove power from system, you must unplug the AC power cord from the wall outlet.
Make sure the AC power cord is unplugged before you open the chassis, add, or remove
any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be
present on power, telephone, and communication cables. Turn off the server and
disconnect the power cord, telecommunications systems, networks, and modems attached
to the server before opening it. Otherwise, personal injury or equipment damage
can happen.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives,
boards, and other parts. We recommend that you perform all procedures in this chapter
only at an ESD workstation. If one is not available, provide some ESD protection by
wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on
your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely
sensitive to ESD. Hold boards only by their edges. After removing a board from its
protective wrapper or from the server, place the board component side up on a grounded,
static free surface. Use a conductive foam pad if available but not the board wrapper. Do
not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips
over two jumper pins. Some jumpers have a small tab on top that you can grip with your
fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab,
take care when using needle nosed pliers to remove or install a jumper; grip the narrow
sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can
damage the contacts inside the jumper, causing intermittent problems with the function
controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool
you use to remove a jumper, or you may bend or break the pins on the board.

vi Intel® Server Board S1200BT Service Guide

Intel®Server Board S1200BT Service Guide vii
Preface
About this Manual
Thank you for purchasing and using the Intel® Server Board S1200BT.
This manual is written for system technicians who are responsible for troubleshooting,
upgrading, and repairing this server board. This document provides a brief overview of
the features of the board/chassis, a list of accessories or other components you may need,
troubleshooting information, and instructions on how to add and replace components on
the Title of document. For the latest version of this manual, see: http://www.intel.com/
support/motherboards/server.
Manual Organization
Chapter 1 provides a brief overview of the Server Board S1200BTL and S1200BTS. In
this chapter, you will find a list of the server board features, photos of the product, and
product diagrams to help you identify components and their locations.
Chapter 2 provides instructions on using the utilities shipped with the board or that may be
required to update the system. This includes how to navigate through the BIOS Setup
screens, perform a BIOS update, and reset the password or CMOS. Information about the
specific BIOS settings and screens is available in the Technical Product Specification. See
"Additional Information and Software" for a link to the Technical Product Specification.
Chapter 3 provides instructions on adding and replacing components. Use this chapter for
step-by-step instructions and diagrams for installing or replacing components such as the
memory, processor, control panel board, and battery, among other components.
Chapter 4 provides troubleshooting information. In this chapter, you will find BIOS error
messages and POST code messages. You will also find suggestions for performing
troubleshooting activities to identify the source of a problem.
Product Accessories
This server board is compatible with Intel®Server Chassis P4304XXSFCN and
P4304XXSHCN.
You may need or want to purchase one or more of the following accessory items for
your server.

viii Intel® Server Board S1200BT Service Guide
Processor, memory DIMMs, hard drive, floppy drive, CD-ROM or DVD-ROM drive,
RAID controller, operating system.
For information about which accessories, memory, processors, and third-party hardware
were tested and can be used with your board, and for ordering information for Intel
products, see: http://www.intel.com/support/motherboards/server.
Additional Information and Software
If you need more information about this product or information about the accessories that
can be used with this server board, use the following resources. These files are available
at: http://www.intel.com/support/motherboards/server.
Unless otherwise indicated in the following table, once on this Web page, type the
document or software name in the search field at the left side of the screen and select the
option to search S1200BT.
Table 1. Additional Information and Software
For this information or
software Use this Document or Software
For in-depth technical
information about this
product, including BIOS
settings and chipset
information
Intel® Server Board S1200BT Technical Product Specification
If you just received this
product and need to
install it
Intel® Server Board S1200BT Quick Start User's Guide in the
product box
Accessories or other Intel
server products
Spares/Parts List & Configuration Guide
Hardware (peripheral
boards, adapter cards,
and so forth) and
operating systems that
were tested with this
product
For the Tested Hardware Operating Systems List, you can go to the
Intel®Server Configurator Tool:
http://serverconfigurator.intel.com/default.aspx
Chassis that were tested
with this product
Reference Chassis List
Processors that were
tested with this product
Supported Processors
DIMMs that were tested
with this product
Tested Memory List
To make sure your
system falls within the
allowed power budget
Power Budget Tool

Intel®Server Board S1200BT Service Guide ix
See also the Intel®Server Deployment Toolkit CD that came with your server board.
For software to manage
your Intel®server
Intel Server Management Software
For drivers •Driver (for an extensive list of available drivers)
•Operating System Driver (for operating system drivers)
For firmware and BIOS
updates, or for BIOS
recovery
Please go to mainpage on for “S1200BT”. It is under the Software
and Drivers section for the most current BIOS, FRU/SDR, BMC,
drivers and utilites
For diagnostics test
software
Diagnostics
Table 1. Additional Information and Software
For this information or
software Use this Document or Software

xIntel® Server Board S1200BT Service Guide

Intel®Server Board S1200BT Service Guide xi
Table of Contents
Safety Information ..................................................................................................... iii
Important Safety Instructions ................................................................................................ iii
Wichtige Sicherheitshinweise ............................................................................................... iii
Consignes de sécurité .......................................................................................................... iii
Instrucciones de seguridad importantes ............................................................................... iii
Warnings ................................................................................................................................ v
Preface ....................................................................................................................... vii
About this Manual ................................................................................................................ vii
Manual Organization ............................................................................................................vii
Product Accessories ............................................................................................................vii
Additional Information and Software ....................................................................................viii
Chapter 1: Server Board Features ............................................................................ 1
Connector and Header Locations ..........................................................................................6
Configuration Jumpers .........................................................................................................10
Back Panel Connectors .......................................................................................................12
RAID Support .......................................................................................................................13
Hardware Requirements ......................................................................................................13
Processor ....................................................................................................................13
Memory ........................................................................................................................14
Power Supply ..............................................................................................................15
Optional Hardware ...............................................................................................................15
Intel®SAS RAID Module .............................................................................................15
Chapter 2: Server Utilities ........................................................................................ 19
Using the BIOS Setup Utility ................................................................................................19
Starting Setup ..............................................................................................................19
Setup Navigation Keyboard Commands .....................................................................19
BIOS Setup Utility Screens ..........................................................................................21
Upgrading the BIOS .............................................................................................................62
Preparing for the Upgrade ...........................................................................................62
Upgrading the BIOS ....................................................................................................63
Recovering the BIOS ...................................................................................................63
Recovering the BIOS ...........................................................................................................65
Clearing the Password .........................................................................................................66
Chapter 3: Hardware Installations and Upgrades ................................................. 69
Before You Begin .................................................................................................................69
Tools and Supplies Needed ........................................................................................69
Installing and Removing Memory ........................................................................................69

xii Intel®Server Board S1200BT Service Guide
Installing DIMMs .......................................................................................................... 69
Removing DIMMs ........................................................................................................ 70
Installing the Processor ............................................................................................... 71
Installing the Heatsink(s) ............................................................................................. 74
Removing a Processor ................................................................................................ 75
Installing a PCI Card ................................................................................................... 76
Replacing the Backup Battery ............................................................................................. 78
Appendix A: LED Decoder .......................................................................................81
Appendix B: Intel®Server Issue Report Form .......................................................87
Appendix C: Getting Help ........................................................................................93
Warranty Information ...........................................................................................................93
Appendix D: Troubleshooting .................................................................................95
System Boot Quiet Time ..................................................................................................... 95
Resetting the System .......................................................................................................... 95
Problems following Initial System Installation ...................................................................... 96
First Steps Checklist ................................................................................................... 96
Hardware Diagnostic Testing .............................................................................................. 97
Verifying Proper Operation of Key System Lights ....................................................... 97
Confirming Loading of the Operating System ............................................................. 97
Specific Problems and Corrective Actions .......................................................................... 98
Power Light Does Not Light ........................................................................................ 98
No Characters Display on Screen ............................................................................... 99
Characters Are Distorted or Incorrect ......................................................................... 99
System Cooling Fans Do Not Rotate Properly .......................................................... 100
Drive Activity Light Does Not Light ............................................................................ 100
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light ............................ 100
Cannot Connect to a Server ...................................................................................... 101
Problems with Network ............................................................................................. 101
System Boots when Installing PCI Card ................................................................... 102
Problems with Newly Installed Application Software ................................................. 102
Problems with Application Software that Ran Correctly Earlier ................................ 103
Devices are not Recognized under Device Manager (Microsoft Windows* Operating Sys-
tem) ............................................................................................................... 103
Hard Drive(s) are not Recognized ............................................................................. 103
Bootable CD-ROM Disk Is Not Detected .................................................................. 104
LED Information ........................................................................................................ 104
BIOS POST Beep Codes .......................................................................................... 104

Intel®Server Board S1200BT Service Guide xiii
List of Figures
Figure 1. Intel®Server Board S1200BTL .................................................................................. 1
Figure 2. Intel®Server Board S1200BTS Picture ..................................................................... 2
Figure 3. Connector and Component Location ......................................................................... 7
Figure 4. Intel®Server Board S1200BTS Layout...................................................................... 9
Figure 5. Jumper Blocks (J2G1, J1G1, J1H3, and J2J1) on S1200BTS................................. 10
Figure 6. Configuration Jumpers Location .............................................................................. 12
Figure 7. Back Panel Connectors............................................................................................ 12
Figure 8. Intel®SAS Entry RAID Module ................................................................................ 16
Figure 9. Main Screen............................................................................................................. 24
Figure 10. Advanced Screen................................................................................................... 27
Figure 11. Processor Configuration Screen ............................................................................ 29
Figure 12. Memory Configuration Screen ............................................................................... 36
Figure 13. Mass Storage Controller Configuration Screen...................................................... 39
Figure 14. Serial Port Configuration Screen............................................................................ 42
Figure 15. USB Configuration Screen..................................................................................... 42
Figure 16. PCI Configuration Screen ...................................................................................... 43
Figure 17. System Acoustic and Performance Configuration.................................................. 44
Figure 18. Security Screen...................................................................................................... 46
Figure 19. Server Management Screen (S1200BTL).............................................................. 49
Figure 20. Server Management Screen (S1200BTS) ............................................................. 50
Figure 21. Console Redirection Screen .................................................................................. 50
Figure 22. System Information Screen (S1200BTL) ............................................................... 51
Figure 23. System Information Screen (S1200BTS) ............................................................... 52
Figure 24. BMC LAN Configuration Screen (S1200BTL) ........................................................ 53
Figure 25. Hardware Monitor Screen, Auto Fan Control (S1200BTS) .................................... 54
Figure 26. Hardware Monitor Screen, Manual Fan Control (S1200BTS)................................ 54
Figure 27. Realtime Teperature and Voltage Status Screen (S1200BTS).............................. 55
Figure 28. Boot Options Screen.............................................................................................. 56
Figure 29. Hard Disk Order Screen......................................................................................... 57
Figure 30. CDROM Order Screen........................................................................................... 57
Figure 31. Floppy Order Screen.............................................................................................. 58
Figure 32. Network Device Order Screen ............................................................................... 58
Figure 33. BEV Device Order Screen ..................................................................................... 59
Figure 34. Add EFI Boot Option Screen.................................................................................. 59
Figure 35. Delete EFI Boot Option Screen.............................................................................. 60
Figure 36. Boot Manager Screen ............................................................................................ 60
Figure 37. Error Manager Screen............................................................................................ 61
Figure 38. System Event Log Screen (S1200BTS)................................................................. 61
Figure 39. Exit Screen............................................................................................................. 62
Figure 40. BIOS Recovery Jumper ......................................................................................... 65
Figure 41. Password Recovery Jumper .................................................................................. 66
Figure 42. CMOS Recovery Jumper ....................................................................................... 67

xiv Intel®Server Board S1200BT Service Guide
Figure 43. BMC Force Update Jumper ................................................................................... 67
Figure 44. Installing Memory................................................................................................... 70
Figure 45. Lifting the Load Lever ............................................................................................ 72
Figure 46. Open the Load Plate.............................................................................................. 72
Figure 47. Remove the Socket Protective Cover.................................................................... 73
Figure 48. Remove the Processor Protective Cover............................................................... 73
Figure 49. Installing the Processor ......................................................................................... 73
Figure 50. Close the Load Plate and Socket Lever ................................................................ 74
Figure 51. 2U Reference Heatsink Assembly ......................................................................... 75
Figure 52. Removing the PCI Riser Assembly from the Server System................................. 76
Figure 53. Installing a PCI Card in a Riser Card..................................................................... 77
Figure 54. Replacing the Backup Battery ............................................................................... 79
Figure 55. Diagnostic LED Placement Diagram ..................................................................... 81

Intel® Server Board S1200BT Service Guide xv
List of Tables
Table 1. Additional Information and Software .........................................................................viii
Table 2. Server Board Features ................................................................................................3
Table 3. NIC LED Descriptions ...............................................................................................13
Table 4. Memory Configuration Table. ....................................................................................14
Table 5. BIOS Setup: Keyboard Command Bar ......................................................................19
Table 6. POST Progress Code LED Example .........................................................................82
Table 7. Diagnostic LED POST Code Decoder .......................................................................82
Table 8. Resetting the System ................................................................................................95
Table 9. LED Information ......................................................................................................104
Table 10. POST Error Beep Codes .......................................................................................105

xvi Intel® Server Board S1200BT Service Guide

Intel® Server Board S1200BT Service Guide 1
1Server Board Features
This chapter briefly describes the main features of the Intel® Server Board S1200BTL and
S1200BTS. This chapter provides a photograph of the product, list of the server board
features, and diagrams showing the location of important components and connections on
the server board.
Figure 1. Intel®Server Board S1200BTL

2Intel® Server Board S1200BT Service Guide
Figure 2. Intel®Server Board S1200BTS Picture

Intel® Server Board S1200BT Service Guide 3
Table 2 summarizes the features of the server board.
Table 2. Server Board Features
Feature Description of S1200BTL Description of S1200BTS
Processors Supports for one Intel®Xeon®E3-
1200Processors or the 2nd Generation Intel®
Core™ i3 Processors in FC-LGA 1155 socket
package.
•5 GT/s point-to-point DMI interface to
PCH
•LGA 1155 pin socket
Supports for Intel®Xeon®E3-1200 V2
processors or the 3rd Generation Intel®
Core™ i3 processors in FC-LGA 1155 socket
package.
•5 GT/s point-to-point DMI interface to
PCH
•LGA 1155 pin socket
Supports for one Intel®Xeon®E3-1200
Processors or the 2nd Generation Intel®
Core™ i3 Processors in FC-LGA 1155
socket package.
•5 GT/s point-to-point DMI interface to
PCH
•LGA 1155 pin socket
Supports for Intel®Xeon®E3-1200 V2
processors or the 3rd Generation Intel®
Core™ i3 processors in FC-LGA 1155
socket package.
•5 GT/s point-to-point DMI interface to
PCH
•LGA 1155 pin socket
Memory Two memory channels with support for 1066/
1333 MHz (with Intel®Xeon®E3-1200
Processors or the 2nd Generation Intel®
Core™ i3 Processors) or 1333/1600 MHz
(with Intel®Xeon®E3-1200 V2 Processors or
the 3rd Generation Intel®Core™ i3
Processors) ECC Unbuffered (UDIMM) DDR3.
•Up to 2 UDIMMs per channel
•32 GB max with x8 ECC UDIMM (2-Gb
DRAM)
•64-bit wide channels
•DDR3 I/O Voltage of 1.5 V
Two memory channels with support for
1066/1333 MHz (with Intel®Xeon®E3-
1200 Processors or the 2nd Generation
Intel®Core™ i3 Processors) or 1333/
1600 MHz (with Intel®Xeon®E3-1200 V2
Processors or the 3rd Generation Intel®
Core™ i3 Processors) ECC Unbuffered
(UDIMM) DDR3.
•Up to 2 UDIMMs per channel
•32 GB max with x8 ECC UDIMM (2-
Gb DRAM)
•64-bit wide channels
•DDR3 I/O Voltage of 1.5 V
Chipset •Support for Intel®C204 Platform
Controller Hub (PCH) chipset
•ServerEngines* LLC Pilot III BMC
controller (Integrated BMC)
Support for Intel®C202 Platform
Controller Hub (PCH) chipset

4Intel® Server Board S1200BT Service Guide
I/O External connections:
•DB-15 video connectors
•DB-9 serial Port A connector
•Four ports on two USB/LAN combo
connectors at rear of board
Internal connections:
•Two USB 2x5 pin headers, each
supporting two USB 2.0 ports
•One 2x5 Serial Port B headers
•One I/O Module Connector
•Two 6Gb/s SATA ports and four 3Gb/s
SATA ports
•One SAS mezzanine slot supports for
optional SAS module
•Smart Module connector
External connections:
•DB-15 video connectors
•DB-9 serial Port A connector
•Four ports on two USB/LAN combo
connectors at rear of board
Internal connections:
•Two USB 2x5 pin headers, each
supporting two USB 2.0 ports
•One 2x5 Serial Port B headers
•Six 3Gb/s SATA ports
Add-in PCI, PCI
Express* Cards
With Intel®Xeon®E3-1200 processors or the
2nd Generation Intel®Core™ i3 Processors:
•Slot1: One 5V PCI 32 bit/33 MHz
connector
•Slot3: One PCI Express* Gen2 x8 (x4
throughput) connector
•Slot4: One PCI Express* Gen2 x8 (x4
throughput) connector
•Slot5: One PCI Express* Gen2 x8 (x4
throughput) connector
•Slot6: One PCI Express* Gen2 x16 (x8
throughput) connector
With Intel®Xeon®E3-1200 V2 processors or
the 3rd Generation Intel®Core™ i3
Processors:
•Slot1: One 5V PCI 32 bit/33 MHz
connector
•Slot3: One PCI Express* Gen2 x8 (x4
throughput) Gen2 connector
•Slot4: One PCI Express* Gen3 x8 (x4
throughput) connector
•Slot5: One PCI Express* Gen3 x8 (x4
throughput) connector
With Intel®Xeon®E3-1200 processors or
the 2nd Generation Intel®Core™ i3
Processors:
•Slot4: One 5V PCI 32 bit/33 MHz
connector
•Slot5: One PCI Express* Gen2 x8 (x4
throughput) connector
•Slot6: One PCI Express* Gen2 x8 (x8
throughput) connector
•Slot7: One PCI Express* Gen2 x16
(x8 throughput) connector
With Intel®Xeon®E3-1200 V2 processors
or the 3rd Generation Intel®Core™ i3
Processors:
•Slot4: One 5V PCI 32 bit/33 MHz
connector
•Slot5: One PCI Express* Gen2 x8 (x4
throughput) connector
•Slot6: One PCI Express* Gen3 x8 (x8
throughput) connector
•Slot7: One PCI Express* Gen3 x16
(x8 throughput) connector
System Fan
Support
Five 4-pin fan headers supporting four system
fans and one processor
Four 4-pin fan headers supporting four
system fans and one processor
Video Onboard ServerEngines* LLC Pilot III BMC
Controller
Silicon Motion SM712GX04LF02-BA
Feature Description of S1200BTL Description of S1200BTS
Table of contents
Other Intel Motherboard manuals

Intel
Intel P43 User manual

Intel
Intel DZ68DB User manual

Intel
Intel DP67BG Quick start guide

Intel
Intel DH57DD User manual

Intel
Intel D865PERLX User manual

Intel
Intel BLKD410PT User manual

Intel
Intel DZ77GA-70K Quick start guide

Intel
Intel D915GEV User manual

Intel
Intel D915PLWD User manual

Intel
Intel D425KT User manual

Intel
Intel D955XBK User manual

Intel
Intel DH87RL Quick setup guide

Intel
Intel BLKDG41CN Configuration guide

Intel
Intel P31 User manual

Intel
Intel BOXD865GVHZ Configuration guide

Intel
Intel SE7501HG2 User manual

Intel
Intel DH61CR User manual

Intel
Intel Movidius MV0212 User manual

Intel
Intel DG41AN User manual

Intel
Intel KEMX-2030 User manual